bioRxiv - Cell Biology 2022Quote: ... Thin sections of 50μm were obtained using a vibratome and placed onto a glow discharged electron microscopy grid (UltrAuFoil, 200 Au mesh, 2/2 Au film (Quantifoil Micro Tools)) that had been pre-clipped into Autogrids (Thermo Fisher Scientific) ...
-
bioRxiv - Cell Biology 2022Quote: ... A flat-sided planchette was placed flat side upwards and a glow discharged (Glocube, Quorum, Lewes, UK) electron microscopy grids (UltraAuFoil, 200 Au mesh, 2/2 Au film (Quantifoil Micro Tools) placed on top ...
-
bioRxiv - Molecular Biology 2023Quote: ... and samples for cryo-SPA were deposited onto 200-mesh holey carbon grids (Quantifoil Micro Tools, R 2/2 X-103-Cu200) which were first glow-discharged for 2.5 min using an ELMO glow discharge unit (Cordouan Technologies) ...
-
bioRxiv - Biochemistry 2023Quote: Farnesylated GBP1 reconstituted on liposomes (as described above) were supplemented with 5 nm colloidal gold and applied on glow-discharged UltrAuFoil R 2/2 gold grids (Quantifoil Micro Tools), flash-frozen in liquid ethane using a Vitrobot Mark II device (FEI) ...
-
bioRxiv - Microbiology 2020Quote: ... loaded onto glow-discharged carbon grids (R2/2, Quantifoil) and plunge-frozen into liquid ethane-propane mix cooled at liquid nitrogen temperatures with a Mark IV Vitrobot(Thermo Fisher Scientific ...
-
bioRxiv - Microbiology 2021Quote: EM grids (G300F1, R2/2 Quantifoil holey carbon, gold) were glow-discharged and treated with bovine fibronectin (20 μg/ml ...
-
bioRxiv - Microbiology 2020Quote: ... loaded onto glow-discharged carbon grids (R2/2, Quantifoil) and plunge-frozen into liquid ethane-propane mix cooled at liquid nitrogen temperatures with a Mark IV Vitrobot maintained at room temperature and 70% humidity ...
-
bioRxiv - Microbiology 2020Quote: ... loaded onto glow-discharged carbon grids (R2/2, Quantifoil) and plunge-frozen into liquid ethane-propane mix cooled at liquid nitrogen temperatures with a FEI Mark IV Vitrobot maintained at room temperature and 70% humidity ...
-
bioRxiv - Cell Biology 2021Quote: Carbon-coated gold TEM grids (Quantifoil NH2A R2/2) were glow-discharged at 2 mA and 1.5–1.8 × 10-1 m bar for 1 min in an ELMO (Cordouan ...
-
bioRxiv - Biochemistry 2022Quote: UltrAuFoil on gold 200 mesh R2/2 grids (Quantifoil) were subjected to micropatterning using the Primo module from Alveole mounted on a Leica DMi8 microscope following the manufacturer procedure ...
-
bioRxiv - Microbiology 2022Quote: ... loaded onto glow discharged carbon grids (R2/2, Quantifoil) and plunge-frozen using a Vitrobot Mark IV (ThermoFisher Scientific) ...
-
bioRxiv - Cell Biology 2023Quote: Carbon-coated gold TEM grids (Quantifoil NH2A R2/2) were glow-discharged at 2 mA and 1.5– × 10−1 m bar for 1 minute in an ELMO (Cordouan ...
-
bioRxiv - Biophysics 2024Quote: ... Holey carbon grids (Quantifoil Cu 300 mesh, R2/2) were prepared with fiducials by glow-discharging ...
-
bioRxiv - Biochemistry 2024Quote: ... Quantifoil Cu 200 R2/2 holey carbon grids (Quantifoil) were glow discharged negatively for 45 sec before sample application ...
-
bioRxiv - Cell Biology 2021Quote: ... Aggregation was stimulated with TRAP-6 (25μM) in a 96-well plate (15 minutes, 750rpm, 37°C; BioShake IQ, Quantifoil Instruments) and fixed with 1% formalin (Sigma) ...
-
bioRxiv - Biophysics 2022Quote: 3.5 μl of protein samples at 4-6 mg/ml were applied to glow-discharged QF R1.2/1.3 300 mesh gold grids (Quantifoil, Großlöbichau, Germany). Grids were blotted for 3 s at 4°C and 100% humidity and plunge-frozen into liquid ethane using FEI Mark IV Vitrobot (FEI ...
