Labshake search
Citations for Sciex :
601 - 650 of 768 citations for TOF Mass Spectrometers since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Plant Biology 2019Quote: ... analysis was carried out as described in67 and phytohormones were ionized in a negative mode and determined in a scheduled multiple reaction monitoring mode with an AB Sciex 4000 QTRAP® tandem mass spectrometer (AB Sciex, Framingham, MA, USA). Mass transitions are described in Supplementary Table 5.
-
bioRxiv - Microbiology 2019Quote: ... The eluate from the LC was delivered directly to the TurboV source of a TripleTOF 5600+ mass spectrometer (AB Sciex, Foster City, CA, USA) using electrospray ionization (ESI ...
-
bioRxiv - Cell Biology 2022Quote: ... for global metabolomics analysis and Shimadzu Nexera HPLC series system connected to triple quadrupole mass spectrometer with linear ion trap (QTRAP 6500®, AB Sciex Instruments, CA, USA) for targeted metabolomics analysis ...
-
bioRxiv - Cell Biology 2022Quote: ... samples were injected by auto-sampler (Dionex Corporation, CA) onto an HPLC column in line with a triple-quadrupole mass spectrometer (AB Sciex 5500Qtrap, Toronto, ON, Canada). Metabolites were separated through a guard column (Inertsil ODS-3 ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: POA was quantified using an LC-MS/MS system consisting of AB-Sciex API 3200 triple-quadrupole mass spectrometer (AB SCIEX, Foster City, CA, US) with an Agilent 1100 HPLC system (Agilent Technologies ...
-
bioRxiv - Biochemistry 2023Quote: ... LC-MS/MS analyses were performed using a Water ACQUITY HPLC system coupled with a QTRAP® 6500+ mass spectrometer (AB SCIEX, Framingham, MA, USA). Samples were injected onto a Water HSS T3 (2.1 × 100 mm ...
-
bioRxiv - Biophysics 2021Quote: ... And then we determine the resulting peptides with Sciex 5600 triple tof (AB SCIEX) and analyze them using the ProteinPilot software.
-
bioRxiv - Cell Biology 2020Quote: ... Data acquisition was performed with a Triple TOF 5600 System (AB SCIEX, Concord, ON). For database searching ...
-
bioRxiv - Biochemistry 2021Quote: ... and analyzed by nanoESI (TriVersa Nanomate®; Advion BioSciences, Ithaca, NY, USA) coupled with an AB Sciex 6500 QTRAP® tandem mass spectrometer (AB Sciex, Framingham, MA, USA) employed in scheduled multiple reaction monitoring mode ...
-
bioRxiv - Biochemistry 2021Quote: ... and analysed by nanoelectrospray ionization (nanoESI) (TriVersa Nanomate®; Advion BioSciences, Ithaca, NY, USA) coupled with an AB Sciex 4000 QTRAP® tandem mass spectrometer (AB Sciex, Framingham, MA, USA) employed in scheduled multiple reaction monitoring mode (Herrfurth and Feussner 2020) ...
-
bioRxiv - Pharmacology and Toxicology 2024Quote: An Acquity Ultra-Performance liquid chromatography (UPLC) system (Waters Corp., Milford, MA, USA) coupled to a triple quadrupole mass spectrometer (API 4000™, AB Sciex, Foster City, CA, USA) was used for the analysis.
-
bioRxiv - Cell Biology 2022Quote: Analysis of lipid related molecules was performed using a Triple TOF 6600 system (AB SCIEX) in the negative and positive ion mode with a scan range of m/z 70-1,250 ...
-
bioRxiv - Animal Behavior and Cognition 2021Quote: ... coupled with a quadrupole time of-flight system (AB Sciex Triple TOF 6600, AB SCIEX) at Shanghai Applied Protein Technology Co. ...
-
bioRxiv - Animal Behavior and Cognition 2021Quote: ... coupled with a quadrupole time of-flight system (AB Sciex Triple TOF 6600, AB SCIEX) at Shanghai Applied Protein Technology Co. ...
-
bioRxiv - Plant Biology 2021Quote: ... LC-TOF-MS was performed using the AB Sciex Tripletof 6600 (AB Sciex, Milford, MA, USA) in a positive ionization mode.
-
bioRxiv - Biochemistry 2023Quote: ... Peptides were analyzed using a Sceix Zeno TOF 7600 (AB Sciex, Foster City, CA, United States) equipped with a Shimadzu LC 40 UPLC system ...
