Labshake search
Citations for Quantifoil Micro Tools :
1 - 50 of 377 citations for 6 6 dimethyl 1 phenyl 6 7 dihydro 1H indazol 4 5H one since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biophysics 2022Quote: 3.5 μl of protein samples at 4-6 mg/ml were applied to glow-discharged QF R1.2/1.3 300 mesh gold grids (Quantifoil, Großlöbichau, Germany). Grids were blotted for 3 s at 4°C and 100% humidity and plunge-frozen into liquid ethane using FEI Mark IV Vitrobot (FEI ...
-
bioRxiv - Biophysics 2023Quote: ... Aliquots of 4 μl of protein samples (0.3 mg ml-1 or ∼6 μM) were applied to glow-discharged R1.2/1.3 200 Cu mesh grids (Quantifoil). After 30 s ...
-
bioRxiv - Cell Biology 2022Quote: The cryo-EM grid was prepared by applying 3 μl of the protein samples (4 – 6 mg/ml) to glow-discharged Quantifoil R1.2/1.3 300-mesh gold holey carbon grids (Quantifoil, Micro Tools GmbH, Germany). Grids were blotted for 4.0 seconds under 100% humidity at 4°C before being plunged into the liquid ethane using a Mark IV Vitrobot (FEI) ...
-
bioRxiv - Neuroscience 2023Quote: ... Double application of 3 µL protein (∼0.6 mg/mL) SYM2081 complex was carried out on glow-discharged gold grids (R 0.6/1, 300 mesh, Quantifoil). The grids were blotted for 4.5 s and 3.5 s ...
-
bioRxiv - Biophysics 2019Quote: An aliquot of 4 μl of 6 μM Ac-E46K α-syn fibril solution was applied to a glow-discharged holey carbon grid (Quantifoil R1.2/1.3, 300 mesh), blotted for 6.5 s ...
-
bioRxiv - Biochemistry 2023Quote: ... Four microliters of purified Cx36 proteins (4-6 mg/ml) were applied onto a negatively glow-discharged holey carbon grid (Quantifoil R1.2/1.3 Cu 300 mesh). For samples involving Cx36-WT ...
-
bioRxiv - Biophysics 2021Quote: To provide extra support for cell growth 5-6 nm of carbon was evaporated onto Quantifoil Au 200 R2/1 or R2/2 grids (Quantifoil Micro Tools GmbH). Grids were then glow discharged and incubated in supplemented RPMI-1640 overnight in the cell incubator ...
-
bioRxiv - Biophysics 2020Quote: ... This sample was used for EM dataset 6: the purified sample was applied to Cu 300 R1.2/1.3 holey carbon grids (Quantifoil) coated with a ∼7 nm homemade carbon film ...
-
bioRxiv - Biophysics 2020Quote: ... 3.5 µl of purified channel proteins at ∼6 mg/ml were pipetted onto glow-discharged copper Quantifoil R2/2 holey carbon grids (Quantifoil). Grids were blotted for 2 s at ∼100% humidity and flash frozen in liquid ethane ...
-
bioRxiv - Cell Biology 2021Quote: ... Aggregation was stimulated with TRAP-6 (25μM) in a 96-well plate (15 minutes, 750rpm, 37°C; BioShake IQ, Quantifoil Instruments) and fixed with 1% formalin (Sigma) ...
-
bioRxiv - Biophysics 2019Quote: 3 µL of purified aldolase (1.6 mg/mL) or apoferritin (5 mg/mL) was dispensed on UltrAuFoil R1.2/1.3 300-mesh grids (Quantifoil Micro Tools GmbH) that had been freshly plasma cleaned for six seconds at 15Watts (75% nitrogen/25% oxygen atmosphere ...
-
bioRxiv - Microbiology 2021Quote: ... 4-7 µl of cells were deposited on R2/1 Cu 200 grids (Quantifoil) that had been glow-discharged for 1 min at 0.19 mbar and 20 mA in a PELCO easiGlow device shortly before use ...
-
bioRxiv - Biophysics 2021Quote: ... 3 μl of purified ghrelin-bound complex at 13 mg/ml and GHRP-6-bound ghrelin receptor complex at 8 mg/ml were applied individually onto a glow-discharged holey carbon grid (Quantifoil, Au300 R1.2/1.3) in a Vitrobot chamber (FEI Vitrobot Mark IV) ...
-
bioRxiv - Molecular Biology 2023Quote: ... 4 µl of MHAS2168-Mb_H2 complex (9.4 mg/ml and 6 mg/ml) were applied to glow-discharged (45 s) holey carbon grids (Quantifoil R1.2/1.3 Au 200 mesh) and a Grid Plunger GP2 (Leica ...
-
bioRxiv - Biophysics 2020Quote: ... 2 μL of a 1 in 6 dilution of the batch crystallisation was applied to the carbon side of glow discharged R2/2 Quantifoil™ grids (Quantifoil Micro Tools, Jena, Germany). Excess liquid was removed by blotting for 4-6 s with a Vitrobot (Thermo Fisher ...
