Labshake search
Citations for Quantifoil Micro Tools :
51 - 100 of 123 citations for 7 CHLORO 4 HYDROXY 8 METHYLQUINOLINE since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biophysics 2022Quote: ... 4 μL of the TnsBCTD-TnsC-TniQ sample was loaded on UltrAuFoil R1.2/1.3 gold grids (Quantifoil) and vitrified using the Mark IV Vitrobot (ThermoFisher ...
-
bioRxiv - Neuroscience 2022Quote: Primary cultured neurons were seeded onto holey gold EM grids (Quantifoil R 1/4 gold 200 mesh). The fiducial marker solution was prepared as for neocortical synaptosomes ...
-
bioRxiv - Biophysics 2023Quote: 4 μL purified protein was placed on the holy-carbon grids (Quantifoil Au R1.2/1.3, 300 mesh), which were glow-discharged for 30 s ...
-
bioRxiv - Biophysics 2023Quote: ... 4 µL fresh sample was applied on glow-discharged Cu holey carbon grids (Quantifoil R 1.2/1.3) and incubated for 1 min at room temperature ...
-
bioRxiv - Cell Biology 2024Quote: ... Quantifoil Holey SiO2 R 1/4 Au 200 mesh EM grids (Quantifoil Micro Tools #N1-s13nAi20-01) were glow discharged on both sides in a Pelco easyglow for 45 s at 0.37 mBar and 15 mA ...
-
bioRxiv - Cell Biology 2024Quote: EM support grids (Au grids 200 mesh, carbon or SiO2 foil, R2/2 or R1/4, Quantifoil) were glow discharged with a Pelco easiGlow for 90 sec at 15 mA ...
-
bioRxiv - Biochemistry 2021Quote: ... 3 microlitres of undiluted eluate and of eluate which was diluted 1:2 or 1:4 in buffer A200 were blotted onto holey carbon R 1.2/1.3 copper 300 mesh grids (Quantifoil) and vitrified in liquid ethane using a Vitrobot MarkIV device (Thermofisher) ...
-
bioRxiv - Biophysics 2019Quote: Samples for cryo-EM were prepared by applying 4 µl of purified TRPA1 to 1.2/1.3 holey carbon grids (Quantifoil) and blotting for 8-12 sec ...
-
bioRxiv - Biophysics 2021Quote: ... 4 µL of aldolase sample were applied on UltrAuFoil R1.2/1.3 300-mesh grids (Quantifoil Micro Tools GmbH) that had been freshly plasma cleaned for 6 seconds at 15 Watts (75% nitrogen/25% oxygen atmosphere ...
-
bioRxiv - Biophysics 2021Quote: ... 4 µL of apoferritin sample were applied on UltrAuFoil R1.2/1.3 300-mesh grids (Quantifoil Micro Tools GmbH) that had been freshly plasma cleaned for 7 seconds at 15 Watts (75% nitrogen/25% oxygen atmosphere ...
-
bioRxiv - Biophysics 2021Quote: The LlCsm RNP and RNP-target RNA samples at approximately 0.5 mg/ml were separately applied in 4 μL volume onto glow-discharged UltrAuFoil 300 mesh R1.2/1.3 grids (Quantifoil), blotted for 3 s at 88% humidity and flash-frozen in liquid ethane using FEI Vitrobot Mark IV ...
-
bioRxiv - Molecular Biology 2022Quote: ... for 15 min before 4 μL of sample was applied to a graphene oxide coated 1.2/1.3 UltrAuFoil grids (Quantifoil) at 4°C under 100% humidity86 ...
-
bioRxiv - Microbiology 2022Quote: ... Aliquots of 4 μL samples were applied to glow-discharged holey carbon girds (Cu, R1.2/1.3, 300 mesh, Quantifoil). The grids were blotted with force 2 for 3 seconds and plunged into liquid ethane using a Vitrobot (FEI Thermo Fisher) ...
-
bioRxiv - Molecular Biology 2024Quote: ... The peak fraction was then diluted with buffer N to 0.8 mg ml-1 and cryoEM grids prepared by applying 4 µl of the sample to glow-discharged Cu R1.2/1.3 300-mesh holey carbon grids (Quantifoil). Grids were prepared blotted at 8 °C and 90% humidity and plunged into liquid ethane using a Leica EM GP2.
-
bioRxiv - Biochemistry 2024Quote: ... 4 uL of the concentrated sample was applied to freshly glow-discharged R2/1 holey carbon grids (Quantifoil), blotted with blot force of 5 for 5 s using a Vitrobot Mark IV (Thermo Fisher ...
-
bioRxiv - Biochemistry 2020Quote: ... KBP was diluted to 0.3 mg/ml in KBP dilution buffer and 4 μl were applied to glow-discharged 1.2/1.3 AuFoil gold grids (Quantifoil®). For the third approach ...
-
bioRxiv - Molecular Biology 2019Quote: The concentration of the core BBSome as derived from chemical crosslinking was adjusted to 0.05-0.08 mg/ml and 4 μl of sample was immediately applied to a glow-discharged UltrAuFoil® R1.2/1.3 holey gold grid (Quantifoil). After two minutes incubation at 13 °C and 100% relative humidity (RH) ...
