Labshake search
Citations for Quantifoil Micro Tools :
1 - 50 of 133 citations for Graphene Nanopowder AO 4 60nm Flakes 100g since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Molecular Biology 2022Quote: Graphene oxide (GO) grids were prepared from Quantifoil R1.2/1.3 grids ...
-
bioRxiv - Molecular Biology 2022Quote: ... for 15 min before 4 μL of sample was applied to a graphene oxide coated 1.2/1.3 UltrAuFoil grids (Quantifoil) at 4°C under 100% humidity86 ...
-
bioRxiv - Biochemistry 2022Quote: A total of 3880 (graphene grid) and 3075 (Au Quantifoil grid) raw movie stacks were automatically collected on a 300 kV Titan Krios using a K3 direct electron detector (with a BioQuantum energy filter ...
-
bioRxiv - Biophysics 2022Quote: ... and applied to the graphene oxide grid (Quantifoil Au 1.2/1.3, 300 mesh), which was glow-discharged (in a HARRICK PLASMA ...
-
bioRxiv - Molecular Biology 2024Quote: ... and immediately applied to a graphene oxide coated Holey Carbon 2/1 grids (Quantifoil) 83 ...
-
bioRxiv - Cell Biology 2024Quote: ... 2.5 – 3.51μL sample was applied to graphene oxide coated EM grids (Quantifoil Cu400 R1.2/1.3) following a previously published protocol(52) ...
-
bioRxiv - Biochemistry 2024Quote: ... Graphene oxide-coated Quantifoil R1.2/1.3 300 mesh copper holey carbon grids (Quantifoil Micro Tools) were glow discharged using a PELCO easiGlow Glow Discharge Cleaning system (Ted Pella ...
-
bioRxiv - Molecular Biology 2021Quote: ... a 3.5 μL aliquot at 0.1 mg·ml−1 was applied to one side of a Quantifoil 400 mesh 1.2/1.3 gold grid with graphene oxide support film (Quantifoil). After 30 s ...
-
bioRxiv - Biophysics 2021Quote: Graphene oxide coating was performed on 1.2/1.3 holey patterned carbon or gold film grids (Protochips or Quantifoil). To wash them ...
-
bioRxiv - Molecular Biology 2022Quote: ... 3.5 μL of purified protein at a concentration of 0.22 mg/mL was applied to Graphene Oxide Au 400 mesh QUANTIFOIL R1.2/1.3 holey carbon grids (Quantifoil), and then plunged into liquid nitrogen-cooled liquid ethane with a FEI Vitrobot Mark IV (FEI Thermo Fisher) ...
-
bioRxiv - Biophysics 2021Quote: ... 3.5 μl of purified protein at a concentration of 1.0 mg/ml was applied to Graphene Oxide Au 400 mesh QUANTIFOIL R1.2/1.3 holey carbon grids (Quantifoil), and then plunged into liquid nitrogen-cooled liquid ethane with a FEI Vitrobot Mark IV (FEI Thermo Fisher) ...
-
bioRxiv - Biochemistry 2021Quote: ... a 5 μl drop was applied to a graphene-treated and glow-discharged holey carbon grid (R 1.2/1.3 Quantifoil) for the BsClpP pH 4.2 sample and negatively glow-discharged holey carbon grid (R 1.2/1.3 Quantifoil ...
-
bioRxiv - Biochemistry 2023Quote: ... Cryo-EM grids were prepared by applying 3.5 μL of protein sample at a concentration of 0.25 mg/ml to one side of a Quantifoil 400 mesh 1.2/1.3 gold grid with graphene oxide support film (Quantifoil). After 30 s ...
-
bioRxiv - Biochemistry 2021Quote: ... Samples of ΦKZ nvRNAP were adsorbed to a thin film of graphene oxide deposited upon the surface of holey carbon copper grids (R2/1, 300 mesh, Quantifoil). Grids were blotted for 1-2 seconds before plunge freezing in liquid ethane using a Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Cell Biology 2020Quote: Samples of concentrated TSCCFL were adsorbed to a thin film of graphene oxide deposited upon the surface of holey carbon copper grids (R2/1, 300 mesh, Quantifoil). Grids were blotted for 2-3 seconds before plunge freezing in liquid ethane using a Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Biophysics 2024Quote: ... The sample was then loaded on a graphene oxide covered (homemade) holey carbon grid (Quantifoil R1.2/1.3, copper, 300 mesh) and plunge-frozen using a Vitrobot Mark IV (FEI/Thermo Fisher Scientific ...
