Labshake search
Citations for Quantifoil Micro Tools :
301 - 350 of 708 citations for 6 Chloro 2 4 chlorophenyl N N dimethylimidazo 1 2 α pyridine 3 methanamine since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Cell Biology 2022Quote: Cells were applied onto galectin-8 coated EM grids with carbon support film (R2/2, Au mesh; Quantifoil, Jena, Germany). After 15-20 min incubation ...
-
bioRxiv - Biophysics 2019Quote: Three microliters of isolated pilus suspension were pipetted onto a glow-discharged R2/2 Cu 300 mesh holey carbon-coated grids (Quantifoil). Grids were plunge frozen in liquid ethane after blotting using a Vitrobot Mark IV (Thermo Fisher ...
-
bioRxiv - Microbiology 2019Quote: ... Fixed Brucella cells were vitrified on glow-discharged 200 mesh copper EM-grids with extra thick R2/2 holey carbon film (Quantifoil). Per grid ...
-
bioRxiv - Cell Biology 2021Quote: HeLa Doxycycline-inducible stable cell lines were grown for approximately 48 h on holey carbon gold EM grids (200 mesh, R2/2, Quantifoil) prior to plunge freezing ...
-
bioRxiv - Microbiology 2020Quote: ... 3,5 μl of the culture was mixed with 10 nm gold fiducial markers (Cell Microscopy Core, UMC Utrecht) and applied onto glow-discharged R2/2 200 mesh holey carbon EM grids (Quantifoil). The grid was then rapidly plunged in liquid ethane using the Leica GP automated freeze-plunger ...
-
bioRxiv - Synthetic Biology 2019Quote: ... 4μL of PEG-precipitation purified DNA origami were applied on glow-discharged Quantifoil R2/2 copper grids (Quantifoil Micro Tools) and plunge frozen in liquid ethane cooled liquid nitrogen using a Lecia EM GP device (Leica Microsystem) ...
-
bioRxiv - Evolutionary Biology 2020Quote: ... was applied onto a glow-discharged (20 mA for 30 seconds) holey-carbon grid (Quantifoil R2/2, copper, mesh 300) coated with continuous carbon (of ~3 nm thickness ...
-
bioRxiv - Biochemistry 2021Quote: ... 3.5 μL sample was applied onto a freshly glow-discharged 200-mesh copper 2 nm C R1.2/1.3 grids (Quantifoil Micro Tools). The grids were blotted for 1 s and plunge-vitrified in liquid ethane ...
-
bioRxiv - Biochemistry 2022Quote: ... 2–2.5 µl of protein solution was applied to glow-discharged holey carbon grids (Quantifoil R1.2/1.3 Au 200 mesh). The endogenous samples were applied onto grids containing an additional thin layer of continuous carbon support (Quantifoil R1.2/1.3 Cu 200 mesh + 2 nm C ...
-
bioRxiv - Molecular Biology 2023Quote: ... Samples for cryo-ET were deposited onto 300-mesh holey carbon grids (Quantifoil Micro Tools, R2/2 X-103-Cu300) and samples for cryo-SPA were deposited onto 200-mesh holey carbon grids (Quantifoil Micro Tools ...
-
bioRxiv - Biophysics 2023Quote: A 3 µL aliquot of purified CDTbD623A/D734Aprotein sample at a concentration of 30 µM was applied to a glow discharged QUANTIFOIL® copper R 1.2/1.3 grid with a 2 nm thin extra carbon layer (QUANTIFOIL, GMBH). For calcium depleted CDTb (28 µM) ...
-
bioRxiv - Biochemistry 2023Quote: 2.4 µL of sample were applied to a freshly glow discharged 200-mesh Cu + 2 nm C R1.2/1.3 grid (Quantifoil Micro Tools), blotted for 6 s at 100% humidity ...
-
bioRxiv - Biophysics 2023Quote: ... 3 or 3.5 μl of LRRK2RCKW:inhibitor:E11 DARPin complex were applied to a glow-discharged UltraAuFoil Holey Gold 200 mesh R2/2 grid (Quantifoil, Catalog # Q250AR2A) and incubated in a FEI Vitrobot IV chamber at 4°C and 95% humidity for 20 sec ...
-
bioRxiv - Cell Biology 2024Quote: ... 4 × 104 MDM cells were seeded on glow discharged and UV-light sterilized holey carbon grids (R2/2, Au, 200 mesh, Quantifoil), which were placed in a glass-bottomed ‘microwell’ of 35-mm MatTek dish (MatTek ...
-
bioRxiv - Biochemistry 2023Quote: ... by applying 3 μL of it to plasma-cleaned 0.6/1 μm holey gold UltrAuFoil grids (Quantifoil). Following a 30 s incubation ...
-
bioRxiv - Biophysics 2019Quote: ... of suspended crystals was loaded on one side of glow-discharged Quantifoil EM grids (R2/2, Cu 300 mesh; QUANTIFOIL Company). The grid was then blotted from the other side and washed twice manually with 4 μL 5% v/v PEG 200 buffer ...
