Labshake search
Citations for Sciex :
51 - 100 of 110 citations for 6 propan 2 yl 1 3 5 triazine 2 4 diamine since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
Borrelia PeptideAtlas: A proteome resource of common Borrelia burgdorferi isolates for Lyme researchbioRxiv - Biochemistry 2023Quote: ... Peptides were separated on analytical column (75 μm × 20 cm, ChromXP C18-CL 3 μm, 120 Å, Eksigent, Sciex) with the gradient of buffer B (95% acetonitrile in 0.1% formic acid ...
-
bioRxiv - Neuroscience 2023Quote: ... peptides were transferred to the 75 µm x 15 cm ChromXP C18-CL chip (3 µm, 120 Å; SCIEX), and eluted at a flow rate of 300 nL/min with a 3 h gradient using aqueous and acetonitrile solvent buffers.
-
bioRxiv - Biochemistry 2021Quote: ... Polysulfoethyl SCX cartridge (5 micron, 300 Å bead) with cartridge holder was procured from Sciex, USA ...
-
bioRxiv - Microbiology 2023Quote: ... Cleaved peptides were then labelled with iTRAQ reagents (4-Plex system) according to the manufacturer’s instructions (Sciex). iTRAQ labeling regents were dissolved in ethanol ...
-
bioRxiv - Cell Biology 2020Quote: ... The trapped tryptic peptide extracts were then washed onto the analytical 75 μm x 150 mm ChromXP C18 CL 3 μm column (SCIEX) at 400 nl/min and a column temperature of 45 °C ...
-
bioRxiv - Biochemistry 2020Quote: ... peptide mixtures were loaded onto a C18 pre-column chip (200 μm x 0.4 mm ChromXP C18-CL chip, 3 μm, 120 Å, SCIEX) and washed at 2 μl/min for 10 min with the loading solvent (H2O/0.1% formic acid ...
-
bioRxiv - Neuroscience 2019Quote: ... samples were subjected to trap-elution through loading onto a trap column (Eksigent nanoLC trap, #5016752; ChromXP C18, 3 µm 120 Å, 350 µm x 0.5 mm [SCIEX]) at 2 µl/min for 10 min in loading buffer (2 % (v/v ...
-
bioRxiv - Biochemistry 2020Quote: ... After loading 8 μL of each sample at 3 μL/min on an Eksigent 425 2D HPLC system (AB SCIEX), the peptides were eluted onto an in-housed packed analytical C18 column (internal diameter ...
-
bioRxiv - Biochemistry 2022Quote: ... peptide mixtures were loaded onto a C18 pre-column chip (200 µm x 0.4 mm ChromXP C18-CL chip, 3 µm, 120 Å, SCIEX) and washed at 2 µl/min for 10 min with the loading solvent (H2O/0.1% formic acid ...
-
bioRxiv - Microbiology 2022Quote: ... peptide mixtures were loaded onto a C18 pre-column chip (200 μm x 0.4 mm ChromXP C18-CL chip, 3 μm, 120 Å, SCIEX) and washed at 2 μl/min for 10 min with the loading solvent (H2O/0.1% formic acid ...
-
bioRxiv - Molecular Biology 2022Quote: ... peptide mixtures were loaded onto a C18 pre-column chip (200 µm x 0.4 mm ChromXP C18-CL chip, 3 µm, 120 Å, SCIEX) and washed at 1-2 µl/min for 10 min with the loading solvent (H2O/0.1% formic acid ...
-
bioRxiv - Neuroscience 2021Quote: ... peptide mixtures were loaded onto a C18 pre-column chip (200 µm x 0.4 mm ChromXP C18-CL chip, 3 µm, 120 Å, SCIEX) and washed at 2 µl/min for 10 min with the loading solvent (H2O/0.1% formic acid ...
-
bioRxiv - Microbiology 2021Quote: ... Twelve microliters of each sample were injected onto a ChromXP C18CL column (3 µm, 120 Å, 150 mm x 0.3 mm, Sciex). Gradient elution was performed with mobile phase A (0.1% formic acid in water ...
-
bioRxiv - Neuroscience 2023Quote: ... peptide mixtures were loaded onto a C18 pre-column chip (200 µm x 0.4 mm ChromXP C18-CL chip, 3 µm, 120 Å, SCIEX) and washed at 2 µl/min for 10 min with the loading solvent (H2O/0.1% formic acid ...
-
Borrelia PeptideAtlas: A proteome resource of common Borrelia burgdorferi isolates for Lyme researchbioRxiv - Biochemistry 2023Quote: ... Peptides from the 2 isolates were run separately by loading on trap column (200 μm × 0.5 mm, Chrom XP C18-CL 3 μm, 120 Å, Eksigent, AB Sciex). Peptides were separated on analytical column (75 μm × 20 cm ...
