Labshake search
Citations for GE Life Sciences :
501 - 550 of 6926 citations for Human Fibrinogen C Domain Containing Protein 1 FIBCD1 ELISA Kit since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Bioengineering 2020Quote: ... Supernatants were collected by centrifugation and purified using a 1 ml HiTrap Protein A HP column (GE Healthcare) for IgG expression and 5 ml kappa-select column (GE Healthcare ...
-
bioRxiv - Cell Biology 2021Quote: ... 1 mM DTT with USP7 proteins purified as described previously 62 using Glutathione Sepharose 4B beads (GE Healthcare). After elution the GST tag was removed under dialysis using 3C protease and the sample fractionated by PorosXQ anion exchange (Thermo Fisher Scientific) ...
-
bioRxiv - Microbiology 2021Quote: ... and the soluble MED25 ACID protein was purified on 1 ml beads loaded with Ni-NTA (GE Healthcare). The bound protein was washed extensively with loading buffer containing 25 mM imidazole and eluted with a 250 mM imidazole pH 8.
-
bioRxiv - Cell Biology 2021Quote: ... DNA fragments encoding APC proteins were inserted into pGEX-5X-1 (GE Healthcare Life Sciences, Pittsburgh, PA, USA). For in vitro transcription and translation reaction ...
-
bioRxiv - Immunology 2020Quote: ... run at a flow rate of 0.5-1 mL/min on Äkta Start protein purification system (GE Healthcare). Antibodies were eluted using 0.1M glycine pH 2 ...
-
bioRxiv - Physiology 2022Quote: ... The specific proteins were detected with horseradish peroxidase (HRP) conjugated secondary antibodies (1:5000 dilution; CtNo_NA934, GE Healthcare, 1:5000 dilution ...
-
bioRxiv - Cell Biology 2020Quote: ... Proteins were detected with secondary antibodies conjugated to horseradish peroxidase (RPN4201 and RPN4301) and the ECL detection kit (both GE Healthcare). Visualization of protein bands was realized by LAS-4000 mini (Fujifilm) ...
-
bioRxiv - Cell Biology 2019Quote: ... The column was calibrated with protein standards of known molecular weight and stokes’ radius (Low and High Molecular Weight Kit, GE Healthcare) according to manufacturer’s protocol.
-
bioRxiv - Biophysics 2022Quote: ... Protein concentration of the extracts were determined by SDS-PAGE and densitometry analysis using the LMW-SDS Marker Kit (GE Healthcare) as standard.
-
bioRxiv - Pharmacology and Toxicology 2022Quote: ... Proteins were detected by fluorescence (Odyssey, Li-Cor) or revealed using the ECL Prime Western Blotting Detection Reagent kit (GE Healthcare) and images were acquired in a dark room using a G:Box (Syngene ...
-
bioRxiv - Zoology 2019Quote: The midgut BBMV proteins were subjected to clean-up using the 2-D Clean-up Kit (GE Healthcare Life Sciences, USA) as per the manufacturer’s instructions ...
-
bioRxiv - Cell Biology 2019Quote: ... phenolics and nucleic acids in extracted protein were removed using the 2-D Clean-Up kit (GE Healthcare, Piscataway, NJ, USA) according to the manufacturer’s instructions ...
-
bioRxiv - Cancer Biology 2022Quote: Human peripheral blood mononuclear cells (PBMC) were purified from human blood buffy coat using Ficoll Paque Plus (GE Healthcare, cat. 17-1440-02) reagent and CD14+ microbeads (MACS Miltenyi Biotec ...
-
bioRxiv - Biochemistry 2020Quote: ... The lysate was clarified by centrifugation (15000 rpm for 1 h at 4 °C) and incubated with glutathione Sepharose 4B (GE Healthcare) for 4 h at 4 °C ...
-
bioRxiv - Cell Biology 2020Quote: ... The complex was supplied with 2mM GTP and incubated at 4°C for 1 hour prior to purification by size exclusion chromatography on a HiLoad Superdex S75 16/600 column (GE Healthcare) equilibrated in 50mM Tris-HCl pH 8.0 ...
-
bioRxiv - Molecular Biology 2020Quote: ... The lysate was then cleared by centrifugation (18000 g, 4 °C, 1 hour) and purified using a HisTrap HP 5 ml column (GE Healthcare) and a 10-100 mM imidazole linear gradient followed by elution with 250 mM imidazole ...
-
bioRxiv - Biochemistry 2019Quote: ... Cell debris was removed by centrifugation at 10000xg for 45 min at 4°C and the supernatant was loaded onto either a 1 mL or 5 mL HisTrap FF crude column (GE Healthcare) equilibrated in Ni-1 buffer using a peristaltic pump ...
