Labshake search
Citations for GE Life Sciences :
101 - 150 of 2555 citations for Mouse T Cell Surface Glycoprotein CD8 Beta Chain CD8B ELISA Kit since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Microbiology 2020Quote: Surface Plasmon Resonanace (SPR) analysis was performed at 25°C using BIAcore T200 instrument (GE Healthcare). Wild type CcpA and V301A mutant proteins were immobilized on sensor chip CM5 via amine coupling ...
-
bioRxiv - Immunology 2020Quote: ... Sensor chip surfaces were regenerated after each injection following manufacture instructions with Glycine 2.5 (GE Healthcare Life Sciences 10 mM glycine - HCl at pH 2.5 ...
-
bioRxiv - Microbiology 2023Quote: ... Surface-disinfected seeds were sown on two layers of filter paper (Whatman, GE Healthcare Life Sciences) in Petri dishes (90 mm in diameter ...
-
bioRxiv - Microbiology 2024Quote: ... and the surface proteins were bound to streptavidin Sepharose beads overnight at 4°C (GE Healthcare). Beads were then washed with buffer containing 100 mM Tris ...
-
bioRxiv - Cell Biology 2024Quote: Images of the hybrid bilayer on the gold surface were taken with a DeltaVision (Applied Precision) wide-field microscope using a 10x Olympus lens and air-cooled CCD camera ...
-
bioRxiv - Immunology 2021Quote: ... iPSC-moDC and MDM were washed with T cell expansion medium (RPMI supplemented with 10% HyClone FBS (GE Healthcare, Chicago, IL, USA), 1000 U/mL Penicillin/streptomycin ...
-
bioRxiv - Biochemistry 2023Quote: ... pH 4.5) and K29-linked and K48-linked chains were separated by ion exchange (MonoS cation column, GE Healthcare) with buffer A containing 50 mM NaOAc ...
-
bioRxiv - Neuroscience 2020Quote: Continuous 12-lead surface ECG and intracardiac ECG data were recorded using a Prucka CardioLab (GE Healthcare). For ARI recordings ...
-
bioRxiv - Biophysics 2020Quote: ... Neutravidin (Pierce) was amine coupled to the carboxymethylated dextran surface of a CM5 sensor chip (GE Healthcare) using standard amine coupling chemistry ...
-
bioRxiv - Molecular Biology 2020Quote: All the surface preparation experiments were performed at 25°C using a Biacore 3000 instrument (GE Healthcare). Purified Rubisco was immobilized on CM5 sensor chips using a Biacore Amine Coupling Kit according to the manufacturer’s instructions ...
-
bioRxiv - Neuroscience 2020Quote: ... Binding of GAPDH proteins to EV surface was monitored by UV-280 chromatogram (Akta pure, GE Healthcare), western blotting ...
-
bioRxiv - Molecular Biology 2021Quote: Interaction experiments using surface plasmon resonance (SPR) were carried out with a Biacore T200 system (GE Healthcare) according to the manufacturer’s protocols and recommendations ...
-
bioRxiv - Biochemistry 2020Quote: ... cleared lysates from ARL15A86L expressing Flp-In™ T-REx™ HeLa cells were incubated with streptavidin beads (17-5113-01, 5 ml, GE Healthcare). Trypsin digestion on beads was performed and peptides were collected in water ...
-
bioRxiv - Immunology 2020Quote: ... Fractions that yielded proliferation of TN T cells were pooled and subjected to cation exchange chromatography on a Mono S 5/200 GL column (GE Healthcare, Piscataway NJ). The active fractions were again pooled and subjected to buffer exchange (Amicon ultra 3k cutoff ...
-
bioRxiv - Biochemistry 2020Quote: ... The reaction was stopped by 20-fold dilution in 50 mM sodium acetate (pH 4.5) and chains of different lengths were separated by cation exchange using a Resource S column (GE Healthcare). Elution of different chain lengths was achieved with a gradient from 0 to 600 mM NaCl.
-
bioRxiv - Biochemistry 2023Quote: ... The respective reactions were stopped by 20-fold dilution in 50 mM sodium acetate (pH 4.5) and chains of different lengths were separated by cation exchange using a Resource S column (GE Healthcare). Elution of different chain lengths was achieved with a gradient from 0 to 600 mM NaCl.
-
bioRxiv - Molecular Biology 2020Quote: Surface plasmon resonance (SPR) analysis was performed using a Biacore T200 with the CM5 sensor chip (GE Healthcare) at room temperature (25 °C) ...