-
bioRxiv - Microbiology 2024Quote: ... Mass calibration was performed with a peptide mass standards kit (AB SCIEX) or with a purified and structurally characterized LPS sample from Bordetella pertussis.
-
bioRxiv - Biochemistry 2020Quote: ... that was externally calibrated using the Calmix 5 Opti-ToF High-Resolution TIS Calibration Insert (AB Sciex). The mMass - Open Source Mass Spectrometry Tool (Version 5.5.0 ...
-
bioRxiv - Biochemistry 2020Quote: ... that was calibrated externally using the Calmix 5 Opti-ToF High-Resolution TIS Calibration Insert (AB Sciex). N-glycan assignments were carried out using GlycoWorkbench software [32].
-
bioRxiv - Systems Biology 2024Quote: ... whereas MS detection was performed by the Q-TOF instrument in (−) ionization mode (TurboIonSpray; AB Sciex LLC). The curtain gas was set to 30 psi ...
-
bioRxiv - Biochemistry 2023Quote: ... SWATH-DIA methods were developed using TOF MS data and SWATH Variable Window Calculator provided by SCIEX. Collision Energy (CE ...
-
bioRxiv - Synthetic Biology 2021Quote: ... MALDI-TOF analysis was performed with a 4800 Proteomics Analyzer (Applied Biosystems/MDS Sciex, Forster City, CA, USA) using the 4800 Series Explorer software (positive-ion reflector mode in a mass range from 800 to 2500 Da) ...
-
bioRxiv - Biochemistry 2019Quote: ... Higgins Analytical) with a H2O (0.1% TFA)/MeCN (0.1% TFA) elution gradient and MALDI-TOF MS (AB Sciex Voyager DE-PRO MALDI TOF or 4700 MALDI TOF/TOF)(Table S1 ...
-
bioRxiv - Biophysics 2021Quote: ... we measure the molecular weight of the Aβ oligomers with MS using the Sciex 5600 triple tof (AB SCIEX). Then ...
-
bioRxiv - Molecular Biology 2021Quote: ... 2 % acetonitrile solution (final volume = 10 µl) to run on LC-MS/MS (Triple-TOF 6600 system, SCIEX®).
-
bioRxiv - Microbiology 2022Quote: ... Contezolid and its metabolites were detected using a triple TOF 5600+ MS/MS system (AB Sciex, Concord, Ontario, Canada) in the positive electrospray ionization mode ...
-
bioRxiv - Plant Biology 2019Quote: ... The LC-MS/MS analysis was performed by Triple TOF™ 5600 LC-MS/MS (AB Sciex Inc., Concord, Canada) according to Zhao et al ...
-
bioRxiv - Immunology 2022Quote: ... The samples were resuspended in 100 µl of water prior to metabolomics analysis performed by HPLC-Triple-TOF/MS instrument (AB Sciex), and 20 µl was used for analysis.
-
bioRxiv - Biochemistry 2019Quote: ... TOF MS spectra and TOF MS/MS spectra were automatically calibrated during dynamic LC-MS & MS/MS autocalibration acquisitions injecting beta-galactosidase (AB SCIEX). Automatic re-calibration of TOF-MS and TOF-MS/MS scans (after every 1-3 samples ...
-
The antibiotic bedaquiline activates host macrophage innate immune resistance to bacterial infectionbioRxiv - Immunology 2019Quote: ... corresponding to ∼100–1000 cells per well of the MALDI target plate (384 Opti-TOF 123 mm × 84 mm, AB Sciex), and 0.6 µL of the matrix solution were deposited on the MALDI target plate ...
-
bioRxiv - Molecular Biology 2020Quote: ... The peptides were separated on Eksigent nano-LC (Ultra 2D) coupled with 5600 triple time-of-flight (TOF) (AB Sciex). Details of the proteomics experiment and preliminary analysis protocols are in Supplementary Methods ...
-
bioRxiv - Cancer Biology 2020Quote: ... TOF MS spectra and TOF MS/MS spectra were automatically calibrated during dynamic LC-MS & MS/MS autocalibration acquisitions injecting beta-galactosidase (AB SCIEX). Automatic re-calibration of TOF-MS and TOF-MS/MS scans (after every 1-3 samples ...
-
bioRxiv - Developmental Biology 2021Quote: ... The peptides were electrosprayed using a nanoelectrospray ionization source at an ion spray voltage of 2300 eV and analyzed by a NanoLC-ESI-Triple TOF 5600 system (AB Sciex). Protein identification was based on a threshold protein score of > 1.0 ...
