Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Microbiology 2020Quote: QUANTIFOIL R2/1 200 mesh holey carbon Cu grids (Quantifoil Micro Tools) were glow discharged using PELCO easiGlow (Ted Pella) ...
-
bioRxiv - Microbiology 2021Quote: ... coated with a carbon mesh (R2/1, 200 mesh; Quantifoil, Jena, Germany).
-
bioRxiv - Microbiology 2021Quote: ... coated with a carbon mesh (R2/1, 200 mesh; Quantifoil, Jena, Germany). The grids were manually blotted for ~4-5 s from the reverse side and plunge frozen in liquid ethane by using an in-house plunger.
-
bioRxiv - Biochemistry 2021Quote: ... Cu R1.2/1.3 or R2/1 holey carbon grids (Quantifoil, Groslöbichau, Germany) were glow discharged at 25 mA for 45 seconds using an Emitech K950 apparatus (Quorum ...
-
bioRxiv - Microbiology 2021Quote: ... with the exception that Quantifoil Au R0.6/1 300 mesh grids (Quantifoil) were used ...
-
bioRxiv - Molecular Biology 2023Quote: Cells were cultured directly on gold grids (R2/1, carbon film, Quantifoil) after being glow-discharged using a Pelco GD system ...
-
bioRxiv - Biochemistry 2022Quote: ... holey carbon-coated copper grids (type R2/1 200 mesh from Quantifoil) are glow discharged using a PELCO easiGlow (15 mA ...
-
bioRxiv - Microbiology 2023Quote: ... Gold grids with SiO2 film (Quantifoil, Au 200 mesh, R 1/4) were glow- discharged and coated with 20 µg/ml fibronectin solution for 30 min ...
-
bioRxiv - Immunology 2024Quote: ... 3 µL aliquots were applied to UltrAuFoil gold R0.6/1 grids (Quantifoil) and subsequently blotted for 6 seconds at blot force 0 ...
-
bioRxiv - Microbiology 2024Quote: ... The mixture was deposited onto freshly glow-discharged grids (R2/1 Quantifoil) for 1 min ...
-
bioRxiv - Cell Biology 2023Quote: ... a 200-mesh gold grid with Silicon Dioxide R2/1 film (Quantifoil) was coated with Matrigel as reported in the protocol ...
-
bioRxiv - Biochemistry 2021Quote: ... A freshly glow-discharged holey-carbon grid (QF R2/1 300 mesh, Quantifoil) was mounted to a Vitrobot cryoplunger (Thermo Fisher) ...
-
bioRxiv - Biochemistry 2022Quote: ... holey support film type R2/1 on 200 mesh copper grid (Quantifoil, Germany) that was previously glow discharged under the following conditions ...
-
bioRxiv - Bioengineering 2022Quote: ... holey carbon grids (Ultrafoil 25 nM Au R 0.6/1 300 mesh; Quantifoil) were incubated with a thiol reactive ...
-
bioRxiv - Plant Biology 2023Quote: ... H4.VS were applied to unsupported Quantifoil R2/1 200-mesh grids (Quantifoil). Grids were glow-discharged for 20 s in the presence of air using a current of 20 mA ...
-
bioRxiv - Cell Biology 2023Quote: ... Dissected tissues were placed on 200 mesh Molybdenum R2/1 EM grids (Quantifoil) immediately after dissection ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: Quantifoil grids (UltraAuFoil R 0.6/1, Au 300 mesh, Quantifoil MicroTools, Jena, Germany) were treated by plasma cleaning (Harrick Plasma ...
-
bioRxiv - Biochemistry 2024Quote: ... The sample was applied to Holey carbon grids (3.5/1, 400 mesh, Quantifoil) at 4 °C ...
-
bioRxiv - Microbiology 2021Quote: ... 4-7 µl of cells were deposited on R2/1 Cu 200 grids (Quantifoil) that had been glow-discharged for 1 min at 0.19 mbar and 20 mA in a PELCO easiGlow device shortly before use ...