-
bioRxiv - Microbiology 2023Quote: ... and subjected to LC−MS/MS experiments using Sciex 5600+ Triple-TOF mass spectrometer coupled with ChromXP reversed-phase 3[μm C18-CL trap column (350[μm[×[0.5[mm, 120[Å, Eksigent, AB Sciex) and nanoViper C18 separation column (75[μm[×[250[mm ...
-
bioRxiv - Neuroscience 2023Quote: ... peptide mixtures were loaded onto a C18 pre-column chip (200 µm x 0.4 mm ChromXP C18-CL chip, 3 µm, 120 Å, SCIEX) and washed at 2 µl/min for 10 min with the loading solvent (H2O/0.1% formic acid ...
-
bioRxiv - Microbiology 2022Quote: ... using a 5 μL injector loop on a Tempo LC MALDI Spotting system (ABI-MDS/Sciex). Separation was over a 50 min solvent gradient from 2% ACN and 0.1% TFA (v/v ...
-
bioRxiv - Neuroscience 2019Quote: ... followed by separation at 300 nl/min across an analytical column (Eksigent nano LC column, #805-0012; ChromXP C18, 3 µm 120 Å, 75 µm x 15 cm [SCIEX]) equilibrated in 98 % buffer A (0.1 % (v/v ...
-
bioRxiv - Microbiology 2020Quote: ... The trapped tryptic peptide extracts were then washed onto the analytical 75 μm x 150 mm ChromXP C18 CL 3 μm column (SCIEX, Canada) at 400 nL/min and a column temperature of 45°C ...
-
bioRxiv - Microbiology 2021Quote: LC−MS/MS experiments were performed using Sciex 5600+ Triple-TOF mass spectrometer coupled with ChromXP reversed-phase 3 μm C18-CL trap column (350μm × 0.5 mm, 120 Å, Eksigent, AB Sciex, Massachusetts, USA) and nanoViper C18 separation column (75 μm × 250mm ...
-
bioRxiv - Biochemistry 2020Quote: ... that was externally calibrated using the Calmix 5 Opti-ToF High-Resolution TIS Calibration Insert (AB Sciex). The mMass - Open Source Mass Spectrometry Tool (Version 5.5.0 ...
-
bioRxiv - Biochemistry 2020Quote: ... that was calibrated externally using the Calmix 5 Opti-ToF High-Resolution TIS Calibration Insert (AB Sciex). N-glycan assignments were carried out using GlycoWorkbench software [32].
-
bioRxiv - Cancer Biology 2021Quote: ... The appropriate synthesis of 5-OP-RU was confirmed with LC-MS/MS (Triple Quad 5500, Sciex).
-
bioRxiv - Systems Biology 2020Quote: ... and injected into an online LC-MS/MS workflow (500 nL/min) using a 3 h gradient run using a Sciex TripleTOF 5600 instrument (Sciex; Framingham, MA). Raw spectra files were converted into Mascot Generic File format (MGF ...
-
bioRxiv - Physiology 2020Quote: ... of each sample were loaded onto a ChromXP C18 peptide trap (15 cm x 200 μm, 3 μm particle size, 120 Å, SCIEX, USA). The peptides were separated with a 60 min gradient of 5 – 40% acetonitrile ...
-
bioRxiv - Plant Biology 2021Quote: ... approximately 4 µg) were eluted from a cHiPLC C18 column (15 cm × 200 μm, 3 μm, ChromXP C18CL, 120 Å, 25°C, Sciex, USA) using a linear gradient of 2-35% of solvent B (90% acetonitrile with 0.1% formic acid ...
-
bioRxiv - Microbiology 2022Quote: ... It was coupled with a chromXP reversed-phase 3-µm C18-CL trap column (350 μm by 0.5 mm, 120 Å; Eksigent; AB Sciex, MA, USA) and a nanoViper C18 separation column (75 μm by 250 mm ...
-
bioRxiv - Cancer Biology 2021Quote: ... Supernatants (5 μl) were injected and analyzed using a hybrid 6500 QTRAP triple quadrupole mass spectrometer (AB/SCIEX) coupled to a Prominence UFLC HPLC system (Shimadzu ...
-
bioRxiv - Pathology 2021Quote: ... 5-7 μL were injected and analyzed using a hybrid 6500 QTRAP triple quadrupole mass spectrometer (AB/SCIEX) coupled to a Prominence UFLC HPLC system (Shimadzu ...
-
bioRxiv - Cancer Biology 2023Quote: ... 5-7 μl were injected and analyzed using a hybrid 6500 QTRAP triple quadrupole mass spectrometer (AB/SCIEX) coupled to a Prominence UFLC HPLC system (Shimadzu ...
-
bioRxiv - Biochemistry 2020Quote: ... A total of 100 μg of each sample was trypsin-digested overnight and labeled using 4-plex iTRAQ reagents (AB SCIEX) as manual described ...