-
bioRxiv - Biophysics 2021Quote: ... 4 µl of this mixture was applied on a glow-discharged Quantifoil R2/2 grid (Quantifoil Micro Tools GmbH) and flash-frozen in liquid ethane using a Vitrobot Mark II device (FEI) ...
-
bioRxiv - Molecular Biology 2021Quote: Purified mtLSU or 55S mitoribosome samples (4 μL) were applied to freshly glow discharged R 3.5/1 holey carbon grids (Quantifoil) that were precoated with a 2-3 nm carbon layer using a Leica EM ACE600 coater ...
-
bioRxiv - Microbiology 2022Quote: ... A 4□μl volume of SsoCsm complex was applied to holey carbon grids (Quantifoil Cu R1.2/1.3, 300 mesh) covered by a graphene oxide layer (27) ...
-
bioRxiv - Microbiology 2024Quote: ... 4 μL of the cell mixture was applied three times onto glow-discharged copper EM grids (R2/2, Quantifoil), followed by plunge freezing into liquid ethane/propane ...
-
bioRxiv - Biophysics 2021Quote: ... Log phase cultures were centrifuged at 2000 g for 2 minutes to concentrate the cells 10 times and 4 μl was directly applied to a glow-discharged holey carbon R2/1 Cu 200 mesh grid (Quantifoil). Plunge-freezing was performed using a VitroBot Mark 4 (Thermo Fisher Scientific ...
-
bioRxiv - Biophysics 2022Quote: 3.5 μl of protein samples at 4-6 mg/ml were applied to glow-discharged QF R1.2/1.3 300 mesh gold grids (Quantifoil, Großlöbichau, Germany). Grids were blotted for 3 s at 4°C and 100% humidity and plunge-frozen into liquid ethane using FEI Mark IV Vitrobot (FEI ...
-
bioRxiv - Plant Biology 2022Quote: ... then 4 µl of the sample was applied to glow-discharged holey carbon grids (Quantifoil Cu R1.2/1.3, 300 mesh). The grid was blotted for 4s and then plunged into liquid ethane using a Vitrobot Mark IV (FEI ...
-
bioRxiv - Microbiology 2023Quote: ... trehalose solution to mitigate crystalline ice formation and 4 μL of this mixture immediately applied to a R2/1 Cu 200 grid (Quantifoil), which had been glow-discharged for 1 min at 0.19 mbar and 20 mA in a PELCO easiGlow device shortly before use ...
-
bioRxiv - Biochemistry 2023Quote: ... pristine graphene-coated R2/4 grids (Graphenea) were initially used for optimisation purposes but 2 nm formvar/amorphous carbon R2/2 grids (Quantifoil) were used for data collection ...
-
bioRxiv - Molecular Biology 2023Quote: 1.8 × 105 A549 or A549-IFITM3 cells were seeded on glow-discharged 200 mesh gold grids with a holey SiO2 film with R1/4 spacing (Quantifoil) placed in a 35 mm dish and cultured in 2 ml complete growth medium (DMEM-F12 ...
-
bioRxiv - Biophysics 2023Quote: ... 4 µL fresh sample (0.48 mg/mL) was applied on glow-discharged Au holey carbon grids (Quantifoil R 0.6/1) and the following operation were the same as describe above for preparing the sample of gMCM8/9 complex.
-
bioRxiv - Biochemistry 2023Quote: ... 4 μL of Fcμ–J–CD5L was applied to glow-discharged holy-carbon gold grids (Quantifoil, R1.2/1.3, 300 mesh), blotted with filter paper in 100% humidity at 4 °C ...
-
bioRxiv - Cell Biology 2024Quote: ... 4 μl of the cell suspension was applied onto a glow-discharged holey SiO2 grid (R1/4, Au, 200 mesh, Quantifoil) mounted on in the plunger chamber ...
-
bioRxiv - Microbiology 2021Quote: ... Aliquots (4 μL) of the protein complex were placed on glow-discharged holey carbon grids (Quantifoil Au R1.2/1.3, 300 mesh). The grids were blotted and flash-frozen in liquid ethane cooled by liquid nitrogen with a Vitrobot apparatus (Mark IV ...
-
bioRxiv - Biochemistry 2019Quote: ... 2 μL of crystal solution was deposited on each side of a glow-discharged holey carbon EM grid (Quantifoil 2/4), and the grid was processed with a Vitrobot Mark IV (Thermo Fisher ...
-
bioRxiv - Biophysics 2019Quote: 3.5 ul of sample of doublets (∼4 mg/ml) was applied to a glow-discharged holey carbon grid (Quantifoil R2/2), blotted and plunged into liquid ethane using Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Microbiology 2020Quote: Three μl of purified HKU1 HE (4 mg/ml) was dispensed on Quantifoil R1.2/1.3 200-mesh grids (Quantifoil Micro Tools GmbH) that had been freshly glow discharged for 30 seconds at 20 mA using GloQube Glow Discharge system (Quorum Technologies) ...
