Labshake search
Citations for Quantifoil Micro Tools :
401 - 450 of 662 citations for Sodium Monofluoroacetate 90% Cp 13C2 99%; 2 2 D2 98% 1 Mg Ml In Water since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Microbiology 2019Quote: ... The EM-grids were glow-discharged 200 mesh copper grids with an extra thick R2/2 carbon film (Quantifoil Micro Tools). 3,5 µl of the sample was applied to the EM grid and blotted at a temperature of 16°C and a humidity between 95-99% ...
-
bioRxiv - Biophysics 2019Quote: ... The Netherlands) as fiducial markers and glow-discharged R2/2 Cu 300 mesh holey carbon-coated support grids (Quantifoil, Jena, Germany) were dipped into the solution ...
-
bioRxiv - Biophysics 2020Quote: ... samples were stored on ice and applied to the cryo-grids (2 nm precoated Quantifoil R3/3 holey carbon supported grids) at a concentration of 10 μM and vitrified using a Vitrobot Mark IV (FEI) ...
-
bioRxiv - Plant Biology 2021Quote: ... 3 µl of suspended cells in culture medium were applied to the front side of glow-discharged R2/2 carbon-coated copper grids (Quantifoil MicroTools), with additional 1 µL cells added to the back side ...
-
bioRxiv - Microbiology 2020Quote: ... 3 μL of the sample mixture was applied to a freshly glow-discharged copper R2/2 200 grid (Quantifoil Micro Tools), pre-blotted for 30 seconds ...
-
bioRxiv - Biochemistry 2021Quote: ... Three microliters of the protein solution were applied on a glow-discharged holey carbon grids (200 mesh Quantifoil R2/2 molybdenum), which had been treated with H2 and O2 mixtures in a Solarus plasma cleaner (Gatan ...
-
bioRxiv - Biophysics 2023Quote: ... 3 to 3.5 μl of complex was applied to a glow-discharged UltrAuFoil Holey Gold 200 mesh R2/2 grid (Quantifoil, Catalog # Q250AR2A) and incubated in a FEI Vitrobot IV chamber at 4°C and 95% humidity for 20 sec ...
-
bioRxiv - Molecular Biology 2021Quote: The purified tirzepatide–GIPR–Gs–Nb35 complex at a concentration of 18-20 mg/mL was mixed with 100 μM tirzepatide at 4°C and applied to glow-discharged holey carbon grids (Quantifoil R1.2/1.3, Au 300 mesh) that were subsequently vitrified by plunging into liquid ethane using a Vitrobot Mark IV (ThermoFisher Scientific) ...
-
bioRxiv - Microbiology 2023Quote: Aliquots of 3.5 μL SbtA-SbtB (ΔT-loop) samples (∼6 mg/mL) were applied to the glow-discharged grids (Quantifoil holey carbon Cu R1.2/1.3 grid). Grids were blotted for 4.5 sec and plunge-frozen in liquid ethane vitrified by liquid nitrogen using Vitrobot Mark IV (FEI Company ...
-
bioRxiv - Biophysics 2023Quote: 2.5μL aliquots of Fks1 at a concentration of about 3 mg/mL were placed on glow-discharged holey carbon grids (Quantifoil Au R1.2/1.3, 300 mesh) and were flash-frozen in liquid ethane using a FEI Vitrobot Mark IV ...
-
bioRxiv - Biochemistry 2024Quote: IN-IBD complex (0.1 mg/mL) was applied onto freshly plasma cleaned (20s, Solarus plasma cleaner) holey grids (Quantifoil UltrAufoil R 1.2/1.3 300 mesh) at 4°C in the cold room with ∼90% humidity ...
-
bioRxiv - Molecular Biology 2023Quote: ... 3μL of the purified complex at a concentration of 5.72 mg/mL was applied to glow-discharged holey carbon grids (Quantifoil R1.2/1.3, Au/C 300 mesh) that were subsequently vitrified by plunging into liquid ethane using a Vitrobot Mark IV (ThermoFisher Scientific ...