-
bioRxiv - Neuroscience 2020Quote: Binding kinetics of VNAR-Fcs was determined by surface plasmon resonance (SPR) using a Biacore T200 (GE Healthcare). A His-capture kit (GE Healthcare ...
-
bioRxiv - Immunology 2022Quote: ... and EPICERTIN were also determined by surface plasmon resonance (SPR) using the Biacore Gold Seal T200 (GE Healthcare) equipped with a CM5 sensor chip as previously described 19 ...
-
bioRxiv - Immunology 2021Quote: The affinity of nanobodies was measured by surface plasmon resonance (Biacore 3000, GE Healthcare Bio-Sciences AB, Sweden). Recombinant RBD protein at a concentration 20 μg/ml in 10 mM acetate buffer (pH 4.5 ...
-
bioRxiv - Immunology 2021Quote: All surface plasmon resonance experiments were performed at 25°C using a Biacore T200 instrument (Cytiva, GE Healthcare) equipped with a flat carboxymethyldextran sensor chip (CMDP ...
-
bioRxiv - Immunology 2021Quote: Surface plasmon resonance assays were performed by a BIAcore T100 instrument with a CM5 sensor chip (GE Healthcare). Experiments were carried out at 25°C in binding buffer (PBS ...
-
bioRxiv - Biochemistry 2022Quote: ... The biotinylated Norrin samples were immobilized onto the surface of a CM5 sensor chip (GE Healthcare Life Sciences) on which approximately 8500 resonance units of streptavidin were coupled via primary amines ...
-
bioRxiv - Immunology 2022Quote: The surface plasmon resonance (SPR) experiments were performed on Biacore Model T200 equipment (GE Healthcare Biosciences, Uppsala, Sweden). For the immobilization of human SIRT1 (catalog number S8846 ...
-
bioRxiv - Microbiology 2023Quote: The surface plasmon resonance (SPR) experiments were performed at 25 °C on a BIAcore 2000 instrument (GE Healthcare). DsrC-trisulfide was immobilized on a NTA sensor chip (GE Healthcare ...
-
bioRxiv - Molecular Biology 2023Quote: Surface plasmon resonance (SPR) affinity and kinetic analysis was carried out using the Biacore T200 instrument (GE Healthcare). aMino sdAbs were immobilized to a CM5 sensor chip at a density of 4300-4600 RU ...
-
bioRxiv - Immunology 2023Quote: The SPR (surface plasmon resonance) analysis was performed using a Biacore T200 machine with CM5 chips (GE Healthcare) at room temperature (25°C) ...
-
bioRxiv - Bioengineering 2024Quote: Surface plasmon resonance measurements were performed using a NTA chip on a Biacore X100 SPR system (GE Healthcare) according to manufacturer’s recommendations ...
-
bioRxiv - Cancer Biology 2020Quote: ... the membranes were incubated with 10,000-fold diluted peroxidase-linked secondary antibody (NA931V for FLAG-BRCA2 and NA934V for beta-Actin; GE Healthcare) at room temperature for 4 hours ...
-
bioRxiv - Biochemistry 2022Quote: ... and eluted by gradient introduction of high-salt buffer (50mM Tris pH7.0, 1M NaCl, 2mM MgCl2, 1mM ATP, 2mM beta-mercaptoethanol) on an ÅKTA system (GE Healthcare). Protein-containing pooled fractions from IEX were then loaded onto a Superdex 200 Increase 10/300 GL gel filtration column (GE Healthcare ...
-
bioRxiv - Immunology 2022Quote: ... His-tagged Fabs were prepared by transient transfection of truncated heavy chain genes encoding a C-terminal 6x-His tag with a light chain expression vector and purified from supernatants using a 5 mL HisTrap colum (GE Healthcare) followed by SEC as described above.
-
bioRxiv - Molecular Biology 2020Quote: Affimer affinities for KRAS were determined by surface plasmon resonance (SPR) using a BIAcore 3000 (GE Healthcare Europe GmbH). Affimer proteins with a C-terminal cysteine residue were biotinylated with the biotin-maleimide (SigmaAldrich ...
-
bioRxiv - Biochemistry 2019Quote: Surface plasmon resonance (SPR) data were collected using a BIAcore T200 instrument using a L1 Sensor Chip (GE Healthcare). Both reference and ligand channels were equilibrated in 50 mM CAPS ...