-
bioRxiv - Biochemistry 2022Quote: ... 3 μL of sample was applied to 200-mesh copper R2/1 grids (Quantifoil), which were glow-discharged twice using a Pelco EasyGlow instrument ...
-
bioRxiv - Biophysics 2020Quote: ... then positioned on a holey carbon TEM grid (Quantifoil R2/1, Cu, 200-mesh) pre-clipped into an Autogrid assembly (Thermo Fisher Scientific ...
-
bioRxiv - Molecular Biology 2021Quote: ... applied to glow-discharged holey carbon grids (R2/1, 200 mesh, Au, Quantifoil, Germany), and the NE was spread onto the grid by fine glass needles ...
-
bioRxiv - Cell Biology 2020Quote: ... reinhardtii cells were deposited onto 200-mesh copper EM (R2/1, Quantifoil Micro Tools) and vitrified using a Vitrobot Mark 4 (FEI Thermo Fisher Scientific) ...
-
Mechanism of actin-dependent activation of nucleotidyl cyclase toxins from bacterial human pathogensbioRxiv - Biochemistry 2021Quote: ... were applied onto a freshly glow-discharged copper R2/1 300 mesh grid (Quantifoil), blotted for 3 s on both sides with blotting force −3 and plunge-frozen in liquid ethane using the Vitrobot Mark IV system (Thermo Fisher Scientific ...
-
bioRxiv - Molecular Biology 2021Quote: ... applied to glow-discharged holey carbon grids (R2/1, 200 mesh, Au, Quantifoil, Germany), and the NE was spread onto the grid by fine glass needles ...
-
bioRxiv - Molecular Biology 2022Quote: ... 3 μl sample was applied to 1.2/1.3 or 0.6/1 UltrAuFoil grids (Quantifoil) (Russo and Passmore ...
-
bioRxiv - Pathology 2023Quote: ... bombycis spores (1×105 spores/mL) were placed on nickel grids (Quantifoil, Beijing, China) for 15 min and germinated in 0.1 M KOH for 30 min at 30°C ...
-
bioRxiv - Molecular Biology 2023Quote: ... UltrAuFoil R1.2/1.3 or R0.6/1 300 mesh gold grids (Quantifoil Micro Tools GmbH) were glow discharged on both sides for 1.5 mins on a PELCO easiGlow glow discharge unit (20 mA ...
-
bioRxiv - Biophysics 2023Quote: 3 μL of sample was applied on glow-discharged Au200 R2/1 grids (Quantifoil), and the excess liquid was removed by blotting for 4 s (blot force 3 ...
-
bioRxiv - Biophysics 2024Quote: Plunge freezing of cells was performed on R2/1 SiO2 copper 200 mesh (Quantifoil) grids ...
-
bioRxiv - Biophysics 2021Quote: ... 4 μl of cell suspension was applied to holey carbon R2/1 Cu grids (Quantifoil) and plunge-frozen on a Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Microbiology 2021Quote: ... before being vitrified on carbon-coated Au grids (R06/1, 200 mesh; Quantifoil, Jena, Germany).
-
bioRxiv - Cell Biology 2021Quote: For each glow-discharged copper grid (Quantifoil Cu 200 mesh, holy carbon film R2/1) 4 μl of the supernatant were applied ...
-
bioRxiv - Molecular Biology 2021Quote: ... Ribosome–EF-G complexes were applied to EM grids (Quantifoil 3.5/1 μm, Jena Bioscience) covered with pre-floated continuous carbon ...
-
Structure of the Human Signal Peptidase Complex Reveals the Determinants for Signal Peptide CleavagebioRxiv - Biochemistry 2020Quote: ... or Cu 200 Holey Carbon R2/1 grids (Quantifoil, for samples containing 1.5 mM FFosC). In both cases ...