-
bioRxiv - Biochemistry 2023Quote: ... Four microliters of purified Cx36 proteins (4-6 mg/ml) were applied onto a negatively glow-discharged holey carbon grid (Quantifoil R1.2/1.3 Cu 300 mesh). For samples involving Cx36-WT ...
-
bioRxiv - Biophysics 2021Quote: 3 μl of the human sperm sample were applied to glow discharged copper R2/2 200-mesh holey carbon grid (Quantifoil Micro Tools) and plunge frozen in liquid ethane using an automatic plunge freezer (Vitrobot ...
-
bioRxiv - Cell Biology 2020Quote: ... Cells were incubated at 37°C and 5% CO2 for 16h prior to trypsinization and seeding onto 200 mesh gold holey carbon grids (R2/2-2C; Quantifoil Micro Tools), which were placed in 3D printed grid holders [39] ...
-
bioRxiv - Molecular Biology 2021Quote: ... 3 μL aliquots of the cell suspension were applied to glow-discharged R2/2 200 mesh copper Quantifoil grids (Quantifoil Micro Tools), the sample was pre-blotted for 30 seconds ...
-
bioRxiv - Molecular Biology 2021Quote: ... After another 3 min at 37 °C the termination complexes were placed on ice for 15 min and subsequently applied to Quantifoil R2/2 holey carbon grids (Quantifoil Micro Tools) either coated with a thin continuous carbon film or with graphene oxide flakes (Sigma-Aldrich) ...
-
bioRxiv - Cell Biology 2021Quote: ... 4 µl of the solution was applied to a glow-discharged (30s at 35 mA) copper R2/2 holey carbon grid (Quantifoil Micro Tools). After removing excess liquid by blotting the grid from the back side with Whatman filter paper for 2 s ...
-
bioRxiv - Cell Biology 2020Quote: ... Samples were applied to freshly glow-discharged (Edwards S150B, 45 sec, 30-50 mA, 1,2kV, 10-2 mbar) copper holey carbon grids (Quantifoil, Cu-R1.2/1.3) under 100% humidity ...
-
bioRxiv - Molecular Biology 2022Quote: ... 3 μl of the mixture was deposited on glow discharged R2/2 Copper 300 mesh holey carbon-coated support grids (Quantifoil, Jena, Germany) along with 1 μl of HEPES pH 10 and 1 μl of hydrogen peroxide 0.9 % ...
-
Genome modularization reveals overlapped gene topology is necessary for efficient viral reproductionbioRxiv - Synthetic Biology 2020Quote: A 4 μL solution of co-isolated small particles were applied to glow-discharged copper grids (Quantifoil R2/2, Quantifoil Micro Tools), blotting for 3-seconds at 4 °C with 90% humidity and plunging into liquid ethane using a Lecia EM GP device (Leica Microsystems ...
-
Genome modularization reveals overlapped gene topology is necessary for efficient viral reproductionbioRxiv - Synthetic Biology 2020Quote: A 4 μL solution of co-isolated small particles were applied to glow-discharged copper grids (Quantifoil R2/2, Quantifoil Micro Tools), blotting for 3-seconds at 4 °C with 90% humidity and plunging into liquid ethane using a Lecia EM GP device (Leica Microsystems ...
-
bioRxiv - Neuroscience 2021Quote: ... 400 mesh Quantifoil R1.2/1.3 grids with empty holes and 400 mesh Quantifoil R1.2/1.3 grids coated with a 2 nm thin carbon layer (Quantifoil Micro Tools GmbH, Germany). The grids were rendered hydrophilic by glow discharge using a Pelco easiGlow glow discharger (Ted Pella Inc. ...
-
bioRxiv - Microbiology 2020Quote: ... Cells were concentrated by centrifugation and 3 μL aliquots of the cell suspension are applied to glow-discharged R2/2 200 mesh copper Quanti-foil grids (Quantifoil Micro Tools), the sample was pre-blotted for 30 seconds ...
