Labshake search
Citations for Quantifoil Micro Tools :
1 - 50 of 677 citations for 2 Methyl 4 piperidin 1 ylsulfonyl phenylboronic acid since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biophysics 2024Quote: ... 2-4 chameleon self-wicking grids (Quantifoil Active 300 mesh; Quantifoil) were loaded into the instrument and glow discharged for 40-45 seconds at 12 mA ...
-
bioRxiv - Biophysics 2024Quote: ... 2-4 chameleon self-wicking grids (Quantifoil Active 300 mesh; Quantifoil) were loaded into the instrument and glow discharged for 40-45 seconds at 12 mA ...
-
bioRxiv - Microbiology 2024Quote: ... 4 µl sample was applied onto Au R2/2 200 mesh (Quantifoil) grids ...
-
bioRxiv - Biochemistry 2024Quote: Grids for cryo-EM were prepared by applying 4 µL of sample on a glow-discharged Quantifoil 300 mesh Cu 2/1 grid (Quantifoil Micro Tools), blotting for 7.5 seconds ...
-
bioRxiv - Biochemistry 2023Quote: ... pristine graphene-coated R2/4 grids (Graphenea) were initially used for optimisation purposes but 2 nm formvar/amorphous carbon R2/2 grids (Quantifoil) were used for data collection ...
-
bioRxiv - Molecular Biology 2020Quote: The grids were prepared by applying 4 µL of each complex at ∼70 nM to 400 mesh holey carbon Quantifoil 2/2 grids (Quantifoil Micro Tools). The grids were blotted for 1.5 sec at 4°C ...
-
bioRxiv - Neuroscience 2020Quote: ... covered with either 2 nm amorphous carbon (Quantifoil, R2/1+2 nm C) or graphene were used for sample preparation ...
-
bioRxiv - Molecular Biology 2020Quote: ... 4 μl sample was applied onto Quantifoil grid Rh/Cu 200 R2/2 (Quantifoil, Inc), and was flash frozen into liquid ethane using a Vitrobot (FEI ...
-
bioRxiv - Cell Biology 2021Quote: ... 4 µl sample was applied onto Quantifoil grid Cu/Rh 200 R2/2 (Quantifoil, Inc), and was flash frozen into liquid ethane using a Vitrobot (FEI ...
-
bioRxiv - Molecular Biology 2024Quote: A QuantiFoil 200-mesh R 2/1 grid with 2 nm continuous carbon (QuantiFoil Micro Tools GmbH ...
-
bioRxiv - Molecular Biology 2021Quote: ... 3.5 μL was applied to a glow-discharged Quantifoil copper grid with 2 nm continuous carbon support over holes (Quantifoil R 2/4 400 mesh), blotted ...
-
bioRxiv - Cell Biology 2024Quote: EM support grids (Au grids 200 mesh, carbon or SiO2 foil, R2/2 or R1/4, Quantifoil) were glow discharged with a Pelco easiGlow for 90 sec at 15 mA ...
-
bioRxiv - Cell Biology 2024Quote: ... with holey R 1/4 carbon film (Quantifoil Micro Tools GmbH) were glow-discharged for 30 seconds at 5 mA using an EasiGlow system (Pelco ...
-
bioRxiv - Molecular Biology 2020Quote: QUANTIFOIL R 2/1 grids with the 2-nm carbon layer (Cu 200, Quantifoil Micro Tools) were glow discharged with 25 mA with negative polarity for 60 s in a PELCO easiGlow glow discharge unit ...
-
bioRxiv - Microbiology 2024Quote: ... copper EM grids (Cu 200 R 2/1, Quantifoil) were used ...
-
bioRxiv - Microbiology 2024Quote: ... 4 µl of the concentrated cells were then spotted onto a glow discharged copper grid (R2/2, Quantifoil). By using a Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Plant Biology 2020Quote: ... 4 μL of cell culture was blotted onto R 1/4 SiO2-coated 200-mesh gold EM grids (Quantifoil Micro Tools) and plunge frozen in a liquid ethane/propane mixture ...
-
bioRxiv - Microbiology 2023Quote: ... Gold grids with SiO2 film (Quantifoil, Au 200 mesh, R 1/4) were glow- discharged and coated with 20 µg/ml fibronectin solution for 30 min ...
