Labshake search
Citations for Quantifoil Micro Tools :
101 - 150 of 488 citations for 7 methoxy 4 4 dimethylisochroman 1 3 dione since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biochemistry 2023Quote: 4 μL of Fcα–J–FcRL4 (0.3 mg/mL) were applied to glow-discharged holy-carbon gold grids (Quantifoil, R1.2/1.3, 300 mesh) or Ni-Ti grids (CryoMatrix ...
-
bioRxiv - Molecular Biology 2021Quote: ... 4 μl of protein sample (about 0.73 mg/ml) was applied onto a glow-discharged holey carbon grid (Quantifoil Au, R2/2, 300 mesh). After blotting for 3 s ...
-
bioRxiv - Molecular Biology 2021Quote: ... 4 μl of protein sample (about 1.5 mg/ml) was applied onto a glow-discharged holey carbon grid (Quantifoil Au, R1.2/1.3, 300 mesh). At a temperature of 4°C and under a humidity of 100% ...
-
bioRxiv - Microbiology 2020Quote: ... 3.5 μl of the freshly prepared mixture of the soluble S trimer and monomeric ACE2 (1:3 molar ratio) at ~1 mg/ml was applied to a 1.2/1.3 Quantifoil grid (Quantifoil Micro Tools GmbH, Germany), which had been glow discharged with a PELCO easiGlow™ Glow Discharge Cleaning system (Ted Pella ...
-
bioRxiv - Biophysics 2019Quote: ... 3.5 μl aliquots of the recombinant human TIM22 complex (7 mg ml-1) were dropped onto glow discharged holey carbon grids (Quantifoil Au R1.2/1.3, 300 mesh), blotted with a Vitrobot Mark IV (ThemoFisher Scientific ...
-
bioRxiv - Biophysics 2019Quote: An aliquot of 4 μl of 6 μM Ac-E46K α-syn fibril solution was applied to a glow-discharged holey carbon grid (Quantifoil R1.2/1.3, 300 mesh), blotted for 6.5 s ...
-
bioRxiv - Molecular Biology 2021Quote: ... 3.5 μL was applied to a glow-discharged Quantifoil copper grid with 2 nm continuous carbon support over holes (Quantifoil R 2/4 400 mesh), blotted ...
-
bioRxiv - Microbiology 2020Quote: ... A small volume (4 µL) of cells was then transferred onto freshly glow‐discharged copper R2/2 200 Quantifoil holey carbon grids (Quantifoil Micro Tools GmbH, Jena, Germany). Grids were then blotted and plunge‐frozen in a liquid ethane/propane mixture 31 using an FEI Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Biophysics 2020Quote: ... An aliquot of 4 μl pY39 α-syn fibril solution was applied to a glow-discharged carbon electron microscope grid (Quantifoil R1.2/1.3, 300 mesh). After 10 s of incubation ...
-
bioRxiv - Molecular Biology 2021Quote: The purified GIP1-42–GIPR–Gs–Nb35 complex at a concentration of 6-7 mg/mL was mixed with 100 μM GIP1-42 at 4 C and applied to glow-discharged holey carbon grids (Quantifoil R1.2/1.3, Au 300 mesh) that were subsequently vitrified by plunging into liquid ethane using a Vitrobot Mark IV (ThermoFisher Scientific) ...
-
bioRxiv - Molecular Biology 2021Quote: The purified tirzepatide–GIPR–Gs–Nb35 complex at a concentration of 18-20 mg/mL was mixed with 100 μM tirzepatide at 4°C and applied to glow-discharged holey carbon grids (Quantifoil R1.2/1.3, Au 300 mesh) that were subsequently vitrified by plunging into liquid ethane using a Vitrobot Mark IV (ThermoFisher Scientific) ...
-
bioRxiv - Molecular Biology 2021Quote: The purified non-acylated tirzepatide–GIPR–mini-Gs–Nb35 complex at a concentration of 14-16 mg/mL was mixed with 100 μM non-acylated tirzepatide at 4°C and applied to glow-discharged holey carbon grids (Quantifoil R1.2/1.3, Au 300 mesh) that were subsequently vitrified by plunging into liquid ethane using a Vitrobot Mark IV (ThermoFisher Scientific) ...
-
bioRxiv - Molecular Biology 2021Quote: The purified peptide 20–GIPR–Gs–Nb35 complex at a concentration of 5-6 mg/mL was mixed with 100 μM peptide 20 at 4°C and applied to glow-discharged holey carbon grids (Quantifoil R1.2/1.3, Au 300 mesh) that were subsequently vitrified by plunging into liquid ethane using a Vitrobot Mark IV (ThermoFisher Scientific) ...
-
bioRxiv - Molecular Biology 2021Quote: The purified peptide 20–GCGR–Gs–Nb35 complex at a concentration of 12-14 mg/mL was mixed with 100 μM peptide 20 at 4°C and applied to glow-discharged holey carbon grids (Quantifoil R1.2/1.3, Au 300 mesh) that were subsequently vitrified by plunging into liquid ethane using a Vitrobot Mark IV (ThermoFisher Scientific) ...