-
bioRxiv - Cell Biology 2020Quote: ... A 5 µl drop of the chemically fixed cell culture was deposited on a glow-discharged Quantifoil 200 mesh R2/2 electron microscopy grid (Quantifoil, Großlöbichau, Germany) pre-coated with a gold bead solution ...
-
Computational toolbox for ultrastructural quantitative analysis of filament networks in cryo-ET databioRxiv - Cell Biology 2021Quote: B16-F1 cells were cultured as described above and seeded onto 200 mesh gold holey carbon grids (R2/2-2C; Quantifoil Micro Tools). Prior to cell seeding ...
-
Mycobacteria form viable cell wall-deficient cells that are undetectable by conventional diagnosticsbioRxiv - Microbiology 2022Quote: ... of which 3-4 µL was applied on glow-discharged 200 mesh copper grids with an extra thick R2/2 carbon film (Quantifoil Micro Tools). Vitrification was performed using an automated Leica EM GP plunge-freezer ...
-
bioRxiv - Cell Biology 2022Quote: ... 3 μl of the resulting mixture was spotted onto glow-discharged copper EM grids (Quantifoil 300 Au mesh, R2/2 carbon film (Quantifoil Micro Tools). The grids were then blotted for 2 or 4 seconds (blot force −10 ...
-
bioRxiv - Cell Biology 2022Quote: ... 3 µl of the microtubule sample was deposited at the surface of a glow-discharged holey carbon grid (Quantifoil R2/2, Cu200) in the temperature (35 °C ...
-
bioRxiv - Biochemistry 2023Quote: ... Samples were applied to freshly glow-discharged (Edwards S150B, 45 s, 30−50 mA, 1.2 kV, 10−2 mbar) copper holey carbon grids (Quantifoil, Cu-R1.2/1.3) under 100% humidity at 4°C.
-
bioRxiv - Biochemistry 2023Quote: 4.5 µL of freshly mixed Nup98 condensate and capsid mixture with protein A-gold (10 nm) were applied onto a glow-discharged Quantifoil R2/2 copper grid (Quantifoil Micro Tools). The grid was blotted in the front for 2.5 s at 15 °C with 90% relative humidity and then plunged into liquid ethane using a Lecia EM GP device (Lecia Microsystem) ...
-
bioRxiv - Cell Biology 2024Quote: ... An aliquot of a 5 μl sample was applied to a glow-discharged holey carbon grid (Quantifoil R2/2, Au, 400 mesh). After waiting for 60 s ...
-
bioRxiv - Biophysics 2022Quote: Purified wt or mutant D263A or F55A MVMp capsid samples (5 μl) were applied onto R2/2 300 mesh copper grids (Quantifoil Micro Tools, Germany) and vitrified using a Leica EM CPC cryofixation unit ...
-
bioRxiv - Biochemistry 2020Quote: ... 3 μl aliquots of purified mitoribsomes was incubated for 30 s on glow-discharged holey carbon grids (Quantifoil R2/2, 300 mesh, copper) pre-coated with a home-made continuous carbon film with thickness of ~ 27 Å ...
-
bioRxiv - Cancer Biology 2020Quote: ... 3 μL of urease samples at 1.3 mg/mL with 1 mM BME or with 10 mM SHA were applied to freshly glow-discharged Quantifoil R2/2 holey carbon grids (Quantifoil Micro Tools, Germany). The grids were blotted for 4 seconds ...
-
bioRxiv - Biochemistry 2022Quote: ... and an aliquot of 2 μl of this sample was applied onto a plasma cleaned holey carbon grid (Quantifoil, R1.2/1.3, 200 mesh). The grid was blotted with Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Microbiology 2022Quote: A 5 µl cell suspension containing 10 nm colloidal gold particles were deposited on the copper EM grids with holey carbon supported film (Quantifoil, 200mesh, R1/2). The EM grid were blotted with filter paper (Waterman ...
