Labshake search
Citations for GE Life Sciences :
1401 - 1450 of 2414 citations for Aldosterone ELISA Kit 5 Plate since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Immunology 2024Quote: ... The lysate was clarified by centrifugation at 47,000 x g for 45min and applied to 5 ml His-Trap columns (GE Healthcare). After washing with a buffer excluding urea ...
-
bioRxiv - Biophysics 2024Quote: ... The supernatant was filtered in 0.45 µm filter and loaded into a 5 ml His-trap FF column (GE Healthcare) pre-equilibrated with buffer A (50 mM Tris-HCl pH 7.5 ...
-
bioRxiv - Microbiology 2022Quote: ... The purified protein was then dialyzed against 10 mM Tris HCl pH 8.0 and loaded on MonoQ 5/15 column (GE Healthcare) to be eluted using a step gradient of 240 mM and 400 mM NaCl in the same buffer.
-
bioRxiv - Molecular Biology 2023Quote: ... The lysate was centrifuged at 40,000 rcf for 1 h and the supernatant was filtered through a 0.45 μM syringe filter (Chromafil GF/PET 45, MachereyNagel) and passed through a HiTrap SP HP (5 mL, GE Healthcare) column connected to an NGC FPLC system (BioRad) ...
-
bioRxiv - Immunology 2023Quote: ... Supernatant was spun down at 400× g for 5 minutes followed by resuspension in a 33.75% (v/v) Percoll (GE Healthcare) diluted in PBS with 2% foetal calf serum and density gradient centrifugation at 700 x g for 12 minutes ...
-
bioRxiv - Immunology 2023Quote: ... Supernatant was spun down at 400× g for 5 minutes followed by resuspension in a an isotonic 33.75% (v/v) Percoll (GE Healthcare) diluted in PBS with 2% foetal calf serum and density gradient centrifugation at 700x g for 12 minutes ...
-
bioRxiv - Biophysics 2023Quote: ... followed by centrifugation at 20,000 x g where the clear lysate was subsequently loaded onto a 5 mL Ni-NTA Sepharose column (GE Healthcare) equilibrated with 50 mM Tris ...
-
bioRxiv - Biochemistry 2023Quote: ... The lysate was passed through a 0.22 µm filter and loaded onto a 5 ml HisTrap HP column (GE Healthcare). The column was washed with 25 ml of lysis buffer containing 30 mM imidazole ...
-
bioRxiv - Biochemistry 2023Quote: Elute from HisTrap consisting of the respective protein fractions were centrifuged at 39,000 g for 15 minutes and the supernatant was loaded on a 5 ml StrepTrap HP column (GE Healthcare). The binding buffer used was 150 mM NaCl ...
-
bioRxiv - Biochemistry 2022Quote: ... the supernatant was diluted 5-fold to contain 100 mM NaCl and purified over SP-Sepharose (HiPrep SPFF, GE Healthcare) using a linear gradient of buffer containing 2 M NaCl ...
-
bioRxiv - Cell Biology 2022Quote: ... the supernatant was loaded in an ÄKTA Pure purification system (Cytiva) onto a 5 ml HiTrap Chelating HP (GE Healthcare) charged with 0.1 mM NiCl2 and equilibrated with wash buffer (50 mM K-HEPES pH7.5 ...
-
bioRxiv - Biophysics 2023Quote: ... Double-labeled (488:594) protein was then further purified via ion-exchange chromatography (Mono S 5/50 GL, GE Healthcare).
-
bioRxiv - Cell Biology 2022Quote: ... Eluted fractions containing the desired protein were pooled and loaded onto a 5 ml cationic exchanger (S-column; GE Healthcare). A salt gradient of 0-1 M was applied over 20 min and the protein was eluted in 5 ml fractions ...
-
bioRxiv - Biophysics 2023Quote: ... HRP-secondary antibodies were incubated for 1-2 hours at room temperature in 5% milk and ECL were performed using the Amersham ECL Western Blotting Detection Reagents (Cat.no. RPN2106 from GE Healthcare). Detection was done using CL-Xposure films (Cat.no ...
