Labshake search
Citations for Quantifoil Micro Tools :
201 - 250 of 397 citations for Acyl protein thioesterase 2 LYPLA2 Human His since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Bioengineering 2020Quote: ... Aliquots (3.3 μL) of the protein complex were placed on glow-discharged holey carbon grids (Quantifoil Au R1.2/1.3). The grids were blotted for 2.5 s or 3.0 s and flash-frozen in liquid ethane cooled by liquid nitrogen with Vitrobot (Mark IV ...
-
bioRxiv - Microbiology 2023Quote: ... 3 μL of 3 mg/mL of protein was added to glow discharged UltrAuFoil holey gold grid (Quantifoil GmbH) using a Vitrobot Mark IV (Thermofisher ...
-
bioRxiv - Biochemistry 2021Quote: Three microliters of the h20S-PA26E102A-Opt5 solution were applied to R2/2 400-mesh grids (Quantifoil) that had been plasma treated for 25 s using a glow discharger (Electron Microscopy Sciences ...
-
bioRxiv - Cell Biology 2020Quote: ... and seeded onto a glow discharged holey carbon covered EM-grids (R 2/1, Au 200, Quantifoil). After approximately 16 h ...
-
bioRxiv - Molecular Biology 2022Quote: ... 3.5 μL was applied to freshly glow-discharged Quantifoil R2/2 300-square-mesh gold grids (Quantifoil) in a Vitrobot IV (ThermoFisher ...
-
bioRxiv - Biophysics 2020Quote: ... 2 μl apoferritin was applied to glow-discharged gold holey carbon 1.2/1.3 300-mesh grids (Quantifoil). Grids were blotted for 4 seconds at -2 force and vitrified in liquid ethane using a MarkIV Vitrobot (ThermoFisher) ...
-
bioRxiv - Molecular Biology 2023Quote: ... 3.5 μL was applied to freshly glow discharged Quantifoil R2/2 300-square-mesh gold grids (Quantifoil) in a Vitrobot IV (ThermoFisher ...
-
bioRxiv - Immunology 2023Quote: ... Then 3 μl of the mixture was applied to a Quantifoil-Au-2/1-3C grid (Quantifoil) pretreated by glow-discharging at 20 mA for 1 min ...
-
bioRxiv - Microbiology 2023Quote: ... The samples were applied to a Quantifoil R2/2 Cu 300 mesh grid (Quantifoil Micro Tools GmbH), which had been freshly glow-discharged for 60 s at 10 mA using PIB-10 (Vacuum Device) ...
-
bioRxiv - Cell Biology 2024Quote: EM support grids (Au grids 200 mesh, carbon or SiO2 foil, R2/2 or R1/4, Quantifoil) were glow discharged with a Pelco easiGlow for 90 sec at 15 mA ...
-
bioRxiv - Biochemistry 2021Quote: ... 3.5 μl of the freshly purified sample from the peak fraction in DDM at ~2.0 mg/ml for the B.1.1.7 protein or ~1.5 mg/ml for the B.1.351 protein was applied to a 1.2/1.3 Quantifoil grid (Quantifoil Micro Tools GmbH), which had been glow discharged with a PELCO easiGlow™ Glow Discharge Cleaning system (Ted Pella ...
-
bioRxiv - Biophysics 2021Quote: 3μL of inactive or active CaSR protein was applied to glow-discharged holey carbon 300 mesh grids (Quantifoil Au R12/1.3, Quantifoil MicroTools), respectively ...
-
bioRxiv - Microbiology 2022Quote: ... the purified full-length BA.2 spike protein at 4.6 mg/ml in DDM was applied to a 1.2/1.3 Quantifoil gold grid (Quantifoil Micro Tools GmbH), which had been glow discharged with a PELCO easiGlow™ Glow Discharge Cleaning system (Ted Pella ...
-
bioRxiv - Evolutionary Biology 2022Quote: ... The proteins were incubated at 37°C and 200 rpms for 10 minutes on a microplate shaker (BioShake iQ; Quantifoil Instruments ...
-
bioRxiv - Biochemistry 2023Quote: ... 3 μl of protein at a concentration of approximately 10 mg ml−1 were loaded onto glow-discharged holey carbon grids (Quantifoil Au 300 mesh R1.2/1.3 or Quantifoil Cu/Rh 300 mesh R1.2/1.3) ...
-
bioRxiv - Biophysics 2023Quote: 3.5 µL of protein or lipid solution was applied onto a freshly glow-discharged carbon-coated copper mesh grid (Quantifoil). After 1 min ...