-
bioRxiv - Cell Biology 2022Quote: ... A 3 µl volume of the Kif5B suspension was first deposited at the surface of a glow-discharged holey carbon grid (Quantifoil R2/2, Cu200) in the temperature (23 °C ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: Grids were prepared by applying 3.5 μLs of the Z7757 complex or 2 μLs of the Lisuride complex to glow discharged UltrAuFoil holey gold grids (Quantifoil, Au300-R1.2/1.3). The girds containing Z7757 were then vitrified by plunge freezing into a 60/40 mixure of liquid ethane/propane using a Vitrobot mark IV (FEI ...
-
bioRxiv - Cell Biology 2020Quote: 4 µl of the cultured yeast cells (OD600 of 0.4) were added to a glow-discharged (30 seconds at -30 mA) copper R2/2 holey carbon grid (Quantifoil Micro Tools GmbH, Jena, Germany), then the grid was rapidly plunge frozen in liquid ethane using a homemade plunge freezer and stored in liquid nitrogen until used ...
-
bioRxiv - Cell Biology 2022Quote: ... 4 µL of the mixture were pipetted onto a copper EM grid with holey carbon film (R2/2, 200 mesh, Quantifoil Micro Tools GmbH, Q43486) that had been freshly glow-discharged for 30 s at -30 mAmp ...
-
bioRxiv - Pathology 2023Quote: ... bombycis spores (1×105 spores/mL) were placed on nickel grids (Quantifoil, Beijing, China) for 15 min and germinated in 0.1 M KOH for 30 min at 30°C ...
-
bioRxiv - Microbiology 2020Quote: ... A small volume (4 µL) of cells was then transferred onto freshly glow‐discharged copper R2/2 200 Quantifoil holey carbon grids (Quantifoil Micro Tools GmbH, Jena, Germany). Grids were then blotted and plunge‐frozen in a liquid ethane/propane mixture 31 using an FEI Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Biochemistry 2022Quote: ... Samples were prepared by depositing 3 μl of the crystalline slurry onto a glow-discharged EM grid (Quantifoil, Cu 200 mesh, R2/2 holey carbon). Excess liquid was blotted away and the sample was vitrified using a Leica GP2 vitrification robot ...
-
bioRxiv - Molecular Biology 2022Quote: 3 μL of ~120 nM mitoribosome was applied onto a glow-discharged (20 mA for 30 sec) holey-carbon grid (Quantifoil R2/2, copper, mesh 300) coated with continuous carbon (of ~3 nm thickness ...
-
bioRxiv - Cell Biology 2019Quote: ... 4 µl of the solution was applied to a glow-discharged (30 s at −35 mA) copper R2/2 holey carbon grid (Quantifoil Micro Tools GmbH, Jena, Germany). After removing excess liquid by blotting the grid from the back side with Whatman filter paper No ...
-
bioRxiv - Microbiology 2019Quote: ... Four μl of this mixture was applied onto freshly glow-discharged copper R2/2 of th0 Quantifoil holey carbon grids (Quantifoil Micro Tools GmbH, Jena, Germany). Using an FEI Vitrobot Mark IV ...
-
bioRxiv - Biophysics 2020Quote: ... 2 μL of a 1 in 6 dilution of the batch crystallisation was applied to the carbon side of glow discharged R2/2 Quantifoil™ grids (Quantifoil Micro Tools, Jena, Germany). Excess liquid was removed by blotting for 4-6 s with a Vitrobot (Thermo Fisher ...
-
bioRxiv - Microbiology 2020Quote: ... 3.5 μl of that mixture was transferred to a 3 mm freshly glow-discharged Quantifoil R2/2 Cu 300 mesh holey carbon grid (Quantifoil Micro Tools GmbH, Jena, Germany). Excess liquid was blotted away using a Leica EM GP plunge-freezer at room temperature and 80% humidity (blot time 2-3 sec ...
-
bioRxiv - Molecular Biology 2022Quote: ... The pellet was then resuspended in warm EM buffer and 3 μL of this sample was applied to a carbon on gold grid (Quantifoil R2/2 Au 200 mesh), recently glow-discharged for 1 min at 30 mA ...