Labshake search
Citations for Quantifoil Micro Tools :
1 - 50 of 115 citations for Tetratricopeptide Repeat Protein 5 TTC5 Antibody since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biochemistry 2021Quote: ... 3.5 μl of the freshly purified sample from the peak fraction in DDM at ~2.0 mg/ml for the B.1.1.7 protein or ~1.5 mg/ml for the B.1.351 protein was applied to a 1.2/1.3 Quantifoil grid (Quantifoil Micro Tools GmbH), which had been glow discharged with a PELCO easiGlow™ Glow Discharge Cleaning system (Ted Pella ...
-
bioRxiv - Biophysics 2023Quote: 3.5 µL of protein or lipid solution was applied onto a freshly glow-discharged carbon-coated copper mesh grid (Quantifoil). After 1 min ...
-
bioRxiv - Biochemistry 2021Quote: ... 3 μL of protein solution at 5 mg/mL (with 0.025% DDM) was applied onto a glow-discharged holey carbon grid (Quantifoil, 300 mesh, R1.2/1.3). Excess samples were blotted for 5.0 s with a blotting force of 3 ...
-
bioRxiv - Biophysics 2021Quote: ... 2.5 μL of each purified CCKAR–G protein complex was applied individually onto the glow-discharged holey carbon grids (Quantifoil, Au300 R1.2/1.3) in a Vitrobot chamber (FEI Vitrobot Mark IV) ...
-
bioRxiv - Biochemistry 2024Quote: ... 3.5 μL of this protein-DNA mix were applied to 300-mesh copper R2/1 Quantifoil Holey Carbon Grids (Quantifoil Micro Tools GmbH) that had been freshly glow discharged for 30 seconds at 25 mA in a GloQube Glow Discharge System (Quorum Technologies ...
-
bioRxiv - Molecular Biology 2023Quote: Freshly purified ZorAB sample was concentrated to 2-3 mg/mL and 2.7 μL protein was applied onto the glow-discharged (30 s, 5 mA) grids (Quantifoil R0.6/1 300 mesh Au) and plunge-frozen into liquid ethane using a Vitrobot Mark IV (FEI ...
-
bioRxiv - Molecular Biology 2022Quote: ... An aliquot of 4 μL protein sample of Spike protein was applied onto a glow-discharged 300 mesh grid (Quantifoil Au R1.2/1.3) and GraFuture™-RGO grid which was supported with a thin layer of RGO (reduced graphene oxide) ...
-
bioRxiv - Biophysics 2020Quote: ... The protein was spotted onto UltraAuFoil 1.2/1.3 gold grids (Quantifoil) plasma cleaned using an Ar/O2 gas mix ...
-
bioRxiv - Bioengineering 2019Quote: ... 5 μl of the sample was placed on a carbon coated grid (Quantifoil, D) previously glow-discharged for 30 seconds (Emitech K100X ...
-
bioRxiv - Biophysics 2020Quote: ... Protein was frozen on R 1.2/1.3 grids with 300 Au mesh (Quantifoil, Germany). This dataset was collected at UCSF on the Titan Krios 2 ...
-
bioRxiv - Biophysics 2020Quote: The purified N protein was prepared on UltraAuFoil R1.2/1.3 gold support grids (Quantifoil). 3 µl of sample was applied to glow-discharged grids ...
-
bioRxiv - Biophysics 2023Quote: ... by applying protein to glow-discharged QuantiFoil Au R1.2/1.3 200-mesh grids (Quantifoil), blotting for 3.0 s under 100% humidity at 4°C ...
-
bioRxiv - Biophysics 2019Quote: ... Approximately 5 µL of sample (diluted if necessary) was placed on a copper grid (Quantifoil® S7/2 Cu 400 mesh ...
-
bioRxiv - Immunology 2021Quote: The purified and cross-linked recombinant NLRP3 protein was loaded onto glow-discharged EM-grids (Quantifoil, R2/1 Cu-covered with homemade ultrathin carbon support film) ...
-
bioRxiv - Biophysics 2020Quote: ... The protein was then blotted onto Cu 300 mesh Quantifoil 1.2/1.3 grids (Quantifoil Micro Tools) two times with 3.5 μl sample each time ...
-
bioRxiv - Plant Biology 2023Quote: ... 3 μl protein was applied to glow-discharged carbon grids (Quantifoil Cu R1.2/1.3 300 mesh). Subsequently ...
-
bioRxiv - Microbiology 2021Quote: ... and 5 μl of the washed cells were introduced to Au grids (R2/1, 200 mesh; Quantifoil). The grids were fixed in 4% PFA (in TBS ...
