Citations for Sciex :
1 - 50 of 69 citations for 6 Diazo 5 6 dihydro 5 oxo 1 naphthalenesulfonic acid since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
Rag GTPases and Phosphatidylinositol 3-Phosphate Mediate Recruitment of the AP-5/SPG11/SPG15 ComplexbioRxiv - Cell Biology 2020Quote: ... Dried peptides were suspended in 5% (v/v) formic acid and analysed in data-dependent acquisition (DDA) mode on a TripleTOF 5600 mass spectrometer (SCIEX) in-line with a nanoflow electrospray ion source and nano-HPLC system ...
-
bioRxiv - Physiology 2023Quote: Peptides obtained from each of the five NP mixtures were separately reconstituted according in a solution of 0.1% formic acid and 3% acetonitrile (34) spiked with 5 fmol μL PepCalMix from SCIEX (Framingham, MA, USA). Reconstitution volumes varied by NP types to allow for constant peptide quantity for MS injection between samples regardless of starting volume (240 ng ...
-
bioRxiv - Physiology 2023Quote: Peptides obtained from each of the five NP mixtures were separately reconstituted in a solution of 0.1% formic acid and 3% acetonitrile [37] spiked with 5 fmol μL PepCalMix from SCIEX (Framingham, MA, USA). Reconstitution volumes varied NPs to allow for constant peptide quantity for MS injection between samples regardless of starting volume (240 ng ...
-
bioRxiv - Microbiology 2019Quote: Dried extracts were re-dissolved in 5% acetonitrile (ACN) in water with 0.1% formic acid and analyzed using an Eksigent nanoLC® 400 system (AB Sciex, Foster City, CA, USA) with a HALO Phenyl-Hexyl column (0.5 × 50 mm ...
-
bioRxiv - Biochemistry 2022Quote: ... 5% BME buffer exchange solution (Sciex, MA, USA), using 10 kDA MWCO filters (Vivaproducts Inc. ...
-
bioRxiv - Animal Behavior and Cognition 2020Quote: ... The mass calibration was automatically performed every 6 injections using an APCI positive/negative calibration solution (AB SCIEX) via a calibration delivery system (CDS) ...
-
bioRxiv - Cell Biology 2021Quote: ... peptide mixtures were transferred onto a trap chip (with 200 μm x 6 mm ChromXP C18-CL chip, 3 μm, 300 Å, SCIEX) and washed at 2 μL/min for 10 min with the loading solvent (H2O/0.1% formic acid) ...
-
bioRxiv - Neuroscience 2022Quote: ... peptide mixtures were transferred onto a C18 pre-column chip (200 μm × 6 mm ChromXP C18-CL chip, 3 μm, 300 Å; SCIEX) and washed at 2 μL/min for 10 min with the loading solvent (H2O/0.1% formic acid ...
-
bioRxiv - Immunology 2019Quote: ... peptide mixtures were transferred onto a C18 pre-column chip (200 μm x 6 mm ChromXP C18-CL chip, 3 μm, 300 Å, SCIEX) and washed at 2 μl/min for 10 min with the loading solvent (H2O/0.1% formic acid ...
-
bioRxiv - Cell Biology 2019Quote: ... peptide mixtures were transferred onto a C18 pre-column chip (200 µm x 6 mm ChromXP C18-CL chip, 3 µm, 300 Å, SCIEX) and washed at 2 µl/min for 10 min with the loading solvent (H2O/0.1% formic acid ...
-
bioRxiv - Cancer Biology 2022Quote: ... Proteolytic peptides were loaded onto a C18 pre-column chip (200 μm × 6 mm ChromXP C18-CL chip, 3 μm, 300 Å; SCIEX) and washed at 2 μL/minute for 10 minutes with the loading solvent (H2O/0.1% FA ...
-
bioRxiv - Cancer Biology 2023Quote: ... Proteolytic peptides were loaded onto a C18 pre-column chip (200 μm × 6 mm ChromXP C18-CL chip, 3 μm, 300 Å; SCIEX) and washed at 2 μL/minute for 10 minutes with the loading solvent (0.1% FA in H2O ...
-
bioRxiv - Biochemistry 2021Quote: ... Polysulfoethyl SCX cartridge (5 micron, 300 Å bead) with cartridge holder was procured from Sciex, USA ...
-
bioRxiv - Microbiology 2022Quote: ... using a 5 μL injector loop on a Tempo LC MALDI Spotting system (ABI-MDS/Sciex). Separation was over a 50 min solvent gradient from 2% ACN and 0.1% TFA (v/v ...
-
bioRxiv - Biochemistry 2020Quote: ... that was externally calibrated using the Calmix 5 Opti-ToF High-Resolution TIS Calibration Insert (AB Sciex). The mMass - Open Source Mass Spectrometry Tool (Version 5.5.0 ...
