Labshake search
Citations for Quantifoil Micro Tools :
1 - 50 of 102 citations for Mouse Anti Hepatitis C Virus Core Protein Antibody 1864 since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Evolutionary Biology 2022Quote: ... The proteins were incubated at 37°C and 200 rpms for 10 minutes on a microplate shaker (BioShake iQ; Quantifoil Instruments ...
-
bioRxiv - Evolutionary Biology 2022Quote: ... The proteins were incubated at 37°C and 200 rpms for 10 minutes on a microplate shaker (Quantifoil Instruments, Jena, Germany). Next ...
-
bioRxiv - Microbiology 2020Quote: ... 3,5 μl of the culture was mixed with 10 nm gold fiducial markers (Cell Microscopy Core, UMC Utrecht) and applied onto glow-discharged R2/2 200 mesh holey carbon EM grids (Quantifoil). The grid was then rapidly plunged in liquid ethane using the Leica GP automated freeze-plunger ...
-
bioRxiv - Cell Biology 2019Quote: Freshly purified RS head core complex (0.4 mg/ml) was placed onto glow-discharged grids (Quantifoil R1.2/1.3 200 mesh Cu grids) and plunge-frozen into liquid ethane ...
-
bioRxiv - Molecular Biology 2023Quote: ... The purified virus was applied onto glow-discharged electron microscopy grids covered with holey carbon (Quantifoil, SPT Labtech, Melbourn, UK), blotted ...
-
PSGL-1 inhibits HIV-1 infection by restricting actin dynamics and sequestering HIV envelope proteinsbioRxiv - Microbiology 2020Quote: ... A 3.5 µL virus sample solution was applied onto a glow discharged copper grid coated with holey carbon (R2/1; Quantifoil, Jena, Germany) prior to plunge-freezing ...
-
bioRxiv - Microbiology 2020Quote: ... 3.5 microliters of the purified virus sample was pipetted onto a glow-discharged R2/1 Quantifoil grid (Quantifoil Micro Tools GmbH, Jena, Germany), blotted for 2.5 seconds ...
-
bioRxiv - Molecular Biology 2022Quote: ... The plus carbon sample (Quantifoil Cu300 R2/1 + 2 nm C) was blotted for 2 s with blot force +3 after a 30 s wait time after sample application and immediately plunge frozen in liquid ethane ...
-
bioRxiv - Molecular Biology 2022Quote: ... An aliquot of 4 μL protein sample of Spike protein was applied onto a glow-discharged 300 mesh grid (Quantifoil Au R1.2/1.3) and GraFuture™-RGO grid which was supported with a thin layer of RGO (reduced graphene oxide) ...
-
bioRxiv - Neuroscience 2020Quote: ... covered with either 2 nm amorphous carbon (Quantifoil, R2/1+2 nm C) or graphene were used for sample preparation ...
-
bioRxiv - Biophysics 2020Quote: ... The protein was spotted onto UltraAuFoil 1.2/1.3 gold grids (Quantifoil) plasma cleaned using an Ar/O2 gas mix ...
-
bioRxiv - Biochemistry 2021Quote: ... C-flat grids (Protochips, USA; 1.2/1.3 300 mesh) and UltrAuFoil (Quantifoil, Germany; 1.2/1.3 300 mesh) were negatively glow discharged using PELCO Easiglow (Ted Pella ...
-
bioRxiv - Immunology 2021Quote: ... by shaking at 1200 rpm for 5 minutes at 37°C using a plate shaker (Quantifoil Instruments) after stimulating with collagen at a range of concentrations ...
-
bioRxiv - Biophysics 2020Quote: ... Protein was frozen on R 1.2/1.3 grids with 300 Au mesh (Quantifoil, Germany). This dataset was collected at UCSF on the Titan Krios 2 ...
-
bioRxiv - Biophysics 2020Quote: The purified N protein was prepared on UltraAuFoil R1.2/1.3 gold support grids (Quantifoil). 3 µl of sample was applied to glow-discharged grids ...
-
bioRxiv - Biophysics 2023Quote: ... by applying protein to glow-discharged QuantiFoil Au R1.2/1.3 200-mesh grids (Quantifoil), blotting for 3.0 s under 100% humidity at 4°C ...
-
bioRxiv - Biochemistry 2022Quote: ... 2 μl retromer at a concentration between 80-100 μg/ml was applied to freshly glow discharged CF-2/2-2C C-Flat grids (Protochips, Morrisville, NC) or Quantifoil R 1.2/1.3 300 mesh copper grids (Quantifoil Micro Tools GmbH ...