-
bioRxiv - Genomics 2019Quote: ZHBTc4 YPet-MD TIR1-V5 mCherry-OCT4-AID cells were plated in a 96-well plate coated for 1 hour at 37°C with 1:25 diluted StemAdhere (Primorigen Biosciences #S2071-500UG) and imaged on an IN Cell Analyzer 2200 (GE Healthcare) using the TexasRed and Brightfield channels ...
-
bioRxiv - Biochemistry 2021Quote: ... The lysate was clarified by centrifugation at 12000 g at 4 °C for 1 h and loaded onto a HisTrap HP column (GE Healthcare) equilibrated with 98% buffer A/2% buffer B (20 mM Tris ...
-
bioRxiv - Bioengineering 2021Quote: ... The reaction mixture was incubated at 37°C for 1 h and labeled EVs purified using a PD-10 size exclusion chromatography column (GE Healthcare). Instant thin layer chromatography (iTLC ...
-
bioRxiv - Systems Biology 2020Quote: ... Lysates were then centrifuged at 20,000 g for 20 min at 4°C and the supernatant loaded to a GSTrap FF 1 mL column (GE Healthcare). Following a washing step with 10 mL GST-Buffer ...
-
bioRxiv - Microbiology 2022Quote: ... cleavage was achieved after elution of GbpA from the column by adding 1 unit of PreScission protease enzyme and incubation overnight at 4°C per the instructions of the manufacturer (GE Healthcare).
-
bioRxiv - Microbiology 2022Quote: IVTT reaction mixtures (100 µl) were incubated at 4 °C for 1 h with a 50% slurry of PBS/Glutathione-Sepharose 4B (GE Healthcare) with gentle mixing ...
-
bioRxiv - Biochemistry 2022Quote: ... The soluble fraction was separated by further centrifugation at 13 000 x g for 1 h at 4 °C and the supernatant was loaded onto a 5 mL HisTrap FF NiNTA column (GE Healthcare) equilibrated with lysis buffer ...
-
bioRxiv - Biochemistry 2020Quote: ... Lysates were clarified by centrifugation at 50,000 × g for 1 h at 4 °C and the supernatant was used for affinity purification on HisTrap FF columns (GE Healthcare) according to the manufacturer’s instructions ...
-
bioRxiv - Biochemistry 2020Quote: ... the His6-tagged 14-3-3ε was allowed to equilibrate with the excess of untagged 14-3-3γ (overnight at 4 °C) and then loaded on a 1 ml HisTrap HP column (GE Healthcare) while the flowthrough fraction containing 14-3-3γ was collected ...
-
bioRxiv - Cell Biology 2020Quote: ... and incubated for 1 h at 4 °C and purified on a Superose 6 Increase 10/300 GL column (GE Healthcare) equilibrated with 25 mM sodium phosphate pH7.4 ...
-
bioRxiv - Physiology 2020Quote: ... Blots were then washed in TBST and incubated for 1 h at 22-24°C with secondary HRP-conjugated antibodies (GE Healthcare) diluted 5000-fold in 5% skim milk in TBST ...
-
bioRxiv - Biochemistry 2021Quote: ... purified OxlT was mixed with purified 20D033-Fv at a 1:2 molar ratio at 4 °C overnight and purified using Superdex200 Increase 10/300 GL (GE healthcare) in 20 mM MES-KOH ...
-
bioRxiv - Molecular Biology 2021Quote: ... 0.2% Triton X-100) and incubated 1 hour at RT or 16 hours at 4°C with HRP-coupled streptavidin (RPN1231VS, GE Healthcare) diluted 1:20000 in BSA blocking buffer ...
-
bioRxiv - Cell Biology 2021Quote: ... and GST-SV40-NLS were cloned by in-frame insertion of the corresponding NFAT5 fragments and SV40-NLS into the C-terminus of GST of pGEX-4T-1 (GE Healthcare), respectively ...
-
bioRxiv - Biochemistry 2021Quote: ... Lysates were cleared for 30 min at 12,500 × g at 4°C and the supernatant was collected and fractionated on a 1 ml Q-HiTrap column (GE Healthcare) equilibrated in 20 mM Tris ...
-
bioRxiv - Synthetic Biology 2022Quote: ... The lysates were clarified by centrifugation at 20 000 × g for 1 hour at 4 °C before loading on a 5 mL HiTrap FF Ni-NTA column (GE Healthcare) equilibrated with lysis buffer ...