-
bioRxiv - Biochemistry 2020Quote: ... that was calibrated externally using the Calmix 5 Opti-ToF High-Resolution TIS Calibration Insert (AB Sciex). N-glycan assignments were carried out using GlycoWorkbench software [32].
-
bioRxiv - Cancer Biology 2021Quote: ... The appropriate synthesis of 5-OP-RU was confirmed with LC-MS/MS (Triple Quad 5500, Sciex).
-
bioRxiv - Cancer Biology 2021Quote: ... Supernatants (5 μl) were injected and analyzed using a hybrid 6500 QTRAP triple quadrupole mass spectrometer (AB/SCIEX) coupled to a Prominence UFLC HPLC system (Shimadzu ...
-
bioRxiv - Pathology 2021Quote: ... 5-7 μL were injected and analyzed using a hybrid 6500 QTRAP triple quadrupole mass spectrometer (AB/SCIEX) coupled to a Prominence UFLC HPLC system (Shimadzu ...
-
bioRxiv - Cancer Biology 2023Quote: ... 5-7 μl were injected and analyzed using a hybrid 6500 QTRAP triple quadrupole mass spectrometer (AB/SCIEX) coupled to a Prominence UFLC HPLC system (Shimadzu ...
-
bioRxiv - Developmental Biology 2020Quote: ... Approximately 20μl of LC/MS grade water was used to resuspend samples and 5–10μl was injected into a LC-MS/MS system which was a SCIEX 5500 QTRAP mass spectrometer (SCIEX) coupled with an Agilent 1290 HPLC stack (Agilent Technologies) ...
-
bioRxiv - Physiology 2023Quote: ... About 4 μg of peptides were loaded on a trap column (ChromXP C18CL 5 µm 120 Å, Eksigent, SCIEX) and online desalting was performed with a flow rate of 10 µl per minute for 10 min ...
-
bioRxiv - Cancer Biology 2022Quote: ... For metabolite analysis samples were re-suspended in 20 µL HPLC grade water and 5-7 µl were injected and analyzed using a hybrid 6500 QTRAP triple quadrupole mass spectrometer (AB/SCIEX) coupled to a Prominence UFLC HPLC system (Shimadzu ...
-
bioRxiv - Cancer Biology 2022Quote: ... 5 µl from each sample were injected and analyzed using a 5500 QTRAP hybrid triple quadrupole mass spectrometer (AB/SCIEX) coupled to a Prominence UFLC HPLC system (Shimadzu ...
-
bioRxiv - Biochemistry 2023Quote: ... before being directly infused at a flow rate of 5 µL/min in to the QTRAP 6500 mass spectrometer (Sciex).
-
bioRxiv - Cancer Biology 2023Quote: The panel of amino acids was quantified based on aTRAQ kit for amino acid analysis (SCIEX, Framingham, MA, USA) and liquid chromatography coupled to a triple quadrupole tandem mass spectrometry technique ...
-
bioRxiv - Biochemistry 2020Quote: ... Samples were lyophilized and re-dissolved in 100 µL 1% formic acid before LC-MS/MS analysis (AB Sciex-API2000) and quantification (AB Sciex-MultiQuant) ...
-
bioRxiv - Biophysics 2020Quote: Molecular weight of the purified Sub16 pro was determined by spotting 1 μl of the purified sample with the matrix (sinapic acid) and analyzed on MALDI-TOF/TOF 5800 (AB Sciex) using linear mode ...
-
bioRxiv - Biophysics 2020Quote: ... resuspended in 100 mM HEPES pH 7.0 and 1 μl of the sample was spotted with matrix (sinapic acid) and analyzed on MALDI-TOF/TOF 5800 (AB Sciex) as described for the purified protein.
-
bioRxiv - Immunology 2021Quote: ... The reaction was terminated by adding ice-cold 0.1% trifluoroacetic acid (TFA) in H2O (100 μL) as described previously (56) and subjected to MALDI-MS analysis (AB Sciex 5800 TOF/TOF MS ...
-
bioRxiv - Biochemistry 2019Quote: iTRAQ labelled peptides were first fractionated by cation exchange (SCX) chromatography with SCX Cartridge (5 micron, 300 Å bead from AB Sciex, USA) using a step gradient of increasing concentration of ammonium formate (30 mM ...
-
bioRxiv - Biochemistry 2019Quote: ... with an ACQUITY UPLC-C18 column (20 mm × 180 μm; 5 μm) coupled to a TripleTOF 6600 mass spectrometer (Sciex, United States) as previously described.41 The Analyst TF® software (Sciex ...
-
bioRxiv - Biochemistry 2022Quote: ... labelled peptides were dissolved in ammonium formate buffer (5 mM, 2 ml) and loaded onto a pre-equilibrated SCX column ICAT™ cartridge kit (AB Sciex, USA). Peptides were eluted using different concentrations (30 ...
