Labshake search
Citations for Quantifoil Micro Tools :
401 - 450 of 709 citations for 6 Chloro 4 hydroxy 2 methyl 2H thieno 2 3 e 1 2 thiazine 3 carboxylic acid methyl ester 1 1 dioxide since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Plant Biology 2021Quote: Holey carbon grids (Quantifoil R2/1, 200 mesh) were plasma cleaned using a Solarus plasma cleaner (Gatan) ...
-
bioRxiv - Molecular Biology 2020Quote: ... transferred onto allgold UltrAuFoil R0.6/1 grids (QuantiFoil), and partially hydrogenated following a previously described procedure [17] ...
-
bioRxiv - Molecular Biology 2022Quote: ... The no carbon sample (Quantifoil Cu200 R2/1) was blotted for 1.5 s from the back side right after sample application and immediately plunge frozen in liquid ethane ...
-
bioRxiv - Molecular Biology 2022Quote: R3.5/1 Holey carbon copper grids (QUANTIFOIL, Germany) were glow-discharged by UV light ...
-
bioRxiv - Cell Biology 2023Quote: ... 200 mesh R2/1 Au EM grids (Quantifoil) were coated with laminin (1:10 dilution ...
-
bioRxiv - Cell Biology 2023Quote: ... Cu supported 3.5/1 Holey Carbon grids (Quantifoil) were glow discharged on both sides for six seconds each using atmospheric air in order to render them more hydrophilic ...
-
bioRxiv - Cell Biology 2020Quote: 4 µl of the cultured yeast cells (OD600 of 0.4) were added to a glow-discharged (30 seconds at -30 mA) copper R2/2 holey carbon grid (Quantifoil Micro Tools GmbH, Jena, Germany), then the grid was rapidly plunge frozen in liquid ethane using a homemade plunge freezer and stored in liquid nitrogen until used ...
-
bioRxiv - Biochemistry 2020Quote: ... 2.5 μL aliquots of purified Dnf1p–Lem3p or Dnf2p–Lem3p at a concentration of about 1.5 mg/mL were placed on glow-discharged holey carbon grids (Quantifoil Au R2/2, 300 mesh) and were flash-frozen in liquid ethane using a FEI Vitrobot Mark IV ...
-
bioRxiv - Cell Biology 2022Quote: ... 4 µL of the mixture were pipetted onto a copper EM grid with holey carbon film (R2/2, 200 mesh, Quantifoil Micro Tools GmbH, Q43486) that had been freshly glow-discharged for 30 s at -30 mAmp ...
-
bioRxiv - Biochemistry 2022Quote: 4 µl aliquots of purified samples at A280 = 1 were applied onto glow-discharged holey carbon-coated grids (Quantifoil 300 mesh, Au R1.2/1.3), then adsorbed for 10 s ...
-
bioRxiv - Biophysics 2022Quote: A 3 µl aliquot of freshly concentrated or thawed protein at ∼1 mg/ml was deposited on an UltraAuFoil 300 mesh R 0.6/1 grid (Quantifoil Inc., UK) at 4 °C and 100% humidity in a Vitrobot Mark IV robot (Thermo Fisher) ...
-
bioRxiv - Pathology 2023Quote: ... bombycis spores (1×108 spores/mL) were placed on grids (Cu R2/1, 200 mesh) (Quantifoil Micro Tools GmbH, Jena, Germany) for 5 min and germinated in 0.1 M KOH for 15 min at 30°C ...
-
bioRxiv - Biochemistry 2023Quote: 4 µL of protein solution (total protein concentration = 1 mg/mL) were applied to freshly glow-discharged QUANTIFOIL® R2/1 300 mesh grids (Quantifoil Micro Tools GmbH ...
-
bioRxiv - Biophysics 2019Quote: ... 3 µL of the mixture was applied to glow discharged R1.2/1.3 400 mesh grids (Quantifoil). Grids were blotted with filter paper 494 (VWR ...
-
bioRxiv - Molecular Biology 2019Quote: ... The sample (3 µl) was applied to glow discharged UltrAuFoil 300 mesh R1.2/1.3 grids (Quantifoil). Grids were blotted for 1.5 s at 16° C or 22° C and ∼100 % humidity and plunge-frozen in liquid ethane using a FEI Vitrobot Mark IV ...
-
bioRxiv - Physiology 2021Quote: ... 3 µL of the vortexed dispersion were placed on glow discharged carbon-coated grids (Quantifoil, D) for 1 minute ...