-
bioRxiv - Biochemistry 2023Quote: ... 3.6 µl of purified protein were applied onto glow- discharged holey carbon-coated grids (Quantifoil R1.2/1.3 Au 300 mesh) and blotted for 3.5 s with a blot force of 0 at 100% humidity and 4 °C before being frozen in liquid ethane using a Vitrobot Mark IV (Thermo Fisher Scientific) ...
-
bioRxiv - Biochemistry 2024Quote: ... Vitrified specimen was prepared by applying 3 μl of protein complexes onto a glow-discharged 300 mesh gold holey carbon Quantifoil R 1.2/1.3 grid (Quantifoil Micro Tools) and frozen in liquid ethane cooled by liquid nitrogen inside a Vitrobot Mark IV (FEI) ...
-
bioRxiv - Biochemistry 2020Quote: ... and 2 µL sample was applied to glow-discharged gold holey carbon 1.2/1.3 300-mesh grids (Quantifoil) coated in-house with graphene oxide55-57 ...
-
bioRxiv - Biochemistry 2021Quote: ... A volume of 2.5 μL of each sample was applied on glow-discharged UltrAuFoil Au300 Rl.2/1.3 grids (Quantifoil), and excess liquid was removed by blotting for 3 s (blot force 5 ...
-
bioRxiv - Biochemistry 2022Quote: ... 2 μl retromer at a concentration between 80-100 μg/ml was applied to freshly glow discharged CF-2/2-2C C-Flat grids (Protochips, Morrisville, NC) or Quantifoil R 1.2/1.3 300 mesh copper grids (Quantifoil Micro Tools GmbH ...
-
bioRxiv - Plant Biology 2022Quote: ... 2 μL of sample solution was applied onto a holey carbon grid (Quantifoil R2/1, Cu 300 mesh) covered with a thin amorphous carbon film ...
-
bioRxiv - Microbiology 2022Quote: ... 3.5 μL of cell suspension was applied on glow-discharged copper or gold EM grids (R2/2, Quantifoil) and automatically back-blotted (Weiss et al 2017 ...
-
bioRxiv - Molecular Biology 2021Quote: ... 3 μl of the resultant mixture was applied to glow-discharged (EasiGlow Pelco) R2/2 Quantifoil grids (Quantifoil). Excess sample was blotted away with a FEI Vitrobot (IV ...
-
bioRxiv - Biochemistry 2019Quote: ... 0.05% Tween-20 were applied on a glow-discharged holey carbon grid (Quantifoil, QF 2/1, 300 mesh). Subsequently ...
-
bioRxiv - Molecular Biology 2019Quote: ... 3 μl of the sample at 2 mg/ml were applied to 300 mesh UltrAuFoil Holey Gold Films R1.2/1.3 (Quantifoil) that had been previously plasma cleaned in a 75% argon / 25% oxygen atmosphere at 15 Watts for 6 seconds using a Solarus plasma cleaner (Gatan ...
-
bioRxiv - Evolutionary Biology 2021Quote: Molybdenum R1.2/1.3 and R2/2 200-mesh grids with a holey carbon support film (Quantifoil, Jena, DE) were glow discharged for 40 s under high vacuum shortly before sample application ...
-
bioRxiv - Biochemistry 2021Quote: ... 2 uL of crystal slurry was applied to each side of a glow-discharged holey carbon grid (Quantifoil, R 2/1 200 mesh Cu ...
-
bioRxiv - Biochemistry 2021Quote: ... 2 uL of crystal slurry was applied to each side of a glow-discharged holey carbon grid (Quantifoil, R 1/4 300 mesh Cu ...
-
bioRxiv - Biophysics 2020Quote: 3 µl of the toroid suspension were deposited onto a glow-discharged holey carbon grid (Quantifoil R2/2), blotted with a filter paper for 4 seconds ...
-
bioRxiv - Cell Biology 2020Quote: ... K735 apo and K772-ANP datasets were collected on untreated carbon/copper grids (Quantifoil R2/2 300 mesh). The grids used for the other 15 datasets were gold grids (UltrAuFoil R2/2 200 mesh) ...
-
bioRxiv - Biochemistry 2022Quote: ... were prepared by applying 3 μL of freshly prepared STC (1:2 dilution) to UltrAuFoil 300 mesh R1.2/1.3 holey grids (Quantifoil), glow-discharged for 60 s at 10 mA (Leica EM ACE200) ...
-
bioRxiv - Microbiology 2022Quote: Phage particles were negatively stained for 20 s with 2 % uranyl acetate on carbon-coated copper grids (Quantifoil) and observed at 100 kV on a Hitachi HT 7700 equipped with an AMT XR81B Peltier cooled CCD camera (8M pixel ...
