Labshake search
Citations for Quantifoil Micro Tools :
251 - 300 of 430 citations for 4 METHANESULPHONYLBUTAN 2 ONE since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Molecular Biology 2021Quote: ... bremelanotide– or THIQ–bound MC4R–Gs complexes at ∼ 4 mg/mL were applied onto glow-discharged holey carbon grids (Quantifoil R1.2/1.3). Excess samples were blotted away and the grids were vitrified by plunging into liquid ethane using a Vitrobot Mark IV (ThermoFischer Scientific).
-
bioRxiv - Genomics 2020Quote: ... Vitrified specimens were prepared by adding 4 μl disome samples at the concentration of ~ 150 nM to a glow-discharged holey carbon grid (Quantifoil R1.2/1.3), which was covered with a freshly made thin carbon film ...
-
bioRxiv - Cell Biology 2020Quote: ... The MEFs were applied onto glow-discharged EM grids with a silicon-oxide support film (R1/4, Au mesh; Quantifoil, Jena, Germany). After incubation ...
-
bioRxiv - Molecular Biology 2019Quote: 4 µL of 0.06 mg/mL crosslinked complex were applied to glow-discharged holey carbon grids (Quantifoil, QF 1.2/1.3, 300 mesh) covered with a 2 nm carbon layer ...
-
bioRxiv - Cell Biology 2022Quote: The cryo-EM grid was prepared by applying 3 μl of the protein samples (4 – 6 mg/ml) to glow-discharged Quantifoil R1.2/1.3 300-mesh gold holey carbon grids (Quantifoil, Micro Tools GmbH, Germany). Grids were blotted for 4.0 seconds under 100% humidity at 4°C before being plunged into the liquid ethane using a Mark IV Vitrobot (FEI) ...
-
bioRxiv - Cell Biology 2023Quote: ... Four µL of the cells were subsequently deposited onto Quantifoil R2/4 200 mesh copper grids (Quantifoil Micro Tools GmbH, Jena, Germany), which were then manually blotted from the back with Whatman® Grade 1 filter paper for approximately 3 – 5 seconds ...
-
bioRxiv - Biophysics 2023Quote: ... 4 μl suspended cells were loaded onto the front side of glow-discharged holy-carbon copper grids (Quantifoil R1.2/1.3, 200 mesh), and 2 μl medium was subsequently added to the back side of the grids ...
-
bioRxiv - Cell Biology 2024Quote: ... we micropatterned squares and circles varying from 5 to 30 μm across on 300 mesh gold grids coated with a thin perforated layer of silicon dioxide (Quantifoil R1/4). The grids were exposed to atmospheric plasma ...
-
bioRxiv - Cell Biology 2024Quote: ... the sample was gently resuspended and 4 µl was transferred to a glow-discharged holey carbon R2/1 copper grid (Quantifoil Micro Tools) suspended in the chamber of a Vitrobot (Thermo Fisher Scientific) ...
-
bioRxiv - Biochemistry 2020Quote: ... and 2 µL sample was applied to glow-discharged gold holey carbon 1.2/1.3 300-mesh grids (Quantifoil) coated in-house with graphene oxide55-57 ...
-
bioRxiv - Biochemistry 2021Quote: ... A volume of 2.5 μL of each sample was applied on glow-discharged UltrAuFoil Au300 Rl.2/1.3 grids (Quantifoil), and excess liquid was removed by blotting for 3 s (blot force 5 ...
-
bioRxiv - Biochemistry 2022Quote: ... 2 μl retromer at a concentration between 80-100 μg/ml was applied to freshly glow discharged CF-2/2-2C C-Flat grids (Protochips, Morrisville, NC) or Quantifoil R 1.2/1.3 300 mesh copper grids (Quantifoil Micro Tools GmbH ...
-
bioRxiv - Plant Biology 2022Quote: ... 2 μL of sample solution was applied onto a holey carbon grid (Quantifoil R2/1, Cu 300 mesh) covered with a thin amorphous carbon film ...
-
bioRxiv - Microbiology 2022Quote: ... 3.5 μL of cell suspension was applied on glow-discharged copper or gold EM grids (R2/2, Quantifoil) and automatically back-blotted (Weiss et al 2017 ...
-
bioRxiv - Molecular Biology 2021Quote: ... 3 μl of the resultant mixture was applied to glow-discharged (EasiGlow Pelco) R2/2 Quantifoil grids (Quantifoil). Excess sample was blotted away with a FEI Vitrobot (IV ...
-
bioRxiv - Biochemistry 2019Quote: ... 0.05% Tween-20 were applied on a glow-discharged holey carbon grid (Quantifoil, QF 2/1, 300 mesh). Subsequently ...