-
bioRxiv - Biophysics 2020Quote: The cell suspension in sea water was seeded onto R 2/2 (SiO2) on Au G200F1 finder grids (Quantifoil Micro Tools GmbH, Germany) and incubated with filtered fresh sea water at 18 °C overnight ...
-
bioRxiv - Biochemistry 2022Quote: ... Qualified nucleosomes were then loaded in a freshly glow discharged holey carbon golden grid (Quantifoil™ R 2/2 on 300 gold mesh) (1.0-2.5 µg of nucleosomes were diluted in 40 mM NaCl reconstitution buffer in 3 μL) ...
-
bioRxiv - Molecular Biology 2023Quote: ... The complex was incubated at RT for 20 mins and pipetted onto glowed discharged cryo-EM grids (Quantifoil R 2/2 Au 300). Grids were frozen in liquid ethane by using a Vitrobot Mark IV (ThermoFischer ...
-
bioRxiv - Cell Biology 2022Quote: ... Cells were then seeded onto gold grids (either ‘UltrAuFoil’ 200 Au mesh, R2/2 gold film, or Quantifoil 300 Au mesh, R2/2 carbon film (Quantifoil Micro Tools, Großlöbichau, Germany) and grown to 50 % confluency before plunge freezing ...
-
bioRxiv - Biochemistry 2023Quote: ... An aliquot (2 μL) of this polarized vesicle solution was applied onto a glow-discharged holey gold grid (Quantifoil Au R2/2, 400 mesh). After incubating the sample on the grid for 3 minutes at 10 °C with a humidity of 100% ...
-
bioRxiv - Microbiology 2020Quote: ... Quantifoil Cu R2/2 Finder grids (Quantifoil Micro Tools GmbH) were glow-discharged at 15mA for 1min ...
-
bioRxiv - Biophysics 2020Quote: UltrAuFoil R2/2 200 mesh TEM grids (Quantifoil Micro Tools) were prepared by 200 second glow discharge in 0.39 mBar of room air using a Pelco easiGlow (Ted Pella) ...
-
bioRxiv - Molecular Biology 2020Quote: Quantifoil R2/2 holey carbon copper grids (Quantifoil Micro Tool) were prepared by first applying an additional thin layer of continuous carbon and then glow-discharging them for 15 sec at 15 mA using an easiGlow Discharge cleaning system (PELCO) ...
-
bioRxiv - Biochemistry 2021Quote: Quantifoil R2/2 holey carbon copper grids (Quantifoil Micro Tool) were prepared by applying an additional thin layer of continuous carbon ...
-
bioRxiv - Molecular Biology 2022Quote: ... either carbon on Cu/Rh (Quantifoil R2/2 200 mesh) or gold on gold UltrAuFoil R1.2/1.3 300 mesh ...
-
bioRxiv - Biochemistry 2022Quote: Standard holey carbon grids (Quantifoil, Cu 200 mesh, R2/2) were glow discharged for 30 s at 15 mA on the negative setting ...
-
bioRxiv - Immunology 2024Quote: Quantifoil R2/2 holey carbon copper grids (Quantifoil, Grosslöbichau, Germany) were cleaned by overnight incubation in ethyl acetate and coated with 1 nm continuous carbon foil by floatation ...
-
bioRxiv - Biophysics 2019Quote: 3 µL of purified aldolase (1.6 mg/mL) or apoferritin (5 mg/mL) was dispensed on UltrAuFoil R1.2/1.3 300-mesh grids (Quantifoil Micro Tools GmbH) that had been freshly plasma cleaned for six seconds at 15Watts (75% nitrogen/25% oxygen atmosphere ...
-
bioRxiv - Molecular Biology 2021Quote: ... 3.5 μL was applied to a glow-discharged Quantifoil copper grid with 2 nm continuous carbon support over holes (Quantifoil R 2/4 400 mesh), blotted ...
-
bioRxiv - Cell Biology 2022Quote: The cryo-EM grid was prepared by applying 3 μl of the protein samples (4 – 6 mg/ml) to glow-discharged Quantifoil R1.2/1.3 300-mesh gold holey carbon grids (Quantifoil, Micro Tools GmbH, Germany). Grids were blotted for 4.0 seconds under 100% humidity at 4°C before being plunged into the liquid ethane using a Mark IV Vitrobot (FEI) ...
