bioRxiv - Cell Biology 2022Quote: ... A 3 µl volume of the Kif5B suspension was first deposited at the surface of a glow-discharged holey carbon grid (Quantifoil R2/2, Cu200) in the temperature (23 °C ...
-
bioRxiv - Microbiology 2023Quote: ... Both TBEV strain Neudoerfl and Hypr samples were vitrified in liquid ethane on holey carbon coated copper grids (Quantifoil 2/1, mesh 300, Quantifoil Micro Tools GmbH) using Vitrobot Mark IV (Thermo Fisher) ...
-
bioRxiv - Biochemistry 2023Quote: ... 3µL of sample were frozen in liquid ethane on 2/1 Quantifoil Multi A holey carbon supported grids (Quantifoil, Multi A, 400 mesh) using Vitrobot Mark IV (FEI Company) ...
-
bioRxiv - Biophysics 2023Quote: Three microliters of the purified GLV-HP or GLV-CAT sample was placed on a glow-discharged holey carbon grid (Quantifoil R2/2 or R2/1, Cu 300 mesh; Quantifoil Micro Tools GmbH) for 3 s blotting time at 4°C ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: Grids were prepared by applying 3.5 μLs of the Z7757 complex or 2 μLs of the Lisuride complex to glow discharged UltrAuFoil holey gold grids (Quantifoil, Au300-R1.2/1.3). The girds containing Z7757 were then vitrified by plunge freezing into a 60/40 mixure of liquid ethane/propane using a Vitrobot mark IV (FEI ...
-
bioRxiv - Cell Biology 2020Quote: 4 µl of the cultured yeast cells (OD600 of 0.4) were added to a glow-discharged (30 seconds at -30 mA) copper R2/2 holey carbon grid (Quantifoil Micro Tools GmbH, Jena, Germany), then the grid was rapidly plunge frozen in liquid ethane using a homemade plunge freezer and stored in liquid nitrogen until used ...
-
bioRxiv - Biophysics 2022Quote: ... an aliquot of 3 μL of sample was applied onto a glow-discharged holey carbon-coated copper grid (300 mesh, QUANTIFOIL® R 2/1) or holey gold grid (300 mesh ...
-
bioRxiv - Cell Biology 2022Quote: ... 4 µL of the mixture were pipetted onto a copper EM grid with holey carbon film (R2/2, 200 mesh, Quantifoil Micro Tools GmbH, Q43486) that had been freshly glow-discharged for 30 s at -30 mAmp ...
-
bioRxiv - Biochemistry 2022Quote: ... Samples were prepared by depositing 3 μl of the crystalline slurry onto a glow-discharged EM grid (Quantifoil, Cu 200 mesh, R2/2 holey carbon). Excess liquid was blotted away and the sample was vitrified using a Leica GP2 vitrification robot ...
-
bioRxiv - Molecular Biology 2022Quote: 3 μL of ~120 nM mitoribosome was applied onto a glow-discharged (20 mA for 30 sec) holey-carbon grid (Quantifoil R2/2, copper, mesh 300) coated with continuous carbon (of ~3 nm thickness ...
-
bioRxiv - Cell Biology 2019Quote: ... 4 µl of the solution was applied to a glow-discharged (30 s at −35 mA) copper R2/2 holey carbon grid (Quantifoil Micro Tools GmbH, Jena, Germany). After removing excess liquid by blotting the grid from the back side with Whatman filter paper No ...
-
bioRxiv - Microbiology 2019Quote: ... Four μl of this mixture was applied onto freshly glow-discharged copper R2/2 of th0 Quantifoil holey carbon grids (Quantifoil Micro Tools GmbH, Jena, Germany). Using an FEI Vitrobot Mark IV ...
-
bioRxiv - Biophysics 2020Quote: ... 2 μL of a 1 in 6 dilution of the batch crystallisation was applied to the carbon side of glow discharged R2/2 Quantifoil™ grids (Quantifoil Micro Tools, Jena, Germany). Excess liquid was removed by blotting for 4-6 s with a Vitrobot (Thermo Fisher ...