-
bioRxiv - Microbiology 2019Quote: ... 4 μL of sample was applied to glow-discharged EM grids (R2/1 copper, Quantifoil), blotted twice from the back for 3.5 s and vitrified in liquid ethane–propane using a Vitrobot Mark IV (ThermoFisher) ...
-
bioRxiv - Biophysics 2019Quote: ... The best ice distribution and particle density was obtained with 0.6/1 UltrAuFoil grids (Quantifoil).
-
bioRxiv - Molecular Biology 2022Quote: ... The sample was applied onto freshly glow-discharged Au 300 mesh R0.6/1 grids (Quantifoil) in a Vitrobot Mark IV at 4°C ...
-
bioRxiv - Cell Biology 2023Quote: A volume of 4µl of cells was deposited on R2/1 Cu 200 grids (Quantifoil) that had been glow-discharged for 1 min at 0.19 mbar and 20 mA in a PELCO easiGlow device shortly before use ...
-
bioRxiv - Cell Biology 2024Quote: Quantifoil R2/1 or SiO2 R1/4 gold grids (both Quantifoil Mirco Tools GmbH, Germany) were briefly washed in chloroform and placed on drops of poly-D-lysine (100 µg/ml) ...
-
bioRxiv - Biophysics 2019Quote: ... We then used a glow-discharged Quantifoil EM grids (R2/1, Cu 300 mesh; QUANTIFOIL Company) to gently touch the powder for several times ...
-
bioRxiv - Molecular Biology 2021Quote: ... The sample-covered carbon was then adsorbed to an EM grid (Quantifoil R3.5/1, Jena Bioscience) and blotted for 9 s using a Vitrobot Mark IV (ThermoFisher ...
-
Mechanism of actin-dependent activation of nucleotidyl cyclase toxins from bacterial human pathogensbioRxiv - Biochemistry 2021Quote: ... the mixture was applied onto a freshly glow-discharged copper R2/1 300 mesh grid (Quantifoil), blotted for 3 s on both sides with blotting force −5 and plunge-frozen in liquid ethane using the Vitrobot Mark IV system (Thermo Fisher Scientific ...
-
bioRxiv - Microbiology 2024Quote: ... 3.5 μL of the culture were applied onto glow-discharged copper EM grids (R2/1, Quantifoil), automatically blotted and plunged into liquid ethane/propane (Tivol et al ...
-
bioRxiv - Microbiology 2021Quote: ... and 5 μl of the washed cells were introduced to Au grids (R2/1, 200 mesh; Quantifoil). The grids were fixed in 4% PFA (in TBS ...
-
bioRxiv - Biophysics 2022Quote: A volume of 4-7 µl of cells were deposited on R2/1 Cu 200 grids (Quantifoil) that had been glow-discharged for 1 min at 0.19 mbar and 20 mA in a PELCO easiGlow device shortly before use ...
-
bioRxiv - Biophysics 2019Quote: ... Cryo-EM grids (Quantifoil R2/1 Cu mesh 200-300 or Quantifoil R1.2/1.3 Cu mesh 300) were glow discharged with air plasma in a Cressington 208 carbon coater with glow discharge unit for 90 s (10 mA/0.1 mbar air pressure ...
-
bioRxiv - Biochemistry 2022Quote: ... Solutions were adjusted to OD600≈10 and applied to carbon-coated holey copper grids (Quantifoil R2/1). Grids were glow-discharged for 30 s in oxygen/argon atmosphere of a plasma cleaner (Gatan Solarus 950 ...
-
bioRxiv - Microbiology 2021Quote: ... 200-mesh copper grid with holey carbon film (R2/1 Cu 200, Quantifoil Micro Tools GmbH, Germany). The sample was blotted with filter paper and immediately plunge frozen in liquid ethane ...
-
bioRxiv - Microbiology 2020Quote: ... CryoET samples were prepared using copper grids with holey carbon support film (200 mesh, R2/1, Quantifoil). The grids were glow-discharged for 30 seconds before we deposited 5 μL cell solution on them ...