-
bioRxiv - Biophysics 2020Quote: Quantifoil grids (200 mesh Au R2/2 and Au Finder; Quantifoil Micro Tools GmbH ...
-
bioRxiv - Biochemistry 2022Quote: ... R3/3 copper grids with a 2 nm carbon coating (Quantifoil) using a Vitrobot mark IV (FEI ...
-
bioRxiv - Microbiology 2022Quote: ... EM grids (R2/2, Cu 200 mesh; Quantifoil Micro Tools GmbH) were glow-discharged for 45 sec at 25 mA by PELCO easiGlow discharger ...
-
bioRxiv - Molecular Biology 2021Quote: ... UltrAuFoil (Russo and Passmore, 2014) R2/2 200 mesh grids (Quantifoil) were glow discharged for 15 s at 30 mA in a Quorum SC7620 ...
-
bioRxiv - Microbiology 2022Quote: ... Gold quantifoil R2/2 200 mesh grids (Quantifoil Micro Tools GmbH) were sterilised with 70% ethanol and placed in glass bottomed MatTek dishes (MatTek Corporation ...
-
bioRxiv - Biochemistry 2023Quote: ... Holey carbon R2/2 300 mesh grids (Quantifoil Micro Tools GmbH) were glow-discharged for 90 sec at 25 mA using a PELCO easiGlow glow discharge cleaning system ...
-
bioRxiv - Biophysics 2021Quote: ... 3 μl of purified ghrelin-bound complex at 13 mg/ml and GHRP-6-bound ghrelin receptor complex at 8 mg/ml were applied individually onto a glow-discharged holey carbon grid (Quantifoil, Au300 R1.2/1.3) in a Vitrobot chamber (FEI Vitrobot Mark IV) ...
-
bioRxiv - Cell Biology 2020Quote: Either 200 mesh gold holey carbon grids (R2/2; Quantifoil Micro Tools) or 200 mesh gold grids (Science Services ...
-
bioRxiv - Microbiology 2022Quote: ... cells were seeded on R2/2 gold UltrAufoil grids (200 mesh, Quantifoil Micro Tools GmbH ...
-
bioRxiv - Molecular Biology 2020Quote: ... gold 300 mesh Quantifoil R2/2 holey carbon grids (Quantifoil Micro Tools) were glow discharged using an Edwards Sputter Coater 305B ...
-
bioRxiv - Biophysics 2022Quote: ... Quantifoil grids (200 mesh Au R2/2 carbon or SiO2 film; Quantifoil Micro Tools GmbH ...
-
bioRxiv - Neuroscience 2020Quote: ... electron microscopy (EM) gold finder grids (Quantifoil R2/2 Au NH2 grids) were plasma cleaned with H2 and O2 for 10 s using a plasma cleaning system (Gatan) ...
-
bioRxiv - Biochemistry 2022Quote: Quantifoil R2/2 Cu300 or Quantifoil R1.2/1.3 Cu300 (Quantifoil Micro Tools) grids were glow-discharged using the GloQube plasma cleaner (Quorum ...
-
bioRxiv - Biochemistry 2021Quote: ... grids with an additional thin layer (∼2 nm) of continues carbon (Quantifoil). The GudB6-GltA2B2 complex solution was applied to the grid in a single 2.5 µl drop ...
-
bioRxiv - Molecular Biology 2019Quote: The nucleosome-CHD4 sample was applied to R2/2 gold grids (Quantifoil). The grids were glow-discharged for 100 s before sample application of 2 µl on each side of the grid ...
-
bioRxiv - Microbiology 2022Quote: ... Quantifoil R2/2 200 mesh carbon grids (Quantifoil Micro Tools, Jena, Germany) were plasma cleaned using the Quorum Q150s glow discharger (Quorum technologies ...
-
bioRxiv - Molecular Biology 2022Quote: Quantifoil 200 mesh holey carbon R2/2 gold grids (Quantifoil Micro Tools) were glow discharged (PELCO easiGlow ...
-
bioRxiv - Microbiology 2022Quote: R2/2 carbon-coated 200 mesh copper Quantifoil grids (Quantifoil Micro Tools) were first glow-discharged for 60 seconds ...
-
bioRxiv - Molecular Biology 2023Quote: ... 4 µl of MHAS2168-Mb_H2 complex (9.4 mg/ml and 6 mg/ml) were applied to glow-discharged (45 s) holey carbon grids (Quantifoil R1.2/1.3 Au 200 mesh) and a Grid Plunger GP2 (Leica ...