-
bioRxiv - Microbiology 2020Quote: ... 3.5 μl of that mixture was transferred to a 3 mm freshly glow-discharged Quantifoil R2/2 Cu 300 mesh holey carbon grid (Quantifoil Micro Tools GmbH, Jena, Germany). Excess liquid was blotted away using a Leica EM GP plunge-freezer at room temperature and 80% humidity (blot time 2-3 sec ...
-
bioRxiv - Molecular Biology 2022Quote: ... The pellet was then resuspended in warm EM buffer and 3 μL of this sample was applied to a carbon on gold grid (Quantifoil R2/2 Au 200 mesh), recently glow-discharged for 1 min at 30 mA ...
-
bioRxiv - Biochemistry 2022Quote: ... The endogenous samples were applied onto grids containing an additional thin layer of continuous carbon support (Quantifoil R1.2/1.3 Cu 200 mesh + 2 nm C) and incubated for 30 sec before blotting and freezing ...
-
bioRxiv - Biochemistry 2023Quote: 3 μL of ∼120 nM mitoribosome was applied onto a glow-discharged (20 mA for 30 sec) holey- carbon grid (Quantifoil R2/2, copper, mesh 300) coated with continuous carbon (of ∼3 nm thickness ...
-
bioRxiv - Biophysics 2023Quote: ... 4 μl of the extracellular parasites were pipetted onto a glow-discharged (30 seconds at −30 mA) copper R2/2 holey carbon grid (Quantifoil Micro Tools GmbH, Jena, Germany). Samples were back-blotted with a Whatman filter paper (grade 1 ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... a volume of 6-8 μL of each sample was applied onto a gold grid covered by a holey gold film (UltrAuFoil 2/1, Quantifoil Micro Tools GmbH, Jena, Germany). Excess of liquid was blotted automatically between two strips of filter paper or only from the backside of the Grid ...
-
bioRxiv - Biochemistry 2023Quote: ... 3 μL of ∼120 nM mitoribosome was applied onto a glow-discharged (20 mA for 30 sec) holey-carbon grid (Quantifoil R2/2, copper, mesh 300) coated with continuous carbon (of ∼3 nm thickness ...
-
bioRxiv - Neuroscience 2024Quote: ... Supernatant after centrifugation mixed with 10-nm gold beads solution (Aurion, cat # 25486) at 1:1 ratio was added to the mounted grid (Quantifoil R2/2 Cu 200 EM). No other chemicals or stimulation were applied prior to plunge freezing ...
-
bioRxiv - Biophysics 2020Quote: ... 2.5 ul of second-generation Aβ40 fibrils at a concentration of 0.43 mg/ml (100 μM) was applied to a glow-discharged holey carbon grid (Quantifoil R1.2/1.3, 300 mesh gold) for 60 s ...
-
bioRxiv - Biophysics 2019Quote: ... Approximately 5 µL of sample (diluted if necessary) was placed on a copper grid (Quantifoil® S7/2 Cu 400 mesh, holey carbon films, Quantifoil Micro Tools GmbH, Jena, Germany) and any excess liquid was absorbed by a filter paper ...
-
bioRxiv - Biochemistry 2022Quote: The samples were frozen on copper or gold grids with holey carbon film coated with a 2 nm continuous carbon film (Quantifoil R1.2/1.3 ultrathin carbon, 300 mesh) freshly glow discharged for 20 s at 15 mA (PELCO easiGlow) ...
-
bioRxiv - Biochemistry 2023Quote: ... A sample of 3.0 μM of FH2 and 10.6 μM of actin monomers was applied to holey grids without a carbon film (Quantifoil Au 2/1 300 mesh from EMS). After diluting 4-fold ...
-
bioRxiv - Neuroscience 2023Quote: ... 3.5 μL of CopiaGag capsid protein sample was applied to a 300-mesh copper grid with continuous 2 nm carbon film (Electron Microscopy Sciences, QUANTIFOIL® C2-C15nCu30-50) at 10 °C with 90% humidity in a Vitrobot Mark IV (FEI) ...