-
bioRxiv - Biophysics 2024Quote: ... 2 μL of 2 μM taxol-microtubules were incubated on a glow-discharged holey carbon cryo-EM grid (QuantiFoil, Cu 300 R 2/1) for 30 seconds ...
-
bioRxiv - Biophysics 2021Quote: ... 4 µl of this mixture was applied on a glow-discharged Quantifoil R2/2 grid (Quantifoil Micro Tools GmbH) and flash-frozen in liquid ethane using a Vitrobot Mark II device (FEI) ...
-
bioRxiv - Microbiology 2024Quote: ... 4 μL of the cell mixture was applied three times onto glow-discharged copper EM grids (R2/2, Quantifoil), followed by plunge freezing into liquid ethane/propane ...
-
bioRxiv - Biophysics 2024Quote: ... 4 µL of resuspended solution was applied to freshly glow-discharged Quantifoil R2/2 mesh 300 gold grids (Quantifoil) in a Vitrobot IV (ThermoFisher ...
-
bioRxiv - Cell Biology 2024Quote: EM grids (Quantifoil R 1/4 Au 200 mesh, Quantifoil Micro Tools GmbH) were glow discharged with an Edwards S150B glow discharger at 30mA for 45sec on both sides of the grid ...
-
bioRxiv - Cell Biology 2024Quote: 4 µl of yeast cells were pipetted on Cu R2/1 grids (Quantifoil), blotted manually from the backside of the grid for ∼4 s and plunge frozen in liquid ethane using a manual plunger ...
-
bioRxiv - Cell Biology 2021Quote: R 2/1 Holey Carbon Au 200 mesh EM grids (Quantifoil) were coated with approximately 20 nm of carbon in a MED 020 carbon coater (BAL-TEC ...
-
bioRxiv - Molecular Biology 2022Quote: ... The plus carbon sample (Quantifoil Cu300 R2/1 + 2 nm C) was blotted for 2 s with blot force +3 after a 30 s wait time after sample application and immediately plunge frozen in liquid ethane ...
-
bioRxiv - Biophysics 2021Quote: 4 µL of purified HsPepT1 at 2 mg/mL was applied to a glow discharged gold holey carbon 2/1 300-mesh grid (Quantifoil). The grid was blotted for 4 s at 0 force before being plunge vitrified in liquid propane using a Mark IV Vitrobot (ThermoFisher) ...
-
bioRxiv - Microbiology 2021Quote: ... 4-7 µl of cells were deposited on R2/1 Cu 200 grids (Quantifoil) that had been glow-discharged for 1 min at 0.19 mbar and 20 mA in a PELCO easiGlow device shortly before use ...
-
bioRxiv - Cell Biology 2020Quote: Gold EM grids with Quantifoil R 2/1 holey carbon film (Quantifoil Micro Tools GmbH ...
-
bioRxiv - Immunology 2021Quote: ... and Quantifoil R 2/1 (Cu, 400-mesh; Quantifoil Micro Tools GmbH). The grids were treated with Ar/O2 plasma (Solarus plasma cleaner ...
-
bioRxiv - Immunology 2024Quote: ... and Quantifoil R 2/1 (Cu, 400-mesh; Quantifoil Micro Tools GmbH) were used for freezing ...
-
bioRxiv - Biophysics 2024Quote: ... samples that have been analyzed here are Influenza A/Hong Kong/1/1968 virions that are produced from MDCK cells grown directly on cryoEM grids (QF AU200 R 2/2, Quantifoil, Germany), infected at a multiplicity of infection <1 ...
-
bioRxiv - Molecular Biology 2020Quote: ... plain grids (Quantifoil 2/2) were transferred to the microscope ...
-
Genome modularization reveals overlapped gene topology is necessary for efficient viral reproductionbioRxiv - Synthetic Biology 2020Quote: A 4 μL solution of co-isolated small particles were applied to glow-discharged copper grids (Quantifoil R2/2, Quantifoil Micro Tools), blotting for 3-seconds at 4 °C with 90% humidity and plunging into liquid ethane using a Lecia EM GP device (Leica Microsystems ...
