Labshake search
Citations for GE Life Sciences :
651 - 700 of 5309 citations for 7 7a Dihydro 2 2 4 6 6 pentamethyl 1 3 benzodioxol 5 6H one since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Molecular Biology 2019Quote: ... and applied to a Superdex 200 16/600 or a Superose 6 10/300 column (GE Healthcare) equilibrated in 50 mM Hepes ...
-
bioRxiv - Molecular Biology 2019Quote: ... The lysate was passed over a self-packed Ni2+-charged IMAC Sepharose 6 Fast Flow (GE Healthcare) column ...
-
bioRxiv - Biochemistry 2020Quote: ... and injected on to a Superose 6 10/300 Increase GL size-exclusion chromatography column (GE Healthcare) equilibrated in 20 mM HEPES pH 7.5 ...
-
bioRxiv - Cell Biology 2020Quote: ... Ion exchange chromatography was performed using either 6 ml RESOURCE S or RESOURCE Q column (GE Healthcare) pre-equilibrated with 5% of buffer B (25 mM HEPES pH 7.5 ...
-
bioRxiv - Cell Biology 2021Quote: ... Then the mixture was subjected to gel filtration chromatography (Superose 6 Increase 10/300 GL, GE Healthcare) in buffer containing 25 mM Tris (pH 8.0) ...
-
bioRxiv - Biochemistry 2021Quote: ... 250 mM imidazole) and subsequently by gel filtration using a Superose 6 16/60 column (GE Healthcare) equilibrated with 50 mM HEPES-NaOH pH 7.2 ...
-
bioRxiv - Molecular Biology 2020Quote: ... The proteins were purified by Ni-NTA IMAC using Ni-Sepharose 6 Fast Flow resin (GE Healthcare). The wash buffer consisted of 50 mM Tris ...
-
bioRxiv - Immunology 2020Quote: ... The purified protein was run over a 10/300 Superose 6 size-exclusion column (GE Life Sciences). Fractions containing the trimeric HPIV3 F proteins were pooled and concentrated by centrifugation in an Amicon ultrafiltration unit (Millipore ...
-
bioRxiv - Cell Biology 2021Quote: ... The protein was purified from cleared cell lysate using Ni-sepharose 6 Fast flow resin (GE Healthcare) in a poly-prep column (Bio-Rad) ...
-
bioRxiv - Microbiology 2021Quote: ... and followed by Superose 6 10/300 gel filtration column chromatography (GE Healthcare, Cat# 17-5172-01). Proteins were then concentrated and the concentrations were determined using BCA protein concentration kit (Pierce ...
-
bioRxiv - Cell Biology 2021Quote: ... A final anion exchange purification step was performed using a Resource Q 6 ml column (GE Healthcare), using 50 mM Tris HCl pH 8 ...
-
bioRxiv - Biochemistry 2022Quote: Recombinant CrRPE1 was injected on a Superose 6 Increase 10/300 GL column (GE Healthcare, Chicago, Illinois) and isocratically eluted in 50 mM Tris-HCl (pH 7.5 ...
-
bioRxiv - Biophysics 2022Quote: ... The pooled eluate containing TRiC was further purified through size-exclusion chromatography (Superose 6 increase, GE Healthcare) and then concentrated with a Millipore Ultrafree centrifugal filter device (100-kDa cutoff).
-
bioRxiv - Cell Biology 2022Quote: ... Fractions containing GST-protein were pooled and loaded to a 6 mL Resource S column (GE Healthcare) equilibrated with buffer B ...
-
bioRxiv - Microbiology 2023Quote: ... The mixture was resolved by gel filtration chromatography on a Superose 6 10/300 column (GE Healthcare) in buffer A ...
-
bioRxiv - Plant Biology 2023Quote: ... Recombinant CaM was purified using phenyl-sepharose resin (Phenyl Sepharose® 6 Fast Flow, GE Healthcare Inc.) as described (Bender et al. ...
-
bioRxiv - Biochemistry 2022Quote: ... The samples were concentrated to 100 µL and purified by SEC (Superose 6 30/100, GE Healthcare) at 4 °C ...