-
bioRxiv - Biochemistry 2023Quote: ... A 3 µL drop was applied to a glow-discharged (PELCO easiGlow, 15 mA, 2 min) holey carbon grid (Quantifoil R1.2/1.3 on gold 200 mesh support), blotted for 3-4 seconds with Whatman Grade 595 filter paper (GE Healthcare) ...
-
bioRxiv - Biochemistry 2022Quote: Freshly prepared ribosome–Sec61–KZR-8445 complex at 300–500 nM concentration was applied on glow discharged holey-carbon grids (Quantifoil, R1.2/1.3 with a 2-nm carbon film) and flash frozen with an automated plunge freezer (Leica microsystems) ...
-
bioRxiv - Immunology 2020Quote: ... four-microliter aliquots of Fcα-J-SC (0.3 mg/ml) or Fcα-J-SC-SpsANTD (0.2 mg/ml) were applied to glow-discharged holy-carbon gold grids (Quantifoil, R1.2/1.3), blotted with filter paper at 4 °C and 100% humidity ...
-
bioRxiv - Biophysics 2019Quote: 3 µL of purified aldolase (1.6 mg/mL) or apoferritin (5 mg/mL) was dispensed on UltrAuFoil R1.2/1.3 300-mesh grids (Quantifoil Micro Tools GmbH) that had been freshly plasma cleaned for six seconds at 15Watts (75% nitrogen/25% oxygen atmosphere ...
-
bioRxiv - Biochemistry 2022Quote: ... 2.5 μL of the purified PTH-PTH1R-Gs and PTHrP-PTH1R-Gs complexes at a concentration of ∼8.4 mg/mL and ∼5.1 mg/mL were respectively applied to the glow-discharged Au 300 mesh holey carbon grids (Quantifoil R1.2/1.3). The grids were blotted and then plunge-frozen in liquid ethane using a Vitrobot Mark IV (ThermoFisher Scientific ...
-
bioRxiv - Molecular Biology 2023Quote: ... Aliquots of 3 μL of samples at 0.75 mg/ml or 1.5 mg/ml protein concentration were placed on 300-mesh Cu holey carbon grids (Quantifoil, R1.2/1.3) after glow-discharge (PELCO easiGlow™ ...
-
bioRxiv - Molecular Biology 2023Quote: ... 4 µl of MHAS2168-Mb_H2 complex (9.4 mg/ml and 6 mg/ml) were applied to glow-discharged (45 s) holey carbon grids (Quantifoil R1.2/1.3 Au 200 mesh) and a Grid Plunger GP2 (Leica ...
-
bioRxiv - Biochemistry 2024Quote: A volume of 3 µl purified protein complex at a concentration of 1mg/ml (JSR1-hGi) or 8 mg/ml (JSR1-jsGiq) was applied to glow-discharged holey carbon grids (Quantifoil R1.2/1.3 Cu 200 mesh). The grids were blotted with a Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Biochemistry 2021Quote: ... or 0.3 mg/ml for Au-foil grids (Quantifoil, Jena, DE). 4ul of sample was applied to glow-discharged grids ...
-
bioRxiv - Molecular Biology 2020Quote: ... at 13 °C and 100% humidity: 3 μl of sample were applied onto a freshly glow-discharged copper R2/1 300 mesh grid (Quantifoil), blotted for 8 s on both sides with blotting force −20 and plunge-frozen in liquid ethane.
-
bioRxiv - Biochemistry 2023Quote: 3 μl of 50 μM purified insulin in 20 mM sodium phosphate buffer containing (pH 7.5) containing 100 mM NaCl was applied onto a grow discharged Quantifoil R1.2/1.3 Cu 200 grid (Quantifoil Micro Tool GmbH) and subsequently blotted by filter papers and plunged into liquid ethane for the vitrification using a Vitrobot Mark IV (Thermo Fisher Scientific) ...