-
bioRxiv - Immunology 2021Quote: ... by shaking at 1200 rpm for 5 minutes at 37°C using a plate shaker (Quantifoil Instruments) after stimulating with collagen at a range of concentrations ...
-
bioRxiv - Cell Biology 2022Quote: Vero-E6 were seeded on holey carbon film R 5/20 gold 200 mesh EM grids (Quantifoil Micro Tools GmbH ...
-
bioRxiv - Microbiology 2022Quote: ... 2.7 μl of freshly purified sample was applied onto glow-discharged (30 s, 5 mA) grids (Quantifoil R 0.6/1 300 mesh Cu or Ultrafoil 0.6/1 300 mesh Au ...
-
bioRxiv - Biochemistry 2023Quote: 3.5 μL of LRRK2RCKW:E11 complex was applied to glow-discharged UltraFoil 300 mesh R1.2/1.3 grids (Quantifoil) and incubated in a FEI Vitrobot IV at 4°C and 95% humidity for 20 sec ...
-
bioRxiv - Microbiology 2021Quote: ... 3μL of protein was deposited on a holey copper grids (QUANTIFOIL R 1.2/1.3, 200 mesh, EMS) which had been glow-discharged for 30s at 15 mA (Tedpella Inc) ...
-
bioRxiv - Biophysics 2023Quote: 4 μL purified protein was placed on the holy-carbon grids (Quantifoil Au R1.2/1.3, 300 mesh), which were glow-discharged for 30 s ...
-
bioRxiv - Biochemistry 2023Quote: ... 3 μl diluted protein sample was put on freshly glow-discharged Quantifoil R1.2/1.3 Cu grid (Quantifoil Micro Tools GmbH ...
-
bioRxiv - Biophysics 2021Quote: ... 2.8 ul of the mixture was applied onto glow discharged (5 mA, 20 sec) R1.2/1.3 holey carbon gold grids (300 mesh, Quantifoil) at 22°C and 100% humidity ...
-
bioRxiv - Microbiology 2022Quote: ... the amoebae (5×105 per well) were seeded onto EM gold finder grids (Au NH2 R2/2, Quantifoil) and incubated for 1 h ...
-
bioRxiv - Biochemistry 2023Quote: ... The most concentrated fraction was spun for 5 min at 13K rpm before applying 3 µL to UltraAuFoil R1.2/1.3 gold support grids (Quantifoil). Prior to sample applications grids were glow-discharged for 3 min in Pelco easiGlow glow-discharger (Pelco ...
-
bioRxiv - Microbiology 2023Quote: Four microliters of purified TilA-TslA-TlaA1-TlaA2 complex at 0.5 mg ml-1 in Buffer B (Supplementary Table 5) was applied onto glow-discharged (60 s, 30 mA) 300 mesh R1.2/1.3 Au grids (Quantifoil). Grids were blotted for 3 s with blot force of +15 at 10°C and 100% humidity ...
-
bioRxiv - Biochemistry 2023Quote: A 3.5 μL concentrated SPARTA sample was loaded onto a glow discharged UltrAuFoil 300 mesh R1.2/1.3 grids (Quantifoil) using a FEI Vitrobot at 4°C and 100% humidity ...
-
bioRxiv - Microbiology 2023Quote: ... 2.2µl of the purified mixture at a concentration of 0.5 mg/mL was applied to glow discharged (30 s at 25mA) grid (300 mesh 1.2/1.3, Quantifoil). The grids were blotted for 3.5 s before plunging into liquid ethane using Vitrobot MK4 (TFS ...
-
bioRxiv - Biophysics 2021Quote: ... 2.0 μL of the protein sample was applied to 300 mesh Cu Quantifoil 1.2/1.3 grids (Quantifoil Microtools) that were glow discharged for 20 seconds at 25 mA ...
-
bioRxiv - Biophysics 2020Quote: ... Aliquots (3.5 μl) of protein solution were loaded onto glow-discharged holey carbon grids (Quantifoil Au R1.2/1.3), which were blotted for 3.5 s and immersed in liquid ethane cooled by liquid nitrogen using Vitrobot (Mark IV ...
-
bioRxiv - Molecular Biology 2022Quote: ... 3 μl of protein sample was applied to holey carbon grids (Quantifoil, R 0.6/1 Cu 200 mesh) which were H2/O2 glow-discharged for 30 s ...
-
bioRxiv - Plant Biology 2021Quote: ... 2.5 μl L7TIR protein (1mg/ml) was applied to holey carbon grids (Quantifoil Au 1.2/1.3, 300 mesh) glow-discharged for 30 s at high level in Harrick Plasma after 2 min evacuation ...