-
Molecular Basis of Sex Difference in Neuroprotection induced by Hypoxia Preconditioning in ZebrafishbioRxiv - Neuroscience 2020Quote: Prior to trypsin digestion all the protein samples were gone through reduction and cysteine blocking using the reagents provided with iTRAQ 4-plex kit (AB SCIEX). Digestion and labelling of proteins were done according to manufacturer’s protocol ...
-
bioRxiv - Neuroscience 2021Quote: ... The resultant peptides were further labeled using isobaric tags for relative and absolute quantification (iTRAQ) 4-plex commercial reagent kit (AB Sciex) according to the manufacturer’s instructions ...
-
bioRxiv - Biochemistry 2020Quote: ... and analytical 75 μm x 150 Atlantis DB C18, 3 μm, 300 Å columns (Water, Milford, MA) interfaced with 6600 TripleTOF (Sciex, Framingham, MA). A 3 min trapping step using 2% ACN ...
-
bioRxiv - Developmental Biology 2020Quote: ... Approximately 20μl of LC/MS grade water was used to resuspend samples and 5–10μl was injected into a LC-MS/MS system which was a SCIEX 5500 QTRAP mass spectrometer (SCIEX) coupled with an Agilent 1290 HPLC stack (Agilent Technologies) ...
-
bioRxiv - Cancer Biology 2022Quote: ... For metabolite analysis samples were re-suspended in 20 µL HPLC grade water and 5-7 µl were injected and analyzed using a hybrid 6500 QTRAP triple quadrupole mass spectrometer (AB/SCIEX) coupled to a Prominence UFLC HPLC system (Shimadzu ...
-
Rag GTPases and Phosphatidylinositol 3-Phosphate Mediate Recruitment of the AP-5/SPG11/SPG15 ComplexbioRxiv - Cell Biology 2020Quote: ... Dried peptides were suspended in 5% (v/v) formic acid and analysed in data-dependent acquisition (DDA) mode on a TripleTOF 5600 mass spectrometer (SCIEX) in-line with a nanoflow electrospray ion source and nano-HPLC system ...
-
bioRxiv - Cancer Biology 2022Quote: ... 5 µl from each sample were injected and analyzed using a 5500 QTRAP hybrid triple quadrupole mass spectrometer (AB/SCIEX) coupled to a Prominence UFLC HPLC system (Shimadzu ...
-
bioRxiv - Biochemistry 2023Quote: ... before being directly infused at a flow rate of 5 µL/min in to the QTRAP 6500 mass spectrometer (Sciex).
-
bioRxiv - Cell Biology 2019Quote: ... Duplicate aliquots of axonemes (50-60 μg each) from each strain were reacted with 4-plex iTRAQ reagents (114-117, AB Sciex, Foster City, CA) to obtain two technical replicates per biological sample ...
-
bioRxiv - Cell Biology 2023Quote: ... Duplicate aliquots of axonemes (50-60 μg each) from each strain were reacted with 4-plex iTRAQ reagents (114-117, AB Sciex, Foster City, CA) to obtain two technical replicates per biological sample ...
-
bioRxiv - Microbiology 2022Quote: ... Animal plasma and tissue concentrations of 4’FlU and 4’-FlU-TP were measured by a qualified LC/MS/MS method in MRM mode on a QTRAP 5500 (Sciex, Santa Clara, CA, USA) instrument.
-
bioRxiv - Biochemistry 2019Quote: iTRAQ labelled peptides were first fractionated by cation exchange (SCX) chromatography with SCX Cartridge (5 micron, 300 Å bead from AB Sciex, USA) using a step gradient of increasing concentration of ammonium formate (30 mM ...
-
bioRxiv - Biochemistry 2019Quote: ... with an ACQUITY UPLC-C18 column (20 mm × 180 μm; 5 μm) coupled to a TripleTOF 6600 mass spectrometer (Sciex, United States) as previously described.41 The Analyst TF® software (Sciex ...
-
bioRxiv - Microbiology 2019Quote: Dried extracts were re-dissolved in 5% acetonitrile (ACN) in water with 0.1% formic acid and analyzed using an Eksigent nanoLC® 400 system (AB Sciex, Foster City, CA, USA) with a HALO Phenyl-Hexyl column (0.5 × 50 mm ...
-
bioRxiv - Molecular Biology 2023Quote: ... using a micro electrode (1–10 µL/min; SCIEX). The solvent system consisted of 0.1% FA in water (solvent A ...
-
bioRxiv - Pathology 2020Quote: ... The compound dependent parameters for each MRM transition of analytes are given in Supplement Table.1 and the data was collected using the Analyst 1.6.2 Software (AB Sciex).
-
bioRxiv - Physiology 2024Quote: ... and quantitative analysis of the data was carried out by least squares regression of the peak area ratio of the steroid to the corresponding internal standard with equal or 1/x weighting using MultiQuant software v3.0.3 (AB Sciex).
-
bioRxiv - Molecular Biology 2022Quote: ... Data quality was ensured by: 1) tuning the DMS compensation voltages using a set of lipid standards (SCIEX, 5040141) after each cleaning ...