-
bioRxiv - Biophysics 2023Quote: ... and purified by size exclusion chromatography (SEC) using a Superose 6 Increase 10/300 column (GE Healthcare) pre-equilibrated with SEC buffer containing 50 mM HEPES (pH 6.5 with KOH) ...
-
bioRxiv - Bioengineering 2023Quote: ... The supernatant was loaded onto a Superose-6 Increase 10/300GL size exclusion column (GE Healthcare/Cytiva) equilibrated with 40 mM HEPES pH 7.5 ...
-
bioRxiv - Microbiology 2023Quote: ... The samples were then injected over a gel filtration column (Superose 6 10/30, GE Life Sciences) equilibrated with 20mM Tris pH 8.0 and 150mM NaCl ...
-
bioRxiv - Biochemistry 2023Quote: ... The concentrated sample was then purified by gel filtration on a Superose-6 Increase column (GE Healthcare) equilibrated with the same buffer used for the buffer exchange ...
-
bioRxiv - Biochemistry 2023Quote: ... Excess of polysulfide or DTT was removed with micro Bio-Spin 6 columns (GE Healthcare, Munich, Germany) equilibrated with 50 mM Tris-HCl pH 7.5 ...
-
bioRxiv - Biochemistry 2024Quote: ... and then loaded onto a Superose™ 6 Increase 10/300 GL column (GE Healthcare Life Sciences), in buffer containing 150 mM NaCl ...
-
bioRxiv - Biochemistry 2024Quote: ... The eluent was further purified by SEC using a Superose 6 increase 10/300 column (GE Healthcare) pre-equilibrated with buffer containing 25 mM HEPES pH 7.5 ...
-
bioRxiv - Microbiology 2023Quote: ... of which 450 µl were subjected to isoelectric focusing on pH 4-7 IPG strips (GE Healthcare), followed by SDS-PAGE with 12 % acrylamide gels ...
-
bioRxiv - Neuroscience 2020Quote: ... 150 mM NaCl) containing 5% skim milk (Meiji) and subjected to primary antibody for 2 h and HRP-conjugated secondary antibody (GE Healthcare) for 30 min ...
-
bioRxiv - Biophysics 2021Quote: ... Peak fractions were pooled, diluted ~5 fold with buffer 0 (20 mM HEPES, 2 mM DTT) and loaded onto a Q column (GE Healthcare). Rad33 was then eluted from the Q column using a linear gradient of Q buffer A (20 mM HEPES ...
-
bioRxiv - Microbiology 2020Quote: ... Aliquots were taken every 30 minutes for a period of 2 hours and quenched in 3ml of 5% trichloroacetic acid (TCA) on Whatman-glass fiber filters (GE healthcare) and washed 3 times with 1ml ethanol to dry the filter ...
-
Bridging of nucleosome-proximal DNA double-strand breaks by PARP2 enhances its interaction with HPF1bioRxiv - Biochemistry 2019Quote: ... diluted by half to lower NaCl concentration to 250 mM and applied at 2 mL/min onto a HiTrap Heparin HP 5 mL column (GE Healthcare) previously equilibrated in Tris 50 mM ...
-
bioRxiv - Cell Biology 2019Quote: ... the primary antibody was visualized using 2~5 μg/ml secondary antibody towards specific species of primary antibody labeled with Cy3B (GE Healthcare) or Atto 488 (Sigma-Aldrich ...
-
bioRxiv - Biophysics 2023Quote: ... The sample was then diluted with dilution buffer (50 mM HEPES (pH 7.2) and 5% glycerol) to reduce the salt concentration and loaded onto a Mono S 10/100 GL column (GE Healthcare). The column was washed with buffer C (50 mM HEPES (pH 7.2) ...
-
bioRxiv - Biochemistry 2023Quote: ... plate 2 - 1.6 μg/μL carboxylate beads (1:1 mixture of hydrophilic and hydrophobic beads [mass/mass], GE Healthcare Cat ...