-
bioRxiv - Immunology 2021Quote: ... Then 3 μl of the protein mixture was applied to a Quantifoil-Cu-2/1-3C grid (Quantifoil) pretreated by glow-discharging at 15 mA for 1 min ...
-
bioRxiv - Immunology 2022Quote: ... 3 μL of the DCFHP proteins were applied onto a glow-discharged Quantifoil R 1.2/1.3 Cu 300-mesh grid (Quantifoil). The grids were blotted for 2 sec at 20°C and 100% humidity and rapidly cryocooled in liquid ethane using a Vitrobot Mark IV instrument (Thermo Fisher Scientific) ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... 3 μl of the protein complex was applied onto 300 mesh R1.2/1.3 UltrAuFoil Holey gold support films (Quantifoil). For cryo-EM grids preparation of DHA-FFA4-miniGq complex ...
-
bioRxiv - Molecular Biology 2023Quote: ... 3μL of protein was deposited on holey carbon copper grids (QUANTIFOIL R 1.2/1.3-2nm, 300 mesh, EMS) which had been glow-discharged for 20s at 15 mA using PELCO easiGlow (TedPella Inc) ...
-
bioRxiv - Microbiology 2021Quote: ... and 5 µl of the mixture was placed onto freshly glow discharged holey carbon grids (R 2/1, Quantifoil) for 1 min ...
-
bioRxiv - Physiology 2021Quote: ... Aliquots of 1.25 – 1.5 μl RyR1-Nanodisc were applied onto each side of glow-discharged UltraAufoil −1.2/1.3 holey-gold (Quantifoil, Germany) with 300 TEM mesh ...
-
bioRxiv - Cell Biology 2019Quote: ... Liquid culture (5 μL, ~1000 cells/μL) was blotted onto carbon-coated 200-mesh copper grids (Quantifoil Micro Tools), which were then plunged into a liquid ethane-propane mixture using a Vitrobot Mark 4 (FEI Thermo Fisher) ...
-
bioRxiv - Biophysics 2021Quote: ... aliquots (3 μL) of the concentrated protein were placed on glow-discharged holey carbon grids (Quantifoil Au R1.2/1.3) and blotted for 5 s ...
-
bioRxiv - Biophysics 2022Quote: Cryo-EM grids were prepared by applying 3 μL of protein to a glow-discharged QuantiAuFoil R1.2/1.3 300-mesh grid (Quantifoil, Germany) and blotted for 2.5 to 4 s under 100% humidity at 4 °C before plunging into liquid ethane using a Mark IV Vitrobot (FEI).
-
bioRxiv - Biophysics 2019Quote: ... 20 nL of the 25 nL eluate containing the purified protein was primed on a 400-mesh copper grid covered with a holey carbon film (R1.2/1.3, Quantifoil, Germany) that was glow discharged for 45 s in air plasma immediately before use ...
-
bioRxiv - Biophysics 2020Quote: Cryo-EM grids were prepared by applying freshly purified channel protein (~3.5 μl) to glow-discharged copper Quantifoil R2/2 holey carbon grids (Quantifoil), which were then blotted for 2 s with ~100% humidity and flash frozen in liquid ethane using FEI Vitrobot Mark IV (FEI) ...
-
bioRxiv - Bioengineering 2020Quote: ... Aliquots (3.3 μL) of the protein complex were placed on glow-discharged holey carbon grids (Quantifoil Au R1.2/1.3). The grids were blotted for 2.5 s or 3.0 s and flash-frozen in liquid ethane cooled by liquid nitrogen with Vitrobot (Mark IV ...
-
bioRxiv - Microbiology 2023Quote: ... 3 μL of 3 mg/mL of protein was added to glow discharged UltrAuFoil holey gold grid (Quantifoil GmbH) using a Vitrobot Mark IV (Thermofisher ...
-
bioRxiv - Biochemistry 2022Quote: ... An aliquot of 3.5 μl of sample was placed on the glow-discharged cryo-EM grid (Quantifoil R1.2/1.3 or Quantifoil R2/1), blotted and plunge-frozen in liquid ethane using a Mark VI Vitrobot instrument maintained at 100% humidity with blot force 20 and blot time of 3 seconds ...
-
bioRxiv - Biochemistry 2022Quote: ... Three μL of sample at 5 μM was adsorbed onto glow-discharged copper Quantifoil R2/1 holey carbon grids (Quantifoil). Grids were glow discharged 45 seconds at 25 mA using an EMITECH K950 apparatus ...
-
bioRxiv - Cell Biology 2023Quote: ... and 5% (w/v) glycerol was applied to a Quantifoil 300-mesh R1.2/1.3 grid (Quantifoil, Micro Tools GmbH, Germany), which had been pre-treated with glow discharge using Pelco EasiGlow immediately before use ...