-
bioRxiv - Biochemistry 2020Quote: ... The tryptic peptides corresponding to each sample were labeled with its unique iTRAQ tags and proteomics analysis was conducted using a Triple TOF 6600 system (AB SCIEX). The data were analyzed by Novogene.
-
bioRxiv - Plant Biology 2022Quote: ... USA) with an AB Triple TOF 5600 plus System was used for the MS analysis (AB SCIEX, Framingham, MA, USA). The optimum MS conditions were as follows ...
-
bioRxiv - Plant Biology 2023Quote: Cleavage sites of the peptide fragment of FER from Ser-487 (S487) to Phe-526 (F526) (Named FER-IJM) was determined by MALDI-TOF MS (AB SCIEX TOF/TOF TM 5800 system ...
-
bioRxiv - Microbiology 2021Quote: High resolution MS spectra were recorded at Unitech OMICs (University of Milano, Italy) using a Dionex Ultimate 3000 HPLC system coupled with a Triple TOF® 6600 (Sciex) equipped with an ESI source ...
-
bioRxiv - Genetics 2020Quote: ... and 1 μL injected on a liquid chromatography system nLC Ekspert nanoLC400 (Eksigent, 5033460C; Singapore) coupled with a Triple TOF 6600 (AB Sciex; Singapore). Chromatography was performed using an in house packed nanocolumn Kinetex EVO C18 ...
-
bioRxiv - Physiology 2020Quote: ... and analyzed with mass spectrometry (MDS SCIEX 4000 Q Trap ...
-
bioRxiv - Immunology 2021Quote: ... corresponding to ~100–1000 cells per well of the MALDI target plate (384 Opti-TOF 123 mm × 84 mm AB Sciex NC0318050, 1016629), and 0.8 μL of the matrix solution were deposited on the MALDI target plate ...
-
bioRxiv - Pharmacology and Toxicology 2020Quote: ... The small molecules were separated with Agilent 1290 Infinity LC and their mass were examined with 5500 QTRAP mass (AB SCIEX). The data was analyzed with the MultiQuant software program against the standards.
-
bioRxiv - Neuroscience 2021Quote: ... coupled to electrospray mass spectrometry (QTRAP 6500+, Sciex). For each analysis ...
-
bioRxiv - Microbiology 2022Quote: ... to perform hydrophilic interaction liquid chromatography analysis, the NEXERA XR UPLC system (Shimadzu, Columbia, MD, USA) coupled with the Triple TOF 6500 System (AB Sciex, Framingham, MA, USA) to perform reverse-phase liquid chromatography analysis ...
-
bioRxiv - Biochemistry 2021Quote: ... the free N-glycan were dissolved in methanol and 0.5 μL of methanol solution was applied onto a Opti-TOF™ 384-well plate (AB Sciex, Foster City, CA) together with 0.5 μL of CHCA matrix solution (4 mg/mL concentration in 70% acetonitrile ...
-
bioRxiv - Plant Biology 2024Quote: ... targeted MS/MS via multiple reaction monitoring (QTRAP6500) and untargeted via MS-TOF-SWATH-MS/MS (TripleToF 5600, both AB Sciex GmbH, Darmstadt, Germany) operating in negative or positive ion mode and controlled by Analyst 1.7.1 and 1.6 TF software (AB Sciex GmbH ...
-
bioRxiv - Microbiology 2022Quote: ... using liquid chromatography/mass spectrometry (LC/MS) on a Nexera-TripleTOF® 5600+ Target Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS) system (SCIEX, Foster City, California). Next ...
-
bioRxiv - Cell Biology 2023Quote: ... and L-citrulline/2H4-L-citrulline (L-Cit IS) RF-QQQ-MS detection using RapidFire-Triple Quadrupole-Mass Spectrometric analysis (RF-QQQ-MS) (Sciex 5000/5500 Mass Spectrometry). SPE/mobile phase A/B conditions were the same as those used in the BAO substrate turnover assay ...
-
bioRxiv - Plant Biology 2020Quote: ... The Mass Lynx 4.1 (Waters) and Peakview 2.2 (AB Sciex) softwares were used for data acquisition and processing ...
-
bioRxiv - Plant Biology 2021Quote: ... Mass Lynx version 4.1 (Waters) and Peakview version 2.2 (Sciex) software were used for acquisition and data processing ...
-
bioRxiv - Plant Biology 2021Quote: ... coupled with mass spectrometry system (SCIEX-6500Qtrap, AB SCIEX, USA). Minerals ...