-
bioRxiv - Biophysics 2023Quote: ... 3 μl of the sample was applied to a hydrophilized grids (Quantifoil, R1.2/1.3+2nm carbon) with an additional 2 nm layer of amorphous carbon ...
-
bioRxiv - Plant Biology 2023Quote: ... 3 μl protein was applied to glow-discharged carbon grids (Quantifoil Cu R1.2/1.3 300 mesh). Subsequently ...
-
bioRxiv - Molecular Biology 2022Quote: RNA granule preparations were diluted with RNA Granule buffer to an optical density A260 = 2 U/mL aliquots of the dilution deposited on glow-discharged Quantifoil grids (Quantifoil 1.2/1.3, 300 mesh copper) pre-coated with a continuous layer of 3 nm carbon ...
-
bioRxiv - Molecular Biology 2022Quote: 3 μL of ~120 nM mitoribosome was applied onto a glow-discharged (20 mA for 30 sec) holey-carbon grid (Quantifoil R2/2, copper, mesh 300) coated with continuous carbon (of ~3 nm thickness ...
-
bioRxiv - Cell Biology 2019Quote: ... 4 µl of the solution was applied to a glow-discharged (30 s at −35 mA) copper R2/2 holey carbon grid (Quantifoil Micro Tools GmbH, Jena, Germany). After removing excess liquid by blotting the grid from the back side with Whatman filter paper No ...
-
bioRxiv - Microbiology 2019Quote: ... Four μl of this mixture was applied onto freshly glow-discharged copper R2/2 of th0 Quantifoil holey carbon grids (Quantifoil Micro Tools GmbH, Jena, Germany). Using an FEI Vitrobot Mark IV ...
-
bioRxiv - Biochemistry 2022Quote: ... The endogenous samples were applied onto grids containing an additional thin layer of continuous carbon support (Quantifoil R1.2/1.3 Cu 200 mesh + 2 nm C) and incubated for 30 sec before blotting and freezing ...
-
bioRxiv - Biochemistry 2023Quote: 3 μL of ∼120 nM mitoribosome was applied onto a glow-discharged (20 mA for 30 sec) holey- carbon grid (Quantifoil R2/2, copper, mesh 300) coated with continuous carbon (of ∼3 nm thickness ...
-
bioRxiv - Biophysics 2023Quote: ... 4 μl of the extracellular parasites were pipetted onto a glow-discharged (30 seconds at −30 mA) copper R2/2 holey carbon grid (Quantifoil Micro Tools GmbH, Jena, Germany). Samples were back-blotted with a Whatman filter paper (grade 1 ...
-
bioRxiv - Biochemistry 2023Quote: ... 3 μL of ∼120 nM mitoribosome was applied onto a glow-discharged (20 mA for 30 sec) holey-carbon grid (Quantifoil R2/2, copper, mesh 300) coated with continuous carbon (of ∼3 nm thickness ...
-
bioRxiv - Cell Biology 2022Quote: 2 x 104 TauRD-Y* cells or 1 x 105 neurons were seeded on EM grids (R2/1, Au 200 mesh grid, Quantifoil Micro Tools) in a 35 mm dish or 24-well plate and cultured for 24 h or transduced with lentivirus and treated with aggregate-containing cell lysate as described earlier in section ‘Primary neuronal cultures’ ...
-
bioRxiv - Microbiology 2021Quote: ... holey carbon grids (Quantifoil R2/1 200 mesh copper) for 1 min ...
-
bioRxiv - Biochemistry 2022Quote: UltrAuFoil gold grids (0.6/1, Quantifoil Micro Tools GmbH)56 were prepared as described previously9 ...
-
bioRxiv - Biophysics 2019Quote: ... perforated carbon copper grid (Quantifoil R2/1 200 mesh). The nuclei were opened manually and the nuclear envelopes spread over the grid ...
-
bioRxiv - Cell Biology 2021Quote: Holey carbon grids (Quantifoil R2/1, 200 mesh, gold) were washed in acetone while agitating on a rocker for 15 to 30 min to remove potential residual plastic backing ...
-
bioRxiv - Biochemistry 2023Quote: ... holey carbon grids (Quantifoil, 300 mesh Au R0.6/1) glow-discharged for 50 seconds were used for EM grids preparation ...
-
bioRxiv - Cell Biology 2023Quote: ... Cryo-EM grid (Quantifoil R3.5/1, Au 200 mesh) was glow discharged using Gatan Solarus for 60 s ...
-
bioRxiv - Biochemistry 2023Quote: ... R2/1 holey carbon without amorphous carbon from Quantifoil. 3 µL of a 2.5 µM solution was applied to the grid ...