-
bioRxiv - Plant Biology 2022Quote: ... coli strain BL21 with protein induction when OD600 reached 0.5 with 1 mM IPTG (isopropyl b-D-1-Thiogalactopyranoside) for 4 h at 37°C and then purified over a glutathione Sepharose 4B column (GE Healthcare). The eluted samples were then resolved by SDS-PAGE and stained by Coomassie brilliant blue R-250 to evaluate purity ...
-
bioRxiv - Biochemistry 2022Quote: ... The suspension was clarified by centrifugation at 30,000 x g (Sorval SLA 1500) at 4 °C for 30 min and loaded onto a 1 ml HisTrap HP column (GE Healthcare) on an ÄKTA purifier 10 system (GE Healthcare) ...
-
bioRxiv - Biochemistry 2023Quote: ... Lysates were clarified by centrifugation at 50,000 × g for 1 h at 4 °C and the supernatant was used for affinity purification on HisTrap FF columns (GE Healthcare) according to the manufacturer’s instructions ...
-
bioRxiv - Microbiology 2023Quote: ... The clarified lysate was incubated (overnight, at 4 °C, with gentle agitation) with 1 ml bed volume of GSH-Sepharose (GE Healthcare). Next ...
-
bioRxiv - Biochemistry 2023Quote: ... Insoluble fractions were removed by centrifugation at 20000 g during 30 min at 4°C and the supernatant was loaded on a 1 mL HisTrapTM HP column (GE Healthcare) connected to a NGC chromatography system (BioRad) ...
-
bioRxiv - Biochemistry 2023Quote: ... the supernatant clarified from the cell lysate after overnight induction by 0.5mM isopropylthio-β-D-1-galactopyranoside (IPTG) at 20 °C was applied to pre-equilibrated 5Lml HisTrap column (GE Healthcare). After thorough wash with binding buffer (20LmM Tris–HCl pHL7.4 ...
-
bioRxiv - Molecular Biology 2024Quote: ... The cleared lysate was rotated for 1 h at 4 °C in presence of 50 µL of streptavidin sepharose (50% slurry, GE Healthcare). Beads were washed three times with NET buffer ...
-
bioRxiv - Neuroscience 2022Quote: ... The supernatant containing the cells was filtered through 70-μm strainers into a tube containing 90% isotonic Percoll (GE Healthcare, #17-0891-01 ...
-
bioRxiv - Cell Biology 2023Quote: ... Membranes were washed with TBS containing 0.1% polysorbate-20 and then incubated in blocking buffer containing horseradish peroxidase-conjugated secondary antibodies (GE Healthcare) for 1 hour at room temperature ...
-
bioRxiv - Microbiology 2021Quote: ... PCR elongation was performed at 72 °C (2 min per kb) and the amplified products were purified by illustra GFX purification kit (GE Healthcare Little Chalfont, UK).
-
bioRxiv - Cell Biology 2022Quote: ... containing 10% bovine calf serum (GE Healthcare SH30072.03), 2 mM L-glutamate along with penicillin and 100 μg/ml streptomycin (Wisent 609065 ...
-
bioRxiv - Biochemistry 2019Quote: ... containing an N-terminal PreScission protease (GE Healthcare) cleavable His6-tag prior to MCS 1 ...
-
bioRxiv - Biophysics 2022Quote: ... and analysed by electrophoresis in a blue native gel containing 4 - 16% gradient of acrylamide (29:1 Acrylamide:Bis) using the SE 600 Vertical electrophoresis system (GE Healthcare Life Sciences). The gels were run at 4 °C at constant 200 V for 2 h followed by 6 h at 600 V with max ...
-
bioRxiv - Bioengineering 2019Quote: ... The supernatant was collected for purification using a 1 mL His Trap™ FF Crude Column containing Ni-NTA (GE Healthcare, USA). Briefly ...
-
bioRxiv - Molecular Biology 2022Quote: ... CaM was eluted in buffer containing 1 mM EDTA then further purified using anion exchange with a Resource Q column (GE Life Sciences) before dialysis into water and lyophilization in a vacuum concentrator.
-
bioRxiv - Neuroscience 2022Quote: ... plasma or CSF probes were incubated in 25 μl for 1 hour at room temperature (diluted with PBS containing 5% Amersham ECL Blocking Agent, GE Healthcare RNP2125), followed by additional washing steps and incubation with an anti-mouse secondary antibody conjugated with the MSD Sulfo-tag for detection ...
-
bioRxiv - Biochemistry 2019Quote: His6-tagged proteins were purified by binding proteins to Ni-NTA columns (GE Healthcare) in buffer D (50 mM Tris pH 8.0 ...