-
bioRxiv - Biochemistry 2022Quote: ... Eluted fractions containing the desired protein were pooled and loaded onto a 5 ml cationic exchanger (S-column; GE Healthcare). A salt gradient of 0-1 M KCl was applied over 20 min (at 5 ml/min ...
-
bioRxiv - Biochemistry 2023Quote: ... and lysates were clarified (16,000 x g for 45 min at 4 °C) before being loaded onto a 5 mL HisTrap column (GE Healthcare). This was followed by one column volume (c.v. ...
-
bioRxiv - Biochemistry 2022Quote: ... The supernatant was filtered through a MF-Millipore Membrane Filter (0.45 µm pore size) then loaded on a 5 mL His-Trap HP column (GE Healthcare) pre-equilibrated with buffer A and CSE was eluted with a gradient from 20 mM to 250 mM imidazole in buffer A ...
-
bioRxiv - Cell Biology 2022Quote: ... the supernatant was loaded in an ÄKTA Pure purification system (Cytiva) onto a 5 ml HiTrap Chelating HP (GE Healthcare) charged with 0.1 mM NiCl2 ...
-
bioRxiv - Molecular Biology 2023Quote: ... centrifuged at 16,000 g for 20 min at 4°C and then injected into Superose 6 5/150 increase column (GE Healthcare) pre-equilibrated with analytical size-exclusion chromatography buffer (50 mM HEPES ...
-
bioRxiv - Biophysics 2023Quote: ... the Ni-NTA eluate was applied to size exclusion chromatography on a Superose 6 Increase 5/150 column (GE Healthcare) in basic buffer supplemented with 0.003 % LMNG and 0.0003 % CHS.
-
bioRxiv - Biochemistry 2023Quote: ... pH 8.0) and further purified via size exclusion chromatography (SEC) in an S75 5/150 GL increase column (GE Healthcare). Protein collected from SEC was normalized to 1 μM where possible.
-
bioRxiv - Molecular Biology 2023Quote: ... Then the samples were subjected to electrophoresis through 5% native polyacrylamide gel in 0.5x TBE buffer and imaged with 9410 Typhoon variable mode imager (GE Healthcare).
-
bioRxiv - Microbiology 2023Quote: ... the KhpA and KhpB-ΔN were secondly purified by cation-exchange chromatography (HiTrap SP 5 ml, GE Healthcare Life Science) followed by SDS-PAGE ...
-
bioRxiv - Biophysics 2024Quote: ... the protein was filtered and loaded onto two connected 5 ml HiTrap Q HP columns (GE Healthcare, 17- 1154-01) equilibrated with 10 mM Tris-HCl ...
-
bioRxiv - Biophysics 2024Quote: ... Double-labeled (488:594) protein was then further purified via ion-exchange chromatography (Mono Q 5/50 GL, GE Healthcare).
-
bioRxiv - Bioengineering 2024Quote: ... the soluble fraction of the cell lysate was passed through a 0.45-micron filter and then loaded onto a HisTrap HP 5 ml (GE Healthcare) column equilibrated with buffer A (20 mM Tris-HCl pH 8.0 ...
-
bioRxiv - Microbiology 2024Quote: ... The solubilized protein suspension was ultracentrifuged at 100,000 x g for 1 hour before being loaded onto a 5 ml HisTrap HP column (GE HealthCare). The column was washed with a purification buffer supplemented with 20 mM imidazole ...
-
bioRxiv - Biophysics 2024Quote: ... filtered through 0.45 μm cut-off filters and loaded onto a HiTrap CaptoS 5-ml column at 4° C (GE Healthcare). The column was washed with 10 vol ...
-
bioRxiv - Cell Biology 2020Quote: Polyclonal anti-GST antibodies (GST Capture Kit, GE Healthcare) were amine coupled on to a Series S CM5 sensor chip (GE Healthcare ...
-
bioRxiv - Molecular Biology 2021Quote: ... RNA was extracted using RNAspin Mini Kit (GE Healthcare).