-
bioRxiv - Molecular Biology 2019Quote: ... 3 μl of the sample at 2 mg/ml were applied to 300 mesh UltrAuFoil Holey Gold Films R1.2/1.3 (Quantifoil) that had been previously plasma cleaned in a 75% argon / 25% oxygen atmosphere at 15 Watts for 6 seconds using a Solarus plasma cleaner (Gatan ...
-
bioRxiv - Evolutionary Biology 2021Quote: Molybdenum R1.2/1.3 and R2/2 200-mesh grids with a holey carbon support film (Quantifoil, Jena, DE) were glow discharged for 40 s under high vacuum shortly before sample application ...
-
bioRxiv - Biochemistry 2021Quote: ... 2 uL of crystal slurry was applied to each side of a glow-discharged holey carbon grid (Quantifoil, R 2/1 200 mesh Cu ...
-
bioRxiv - Biochemistry 2021Quote: ... 2 uL of crystal slurry was applied to each side of a glow-discharged holey carbon grid (Quantifoil, R 1/4 300 mesh Cu ...
-
bioRxiv - Immunology 2021Quote: ... Then 3 μl of the protein mixture was applied to a Quantifoil-Cu-2/1-3C grid (Quantifoil) pretreated by glow-discharging at 15 mA for 1 min ...
-
bioRxiv - Biophysics 2020Quote: 3 µl of the toroid suspension were deposited onto a glow-discharged holey carbon grid (Quantifoil R2/2), blotted with a filter paper for 4 seconds ...
-
bioRxiv - Cell Biology 2020Quote: ... K735 apo and K772-ANP datasets were collected on untreated carbon/copper grids (Quantifoil R2/2 300 mesh). The grids used for the other 15 datasets were gold grids (UltrAuFoil R2/2 200 mesh) ...
-
bioRxiv - Biochemistry 2022Quote: ... were prepared by applying 3 μL of freshly prepared STC (1:2 dilution) to UltrAuFoil 300 mesh R1.2/1.3 holey grids (Quantifoil), glow-discharged for 60 s at 10 mA (Leica EM ACE200) ...
-
bioRxiv - Microbiology 2022Quote: Phage particles were negatively stained for 20 s with 2 % uranyl acetate on carbon-coated copper grids (Quantifoil) and observed at 100 kV on a Hitachi HT 7700 equipped with an AMT XR81B Peltier cooled CCD camera (8M pixel ...
-
bioRxiv - Microbiology 2023Quote: ... Phage particles were negatively stained for 20 seconds with 2% uranyl acetate on carbon-coated copper grids (Quantifoil) and observed at 100 kV on a Hitachi HT 7700 equipped with an AMT XR81B Peltier cooled CCD camera (8M pixel ...
-
bioRxiv - Microbiology 2022Quote: ... the amoebae (5×105 per well) were seeded onto EM gold finder grids (Au NH2 R2/2, Quantifoil) and incubated for 1 h ...
-
bioRxiv - Cell Biology 2022Quote: ... Cells were then seeded onto gold grids (either ‘UltrAuFoil’ 200 Au mesh, R2/2 gold film, or Quantifoil 300 Au mesh ...
-
bioRxiv - Plant Biology 2023Quote: ... H4 NCPs were applied to Quantifoil R2/1 200-mesh grids coated with 2 nm of carbon (Quantifoil). H4.VS were applied to unsupported Quantifoil R2/1 200-mesh grids (Quantifoil) ...
-
bioRxiv - Molecular Biology 2023Quote: ... 4 μl of KMN complex at 0.3 mg/ml supplemented with 0.003% Triton were applied to glow-discharged UltrAuFoil R2/2 grids (Quantifoil). Excess liquid was removed by blotting (3.5 s at blot force −3) ...
-
bioRxiv - Biochemistry 2023Quote: ... Differentiated U937 cells became adhesive and were seeded onto gold London Finder grids (Au H2 R2/2, Quantifoil) coated with vitronectin (25 µg/mL in 1xPBS ...
-
bioRxiv - Biochemistry 2021Quote: 3.5 µl protein solution containing 0.05 µM CUL4-NEDD8/ROC1/DDB1/DCAF1-CtD/Vprmus/SAMHD1 complex and 0.25 µM UBCH5C-ubiquitin conjugate (S4 A, B Fig) were applied to a 300 mesh Quantifoil R2/4 Cu/Rh holey carbon grid (Quantifoil Micro Tools GmbH) coated with an additional thin carbon film as sample support and stained with 2% uranyl acetate for initial characterisation ...
-
bioRxiv - Biochemistry 2022Quote: ... Spike trimer - Fab complexes (4 μl) were applied to the pre-glow-discharged holey carbon grids (Quantifoil grid, Cu 300 mesh, R1.2/1.3). The grids were then blotted for 2 seconds with filter paper in 100% relative humidity and 8 °C and plunged into the liquid ethane to freeze samples using FEI Vitrobot system (FEI).