-
bioRxiv - Microbiology 2019Quote: ... The EM-grids were glow-discharged 200 mesh copper grids with an extra thick R2/2 carbon film (Quantifoil Micro Tools). 3,5 µl of the sample was applied to the EM grid and blotted at a temperature of 16°C and a humidity between 95-99% ...
-
bioRxiv - Biophysics 2019Quote: ... The Netherlands) as fiducial markers and glow-discharged R2/2 Cu 300 mesh holey carbon-coated support grids (Quantifoil, Jena, Germany) were dipped into the solution ...
-
bioRxiv - Plant Biology 2021Quote: ... 3 µl of suspended cells in culture medium were applied to the front side of glow-discharged R2/2 carbon-coated copper grids (Quantifoil MicroTools), with additional 1 µL cells added to the back side ...
-
bioRxiv - Biochemistry 2021Quote: ... Three microliters of the protein solution were applied on a glow-discharged holey carbon grids (200 mesh Quantifoil R2/2 molybdenum), which had been treated with H2 and O2 mixtures in a Solarus plasma cleaner (Gatan ...
-
bioRxiv - Cell Biology 2022Quote: ... The IL-11Δ10/IL-11RαD1-D3/gp130D1-D3 complex (0.5 mg/mL) was blotted onto UltrAuFoil grids (R2/2, Quantifoil Micro Tools GmbH) that had been subjected to glow discharge (15 mA for 30 s) ...
-
bioRxiv - Biophysics 2023Quote: ... 3 to 3.5 μl of complex was applied to a glow-discharged UltrAuFoil Holey Gold 200 mesh R2/2 grid (Quantifoil, Catalog # Q250AR2A) and incubated in a FEI Vitrobot IV chamber at 4°C and 95% humidity for 20 sec ...
-
bioRxiv - Biochemistry 2022Quote: ... 3 μl of sample were applied onto a freshly glow-discharged copper R2/1 300 mesh grid (Quantifoil), blotted for 8 s on both sides with blotting force −15 and plunge-frozen in liquid ethane.
-
bioRxiv - Biochemistry 2022Quote: ... 3 μl of sample were applied onto a freshly glow-discharged copper R2/1 300 mesh grid (Quantifoil), blotted for 8 s on both sides with blotting force −15 and plunge-frozen in liquid ethane.
-
bioRxiv - Molecular Biology 2022Quote: ... 3 μl of protein sample was applied to holey carbon grids (Quantifoil, R 0.6/1 Cu 200 mesh) which were H2/O2 glow-discharged for 30 s ...
-
bioRxiv - Biochemistry 2022Quote: ... 3 μl of purified PP2A-PME-1 complex was applied onto a glow-discharged holey carbon grid (Quantifoil 300 mesh R 1.2/1/3 with ultrathin carbon ...
-
Mechanism of actin-dependent activation of nucleotidyl cyclase toxins from bacterial human pathogensbioRxiv - Biochemistry 2021Quote: ... 3 μl of sample were applied onto a freshly glow-discharged copper R2/1 300 mesh grid (Quantifoil), blotted for 8 s on both sides with blotting force −20 and plunge-frozen in liquid ethane.
-
bioRxiv - Molecular Biology 2022Quote: ... aliquots of 3 μl were applied to glow discharged grids (R2/1 or R1.2/1.3, Au 300, Quantifoil), blotted for 2 s and immediately plunge-frozen in liquid ethane using an FEI Vitrobot IV at 4°C and 100 % humidity ...
-
bioRxiv - Physiology 2023Quote: ... Sample solution (~ 3 μl) was applied on freshly glow discharge TEM grids (Quantifoil R2/1, Cu, mesh 200) and plunge-frozen in liquid ethane using Vitrobot Mark IV (Thermo Fisher Scientific) ...
-
bioRxiv - Biophysics 2021Quote: 3 μl of the human sperm sample were applied to glow discharged copper R2/2 200-mesh holey carbon grid (Quantifoil Micro Tools) and plunge frozen in liquid ethane using an automatic plunge freezer (Vitrobot ...
-
bioRxiv - Cell Biology 2020Quote: ... Cells were incubated at 37°C and 5% CO2 for 16h prior to trypsinization and seeding onto 200 mesh gold holey carbon grids (R2/2-2C; Quantifoil Micro Tools), which were placed in 3D printed grid holders [39] ...
-
bioRxiv - Molecular Biology 2021Quote: ... After another 3 min at 37 °C the termination complexes were placed on ice for 15 min and subsequently applied to Quantifoil R2/2 holey carbon grids (Quantifoil Micro Tools) either coated with a thin continuous carbon film or with graphene oxide flakes (Sigma-Aldrich) ...
-
bioRxiv - Biophysics 2019Quote: 3.5 μl of sample of fragmented doublets (~4 mg/ml) or the Sarkosyl A-tubule (~500 μg/ml) was applied to a glow-discharged holey carbon grid (Quantifoil R2/2), blotted and plunged into liquid ethane using Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Cell Biology 2021Quote: ... 4 µl of the solution was applied to a glow-discharged (30s at 35 mA) copper R2/2 holey carbon grid (Quantifoil Micro Tools). After removing excess liquid by blotting the grid from the back side with Whatman filter paper for 2 s ...