-
bioRxiv - Genetics 2024Quote: ... mode for AAs and ACs and in LC for methylmalonic acid (MMA) and lactic acid (LA) by using an API 4000 triple quadrupole mass spectrometer (Sciex, Toronto, Canada) coupled with an 1160 series Agilent high-performance liquid chromatography (HPLC ...
-
bioRxiv - Physiology 2019Quote: ... Quantitation of bile acids was carried out on MultiQuant software v3.0.2 (AB Sciex). BAs ...
-
bioRxiv - Cancer Biology 2020Quote: ... using the aTRAQ kit for amino acid analysis of physio-logical fluids (Sciex). Acquisition in the mass spectrometer was achieved by multiple reaction monitoring ...
-
bioRxiv - Cancer Biology 2021Quote: Desalted samples reconstituted in 0.1% formic acid were delivered into a QTRAP 6500 (Sciex) via a Dionex U3000 nano-LC system (Thermo ...
-
bioRxiv - Cell Biology 2022Quote: Bile acids were analyzed on an API-4000 triple quadrupole mass spectrometer (AB Sciex) coupled with a HPLC system (Agilent ...
-
bioRxiv - Cancer Biology 2019Quote: ... 0.1% formic acid) using an Eksigent NanoLC 400 System coupled to a TripleTOF® 6600 system (SCIEX). The DuoSpray Source was replumbed using 25 µm ID hybrid electrodes to minimize post-column dead volume ...
-
bioRxiv - Cancer Biology 2019Quote: ... 0.1% formic acid) using an Eksigent NanoLC 400 System coupled to a TripleTOF® 6600 system (SCIEX). The DuoSpray Source was replumbed using 25 µm ID hybrid electrodes to minimize post-column dead volume ...
-
The intestinal circadian clock drives microbial rhythmicity to maintain gastrointestinal homeostasisbioRxiv - Physiology 2022Quote: ... Targeted bile acid measurement was performed using a QTRAP 5500 triple quadrupole mass spectrometer (Sciex, Darmstadt, Germany) coupled to an ExionLC AD (Sciex ...
-
bioRxiv - Physiology 2022Quote: ... Targeted bile acid measurement was performed using a QTRAP 5500 triple quadrupole mass spectrometer (Sciex, Darmstadt, Germany) coupled to an ExionLC AD (Sciex ...
-
bioRxiv - Molecular Biology 2023Quote: ... Targeted bile acid measurement was performed using a QTRAP 5500 triple quadrupole mass spectrometer (Sciex, Darmstadt, Germany) coupled to an ExionLC AD (Sciex ...
-
bioRxiv - Cell Biology 2020Quote: ... 0.2% (v/v) formic acid in ultrapure H2O and separated using an LC-coupled TripleTOF 5600 + (AB Sciex). Peptides were separated on emitter-tip columns (75 µm ID fused silica tubing packed with C-18 material on a length of 12 cm) ...
-
bioRxiv - Cancer Biology 2021Quote: ... they were reconstituted in HPLC grade water containing 0.1% formic acid and 2% acetonitrile and analyzed on a TripleTOF 5600 mass spectrometer (SCIEX) operated in SWATH-MS mode ...
-
bioRxiv - Biophysics 2020Quote: Peak integration of iTRAQ-121 and iTRAQ-113 labeled amino acids were carried out by the Analyst 1.5.1 software (Applied Biosystems Sciex). The iTRAQ-113 labeled amino acids were used as the isotopic ISs for the normalization of their corresponding iTRAQ-121 labeled amino acids in biological samples ...
-
bioRxiv - Molecular Biology 2023Quote: ... the peptide mixtures were dissolved in 10 µl 0.1% formic acid (FA) and loaded on an Ekspert 425 nanoLC system (Sciex) equipped with a C18 column (Discovery BIO Wide Pore ...
-
Mammalian-unique eIF4E2 maintains GSK3β proline kinase activity to resist senescence against hypoxiabioRxiv - Cell Biology 2020Quote: ... The enriched phospho-peptides were then dissolved in 2% acetonitrile/0.1% formic acid and analyzed using TripleTOF 5600+ mass spectrometer coupled with the Eksigent nanoLC System (AB SCIEX, USA). The original MS/MS file data were submitted to ProteinPilot Software v4.5 for data analysis ...
-
bioRxiv - Cancer Biology 2021Quote: ... derivatization in the presence of internal standards followed by FIA-MS/MS (acylcarnitines, (lyso-) phosphatidylcholines, sphingomyelins, hexoses) and LC-MS/MS (amino acids, biogenic amines) using a SCIEX 4000 QTRAP (SCIEX) or Waters Xevo TQ-S (Waters ...
-
bioRxiv - Microbiology 2020Quote: ... The peptide samples were dissolved in 2% acetonitrile/0.1% formic acid and analyzed using a TripleTOF 5600+ mass spectrometer coupled with the Eksigent nanoLC System (SCIEX, USA). Peptide was loaded onto a C18 trap column (5 μm ...