-
bioRxiv - Microbiology 2023Quote: Aliquots of 3.5 μL SbtA-SbtB (ΔT-loop) samples (∼6 mg/mL) were applied to the glow-discharged grids (Quantifoil holey carbon Cu R1.2/1.3 grid). Grids were blotted for 4.5 sec and plunge-frozen in liquid ethane vitrified by liquid nitrogen using Vitrobot Mark IV (FEI Company ...
-
bioRxiv - Biochemistry 2024Quote: ... or calpain-3-titin/I81-I83 (2mg/mL) from Superose 6 increase 10/300GL column chromatography was loaded onto glow-discharged holey carbon grids (Quantifoil 1.2/1.3 + 2 nm Carbon). The grids were blotted with filter paper for 2.5 secs at 22 °C and then immediately plunged into liquid ethane cooled by liquid nitrogen using a Vitrobot Mark IV (Thermo Fisher Scientific) ...
-
bioRxiv - Biophysics 2022Quote: A volume of 4-7 µl of cells were deposited on R2/1 Cu 200 grids (Quantifoil) that had been glow-discharged for 1 min at 0.19 mbar and 20 mA in a PELCO easiGlow device shortly before use ...
-
bioRxiv - Cell Biology 2024Quote: ... with holey R 1/4 carbon film (Quantifoil Micro Tools GmbH) were glow-discharged for 30 seconds at 5 mA using an EasiGlow system (Pelco ...
-
bioRxiv - Biophysics 2023Quote: ... HeLa cells were trypsinized and seeded at a density of 0.5 – 0.7 X 105 cells/mL on carbon-coated gold Quantifoil grid (200 mesh, R 2/1, holey SiO2 film; Quantifoil Micro Tools GmbH ...
-
bioRxiv - Plant Biology 2020Quote: ... 4 μL of cell culture was blotted onto R 1/4 SiO2-coated 200-mesh gold EM grids (Quantifoil Micro Tools) and plunge frozen in a liquid ethane/propane mixture ...
-
bioRxiv - Microbiology 2023Quote: ... Gold grids with SiO2 film (Quantifoil, Au 200 mesh, R 1/4) were glow- discharged and coated with 20 µg/ml fibronectin solution for 30 min ...
-
bioRxiv - Plant Biology 2019Quote: ... 4 µL of mat3-4 cell culture was blotted onto R2/1 carbon-coated 200-mesh copper EM grids (Quantifoil Micro Tools) and plunge frozen in a liquid ethane/propane mixture ...
-
bioRxiv - Biophysics 2023Quote: ... 3 μl of medium containing one isolated muscle fibre was placed on the glow-discharged grid (Quantifoil R2/1 Au 200 mesh). After incubation for 60 seconds at 37 °C ...
-
bioRxiv - Biophysics 2021Quote: ... 4 μl of cell suspension was applied to holey carbon R2/1 Cu grids (Quantifoil) and plunge-frozen on a Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Microbiology 2019Quote: ... 4 μL of sample was applied to glow-discharged EM grids (R2/1 copper, Quantifoil), blotted twice from the back for 3.5 s and vitrified in liquid ethane–propane using a Vitrobot Mark IV (ThermoFisher) ...
-
bioRxiv - Cell Biology 2024Quote: Quantifoil R2/1 or SiO2 R1/4 gold grids (both Quantifoil Mirco Tools GmbH, Germany) were briefly washed in chloroform and placed on drops of poly-D-lysine (100 µg/ml) ...
-
bioRxiv - Biophysics 2019Quote: ... 3.5 μl aliquots of the recombinant human TIM22 complex (7 mg ml-1) were dropped onto glow discharged holey carbon grids (Quantifoil Au R1.2/1.3, 300 mesh), blotted with a Vitrobot Mark IV (ThemoFisher Scientific ...
-
bioRxiv - Neuroscience 2022Quote: Primary cultured neurons were seeded onto holey gold EM grids (Quantifoil R 1/4 gold 200 mesh). The fiducial marker solution was prepared as for neocortical synaptosomes ...
-
bioRxiv - Cell Biology 2024Quote: ... Quantifoil Holey SiO2 R 1/4 Au 200 mesh EM grids (Quantifoil Micro Tools #N1-s13nAi20-01) were glow discharged on both sides in a Pelco easyglow for 45 s at 0.37 mBar and 15 mA ...
-
bioRxiv - Biochemistry 2021Quote: ... 3 microlitres of undiluted eluate and of eluate which was diluted 1:2 or 1:4 in buffer A200 were blotted onto holey carbon R 1.2/1.3 copper 300 mesh grids (Quantifoil) and vitrified in liquid ethane using a Vitrobot MarkIV device (Thermofisher) ...
-
bioRxiv - Biochemistry 2024Quote: ... 4 uL of the concentrated sample was applied to freshly glow-discharged R2/1 holey carbon grids (Quantifoil), blotted with blot force of 5 for 5 s using a Vitrobot Mark IV (Thermo Fisher ...