-
bioRxiv - Molecular Biology 2022Quote: ... An aliquot of 4 μL protein sample of Spike protein was applied onto a glow-discharged 300 mesh grid (Quantifoil Au R1.2/1.3) and GraFuture™-RGO grid which was supported with a thin layer of RGO (reduced graphene oxide) ...
-
bioRxiv - Molecular Biology 2023Quote: ... a 4 µl sample of purified complex was applied to glow-discharged R2/1 300 mesh holey carbon copper grids (Quantifoil Micro Tools GmbH), using a conc ...
-
bioRxiv - Cell Biology 2023Quote: 4 ul of Nannochloropsis suspensions (4 x 107 cells mL−1) were pipetted onto a 300 mesh gold Quantifoil grid with 2um holes (Quantifoil Micro Tools, GmbH) and manually blotted from the opposite side in a Vitrobot Mark IV (ThermoFisher Scientific ...
-
bioRxiv - Biochemistry 2023Quote: 4 μL of Fcα–J–FcRL4 (0.3 mg/mL) were applied to glow-discharged holy-carbon gold grids (Quantifoil, R1.2/1.3, 300 mesh) or Ni-Ti grids (CryoMatrix ...
-
bioRxiv - Cell Biology 2019Quote: ... cells were grown on 200 mesh gold R2/2 London Finder Quantifoil grids (Quantifoil Micro Tools GmbH, Jena, Germany) added to the bottom of MatTek dishes ...
-
bioRxiv - Cell Biology 2020Quote: ... HeLa cells were grown for 24 h on holey carbon-covered gold EM grids (200 mesh, R2/2, Quantifoil), fed with oleic acid and induced with doxycycline for Fsp27-EGFP expression for an unrelated project ...
-
bioRxiv - Microbiology 2022Quote: ... 3 μl aliquots of the mixture was applied to R2/2 200 mesh copper Quantiofoil grids (Quantifoil Micro Tools) that were freshly glow discharged ...
-
bioRxiv - Biochemistry 2019Quote: ... 3 μl were applied onto freshly glow-discharged Quantifoil Cu/Rh R2/2 holey carbon 200 mesh grids (Quantifoil). The grids were blotted for 4 seconds with a blotting force of −15 ...
-
bioRxiv - Biophysics 2020Quote: Three microliters of purified HCoV-NL63 virions (4.5 mg/mL) were first applied to 300-mesh R2/1 + 2 nm C-film grids (Quantifoil) that had been glow-discharged for 15s PELCO easiGlow (TED PELLA ...
-
bioRxiv - Microbiology 2021Quote: ... 3 µl of sample were applied to a freshly glow-discharged Quantifoil Au R2/2 200 mesh grid (Quantifoil), blotted for 5.5-7.5 s (0.5 s drain time ...
-
bioRxiv - Microbiology 2021Quote: ... 3 µl of sample were applied to a freshly glow-discharged Quantifoil Au R2/2 200 mesh grid (Quantifoil), blotted for 3.5-7.5 s (0.5 s drain time ...
-
bioRxiv - Microbiology 2021Quote: ... and 5 µl of the mixture was placed onto freshly glow discharged holey carbon grids (R 2/1, Quantifoil) for 1 min ...
-
bioRxiv - Biochemistry 2019Quote: ... 4 μl of these samples were applied to glow discharged (2.2×10-1 mbar for 2×20sec) Quantifoil holey carbon grids (R2/1, 200 mesh, Quantifoil). The grids were plunge vitrified into a liquid ethane/propane mix using a Vitrobot Mark IV at 4 °C and 95% humidity ...
-
bioRxiv - Biophysics 2020Quote: Cryo-EM grids were prepared by applying freshly purified channel protein (~3.5 μl) to glow-discharged copper Quantifoil R2/2 holey carbon grids (Quantifoil), which were then blotted for 2 s with ~100% humidity and flash frozen in liquid ethane using FEI Vitrobot Mark IV (FEI) ...
-
bioRxiv - Molecular Biology 2019Quote: ... 0.05% Tween-20 was pre-applied on a glow-discharged holey carbon grid (Quantifoil, QF 2/1, 300 mesh) covered with a 2 nm carbon layer ...
-
bioRxiv - Cell Biology 2021Quote: ... cells were grown on 200 mesh gold R2/2 London Finder Quantifoil grids (Quantifoil Micro Tools GmbH, Jena, Germany). Prior to seeding cells ...
-
bioRxiv - Biophysics 2023Quote: ... using FluoSpheres (diameter of 1 μm) on gold Quantifoil grids (200 mesh, R 2/1, holey SiO2 film; Quantifoil Micro Tools GmbH ...