Labshake search
Citations for GE Life Sciences :
801 - 850 of 4592 citations for Recombinant Human FCER2 Protein His Avi tagged Biotinylated since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Molecular Biology 2019Quote: ... Solubilized IBs were purified by immobilized metal affinity chromatography (IMAC) by loading onto a prepacked 1 ml His-Trap HP column (GE Healthcare) equilibrated with lysis buffer containing 8M urea at a flow rate of 1 ml/min using an AKTA-pure-25 FPLC (GE Healthcare) ...
-
bioRxiv - Microbiology 2021Quote: ... The nanobodies were fused with a His-tag at C-terminus and purified over Ni Sepharose 6 Fast Flow (GE Healthcare) and eluted with 400 mM imidazole ...
-
bioRxiv - Molecular Biology 2021Quote: ... with an anti-his-tag mAb (MBL) as the primary and anti-mouse IgG HRP linked whole Ab from sheep (GE Healthcare) as the secondary antibody ...
-
bioRxiv - Immunology 2021Quote: ... to prevent activation of the alternative complement pathway and complement consumption) and anti-FH mAb (35H9) on Hi-Trap HP-NHS columns (GE Healthcare). FH protein was purified from EDTA-plasma using an anti-FH mAb (35H9 ...
-
bioRxiv - Biochemistry 2021Quote: ... The flow-through containing nsp12 was further purified by ion exchange chromatography using Hi TRAP Q HP and SP HP pre-packed columns (GE Healthcare) equilibrated with buffer D ...
-
bioRxiv - Microbiology 2022Quote: ... Size exclusion chromatography was performed in 20 °C ÄKTA purifier system (Amersham) and a prepacked Hi-Prep 16/60 Sephacryl S-200 high-resolution column (GE Healthcare). Flow rate was 0.5 ml/min ...
-
bioRxiv - Systems Biology 2023Quote: ... The lysates were clarified by centrifugation for 1h at 4ºC at 12000 rpm and loaded on a His GraviTrap™ column (GE Healthcare). After washing with 10 mL of washing buffer (40 mM sodium phosphate ...
-
bioRxiv - Immunology 2022Quote: ... His-tagged Fabs were prepared by transient transfection of truncated heavy chain genes encoding a C-terminal 6x-His tag with a light chain expression vector and purified from supernatants using a 5 mL HisTrap colum (GE Healthcare) followed by SEC as described above.
-
bioRxiv - Microbiology 2023Quote: ... Lysate was cleared by centrifugation and the supernatant loaded into an anion exchange column Hi-Trap Sepharose Q-HP (GE Healthcare). KtrA and KtrC were eluted with a 50-1000 mM KCl gradient ...
-
bioRxiv - Plant Biology 2022Quote: ... radioactive signals from His-PIN1L were detected on the dried gel by the Typhoon imaging system (GE Healthcare TYPHOON FLA 9500).
-
bioRxiv - Biochemistry 2023Quote: ... DAP5 was first purified from bacterial cell lysate using a 5 mL His-Trap HP (Ni-NTA) column from GE Healthcare Life Sciences ...
-
bioRxiv - Biochemistry 2023Quote: Protein purification included two steps of immobilized metal-affinity chromatography separated by a thrombin-catalyzed His-tag cleavage and thrombin removal on a heparin column (GE Healthcare), hydrophobic interaction chromatography (HIC ...
-
bioRxiv - Molecular Biology 2023Quote: ... Column was washed with binding buffer and the proteins of interest were eluted with the binding buffer supplemented with 250 mM imidazole and applied to size exclusion chromatography column Hi load 16/60 Sephacryl S-100 column (GE Healthcare). Fractions of interest were pooled ...
-
bioRxiv - Molecular Biology 2023Quote: ... further clarified using 0.2 µm filter and loaded on 5 ml Ni-NTA Sepharose high-affinity pre-packed column (His TrapTM, GE healthcare, Sweden), which was pre-equilibrated with binding buffer (20 mM Tris-Cl ...
-
bioRxiv - Molecular Biology 2023Quote: ... The fusion protein was eluted using binding buffer with 250 mM imidazole and then further purified using size-exclusion chromatography on a Hi load 16/60 Sephacryl S- 100 column (GE Healthcare) in the binding buffer with pH adjusted to 7.4 ...