-
Genome modularization reveals overlapped gene topology is necessary for efficient viral reproductionbioRxiv - Synthetic Biology 2020Quote: A 4 μL solution of co-isolated small particles were applied to glow-discharged copper grids (Quantifoil R2/2, Quantifoil Micro Tools), blotting for 3-seconds at 4 °C with 90% humidity and plunging into liquid ethane using a Lecia EM GP device (Leica Microsystems ...
-
Mycobacteria form viable cell wall-deficient cells that are undetectable by conventional diagnosticsbioRxiv - Microbiology 2022Quote: ... of which 3-4 µL was applied on glow-discharged 200 mesh copper grids with an extra thick R2/2 carbon film (Quantifoil Micro Tools). Vitrification was performed using an automated Leica EM GP plunge-freezer ...
-
bioRxiv - Biophysics 2021Quote: ... 4 μl of cell suspension was applied to holey carbon R2/1 Cu grids (Quantifoil) and plunge-frozen on a Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Cell Biology 2024Quote: Quantifoil R2/1 or SiO2 R1/4 gold grids (both Quantifoil Mirco Tools GmbH, Germany) were briefly washed in chloroform and placed on drops of poly-D-lysine (100 µg/ml) ...
-
bioRxiv - Biochemistry 2024Quote: ... carbon-coated (Quantifoil R 2/2) 200-mesh copper grids (Electron Microscopy Sciences ...
-
bioRxiv - Plant Biology 2020Quote: ... holey carbon-coated copper grids (R 2/1, 200 mesh, Quantifoil Micro Tools). Grids were plunge-frozen in a liquid ethane/propane mixture using a Vitrobot Mark 4 (FEI ...
-
bioRxiv - Neuroscience 2022Quote: Holey gold EM grids (Quantifoil R 2/1, 200 mesh; Quantifoil, Jena, Germany) were plasma cleaned in a Turbo Sputter Coater Med 010 (Balzers ...
-
bioRxiv - Biochemistry 2023Quote: Quantifoil™ R 2/1 on 200 copper mesh (Quantifoil Micro Tools GmbH) were used immediately after glow discharging in a glow discharge cleaning system (PELCO easiGlow ...
-
bioRxiv - Biophysics 2023Quote: ... using FluoSpheres (diameter of 1 μm) on gold Quantifoil grids (200 mesh, R 2/1, holey SiO2 film; Quantifoil Micro Tools GmbH ...
-
bioRxiv - Molecular Biology 2024Quote: ... 4 µl of the sample was applied onto freshly glow-discharged R2/1 carbon grids (Quantifoil), followed by grid blotting for 4 s and plunging into liquid ethane using a Vitrobot Mark IV (FEI ...
-
bioRxiv - Biochemistry 2022Quote: ... holey copper grids (QUANTIFOIL R 2/2). 3.5-μl samples were adsorbed for 1 min at +20 °C ...
-
bioRxiv - Microbiology 2020Quote: Holey carbon-coated (R 2/2; Quantifoil) Au-G200F1 grids were analyzed in cryo-conditions by MISTRAL microscope at ALBA synchrotron ...
-
bioRxiv - Molecular Biology 2021Quote: ... 4 μl of protein sample (about 0.73 mg/ml) was applied onto a glow-discharged holey carbon grid (Quantifoil Au, R2/2, 300 mesh). After blotting for 3 s ...
-
bioRxiv - Biophysics 2021Quote: ... was applied to glow discharged gold holey carbon 2/1 300-mesh grids (Quantifoil). Grids were blotted for 4 s at 0 force and 2 s wait time before being plunge vitrified in liquid propane using a MarkIV Vitrobot (ThermoFisher) ...
-
bioRxiv - Cell Biology 2020Quote: ... Quantifoil R2/2 or R3.5/1 200 mesh Au grids with carbon film (Quantifoil) were coated with 0.01% poly-L-ornithine solution (Sigma Aldrich ...
-
bioRxiv - Molecular Biology 2021Quote: QUANTIFOIL R 2/1 grids with 2nm carbon layer (Cu 200, Quantifoil Micro Tools) were glow discharged with 25 mA with negative polarity for 60 seconds in a PELCO easiGlow glow discharge unit ...