-
bioRxiv - Biophysics 2020Quote: Three microliters of purified HCoV-NL63 virions (4.5 mg/mL) were first applied to 300-mesh R2/1 + 2 nm C-film grids (Quantifoil) that had been glow-discharged for 15s PELCO easiGlow (TED PELLA ...
-
bioRxiv - Cell Biology 2022Quote: Cells were trypsinized and seeded onto 200 mesh gold holey carbon grids (R2/2-2 C, Quantifoil Micro Tools) placed in 3D printed grid holders (51 ...
-
bioRxiv - Immunology 2023Quote: ... The plate was then mixed (200rpm; 37°C) for 20 minutes in the dark (BioShake iQ, Quantifoil Instruments GmbH). Samples were fixed with 1% formalin and run on the Cytek Aurora 5-laser flow cytometer (Cytek Biosciences) ...
-
bioRxiv - Biophysics 2024Quote: ... Aliquots of 1.25 – 1.5 ul RyR1-nanodisc were applied onto each side of glow-discharged C-Flat - 2/1 - 3Au holey-carbon (Protochips, NC) or UltraAufoil -1.2/1.3 holey-gold (Quantifoil, Germany) with 300 TEM mesh ...
-
bioRxiv - Biochemistry 2019Quote: ... 2 μl 60 μM H6-TtBac in Buffer C were added onto freshly glow-discharged Quantifoil Cu/Rh R2/2 holey carbon 200 mesh grids (Quantifoil). The grids were blotted for 2.5 s with a blotting force of −15 ...
-
bioRxiv - Cell Biology 2021Quote: ... Aggregation was stimulated with TRAP-6 (25μM) in a 96-well plate (15 minutes, 750rpm, 37°C; BioShake IQ, Quantifoil Instruments) and fixed with 1% formalin (Sigma) ...
-
bioRxiv - Biochemistry 2022Quote: ... 3.0 μL of sample was applied to glow-discharged 200-mesh copper 2 nm C R1.2/1.3 cryo-EM grids (Quantifoil Micro Tools), blotted 1 s at 100 % humidity ...
-
bioRxiv - Biochemistry 2022Quote: ... 2.5 μL of sample was applied to glow-discharged 200-mesh copper 2 nm C R1.2/1.3 cryo-EM grids (Quantifoil Micro Tools), blotted 3 s at 75 % humidity ...
-
bioRxiv - Biochemistry 2021Quote: ... 3.5 μL sample was applied onto a freshly glow-discharged 200-mesh copper 2 nm C R1.2/1.3 grids (Quantifoil Micro Tools). The grids were blotted for 1 s and plunge-vitrified in liquid ethane ...
-
bioRxiv - Biochemistry 2023Quote: 2.4 µL of sample were applied to a freshly glow discharged 200-mesh Cu + 2 nm C R1.2/1.3 grid (Quantifoil Micro Tools), blotted for 6 s at 100% humidity ...
-
bioRxiv - Immunology 2021Quote: The purified and cross-linked recombinant NLRP3 protein was loaded onto glow-discharged EM-grids (Quantifoil, R2/1 Cu-covered with homemade ultrathin carbon support film) ...
-
bioRxiv - Biophysics 2020Quote: ... The protein was then blotted onto Cu 300 mesh Quantifoil 1.2/1.3 grids (Quantifoil Micro Tools) two times with 3.5 μl sample each time ...
-
bioRxiv - Plant Biology 2023Quote: ... 3 μl protein was applied to glow-discharged carbon grids (Quantifoil Cu R1.2/1.3 300 mesh). Subsequently ...
-
bioRxiv - Cell Biology 2020Quote: ... 3.5 μL of the sample was applied to glow-discharged R1.2/1.3 holey carbon grids (Quantifoil Au or C-flat Cu). The grids were blotted for 3.5 s at 4°C and 100% humidity ...
-
bioRxiv - Microbiology 2021Quote: ... 3μL of protein was deposited on a holey copper grids (QUANTIFOIL R 1.2/1.3, 200 mesh, EMS) which had been glow-discharged for 30s at 15 mA (Tedpella Inc) ...
-
bioRxiv - Biophysics 2023Quote: 4 μL purified protein was placed on the holy-carbon grids (Quantifoil Au R1.2/1.3, 300 mesh), which were glow-discharged for 30 s ...
-
bioRxiv - Biochemistry 2023Quote: ... 3 μl diluted protein sample was put on freshly glow-discharged Quantifoil R1.2/1.3 Cu grid (Quantifoil Micro Tools GmbH ...
