Labshake search
Citations for Quantifoil Micro Tools :
301 - 350 of 730 citations for 7 Chloro 1 3 dihydro 5 phenyl 2H 1 4 benzodiazepin 2 thione since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Cell Biology 2023Quote: ... Dissected tissues were placed on 200 mesh Molybdenum R2/1 EM grids (Quantifoil) immediately after dissection ...
-
bioRxiv - Plant Biology 2023Quote: ... H4.VS were applied to unsupported Quantifoil R2/1 200-mesh grids (Quantifoil). Grids were glow-discharged for 20 s in the presence of air using a current of 20 mA ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: Quantifoil grids (UltraAuFoil R 0.6/1, Au 300 mesh, Quantifoil MicroTools, Jena, Germany) were treated by plasma cleaning (Harrick Plasma ...
-
bioRxiv - Biochemistry 2024Quote: ... The sample was applied to Holey carbon grids (3.5/1, 400 mesh, Quantifoil) at 4 °C ...
-
bioRxiv - Biophysics 2020Quote: Purified GABAAR was incubated with ~1 μM Megabody-2524 and 3.5 μl sample was applied to glow discharged 300 mesh 1.2/1.3 and 2/2 UltraAuFoil gold grids (Quantifoil) for 30 s then blotted for 5.5 s prior to plunge-freezing with liquid ethane cooled by liquid nitrogen ...
-
bioRxiv - Bioengineering 2022Quote: ... Holey carbon Quantifoil grids (2 µm diameter with an interspace of 2 µm, Quantifoil Micro Tools GmbH, Germany) were prepared by glow discharge (easyGlow® System ...
-
bioRxiv - Biophysics 2021Quote: Gold EM grids with R1/4 holey SiO2 film (Quantifoil) were glow-discharged in a EasiGlow (Pelco ...
-
bioRxiv - Cell Biology 2019Quote: ... R1/4 or R1/20 (Quantifoil Micro Tools, Jena, Germany) were employed in this study ...
-
bioRxiv - Biophysics 2023Quote: 200 mesh Au grids with R1/4 SiO2 foil (Quantifoil) were glow-discharged for 90 sec at 0.38 mBar and 15 mA using a Pelco easiGlow device ...
-
bioRxiv - Microbiology 2022Quote: ... using R2/2 200 mesh grids (Quantifoil) and imaged using a Talos 120 kV cryo-transmission electron microscope.
-
bioRxiv - Microbiology 2023Quote: R2/2 Cu 200 mesh grids (Quantifoil) were glow-discharged for 40 s at 2.7 mA ...
-
bioRxiv - Biochemistry 2023Quote: UltrAuFoil R2/2 Au200 mesh grids (Quantifoil) were glow discharged for 1 min on both sides at 25 mA using a Pelco easiGlow unit (Ted Pella ...
-
bioRxiv - Biochemistry 2023Quote: UltrAuFoil R2/2 Au300 mesh grids (Quantifoil) were glow discharged for 30 seconds on each side at 25 mA using a Pelco easiGlow unit (Ted Pella ...
-
bioRxiv - Cell Biology 2022Quote: Cells were trypsinized and seeded onto 200 mesh gold holey carbon grids (R2/2-2 C, Quantifoil Micro Tools) placed in 3D printed grid holders (51 ...
-
bioRxiv - Bioengineering 2023Quote: ... a 200-mesh copper grid covered with a Quantifoil R 2/2 holey carbon film (Quantifoil Micro Tools GmbH) was surface plasma treated for 40 seconds using a Cressington 208 carbon coater ...
-
bioRxiv - Cell Biology 2023Quote: ... three microliters of EV sample were directly placed onto a glow–discharged 2/2 copper grid (Quantifoil, Jena, Germany). The excess sample was removed with 595 filter paper (Schleicher & Schuell ...
-
bioRxiv - Cell Biology 2023Quote: ... Two μl of the diluted complex were applied to freshly glow-discharged R 2/2 holey carbon grids (Quantifoil), which were blotted with a force of 6 for 5 seconds and immediately vitrified by plunge-freezing in liquid ethane using a Vitrobot Mark IV (ThermoFisher ...