-
bioRxiv - Biochemistry 2023Quote: ... Four microliters of purified Cx36 proteins (4-6 mg/ml) were applied onto a negatively glow-discharged holey carbon grid (Quantifoil R1.2/1.3 Cu 300 mesh). For samples involving Cx36-WT ...
-
bioRxiv - Immunology 2023Quote: ... Then 3 μl of the mixture was applied to a Quantifoil-Au-2/1-3C grid (Quantifoil) pretreated by glow-discharging at 20 mA for 1 min ...
-
bioRxiv - Biochemistry 2023Quote: ... by applying 3 μL of it to plasma-cleaned 0.6/1 μm holey gold UltrAuFoil grids (Quantifoil). Following a 30 s incubation ...
-
bioRxiv - Biophysics 2020Quote: ... The WT and Y222F MTs were applied to lacey carbon grids (Agar Scientific AGS166-4 400 mesh copper grids) and holey carbon grids (Quantifoil R1.2/1.3 300 mesh copper grids) immediately after application of glow discharge to the grids ...
-
bioRxiv - Biochemistry 2022Quote: ... 3 μl of sample were applied onto a freshly glow-discharged copper R2/1 300 mesh grid (Quantifoil), blotted for 8 s on both sides with blotting force −15 and plunge-frozen in liquid ethane.
-
bioRxiv - Biochemistry 2022Quote: ... 3 μl of sample were applied onto a freshly glow-discharged copper R2/1 300 mesh grid (Quantifoil), blotted for 8 s on both sides with blotting force −15 and plunge-frozen in liquid ethane.
-
bioRxiv - Molecular Biology 2022Quote: ... 3 μl of protein sample was applied to holey carbon grids (Quantifoil, R 0.6/1 Cu 200 mesh) which were H2/O2 glow-discharged for 30 s ...
-
bioRxiv - Biochemistry 2022Quote: ... 3 μl of purified PP2A-PME-1 complex was applied onto a glow-discharged holey carbon grid (Quantifoil 300 mesh R 1.2/1/3 with ultrathin carbon ...
-
bioRxiv - Immunology 2021Quote: ... Then 3 μl of the protein mixture was applied to a Quantifoil-Cu-2/1-3C grid (Quantifoil) pretreated by glow-discharging at 15 mA for 1 min ...
-
Mechanism of actin-dependent activation of nucleotidyl cyclase toxins from bacterial human pathogensbioRxiv - Biochemistry 2021Quote: ... 3 μl of sample were applied onto a freshly glow-discharged copper R2/1 300 mesh grid (Quantifoil), blotted for 8 s on both sides with blotting force −20 and plunge-frozen in liquid ethane.
-
bioRxiv - Biochemistry 2022Quote: ... were prepared by applying 3 μL of freshly prepared STC (1:2 dilution) to UltrAuFoil 300 mesh R1.2/1.3 holey grids (Quantifoil), glow-discharged for 60 s at 10 mA (Leica EM ACE200) ...
-
bioRxiv - Molecular Biology 2022Quote: ... aliquots of 3 μl were applied to glow discharged grids (R2/1 or R1.2/1.3, Au 300, Quantifoil), blotted for 2 s and immediately plunge-frozen in liquid ethane using an FEI Vitrobot IV at 4°C and 100 % humidity ...
-
bioRxiv - Physiology 2023Quote: ... Sample solution (~ 3 μl) was applied on freshly glow discharge TEM grids (Quantifoil R2/1, Cu, mesh 200) and plunge-frozen in liquid ethane using Vitrobot Mark IV (Thermo Fisher Scientific) ...
-
bioRxiv - Biophysics 2023Quote: ... Micropatterns covered an area of 8 × 8 squares around the center of the cryo-TEM grids (Quantifoil R1/4 or R1/20, Au 200 mesh, SiO2 film) as previously described31 ...
-
bioRxiv - Molecular Biology 2020Quote: ... at 13 °C and 100% humidity: 3 μl of sample were applied onto a freshly glow-discharged copper R2/1 300 mesh grid (Quantifoil), blotted for 8 s on both sides with blotting force −20 and plunge-frozen in liquid ethane.
-
bioRxiv - Biochemistry 2020Quote: ... A volume of 3 μL of the sample was applied to a glow-discharged grid (Quantifoil R2/1 300 mesh) at 25 °C and 90 % humidity ...
-
bioRxiv - Cell Biology 2021Quote: ... 3 µl of the samples at 1 µg/µl was applied to UltrAUfoil R1.2/1.3 grids (Quantifoil Micro Tools GmbH). Grids were glow-discharged for 30 sec at 15 mA prior to sample application (PELCO easiGlow™ ...
-
bioRxiv - Biochemistry 2022Quote: 2.8 µl of F-actin sample (3 – 16 µM) was pipetted onto a glow-discharged R2/1 Cu 300 mesh holey-carbon grid (Quantifoil). After incubating for 1 – 2 seconds ...
-
bioRxiv - Cell Biology 2023Quote: ... An aliquot of 3 ul cell suspension was applied to the glow-discharged holey carbon-coated copper (R 2/1, 200 mesh) (Quantifoil) and blotted for 9 seconds by Leica GP2 (Leica Microsystems) ...