-
bioRxiv - Biochemistry 2022Quote: ... The reported resolutions of the final maps (2.4 Å for the graphene grid and 2.9 Å for the Au Quantifoil grid) were estimated using the map versus model FSC curves (FSC0.5map vs ...
-
bioRxiv - Cell Biology 2024Quote: An aliquot of a 3μl purified PDC sample was applied to a holey carbon grid covered with graphene-oxide (Quantifoil R1.2/1.3, Au, 300 mesh). After waiting for 60 s ...
-
bioRxiv - Cell Biology 2020Quote: ... or holey SiO2 R1/4 TEM grids (Quantifoil) to allow for more robust correlation and cells were plunge frozen on a Vitrobot Mark IV (FEI ...
-
bioRxiv - Cell Biology 2022Quote: ... Grids (200 Mesh Cu SiO2 R1/4, Quantifoil) were plasma cleaned for 30 s before plunging ...
-
bioRxiv - Plant Biology 2020Quote: ... 4 μL of cell culture was blotted onto R 1/4 SiO2-coated 200-mesh gold EM grids (Quantifoil Micro Tools) and plunge frozen in a liquid ethane/propane mixture ...
-
bioRxiv - Biophysics 2024Quote: ... We glow-discharge-treated 200 mesh R1/4 or R2/4 Quantifoil holey carbon gold grids (Quantifoil®, Grossloebichau/Jena Germany) in a Pelco easiGlow (Ted Pella ...
-
bioRxiv - Cell Biology 2024Quote: ... and then 4 μL of the sample was applied to the glow-discharged R1/4 Carbon 200-mesh gold EM grid (Quantifoil Micro Tools). The EM grid was incubated in the chamber of Vitrobot (Vitrobot Mark 4 ...
-
bioRxiv - Biophysics 2021Quote: Gold EM grids with R1/4 holey SiO2 film (Quantifoil) were glow-discharged in a EasiGlow (Pelco ...
-
bioRxiv - Biophysics 2023Quote: 200 mesh Au grids with R1/4 SiO2 foil (Quantifoil) were glow-discharged for 90 sec at 0.38 mBar and 15 mA using a Pelco easiGlow device ...
-
bioRxiv - Neuroscience 2022Quote: ... Gold Quantifoil grids (R1/4, Au 200 mesh, Quantifoil Micro Tools) were additionally coated with a 20-25 nm carbon layer (MED 020 ...
-
bioRxiv - Cell Biology 2024Quote: ... with holey R 1/4 carbon film (Quantifoil Micro Tools GmbH) were glow-discharged for 30 seconds at 5 mA using an EasiGlow system (Pelco ...
-
bioRxiv - Biophysics 2024Quote: ... 2-4 chameleon self-wicking grids (Quantifoil Active 300 mesh; Quantifoil) were loaded into the instrument and glow discharged for 40-45 seconds at 12 mA ...
-
bioRxiv - Biophysics 2024Quote: ... 2-4 chameleon self-wicking grids (Quantifoil Active 300 mesh; Quantifoil) were loaded into the instrument and glow discharged for 40-45 seconds at 12 mA ...
-
bioRxiv - Microbiology 2023Quote: ... Gold grids with SiO2 film (Quantifoil, Au 200 mesh, R 1/4) were glow- discharged and coated with 20 µg/ml fibronectin solution for 30 min ...
-
bioRxiv - Microbiology 2024Quote: ... 4 µl sample was applied onto Au R2/2 200 mesh (Quantifoil) grids ...
-
bioRxiv - Biophysics 2021Quote: ... with 12-nm-thick holey R1/4 and R1.2/20 SiO2 film (Quantifoil) were used for the experiments ...
-
bioRxiv - Cell Biology 2021Quote: ... Gold Quantifoil grids (R1/4, Au 200 mesh grid, SiO2, Quantifoil Micro Tools) were glow-discharged and UV irradiated for 30 min for sterilization before being immersed in cell culture medium in 35-mm IBIDI μ-Dish ...