-
bioRxiv - Cell Biology 2021Quote: ... Glow-discharged holey Quantifoil grids with an additional layer of continuous carbon (R2/1 + 2 nm C, Cu 200 mesh grid, Quantifoil Micro Tools) were used ...
-
bioRxiv - Biophysics 2021Quote: ... 2.0 μL of the protein sample was applied to 300 mesh Cu Quantifoil 1.2/1.3 grids (Quantifoil Microtools) that were glow discharged for 20 seconds at 25 mA ...
-
bioRxiv - Biophysics 2020Quote: ... Aliquots (3.5 μl) of protein solution were loaded onto glow-discharged holey carbon grids (Quantifoil Au R1.2/1.3), which were blotted for 3.5 s and immersed in liquid ethane cooled by liquid nitrogen using Vitrobot (Mark IV ...
-
bioRxiv - Molecular Biology 2022Quote: ... 3 μl of protein sample was applied to holey carbon grids (Quantifoil, R 0.6/1 Cu 200 mesh) which were H2/O2 glow-discharged for 30 s ...
-
bioRxiv - Plant Biology 2021Quote: ... 2.5 μl L7TIR protein (1mg/ml) was applied to holey carbon grids (Quantifoil Au 1.2/1.3, 300 mesh) glow-discharged for 30 s at high level in Harrick Plasma after 2 min evacuation ...
-
bioRxiv - Immunology 2021Quote: ... Then 3 μl of the protein mixture was applied to a Quantifoil-Cu-2/1-3C grid (Quantifoil) pretreated by glow-discharging at 15 mA for 1 min ...
-
bioRxiv - Immunology 2022Quote: ... 3 μL of the DCFHP proteins were applied onto a glow-discharged Quantifoil R 1.2/1.3 Cu 300-mesh grid (Quantifoil). The grids were blotted for 2 sec at 20°C and 100% humidity and rapidly cryocooled in liquid ethane using a Vitrobot Mark IV instrument (Thermo Fisher Scientific) ...
-
bioRxiv - Molecular Biology 2023Quote: ... 3μL of protein was deposited on holey carbon copper grids (QUANTIFOIL R 1.2/1.3-2nm, 300 mesh, EMS) which had been glow-discharged for 20s at 15 mA using PELCO easiGlow (TedPella Inc) ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... 3 μl of the protein complex was applied onto 300 mesh R1.2/1.3 UltrAuFoil Holey gold support films (Quantifoil). For cryo-EM grids preparation of DHA-FFA4-miniGq complex ...
-
bioRxiv - Biophysics 2023Quote: ... The collagen fibrils were transferred to glow-discharged electron microscopy grid by peeling off the collagen gel drop surface with the grid (purchased from QuantiFoil, C support Cu400), which was left on the collagen surface between 1 to 12 hours ...
-
bioRxiv - Biophysics 2021Quote: ... aliquots (3 μL) of the concentrated protein were placed on glow-discharged holey carbon grids (Quantifoil Au R1.2/1.3) and blotted for 5 s ...
-
bioRxiv - Biophysics 2022Quote: Cryo-EM grids were prepared by applying 3 μL of protein to a glow-discharged QuantiAuFoil R1.2/1.3 300-mesh grid (Quantifoil, Germany) and blotted for 2.5 to 4 s under 100% humidity at 4 °C before plunging into liquid ethane using a Mark IV Vitrobot (FEI).
-
bioRxiv - Biophysics 2019Quote: ... 20 nL of the 25 nL eluate containing the purified protein was primed on a 400-mesh copper grid covered with a holey carbon film (R1.2/1.3, Quantifoil, Germany) that was glow discharged for 45 s in air plasma immediately before use ...
-
bioRxiv - Biophysics 2020Quote: Cryo-EM grids were prepared by applying freshly purified channel protein (~3.5 μl) to glow-discharged copper Quantifoil R2/2 holey carbon grids (Quantifoil), which were then blotted for 2 s with ~100% humidity and flash frozen in liquid ethane using FEI Vitrobot Mark IV (FEI) ...
-
bioRxiv - Bioengineering 2020Quote: ... Aliquots (3.3 μL) of the protein complex were placed on glow-discharged holey carbon grids (Quantifoil Au R1.2/1.3). The grids were blotted for 2.5 s or 3.0 s and flash-frozen in liquid ethane cooled by liquid nitrogen with Vitrobot (Mark IV ...
-
bioRxiv - Microbiology 2023Quote: ... 3 μL of 3 mg/mL of protein was added to glow discharged UltrAuFoil holey gold grid (Quantifoil GmbH) using a Vitrobot Mark IV (Thermofisher ...