-
bioRxiv - Molecular Biology 2021Quote: Purified mtLSU or 55S mitoribosome samples (4 μL) were applied to freshly glow discharged R 3.5/1 holey carbon grids (Quantifoil) that were precoated with a 2-3 nm carbon layer using a Leica EM ACE600 coater ...
-
bioRxiv - Biophysics 2021Quote: ... Log phase cultures were centrifuged at 2000 g for 2 minutes to concentrate the cells 10 times and 4 μl was directly applied to a glow-discharged holey carbon R2/1 Cu 200 mesh grid (Quantifoil). Plunge-freezing was performed using a VitroBot Mark 4 (Thermo Fisher Scientific ...
-
bioRxiv - Microbiology 2023Quote: ... trehalose solution to mitigate crystalline ice formation and 4 μL of this mixture immediately applied to a R2/1 Cu 200 grid (Quantifoil), which had been glow-discharged for 1 min at 0.19 mbar and 20 mA in a PELCO easiGlow device shortly before use ...
-
bioRxiv - Biophysics 2023Quote: ... 4 µL fresh sample (0.48 mg/mL) was applied on glow-discharged Au holey carbon grids (Quantifoil R 0.6/1) and the following operation were the same as describe above for preparing the sample of gMCM8/9 complex.
-
bioRxiv - Biophysics 2023Quote: ... 200 mesh R1/4 or R2/4 Quantifoil holy carbon gold grids (Quantifoil®, Grossloebichau/Jena Germany). were glow discharged in Pelco easiGlow (Ted Pella ...
-
bioRxiv - Molecular Biology 2021Quote: ... cells in suspension (4 μl of ~1,000 cells per μl) were blotted onto R2/1 carbon-coated 200-mesh copper grids (Quantifoil Micro Tools) and plunge frozen in a liquid ethane/propane mixture ...
-
bioRxiv - Microbiology 2023Quote: ... This mixture was applied to the front (3.7 µL) and to the back (1.3 µL) of carbon-coated copper grids (R2/2, Cu 200 mesh; Quantifoil) previously glow-discharged (2 mA ...
-
bioRxiv - Cell Biology 2024Quote: ... the sample was gently resuspended and 4 µl was transferred to a glow-discharged holey carbon R2/1 copper grid (Quantifoil Micro Tools) suspended in the chamber of a Vitrobot (Thermo Fisher Scientific) ...
-
bioRxiv - Molecular Biology 2021Quote: ... a 3.5 μL aliquot at 0.1 mg·ml−1 was applied to one side of a Quantifoil 400 mesh 1.2/1.3 gold grid with graphene oxide support film (Quantifoil). After 30 s ...
-
bioRxiv - Biochemistry 2023Quote: ... Cryo-EM grids were prepared by applying 3.5 μL of protein sample at a concentration of 0.25 mg/ml to one side of a Quantifoil 400 mesh 1.2/1.3 gold grid with graphene oxide support film (Quantifoil). After 30 s ...
-
bioRxiv - Cell Biology 2020Quote: ... or holey SiO2 R1/4 TEM grids (Quantifoil) to allow for more robust correlation and cells were plunge frozen on a Vitrobot Mark IV (FEI ...
-
bioRxiv - Cell Biology 2022Quote: ... Grids (200 Mesh Cu SiO2 R1/4, Quantifoil) were plasma cleaned for 30 s before plunging ...
-
bioRxiv - Molecular Biology 2023Quote: ... a 4 µl sample of purified complex was applied to glow-discharged R2/1 300 mesh holey carbon copper grids (Quantifoil Micro Tools GmbH), using a conc ...
-
bioRxiv - Cell Biology 2023Quote: 4 ul of Nannochloropsis suspensions (4 x 107 cells mL−1) were pipetted onto a 300 mesh gold Quantifoil grid with 2um holes (Quantifoil Micro Tools, GmbH) and manually blotted from the opposite side in a Vitrobot Mark IV (ThermoFisher Scientific ...
-
bioRxiv - Molecular Biology 2019Quote: ... 2.4 μl of 0.12 mg/ml of the protein preparation were applied to glow-discharged holey carbon grids (Quantifoil, QF 2/1, 300 mesh) covered with a 2 nm carbon layer ...
-
bioRxiv - Biochemistry 2022Quote: 4 µl aliquots of purified samples at A280 = 1 were applied onto glow-discharged holey carbon-coated grids (Quantifoil 300 mesh, Au R1.2/1.3), then adsorbed for 10 s ...
-
bioRxiv - Biophysics 2021Quote: Gold EM grids with R1/4 holey SiO2 film (Quantifoil) were glow-discharged in a EasiGlow (Pelco ...
-
bioRxiv - Cell Biology 2019Quote: ... R1/4 or R1/20 (Quantifoil Micro Tools, Jena, Germany) were employed in this study ...