-
bioRxiv - Molecular Biology 2023Quote: ... To remove any residual impurities final step of size-exclusion chromatography on a Hi load 16/60 Sephacryl S-100 column (GE Healthcare) in the binding buffer with pH adjusted to 7.4 was employed ...
-
bioRxiv - Bioengineering 2023Quote: ... coli lysates by immobilized metal affinity chromatography (IMAC) using a BioRad NGC FPLC equipped with a His-trap FF Ni2+ − NTA column (GE Healthcare). Columns were regenerated fresh with nickel prior to purification of each sample ...
-
bioRxiv - Biochemistry 2022Quote: ... The protein-containing supernatant was collected and filtered through a 0.45 μm size cut-off filter and applied onto a 5 mL His Trap™ crude FF column (GE Healthcare), running in equilibration buffer ...
-
bioRxiv - Microbiology 2023Quote: ... Size exclusion chromatography was performed in 20°C ÄKTA purifier system (Amersham) and a prepacked Hi-Prep 16/60 Sephacryl S-200 high-resolution column (GE Healthcare). Flow rate was 0.5 ml/min ...
-
bioRxiv - Biochemistry 2023Quote: ... Lysate was cleared by centrifugation at 20000g for 45 min and was subjected to 5 ml His-Trap columns (GE Healthcare). The protein was eluted with a linear imidazole gradient of 15–300 mM in 30 column volumes ...
-
bioRxiv - Biophysics 2023Quote: ... Cleaved GST-tag and bZip construct were separated by gel filtration chromatography using Hi-Load 16/600 Superdex 200 pg (GE Healthcare) on AKTA pure in a 20 mM MES pH 6.0 ...
-
bioRxiv - Genetics 2023Quote: ... RAD51 without the His-SUMO tag was then recovered into the flow thru and directly loaded onto a HiTrap heparin column (GE Healthcare). The column was washed with W2 buffer and then a 0.1-1M NaCl gradient was applied ...
-
bioRxiv - Biochemistry 2023Quote: ... 5mM BME) with elution buffer B (buffer A with 500mM Imidazole) on a 5mL His-Trap FF Crude Nickel Column (GE Healthcare). Fractions containing Pol θ were pooled and were separated further on a 5mL HiTrap Heparin HP (GE Healthcare ...
-
bioRxiv - Biochemistry 2023Quote: ... except that purification by size exclusion was omitted and the solubilized inclusion bodies were pre-cleaned by passage over a Hi-Trap Q-Sepharose column (GE Healthcare) before loading onto a Hi-Trap SP-Sepharose column (GE Healthcare) ...
-
bioRxiv - Biochemistry 2023Quote: ... and deletion mutant preps were first diluted tenfold with chromatography buffer before being loaded through a Hi Trap Q XL column (GE Healthcare). A linear gradient of sodium chloride from 0 to 1 M was used to purify the chaperonins where each eluted at a conductivity of 5.5 mS/cm ...
-
bioRxiv - Cell Biology 2023Quote: ... the protein debris was removed by centrifugation (30000×g, 20 min at 4 °C) and the supernatants were applied to His-Trap chelating column (GE Healthcare), washed by refolding buffer and eluted with the same buffer containing 30 mM imidazole ...
-
bioRxiv - Microbiology 2024Quote: ... were injected first onto a His-Trap crude 1 ml column and further purified by FPLC (Äkta purifier-10, GE Healthcare) using a solution of 50 mM Na-Phosphate pH 7.5 ...
-
bioRxiv - Microbiology 2024Quote: ... to reach 120 mM of NaCl and were further passed through a Hi-Trap Q HP 1 mL column to remove residual DNA before binding on a Hi-Trap heparin HP 1 mL column (GE Healthcare) and elution with a NaCl gradient ...
-
bioRxiv - Biophysics 2024Quote: ... the remaining 10 ml of concentrated 6-His-AdhE in buffer A were loaded onto a HiLoad 26/600 Superdex 200 pg column (GE Healthcare) equilibrated with buffer A ...
-
bioRxiv - Biochemistry 2024Quote: ... The middle two layers were removed for subsequent desalting (using five connected Hi-Trap desalting columns (GE Healthcare, Chicago, IL, USA) on an AKTA Pure FPLC system) ...
-
bioRxiv - Developmental Biology 2019Quote: ... 1ml supernatant (2mg protein) was incubated with 30μl Protein G Sepharose (GE Healthcare) for two hours on a rotator at 4°C ...