-
bioRxiv - Synthetic Biology 2023Quote: 4 µl of sample was adsorbed onto holey carbon-coated grid (Quantifoil, Germany) that was glow-discharged ...
-
bioRxiv - Neuroscience 2024Quote: ... gold mesh grids with holey R1/4 SiO2 film (Quantifoil Micro Tools GmbH) were glow discharged for 60s at 15 mA using an EasiGlow system ...
-
bioRxiv - Cell Biology 2024Quote: EM grids (Quantifoil R 1/4 Au 200 mesh, Quantifoil Micro Tools GmbH) were glow discharged with an Edwards S150B glow discharger at 30mA for 45sec on both sides of the grid ...
-
bioRxiv - Cell Biology 2024Quote: 4 µl of yeast cells were pipetted on Cu R2/1 grids (Quantifoil), blotted manually from the backside of the grid for ∼4 s and plunge frozen in liquid ethane using a manual plunger ...
-
bioRxiv - Biophysics 2020Quote: ... 4 µl sample was applied to each freshly glow-discharged grid (Quantifoil, R1.2/1.3). The grids were then plunge-frozen in liquid ethane ...
-
bioRxiv - Microbiology 2021Quote: ... 4-7 µl of cells were deposited on R2/1 Cu 200 grids (Quantifoil) that had been glow-discharged for 1 min at 0.19 mbar and 20 mA in a PELCO easiGlow device shortly before use ...
-
bioRxiv - Biophysics 2021Quote: ... 4 μl of cell suspension was applied to holey carbon R2/1 Cu grids (Quantifoil) and plunge-frozen on a Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Molecular Biology 2020Quote: ... 4 μl sample was applied onto Quantifoil grid Rh/Cu 200 R2/2 (Quantifoil, Inc), and was flash frozen into liquid ethane using a Vitrobot (FEI ...
-
bioRxiv - Cell Biology 2021Quote: ... 4 µl sample was applied onto Quantifoil grid Cu/Rh 200 R2/2 (Quantifoil, Inc), and was flash frozen into liquid ethane using a Vitrobot (FEI ...
-
bioRxiv - Biophysics 2024Quote: ... 4 µl of this sample was then applied to plasma-cleaned holey carbon grids (Quantifoil) and plunge frozen with an FEI vitrobot mark IV at 4°C and 100% humidity.
-
bioRxiv - Cell Biology 2024Quote: Quantifoil R2/1 or SiO2 R1/4 gold grids (both Quantifoil Mirco Tools GmbH, Germany) were briefly washed in chloroform and placed on drops of poly-D-lysine (100 µg/ml) ...
-
bioRxiv - Biochemistry 2023Quote: ... 4 μl of sample was applied to glow discharged Quantifoil 300 mesh 1.2/1.3 (Quantifoil) grids at 4 °C and 90-100% humidity ...
-
bioRxiv - Biophysics 2024Quote: 4 μL of sample were applied onto an UltrAuFoil grid (Quantifoil R1.2/1.3, 300 mesh), which was rendered hydrophilic by a 90 s treatment in an ELMO glow discharge system operating at 3 mA and in a partial vacuum of 3.6 × 10-1 mbar ...
-
bioRxiv - Biochemistry 2020Quote: ... 4 µL of sample was applied to Quantifoil Cu R 1.2/1.3 grids (Quantifoil Microtools GmbH) which has undergone a plasma discharge and were vitrified in liquid ethane using a Vitrobot MkIV plunge freezer (Thermo Fisher Scientific) ...
-
bioRxiv - Biophysics 2021Quote: ... Aliquots of 4 µl were applied to glow-discharged 300 mesh R1.2/1.3 Au grids (Quantifoil) using a Vitrobot Mark VI (Thermo Fisher Scientific ...
-
bioRxiv - Biophysics 2023Quote: ... 4 μL of Kapβ2•HNRNPH2 was applied to a 300 mesh copper grid (Quantifoil R1.2/1.3) that was glow-discharged using a PELCO easiGlow glow discharge apparatus at 30 mA/30 s on top of a metal grid holder (Ted Pella) ...
-
bioRxiv - Molecular Biology 2024Quote: ... 4 µl of the sample was applied onto freshly glow-discharged R2/1 carbon grids (Quantifoil), followed by grid blotting for 4 s and plunging into liquid ethane using a Vitrobot Mark IV (FEI ...