-
bioRxiv - Microbiology 2023Quote: ... Phage particles were negatively stained for 20 seconds with 2% uranyl acetate on carbon-coated copper grids (Quantifoil) and observed at 100 kV on a Hitachi HT 7700 equipped with an AMT XR81B Peltier cooled CCD camera (8M pixel ...
-
bioRxiv - Microbiology 2022Quote: ... the amoebae (5×105 per well) were seeded onto EM gold finder grids (Au NH2 R2/2, Quantifoil) and incubated for 1 h ...
-
bioRxiv - Cell Biology 2022Quote: ... Cells were then seeded onto gold grids (either ‘UltrAuFoil’ 200 Au mesh, R2/2 gold film, or Quantifoil 300 Au mesh ...
-
bioRxiv - Molecular Biology 2023Quote: ... 4 μl of KMN complex at 0.3 mg/ml supplemented with 0.003% Triton were applied to glow-discharged UltrAuFoil R2/2 grids (Quantifoil). Excess liquid was removed by blotting (3.5 s at blot force −3) ...
-
bioRxiv - Plant Biology 2023Quote: ... H4 NCPs were applied to Quantifoil R2/1 200-mesh grids coated with 2 nm of carbon (Quantifoil). H4.VS were applied to unsupported Quantifoil R2/1 200-mesh grids (Quantifoil) ...
-
bioRxiv - Biochemistry 2023Quote: ... Differentiated U937 cells became adhesive and were seeded onto gold London Finder grids (Au H2 R2/2, Quantifoil) coated with vitronectin (25 µg/mL in 1xPBS ...
-
bioRxiv - Microbiology 2021Quote: ... Aliquots (4 μL) of the protein complex were placed on glow-discharged holey carbon grids (Quantifoil Au R1.2/1.3, 300 mesh). The grids were blotted and flash-frozen in liquid ethane cooled by liquid nitrogen with a Vitrobot apparatus (Mark IV ...
-
bioRxiv - Evolutionary Biology 2022Quote: ... The proteins were incubated at 37°C and 200 rpms for 10 minutes on a microplate shaker (Quantifoil Instruments, Jena, Germany). Next ...
-
bioRxiv - Molecular Biology 2022Quote: ... 4 μL of protein samples were immediately applied to discharged 300-mesh Au R1.2/1.3 grids (Quantifoil, Micro Tools GmbH, Germany). Grids were blotted for 4 s and plunged into liquid ethane using an FEI Mark IV Vitrobot operated at 8°C and 100% humidity ...
-
bioRxiv - Biophysics 2022Quote: A 3 µl aliquot of freshly concentrated or thawed protein at ∼1 mg/ml was deposited on an UltraAuFoil 300 mesh R 0.6/1 grid (Quantifoil Inc., UK) at 4 °C and 100% humidity in a Vitrobot Mark IV robot (Thermo Fisher) ...
-
bioRxiv - Biochemistry 2023Quote: 4 µL of protein solution (total protein concentration = 1 mg/mL) were applied to freshly glow-discharged QUANTIFOIL® R2/1 300 mesh grids (Quantifoil Micro Tools GmbH ...
-
bioRxiv - Biophysics 2023Quote: ... 3.5 μl of concentrated purified protein was applied to glow-discharged copper holey carbon grids (Quantifoil R 1.2/1.3, 300 mesh). In all cases ...
-
bioRxiv - Molecular Biology 2023Quote: ... Aliquots of 3 μL of samples at 0.75 mg/ml or 1.5 mg/ml protein concentration were placed on 300-mesh Cu holey carbon grids (Quantifoil, R1.2/1.3) after glow-discharge (PELCO easiGlow™ ...
-
bioRxiv - Cell Biology 2019Quote: ... cells were grown on 200 mesh gold R2/2 London Finder Quantifoil grids (Quantifoil Micro Tools GmbH, Jena, Germany) added to the bottom of MatTek dishes ...
-
bioRxiv - Cell Biology 2020Quote: ... HeLa cells were grown for 24 h on holey carbon-covered gold EM grids (200 mesh, R2/2, Quantifoil), fed with oleic acid and induced with doxycycline for Fsp27-EGFP expression for an unrelated project ...
-
bioRxiv - Microbiology 2022Quote: ... 3 μl aliquots of the mixture was applied to R2/2 200 mesh copper Quantiofoil grids (Quantifoil Micro Tools) that were freshly glow discharged ...
-
bioRxiv - Biochemistry 2019Quote: ... 3 μl were applied onto freshly glow-discharged Quantifoil Cu/Rh R2/2 holey carbon 200 mesh grids (Quantifoil). The grids were blotted for 4 seconds with a blotting force of −15 ...