-
bioRxiv - Biophysics 2020Quote: ... then positioned on a holey carbon TEM grid (Quantifoil R2/1, Cu, 200-mesh) pre-clipped into an Autogrid assembly (Thermo Fisher Scientific ...
-
bioRxiv - Molecular Biology 2021Quote: ... applied to glow-discharged holey carbon grids (R2/1, 200 mesh, Au, Quantifoil, Germany), and the NE was spread onto the grid by fine glass needles ...
-
bioRxiv - Cell Biology 2020Quote: ... reinhardtii cells were deposited onto 200-mesh copper EM (R2/1, Quantifoil Micro Tools) and vitrified using a Vitrobot Mark 4 (FEI Thermo Fisher Scientific) ...
-
Mechanism of actin-dependent activation of nucleotidyl cyclase toxins from bacterial human pathogensbioRxiv - Biochemistry 2021Quote: ... were applied onto a freshly glow-discharged copper R2/1 300 mesh grid (Quantifoil), blotted for 3 s on both sides with blotting force −3 and plunge-frozen in liquid ethane using the Vitrobot Mark IV system (Thermo Fisher Scientific ...
-
bioRxiv - Molecular Biology 2021Quote: ... applied to glow-discharged holey carbon grids (R2/1, 200 mesh, Au, Quantifoil, Germany), and the NE was spread onto the grid by fine glass needles ...
-
bioRxiv - Pathology 2023Quote: ... bombycis spores (1×105 spores/mL) were placed on nickel grids (Quantifoil, Beijing, China) for 15 min and germinated in 0.1 M KOH for 30 min at 30°C ...
-
bioRxiv - Molecular Biology 2023Quote: ... UltrAuFoil R1.2/1.3 or R0.6/1 300 mesh gold grids (Quantifoil Micro Tools GmbH) were glow discharged on both sides for 1.5 mins on a PELCO easiGlow glow discharge unit (20 mA ...
-
bioRxiv - Biophysics 2024Quote: Plunge freezing of cells was performed on R2/1 SiO2 copper 200 mesh (Quantifoil) grids ...
-
bioRxiv - Biochemistry 2022Quote: Samples (3 μl) were applied onto a glow-discharged UltrAuFoil grid (Quantifoil GmbH) and were flash-frozen in liquid ethane using the Vitrobot mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Biochemistry 2024Quote: Samples (3 μl) were applied onto a glow-discharged UltrAuFoil grid (Quantifoil GmbH) and were flash frozen in liquid ethane using the Vitrobot mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Neuroscience 2022Quote: ... Gold Quantifoil grids (R1/4, Au 200 mesh, Quantifoil Micro Tools) were additionally coated with a 20-25 nm carbon layer (MED 020 ...
-
bioRxiv - Molecular Biology 2020Quote: Samples were diluted to a concentration of 60-65 nM for the Pol II-U1 snRNP complex and 2 μl was applied to each side of the R2/2 UltrAuFoil grids (Quantifoil) that had been glow-discharged for 100 s ...
-
bioRxiv - Microbiology 2020Quote: ... 105 fluorescence-stained cells were deposited on the surface of Au-G200F1 finder grids coated with holey carbon (R 2/2; Quantifoil) and functionalized with Poly-L-Lysine (Merck ...
-
bioRxiv - Biophysics 2021Quote: ... 3.5 μL of sample were applied to glow-discharged 2/2 Quantifoil holey carbon grids (Quantifoil Micro Tools GmbH, Germany) and plunged frozen in liquid ethane with a Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Cell Biology 2023Quote: ... 150 or 200 mesh gold holey carbon grids (R 2/2, #N1-C16nAu15-01 and #N1-C16nAu20-01, respectively) were purchased from Quantifoil Micro Tools and glow discharged for 2 min in an ELMO glow discharge unit (Agar Scientific ...
-
bioRxiv - Biochemistry 2022Quote: R2/2 holey carbon supported copper grids (Quantifoil) coated with a 2nm thin carbon layer were treated as described (A ...
-
bioRxiv - Biochemistry 2020Quote: ... QF AU-200 mesh R2/2 grids (Quantifoil) were glow-discharged and placed into a 6-well tissue culture plate well containing 2 mL of cell culture medium for at least 1 h before cell seeding ...