-
bioRxiv - Molecular Biology 2021Quote: ... cells in suspension (4 μl of ~1,000 cells per μl) were blotted onto R2/1 carbon-coated 200-mesh copper grids (Quantifoil Micro Tools) and plunge frozen in a liquid ethane/propane mixture ...
-
bioRxiv - Molecular Biology 2022Quote: ... 4 μL of protein samples were immediately applied to discharged 300-mesh Au R1.2/1.3 grids (Quantifoil, Micro Tools GmbH, Germany). Grids were blotted for 4 s and plunged into liquid ethane using an FEI Mark IV Vitrobot operated at 8°C and 100% humidity ...
-
bioRxiv - Molecular Biology 2022Quote: ... 4 μL of the cells were applied to a glow-discharged 200 mesh holey carbon grid copper grid (Quantifoil R1.2/3) and vitrified in a liquid ethane on a Vitrobot Mark IV (Thermo Scientific ...
-
bioRxiv - Cell Biology 2023Quote: ... 4 μl of the sample was applied to glow discharged holey carbon-coated 200 mesh copper EM grids (Quantifoil Micro Tools), vitrified as above at 4°C and 100 % humidity.
-
bioRxiv - Molecular Biology 2021Quote: ... bremelanotide– or THIQ–bound MC4R–Gs complexes at ∼ 4 mg/mL were applied onto glow-discharged holey carbon grids (Quantifoil R1.2/1.3). Excess samples were blotted away and the grids were vitrified by plunging into liquid ethane using a Vitrobot Mark IV (ThermoFischer Scientific).
-
bioRxiv - Biophysics 2019Quote: 3.5 μl of microtubule fraction sample (∼4 mg/ml) purified from WT Chlamydomonas was applied to glow-discharged holey carbon grids (Quantifoil R2/2), blotted and vitrified in liquid ethane using the Vitrobot Mark IV (FEI Company) ...
-
bioRxiv - Genomics 2020Quote: ... Vitrified specimens were prepared by adding 4 μl disome samples at the concentration of ~ 150 nM to a glow-discharged holey carbon grid (Quantifoil R1.2/1.3), which was covered with a freshly made thin carbon film ...
-
bioRxiv - Cell Biology 2020Quote: ... The MEFs were applied onto glow-discharged EM grids with a silicon-oxide support film (R1/4, Au mesh; Quantifoil, Jena, Germany). After incubation ...
-
Genome modularization reveals overlapped gene topology is necessary for efficient viral reproductionbioRxiv - Synthetic Biology 2020Quote: A 4 μL solution of co-isolated small particles were applied to glow-discharged copper grids (Quantifoil R2/2, Quantifoil Micro Tools), blotting for 3-seconds at 4 °C with 90% humidity and plunging into liquid ethane using a Lecia EM GP device (Leica Microsystems ...
-
Genome modularization reveals overlapped gene topology is necessary for efficient viral reproductionbioRxiv - Synthetic Biology 2020Quote: A 4 μL solution of co-isolated small particles were applied to glow-discharged copper grids (Quantifoil R2/2, Quantifoil Micro Tools), blotting for 3-seconds at 4 °C with 90% humidity and plunging into liquid ethane using a Lecia EM GP device (Leica Microsystems ...
-
bioRxiv - Molecular Biology 2019Quote: 4 µL of 0.06 mg/mL crosslinked complex were applied to glow-discharged holey carbon grids (Quantifoil, QF 1.2/1.3, 300 mesh) covered with a 2 nm carbon layer ...
-
bioRxiv - Molecular Biology 2020Quote: The grids were prepared by applying 4 µL of each complex at ∼70 nM to 400 mesh holey carbon Quantifoil 2/2 grids (Quantifoil Micro Tools). The grids were blotted for 1.5 sec at 4°C ...
-
bioRxiv - Cell Biology 2022Quote: The cryo-EM grid was prepared by applying 3 μl of the protein samples (4 – 6 mg/ml) to glow-discharged Quantifoil R1.2/1.3 300-mesh gold holey carbon grids (Quantifoil, Micro Tools GmbH, Germany). Grids were blotted for 4.0 seconds under 100% humidity at 4°C before being plunged into the liquid ethane using a Mark IV Vitrobot (FEI) ...
-
Mycobacteria form viable cell wall-deficient cells that are undetectable by conventional diagnosticsbioRxiv - Microbiology 2022Quote: ... of which 3-4 µL was applied on glow-discharged 200 mesh copper grids with an extra thick R2/2 carbon film (Quantifoil Micro Tools). Vitrification was performed using an automated Leica EM GP plunge-freezer ...
-
bioRxiv - Cell Biology 2023Quote: ... Four µL of the cells were subsequently deposited onto Quantifoil R2/4 200 mesh copper grids (Quantifoil Micro Tools GmbH, Jena, Germany), which were then manually blotted from the back with Whatman® Grade 1 filter paper for approximately 3 – 5 seconds ...
-
bioRxiv - Biophysics 2023Quote: ... 4 μl suspended cells were loaded onto the front side of glow-discharged holy-carbon copper grids (Quantifoil R1.2/1.3, 200 mesh), and 2 μl medium was subsequently added to the back side of the grids ...