-
bioRxiv - Biochemistry 2019Quote: ... Proteins were pre-cleared using 40 μl of Protein G Sepharose (GE Healthcare), for 1 hour at 4 °C ...
-
bioRxiv - Neuroscience 2020Quote: ... Soluble Ig-fused proteins were purified using protein A-Sepharose beads (GE Healthcare). Bound proteins were eluted with 0.1 M glycine (pH 2.5 ...
-
bioRxiv - Cell Biology 2022Quote: ... The proteins were further incubated with protein A/G-sepharose beads (GE Healthcare) for 2 hours ...
-
bioRxiv - Biochemistry 2022Quote: ... Fc-fused ACE2 proteins were purified on HiTrap Protein A column (GE Healthcare) and eluted with 50 mM Tris pH 7.2 ...
-
bioRxiv - Immunology 2022Quote: ... fusion protein was purified from cell supernatant using protein A column (GE healthcare). After digestion with TEV protease ...
-
bioRxiv - Immunology 2021Quote: Purified recombinant antibodies were assessed by SDS-PAGE under nonreducing conditions using the Amersham Phastsystem™ (GE Healthcare) according to the manufacturer’s instructions ...
-
bioRxiv - Biophysics 2019Quote: ... Recombinant rhodopsin was purified by affinity chromatography (HisTrap™ FF Crude column, GE Healthcare Life Science, Chicago, IL) and gel filtration (HiPrep™ 26/10 desalting ...
-
bioRxiv - Biochemistry 2022Quote: ... Recombinant Sau-MenD was purified at room temperature by IMAC with 5 mL HisTrap HP columns (GE Healthcare) and an imidazole gradient of 20–500 mM over 50 mL ...
-
bioRxiv - Immunology 2023Quote: ... Recombinant HA molecules were purified from these culture supernatants by FPLC using a HisTrap HP Column (GE Healthcare) and eluted with imidazole gradient ...
-
bioRxiv - Cancer Biology 2022Quote: Human peripheral blood mononuclear cells (PBMC) were purified from human blood buffy coat using Ficoll Paque Plus (GE Healthcare, cat. 17-1440-02) reagent and CD14+ microbeads (MACS Miltenyi Biotec ...
-
bioRxiv - Pharmacology and Toxicology 2021Quote: Recombinant 6xHis-tagged mouse GRP78 was expressed in E coli BL21 cells and purified on a HisTrap™ HP Nickel column (GE healthcare, Uppsala, Sweden). Twenty micrograms (0.3 nmol ...
-
bioRxiv - Biophysics 2020Quote: ... the AF555- or AS635P-conjugated and biotinylated H57-scFVs were purified by gel filtration using Superdex 75 (10/300 GL, GE Healthcare Life Sciences). Fractions containing monomeric ...
-
bioRxiv - Bioengineering 2019Quote: ... i) Aptamer selection using biotinylated HGM-box that were immobilized on streptavidin-coated magnetic beads (Streptavidin Mag Sepharose™ from GE Healthcare, USA). The bead binding capacity for either HMG-box Pf or HMG-box Hs was estimated to19 pmol/μL beads slurry ...
-
bioRxiv - Cell Biology 2022Quote: The real time protein-protein interaction of protease and PDZ domain proteins of PfHtrA2was analysed by SPR using Biacore T200 instrument (GE Healthcare, Uppsala, Sweden) as described previously [7] ...
-
bioRxiv - Developmental Biology 2021Quote: ... Extracted proteins were immunoprecipitated with Protein A Sepharose CL-4B beads (GE Healthcare, USA) and desired primary antibodies ...
-
bioRxiv - Cell Biology 2021Quote: Protein purification was carried out with the AKTA-prime protein purification system (GE Healthcare). First ...
-
bioRxiv - Biochemistry 2020Quote: ... Proteins were purified from supernatants by protein A affinity chromatography using ÄKTA (GE Healthcare) or NGC (Bio-Rad ...
-
bioRxiv - Microbiology 2020Quote: ... S1 -Fc proteins were purified using Protein A-Sepharose beads (GE Healthcare Life sciences) following the manufacturer’s instructions ...
-
bioRxiv - Microbiology 2021Quote: ... The protein-antibody complexes were captured with protein-G coupled Sepharose beads (GE Healthcare) by incubation at 4 °C for 1 h ...