-
bioRxiv - Microbiology 2022Quote: ... gold finder grids (Au NH2 R2/2, Quantifoil) containing infected amoebae were vitrified by back-blotting (Teflon ...
-
bioRxiv - Biochemistry 2023Quote: ... UltrAufoil Au 200 mesh R2/2 grids (Quantifoil) EM grids were glow-discharged on each side for 90 s at 30 sccm ...
-
bioRxiv - Microbiology 2021Quote: ... before being vitrified on carbon-coated Au grids (R06/1, 200 mesh; Quantifoil, Jena, Germany).
-
bioRxiv - Cell Biology 2021Quote: For each glow-discharged copper grid (Quantifoil Cu 200 mesh, holy carbon film R2/1) 4 μl of the supernatant were applied ...
-
bioRxiv - Molecular Biology 2021Quote: ... Ribosome–EF-G complexes were applied to EM grids (Quantifoil 3.5/1 μm, Jena Bioscience) covered with pre-floated continuous carbon ...
-
Structure of the Human Signal Peptidase Complex Reveals the Determinants for Signal Peptide CleavagebioRxiv - Biochemistry 2020Quote: ... or Cu 200 Holey Carbon R2/1 grids (Quantifoil, for samples containing 1.5 mM FFosC). In both cases ...
-
bioRxiv - Biophysics 2019Quote: ... The best ice distribution and particle density was obtained with 0.6/1 UltrAuFoil grids (Quantifoil).
-
bioRxiv - Molecular Biology 2022Quote: ... The sample was applied onto freshly glow-discharged Au 300 mesh R0.6/1 grids (Quantifoil) in a Vitrobot Mark IV at 4°C ...
-
bioRxiv - Cell Biology 2023Quote: A volume of 4µl of cells was deposited on R2/1 Cu 200 grids (Quantifoil) that had been glow-discharged for 1 min at 0.19 mbar and 20 mA in a PELCO easiGlow device shortly before use ...
-
bioRxiv - Biophysics 2022Quote: ... 10 µl sample was applied onto a glow discharged copper grid coated with holey carbon (R 2/2; Quantifoil, Jena, Germany), and subsequently dipped onto 500 µl deionized H2O for 1 second to clear the sucrose ...
-
bioRxiv - Microbiology 2023Quote: CryoEM samples were prepared by applying 5 μL aliquots of purified PLE PLPs to R2/2 Quantifoil grids and R2/2 Quantifoil grids coated with 2nm ultrathin Carbon (QUANTIFOIL®) that had been glow discharged for 45 seconds in a Pelco Easiglow glow discharging unit ...
-
bioRxiv - Biochemistry 2024Quote: ... of the freshly eluted complex peak solution (4.0 mg/mL) was loaded onto glow-discharged holey carbon grids (Quantifoil 2/2). The procedures for blotting and plunge freezing the grids were the same as above ...
-
bioRxiv - Cell Biology 2020Quote: All samples were imaged on carbon coated 3 mm gold EM finder grids (Quantifoil). Bead test and calibration samples were made by adding 2 µl of 175 nm fluorescent bead solution(Thermo Fisher PS-Speck) ...
-
bioRxiv - Biophysics 2021Quote: ... before applying 4 µL of the solution to a glow-discharged (30s at 35 mA) copper R 2/2 200-mesh holey carbon grid (Quantifoil Micro Tools). The grids were blotted manually from the back side with Whatman filter paper #1 for 2-4 s ...
-
bioRxiv - Molecular Biology 2019Quote: ... Three microliters of polymerised sample were applied onto R 2/2 holey carbon support film on a 300-mesh copper EM sample grid (Quantifoil Micro Tools), which had been glow discharged immediately prior to use ...
-
bioRxiv - Cell Biology 2022Quote: ... Thin sections of 50μm were obtained using a vibratome and placed onto a glow discharged electron microscopy grid (UltrAuFoil, 200 Au mesh, 2/2 Au film (Quantifoil Micro Tools)) that had been pre-clipped into Autogrids (Thermo Fisher Scientific) ...