-
bioRxiv - Biophysics 2020Quote: ... 2.5 μl samples of GDN-purified proteins at a concentration of 1.5-3 mg ml−1 were applied to glow-discharged holey carbon grids (Quantifoil R1.2/1.3 or R0.6/1 Au 200 mesh). Excess liquid was removed in a controlled environment (4°C and 100% relative humidity ...
-
bioRxiv - Biophysics 2022Quote: UltraAUfoil R1.2/3 (Quantifoil Micro Tools GmbH) grids were glow-discharged on both sides for 30 s at 15 mA using a Pelco Easiglow ...
-
bioRxiv - Molecular Biology 2019Quote: ... Cryo-EM grids were prepared by application of 3.5 µl of the sample containing purified Ccr4-Not:ribosome complexes onto R3/3 copper grids with 3 nm continuous carbon support (Quantifoil) and vitrification in liquid ethane using a Vitrobot Mark IV (Thermo Fisher) ...
-
bioRxiv - Microbiology 2023Quote: ... 3 μL of 3 mg/mL of protein was added to glow discharged UltrAuFoil holey gold grid (Quantifoil GmbH) using a Vitrobot Mark IV (Thermofisher ...
-
bioRxiv - Biophysics 2024Quote: Approximately 3□μL of the sample solution were put on newly glow-discharged TEM grids (Quantifoil R2/1, Cu, mesh 200) and plunge-frozen in liquid ethane using the Vitrobot Mark IV (Thermo Fisher Scientific) ...
-
bioRxiv - Biophysics 2023Quote: ... 3 μl of medium containing one isolated muscle fibre was placed on the glow-discharged grid (Quantifoil R2/1 Au 200 mesh). After incubation for 60 seconds at 37 °C ...
-
bioRxiv - Microbiology 2020Quote: ... 3 μL of the sample was applied to a glow-discharged R2/1 300 mesh holey carbon copper grid (Quantifoil Micro Tools GmbH) and plunge-frozen in liquid ethane using a Vitrobot Mark IV (FEI ...
-
bioRxiv - Microbiology 2020Quote: ... 3 μL of diluted sample was applied to a glow-discharged (R2/1 300 mesh holey carbon copper grid (Quantifoil Micro Tools GmbH) and plunge-frozen in liquid ethane using a Vitrobot Mark IV (FEI ...
-
bioRxiv - Immunology 2022Quote: ... detergent at a final concentration of 0.005 mM was added to each sample and 3 µl of that solution was immediately loaded onto plasma-cleaned QuantiFoil R 2/1 (400-mesh; Quantifoil Micro Tools GmbH) and UltrAuFoil R 1.2/1.3 grids (300-mesh ...
-
bioRxiv - Immunology 2020Quote: ... and 3 µl was immediately loaded onto plasma cleaned Quantifoil R 2/1 holey carbon copper gri (Cu, 400-mesh, Quantifoil Micro Tools GmbH). Blotted grids were plunge-frozen into nitrogen-cooled liquid ethane.
-
bioRxiv - Molecular Biology 2022Quote: ... 2–3 μL of sample solution was applied to a holey carbon grid (Quantifoil R2/1, Mo 300 mesh; Quantifoil Micro Tools GmbH) covered with a thin amorphous carbon film at 4 °C with 100% humidity ...
-
bioRxiv - Molecular Biology 2022Quote: ... 3 μL of sample (10 μM EGFP in PBS) was deposited onto glow-discharged grids (Electron Microscopy Science and Quantifoil – see Table 1), prior to blotting the grids from the sample-side for 3 seconds.
-
bioRxiv - Microbiology 2023Quote: ... This mixture was applied to the front (3.7 µL) and to the back (1.3 µL) of carbon-coated copper grids (R2/2, Cu 200 mesh; Quantifoil) previously glow-discharged (2 mA ...
-
bioRxiv - Biochemistry 2022Quote: KRASGTPase/BRAFWT/MEK1SASA/14-3-3 complex in SEC buffer was applied to glow-discharged holey carbon grids (Quantifoil R1.2/1.3, 400 mesh) and vitrified using a Leica EM GP ...
-
bioRxiv - Microbiology 2024Quote: ... Sample volumes of 3.5 µl (8 OD260 per ml) were applied to grids (Quantifoil, Cu, 300 mesh, R3/3 with 3 nm carbon) which had been freshly glow-discharged using a GloQube (Quorum Technologies ...
-
bioRxiv - Biophysics 2021Quote: ... A suspension containing a mixture of 10 nm protein A coated colloidal gold (Aurion) and Ebola VLPs was applied with a volume of 3 µl on a glow discharged EM grid (Quantifoil, 200 Mesh, R2/1). The grid was blotted using No.1 Whatman paper for 3 sec from the back-side in a chamber with controlled humidity set to 70% and the temperature set to 24°C.
-
bioRxiv - Biophysics 2022Quote: ... an aliquot of 3 μL of sample was applied onto a glow-discharged holey carbon-coated copper grid (300 mesh, QUANTIFOIL® R 2/1) or holey gold grid (300 mesh ...