-
bioRxiv - Cell Biology 2020Quote: ... Samples were applied to freshly glow-discharged (Edwards S150B, 45 sec, 30-50 mA, 1,2kV, 10-2 mbar) copper holey carbon grids (Quantifoil, Cu-R1.2/1.3) under 100% humidity ...
-
bioRxiv - Molecular Biology 2022Quote: ... 3 μl of the mixture was deposited on glow discharged R2/2 Copper 300 mesh holey carbon-coated support grids (Quantifoil, Jena, Germany) along with 1 μl of HEPES pH 10 and 1 μl of hydrogen peroxide 0.9 % ...
-
bioRxiv - Neuroscience 2021Quote: ... 400 mesh Quantifoil R1.2/1.3 grids with empty holes and 400 mesh Quantifoil R1.2/1.3 grids coated with a 2 nm thin carbon layer (Quantifoil Micro Tools GmbH, Germany). The grids were rendered hydrophilic by glow discharge using a Pelco easiGlow glow discharger (Ted Pella Inc. ...
-
bioRxiv - Microbiology 2020Quote: ... Cells were concentrated by centrifugation and 3 μL aliquots of the cell suspension are applied to glow-discharged R2/2 200 mesh copper Quanti-foil grids (Quantifoil Micro Tools), the sample was pre-blotted for 30 seconds ...
-
bioRxiv - Cell Biology 2020Quote: ... A 5 µl drop of the chemically fixed cell culture was deposited on a glow-discharged Quantifoil 200 mesh R2/2 electron microscopy grid (Quantifoil, Großlöbichau, Germany) pre-coated with a gold bead solution ...
-
bioRxiv - Biochemistry 2020Quote: ... 3 µL aliquots of 0.1 mg/ml cross-linked ternary complexes were applied to freshly glow-discharged R2/2 Quantifoil 200 mesh copper grids (Quantifoil Micro Tools). Grids were blotted in a climate chamber set to 20 °C and at 95% humidity before plunge frozen in liquid ethane set at −183 °C using a Leica EM GP system (Leica Microsystems) ...
-
Computational toolbox for ultrastructural quantitative analysis of filament networks in cryo-ET databioRxiv - Cell Biology 2021Quote: B16-F1 cells were cultured as described above and seeded onto 200 mesh gold holey carbon grids (R2/2-2C; Quantifoil Micro Tools). Prior to cell seeding ...
-
bioRxiv - Cell Biology 2022Quote: ... 3 μl of the resulting mixture was spotted onto glow-discharged copper EM grids (Quantifoil 300 Au mesh, R2/2 carbon film (Quantifoil Micro Tools). The grids were then blotted for 2 or 4 seconds (blot force −10 ...
-
bioRxiv - Biochemistry 2023Quote: ... Samples were applied to freshly glow-discharged (Edwards S150B, 45 s, 30−50 mA, 1.2 kV, 10−2 mbar) copper holey carbon grids (Quantifoil, Cu-R1.2/1.3) under 100% humidity at 4°C.
-
bioRxiv - Biochemistry 2023Quote: 4.5 µL of freshly mixed Nup98 condensate and capsid mixture with protein A-gold (10 nm) were applied onto a glow-discharged Quantifoil R2/2 copper grid (Quantifoil Micro Tools). The grid was blotted in the front for 2.5 s at 15 °C with 90% relative humidity and then plunged into liquid ethane using a Lecia EM GP device (Lecia Microsystem) ...
-
bioRxiv - Cell Biology 2024Quote: ... An aliquot of a 5 μl sample was applied to a glow-discharged holey carbon grid (Quantifoil R2/2, Au, 400 mesh). After waiting for 60 s ...
-
bioRxiv - Biophysics 2022Quote: A volume of 4-7 µl of cells were deposited on R2/1 Cu 200 grids (Quantifoil) that had been glow-discharged for 1 min at 0.19 mbar and 20 mA in a PELCO easiGlow device shortly before use ...
-
bioRxiv - Neuroscience 2022Quote: Primary cultured neurons were seeded onto holey gold EM grids (Quantifoil R 1/4 gold 200 mesh). The fiducial marker solution was prepared as for neocortical synaptosomes ...
-
bioRxiv - Cell Biology 2024Quote: ... Quantifoil Holey SiO2 R 1/4 Au 200 mesh EM grids (Quantifoil Micro Tools #N1-s13nAi20-01) were glow discharged on both sides in a Pelco easyglow for 45 s at 0.37 mBar and 15 mA ...
-
bioRxiv - Biophysics 2022Quote: Purified wt or mutant D263A or F55A MVMp capsid samples (5 μl) were applied onto R2/2 300 mesh copper grids (Quantifoil Micro Tools, Germany) and vitrified using a Leica EM CPC cryofixation unit ...
-
bioRxiv - Cancer Biology 2020Quote: ... 3 μL of urease samples at 1.3 mg/mL with 1 mM BME or with 10 mM SHA were applied to freshly glow-discharged Quantifoil R2/2 holey carbon grids (Quantifoil Micro Tools, Germany). The grids were blotted for 4 seconds ...