-
bioRxiv - Neuroscience 2019Quote: ... Chemiluminescence was induced using an ECL kit (GE Healthcare) and densitometry was performed using Fiji/ImageJ (US National Institutes of Health).
-
bioRxiv - Evolutionary Biology 2020Quote: ... using illustra RNAspin Mini RNA Isolation Kit (GE Healthcare). First-strand cDNA was synthesized from 200 ng of total RNA in a 20-µL reaction volume using oligo-dT primers and iScript RT (Bio-Rad Laboratories).
-
bioRxiv - Bioengineering 2020Quote: ... GFX PCR purification kit was purchased from GE Healthcare.
-
bioRxiv - Biochemistry 2021Quote: ... developed with Amersham ECL prime kit (GE healthcare RPN2236), and imaged on an Alpha Innotech imaging system.
-
bioRxiv - Microbiology 2020Quote: ... by amino coupling kit (GE Healthcare, BR-1000-50); interaction between CD147 and SP (RBD ...
-
bioRxiv - Cell Biology 2021Quote: ... Bands were visualized using the ECL kit (GE Healthcare). Band densitometry was measured using ImageJ software.
-
bioRxiv - Plant Biology 2020Quote: ... LMW and HMW Gel Filtration calibration kits (GE Healthcare) were used to estimate the molecular weight of protein complexes ...
-
bioRxiv - Biochemistry 2020Quote: ... and ECL Prime Western Blotting Detection kit (GE Healthcare). Loading control was performed with anti-tubulin clone TAT-1 antibodies (a gift from K ...
-
bioRxiv - Developmental Biology 2019Quote: ... and Amersham ECL prime detection kit (GE healthcare, RPN2232). Blots were imaged on an Amersham Imager 600 ...
-
bioRxiv - Molecular Biology 2020Quote: ... For the GenomiPhi V3 DNA Amplification Kit (GE Healthcare), 1 µl of 10 ng/µl of plasmid DNA was mixed with 9 µl of molecular grade water and 10 µl of denaturation buffer ...
-
bioRxiv - Immunology 2021Quote: ... functionalised with an anti-His capture kit (GE Healthcare) using a Biacore T200 instrument ...
-
bioRxiv - Cell Biology 2022Quote: ... with Amersham HMW native marker kit (17044501; GE Healthcare) as a molecular weight marker ...
-
bioRxiv - Microbiology 2022Quote: The Genomiphi V2 DNA Amplification Kit (GE Healthcare, USA) was used for whole-genome multiple displacement amplification to generate sufficient DNA for metagenomic sequencing ...
-
bioRxiv - Biochemistry 2024Quote: ... calibrated with High Molecular Weight calibration kit (GE Healthcare).
-
bioRxiv - Cell Biology 2024Quote: ... with Amersham HMW native marker kit (17044501; GE Healthcare) as a molecular weight marker ...
-
bioRxiv - Cell Biology 2023Quote: ... followed by amplification with the GenomiPhi Kit (GE Healthcare) according to the manufacturer’ s instructions ...
-
bioRxiv - Molecular Biology 2023Quote: ... precipitated and amplified using Illustra TempliPhi kit (GE Healthcare) according to the manufacturer’s instructions ...
-
bioRxiv - Molecular Biology 2024Quote: ... calibrated with High Molecular Weight calibration kit (GE Healthcare). Protein fractions were checked for DNA presence by incubation with DNAse I at 37°C and electrophoresis in 1% agarose 1xTAE gel and ethidium bromide staining.
-
bioRxiv - Cell Biology 2024Quote: ... followed by amplification with the GenomiPhi Kit (GE Healthcare) according to the manufacturer’s instructions ...
-
bioRxiv - Microbiology 2019Quote: ... Viral DNA was extracted from 500-μl subsamples using the Zymo Research Viral DNA kit following the manufacturer’s protocol and subsequently amplified isothermally at 30°C using Genomiphi Whole Genome Amplification Kit (GE Healthcare, Little Chalfont, UK). Samples were cleaned and concentrated using a Zymo Research DNA Clean and Concentrator kit ...