-
bioRxiv - Biochemistry 2023Quote: ... The sample was concentrated to 2-3 mL for separation on exclusion size chromatography (HiLoad 16/600 SuperdexTM 75pg, GE Healthcare; ÄKTA Avant). Finally ...
-
bioRxiv - Immunology 2020Quote: ... Dilution series of TBK1 or IRF-3 (1.25, 2.5, 5, 10, 20 μM) in 1× HBS-EP+ buffer (GE Healthcare) were injected over the sensor chip at a flow rate of 30 μL/min ...
-
bioRxiv - Immunology 2020Quote: Total IgG1 antibodies were captured from 2 µL of serum using Protein G Sepharose 4 Fast Flow beads (GE Healthcare, Uppsala, Sweden) in a 96-well filter plate (Millipore Multiscreen ...
-
bioRxiv - Immunology 2019Quote: Total IgG antibodies were captured from 2 µL of plasma using Protein G Sepharose 4 Fast Flow beads (GE Healthcare, Uppsala, Sweden) in a 96-well filter plate (Millipore Multiscreen ...
-
bioRxiv - Cell Biology 2020Quote: ... 2) the reaction mix was purified using anion exchange column (HiTrap QFF 1 mL; GE Healthcare); 3 ...
-
bioRxiv - Cancer Biology 2021Quote: ... and after 1 and 2 days of co-culture on an INCell Analyzer 2200 (GE Healthcare), with a large field-of-view sCMOS camera (resolution 2048×2048 pixels ...
-
bioRxiv - Microbiology 2021Quote: ... 2 mM β-mercaptoethanol) and applied to a 1-ml Hi-Trap Heparin column (GE Healthcare) equilibrated with TGED ...
-
bioRxiv - Neuroscience 2020Quote: The two animals (Monkey 1 and Monkey 2) were scanned on a Discovery MI (GE Healthcare) PET/CT scanner ...
-
bioRxiv - Biophysics 2021Quote: ... the samples were subjected to size- exclusion chromatography using a Superose 6 10/300 GL column (GE Healthcare). For each sample ...
-
bioRxiv - Biochemistry 2020Quote: ... centrifugal filter unit and injected onto a Superose 6 Increase 10/300 GL size exclusion column (GE Healthcare) pre-equilibrated in TBS plus 0.01% (w/v ...
-
bioRxiv - Microbiology 2020Quote: ... Spike variants were further purified by size-exclusion chromatography using a Superose 6 10/300 column (GE Healthcare) in a buffer composed of 2 mM Tris pH 8.0 ...
-
bioRxiv - Cell Biology 2020Quote: ... were added at 25ul/ml to exclude immune and endothelial cells using MagRack 6 (GE Healthcare 89129-096). Cells were either frozen for future use or stained for flow cytometry ...
-
bioRxiv - Immunology 2022Quote: ... Further purification was carried out using size-exclusion chromatography with a Superose 6 10/300 column (GE Healthcare) in the buffer containing 20 mM HEPES pH 7.2 ...
-
bioRxiv - Biophysics 2020Quote: ... The eluted protein sample was concentrated and applied to gel filtration (Superose 6 10/300 GL, GE Healthcare) in running buffer (25 mM HEPES pH 7.4 ...
-
bioRxiv - Biochemistry 2020Quote: ... TSEN-containing fractions were pooled and loaded onto a Superose 6 Increase 10/300 GL column (GE Healthcare) pre-equilibrated in purification buffer ...
-
bioRxiv - Biochemistry 2021Quote: ... spikes were further purified by size-exclusion chromatography using a Superose 6 Increase 10/300 column (GE Healthcare).
-
bioRxiv - Bioengineering 2020Quote: ... Complexes were purified on a Superose 6 Increase 10/300 column using an Äkta Pure system (GE Healthcare) in TBS buffer ...
-
bioRxiv - Cancer Biology 2021Quote: Gel filtration experiments were performed using Superose® 6 Increase 10/300 GL size exclusion column (GE Healthcare) ÄKTA pure protein purification system (Cytiva) ...