-
bioRxiv - Molecular Biology 2020Quote: 3 μL of sample was applied onto a holey carbon grid (Quantifoil, Cu, R1.2/1.3, 300 mesh) rendered hydrophilic by a 30 s glow-discharge in air (11 mA current with PIB-10) ...
-
bioRxiv - Plant Biology 2021Quote: Concentrated PSII solution (3 µl) was applied on glow-discharged holey carbon grids (Cu Quantifoil R1.2/1.3) that were vitrified for cryo-EM structural determination using a Vitrobot FEI (3 s blot at 4°C and 100% humidity) ...
-
bioRxiv - Molecular Biology 2022Quote: ... The sample (3 μL) was applied to freshly glow-discharged Au 300 mesh R1.2/1.3 grids (Quantifoil) in a Vitrobot Mark IV (FEI ...
-
bioRxiv - Biophysics 2021Quote: ... 3 μL was applied to Ultrafoil grids (R1.2/1.3, Au/Au, 300 mesh, Quantifoil Micro Tools GmbH) that had been glow-discharged for 2 min using a Pelco easiGlow (Ted Pella ...
-
bioRxiv - Pharmacology and Toxicology 2022Quote: Samples (3 µL) were applied to glow-discharged Quantifoil R1.2/1.3 Cu/Rh 200 mesh grids (Quantifoil) (M4R-Gi1-Ipx and M4R-Gi1-Ipx-LY298 ...
-
bioRxiv - Biophysics 2023Quote: ... 3 µL sample was applied to a freshly glow-discharged UltrAuFoil R1.2/1.3 300 mesh grids (Quantifoil), blotted with Whatman No ...
-
bioRxiv - Biochemistry 2023Quote: ... 3 μl diluted protein sample was put on freshly glow-discharged Quantifoil R1.2/1.3 Cu grid (Quantifoil Micro Tools GmbH ...
-
bioRxiv - Biophysics 2019Quote: ... Approximately 5 µL of sample (diluted if necessary) was placed on a copper grid (Quantifoil® S7/2 Cu 400 mesh, holey carbon films, Quantifoil Micro Tools GmbH, Jena, Germany) and any excess liquid was absorbed by a filter paper ...
-
bioRxiv - Biochemistry 2022Quote: The samples were frozen on copper or gold grids with holey carbon film coated with a 2 nm continuous carbon film (Quantifoil R1.2/1.3 ultrathin carbon, 300 mesh) freshly glow discharged for 20 s at 15 mA (PELCO easiGlow) ...
-
bioRxiv - Neuroscience 2023Quote: ... 3.5 μL of CopiaGag capsid protein sample was applied to a 300-mesh copper grid with continuous 2 nm carbon film (Electron Microscopy Sciences, QUANTIFOIL® C2-C15nCu30-50) at 10 °C with 90% humidity in a Vitrobot Mark IV (FEI) ...
-
bioRxiv - Biochemistry 2023Quote: 3.5 µl purified TOL-1–LAT-1 full-ectodomain complex (0.28 mg/ml) was applied on glow-discharged holey carbon grids (Quantifoil R1.2/1.3, 200 mesh), and vitrified using a Vitrobot Mark IV (FEI Company) ...
-
bioRxiv - Molecular Biology 2024Quote: ... about 0.9 mg/ml for DSS1–INTAC–PEC complex) was applied onto a glow-discharged holey carbon grid (Quantifoil Au, R1.2/1.3 or R2/2, 300 mesh). After blotting for 3 to 6 s ...
-
bioRxiv - Microbiology 2021Quote: ... 3 μl of each sample was dispensed on Quantifoil R1.2/1.3 200-mesh grids (Quantifoil Micro Tools GmbH) that had been freshly glow discharged for 30 seconds at 20 mA using a PELCO easyGLow™ Glow Discharge Cleaning System (Tedpella) ...
-
bioRxiv - Immunology 2022Quote: ... 3 μl of sample was then dispensed on Quantifoil R1.2/1.3 200-mesh grids (Quantifoil Micro Tools GmbH) that had been freshly glow discharged for 30 s at 20 mA ...
-
bioRxiv - Biochemistry 2022Quote: ... 3 µl of TIR-SAVED complex was applied to Holey Carbon grids (Quantifoil Cu R1.2/1.3, 300 mesh), glow discharged for 45 s at current of 45 mA in a EMITECH K100X glow discharger ...
-
bioRxiv - Molecular Biology 2020Quote: A 3 μL sample solution was applied to a Quantifoil holey carbon grid R1.2/1.3 Mo 200 mesh (Quantifoil Micro Tools GmbH ...