-
bioRxiv - Biochemistry 2021Quote: ... and Hs-SUMO1 with Pf-Ubc9 and Hs-Ubc9 were determined using surface plasmon resonance (BIAcore T200 GE Healthcare) at 298K ...
-
bioRxiv - Biophysics 2020Quote: All surface plasmon resonance experiments were performed using a Biacore T200 apparatus (GE Healthcare Life Sciences/Biacore, Illinois, U.S) and data were recorded using the manufacturer software (Biacore control software v2.0) ...
-
bioRxiv - Biophysics 2020Quote: Surface plasmon resonance (SPR) assays were performed on Biacore S200 with a CM5 sensor chip (GE Healthcare Life Sciences) at room temperature ...
-
bioRxiv - Microbiology 2020Quote: ... Lea triose and Leb tetraose to RiLea/bBP was analyzed by surface plasmon resonance (SPR; Biacore T100, GE Healthcare). RiLea/bBP ...
-
bioRxiv - Immunology 2020Quote: ... HRP-conjugated anti-mouse and anti-rabbit secondary antibodies (Cell Signaling or GE Healthcare) were used at a 1:10,000 dilution ...
-
bioRxiv - Biophysics 2022Quote: ... ELISA was performed as described2 using an HRP-conjugated anti-M13 monoclonal antibody (GE Healthcare) and a TMB substrate kit (Thermo Fisher ...
-
Vasohibin1, a new IRES trans-acting factor for sequential induction of angiogenic factors in hypoxiabioRxiv - Cell Biology 2019Quote: BIA-MS studies based on surface plasmonic resonance (SPR) technology were performed on BIAcore T200 optical biosensor instrument (GE Healthcare), as described previously (13 ...
-
bioRxiv - Plant Biology 2021Quote: ... Bacterial colonisation was analysed by quantifying GFP fluorescence in abaxial leaf surface using a Typhoon FLA9500 laser scanner (GE Healthcare) and ImageJ analysis ...
-
bioRxiv - Microbiology 2020Quote: ... His-CD147 (produced by our laboratory) was fixed to the surface of CM5 sensor chips (GE Healthcare Bio-Sciences AB) by amino coupling kit (GE Healthcare ...
-
bioRxiv - Immunology 2021Quote: ... His-CyPA (produced by our laboratory) was fixed to the surface of CM5 sensor chips (GE Healthcare Bio-Sciences AB) by an Amine Coupling Kit (GE Healthcare ...
-
bioRxiv - Cell Biology 2022Quote: ... Flow cell 1 was left empty to use this flow cell as a reference flow-cell for on-line subtraction of bulk solution refractive index and for evaluation of non-specific binding of analyte to the chip surface using Biacore T100 Control Software (version 3.2) (GE Healthcare). FPLC-purified non-biotinylated protein was used as analyte ...
-
bioRxiv - Microbiology 2020Quote: The surface plasmon resonance experiments were performed at room temperature using a BiaCore T200 with CM5 sensor chips (GE Healthcare). The surfaces of the sample and reference flow cells were activated with a 1:1 mixture of 0.1 M NHS (N-hydroxysuccinimide ...
-
bioRxiv - Bioengineering 2022Quote: ... Flow cell 1 was left empty to use this flow cell as a reference flow-cell for on-line subtraction of bulk solution refractive index and for evaluation of non-specific binding of analyte to the chip surface using Biacore T100 Control Software (version 3.2) (GE Healthcare). FPLC-purified non-biotinylated protein was used as analyte ...
-
bioRxiv - Biochemistry 2023Quote: ... using a hollow fiber cartridge with a surface area of 4,800 cm2 and a nominal molecular weight cutoff (NMWC) of 10 kDa (GE Healthcare). All chromatography procedures were carried out at 4°C using either an ÄKTA express or ÄKTA pure chromatography system (GE Healthcare) ...
-
bioRxiv - Biochemistry 2023Quote: ... The purified EGFR recombinant extracellular domain was first coupled to the surface of a CM5 sensor chip (GE Healthcare Biosciences)) ...
-
bioRxiv - Microbiology 2019Quote: ... Kinetic analysis was performed using Biacore T-200 Evaluation Software v3.1 (GE Healthcare). Sensorgrams were analyzed using both Langmuir and Two-State Reaction binding models and a local value of Rmax.
-
bioRxiv - Neuroscience 2021Quote: Imaging data were acquired using a 3.0 T scanner (Discovery MR750, GE Healthcare) and an 8-channel head-coil ...