-
bioRxiv - Pathology 2023Quote: ... bombycis spores (1×105 spores/mL) were placed on nickel grids (Quantifoil, Beijing, China) for 15 min and germinated in 0.1 M KOH for 30 min at 30°C ...
-
bioRxiv - Biophysics 2023Quote: 2.5μL of ∼1.2 mg/ml sample were applied to UltraAuFoil 1.2/1.3 300 mesh (Quantifoil) or 1.2/1.3 Cu 300-mesh grids (Quantifoil ...
-
bioRxiv - Biophysics 2019Quote: ... A 3 μl aliquot of ribosomes at a concentration of 100 nM was placed on plasma-cleaned UltrAuFoil® grids (Quantifoil, R1.2/1.3) and vitrified using Vitrobot Mark IV (FEI company) ...
-
bioRxiv - Cell Biology 2020Quote: ... 3.5 μL of the peak fraction from a BBSome purification (0.4 - 0.6 mg/mL) was applied to glow-discharged R1.2/1.3 holey carbon copper grids (Quantifoil) covered with a thin homemade carbon film ...
-
bioRxiv - Biochemistry 2021Quote: 2.5 μl of ACE2-RBD-62 complex at 3.5 mg/ml concentration was transferred to glow discharged UltrAuFoil R 1.2/1.3 300 mesh grids (Quantifoil), blotted for 2.5 seconds at 4°C ...
-
bioRxiv - Biophysics 2020Quote: 3 ml of apoferritin at 3.8 mg/ml were applied to freshly glow discharged R 1.2/1.3 holey carbon grids (Quantifoil) at 4°C and 100% relative humidity followed by plunge-freezing in liquid ethane using a Vitrobot Mark IV (Thermo Fisher Scientific) ...
-
bioRxiv - Biochemistry 2022Quote: ... proper dilutions were made to a final concentration of ∼.7 mg/mL and a 3.0 µL drop was applied to glow discharged holey carbon (R 1.2/1.3; Quantifoil), then blotted for 3 s ...
-
bioRxiv - Cell Biology 2021Quote: ... 3μL sample (TRAPPII at 6.8mg/ml and TRAPPII-Rab11/Ypt32 at 5.5mg/ml) was applied to a plasma cleaned UltrAuFoil R1.2/1.3 (Quantifoil) grid inside a Vitrobot IV (Thermo Fisher Scientific ...
-
bioRxiv - Biochemistry 2022Quote: ... 3.5 µL of purified FERRY complex at a concentration of 0.7 mg/mL was applied to freshly glow-discharged UltrAuFoil 1.2/1.3 grids (Quantifoil), automatically blotted for 3 s and plunged into liquid ethane using the a Vitrobot (Thermo Fisher Scientific) ...
-
bioRxiv - Microbiology 2022Quote: 3 μl of 529-nt nanorods (1.01 x 1015 particles/ml) were applied to glow-discharged R1.2/1.3 Cu 300 mesh grids (Quantifoil) and frozen on a Mark IV Vitrobot (Thermo Fisher Scientific ...
-
bioRxiv - Biophysics 2023Quote: 3 μl purified MRS2 at approximately 0.5 mg/ml was applied to a glow-discharged 400-mesh R 1.2/1.3 Cu grid (Quantifoil). The cryo grids were blotted for 6 s at 4°C and 95% ...
-
bioRxiv - Biophysics 2023Quote: We applied 3 μl of purified MeFDH1 (0.5 mg/ml) to a 1.2/1.3 holey carbon 200 mesh grid (Quantifoil), blotted for 4 s in a 100% humidity environment at 12 °C and then froze the specimens by plunging them into liquid ethane using a Vitrobot Mark IV (FEI).
-
bioRxiv - Molecular Biology 2022Quote: Purified SARS-CoV-2 spike samples in 10mM Hepes pH7.2 and 150mM NaCl (3 μL at 0.62-0.75mg/ml) were kept at 4C until their application onto QUANTIFOIL R 1.2/1.3 Cu:300-mesh grids (QUANTIFOIL). The grids were vitrified using a Leica GP automatic vitrification robot (Leica) ...