Labshake search
Citations for Quantifoil Micro Tools :
251 - 300 of 611 citations for 1 2 2 morpholin 4 ium 4 ylethoxy phenyl butan 1 one chloride since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biophysics 2023Quote: 4 μL purified protein was placed on the holy-carbon grids (Quantifoil Au R1.2/1.3, 300 mesh), which were glow-discharged for 30 s ...
-
bioRxiv - Biophysics 2023Quote: ... 4 µL fresh sample was applied on glow-discharged Cu holey carbon grids (Quantifoil R 1.2/1.3) and incubated for 1 min at room temperature ...
-
bioRxiv - Biophysics 2019Quote: Samples for cryo-EM were prepared by applying 4 µl of purified TRPA1 to 1.2/1.3 holey carbon grids (Quantifoil) and blotting for 8-12 sec ...
-
bioRxiv - Biophysics 2021Quote: ... 4 µL of aldolase sample were applied on UltrAuFoil R1.2/1.3 300-mesh grids (Quantifoil Micro Tools GmbH) that had been freshly plasma cleaned for 6 seconds at 15 Watts (75% nitrogen/25% oxygen atmosphere ...
-
bioRxiv - Biophysics 2021Quote: ... 4 µL of apoferritin sample were applied on UltrAuFoil R1.2/1.3 300-mesh grids (Quantifoil Micro Tools GmbH) that had been freshly plasma cleaned for 7 seconds at 15 Watts (75% nitrogen/25% oxygen atmosphere ...
-
bioRxiv - Biophysics 2021Quote: The LlCsm RNP and RNP-target RNA samples at approximately 0.5 mg/ml were separately applied in 4 μL volume onto glow-discharged UltrAuFoil 300 mesh R1.2/1.3 grids (Quantifoil), blotted for 3 s at 88% humidity and flash-frozen in liquid ethane using FEI Vitrobot Mark IV ...
-
bioRxiv - Molecular Biology 2022Quote: ... for 15 min before 4 μL of sample was applied to a graphene oxide coated 1.2/1.3 UltrAuFoil grids (Quantifoil) at 4°C under 100% humidity86 ...
-
bioRxiv - Microbiology 2022Quote: ... Aliquots of 4 μL samples were applied to glow-discharged holey carbon girds (Cu, R1.2/1.3, 300 mesh, Quantifoil). The grids were blotted with force 2 for 3 seconds and plunged into liquid ethane using a Vitrobot (FEI Thermo Fisher) ...
-
bioRxiv - Molecular Biology 2024Quote: ... The peak fraction was then diluted with buffer N to 0.8 mg ml-1 and cryoEM grids prepared by applying 4 µl of the sample to glow-discharged Cu R1.2/1.3 300-mesh holey carbon grids (Quantifoil). Grids were prepared blotted at 8 °C and 90% humidity and plunged into liquid ethane using a Leica EM GP2.
-
bioRxiv - Biochemistry 2020Quote: Quantifoil R2/2 300 mesh holey carbon copper grids (Quantifoil Micro Tools, Großlöbichau, Germany) were glow-discharged (ELMO Glow Discharge System ...
-
bioRxiv - Biophysics 2020Quote: ... and applied 3 μL to glow discharged EM grids (Quantifoil R2/2 400 mesh). The GFP portion of this substrate consisted of residues 1-229 ...
-
bioRxiv - Cell Biology 2022Quote: MEF were seeded on R2/2 holey carbon on gold grids (Quantifoil or Protochips) coated with fibronectin in a glass bottom dish (Mattek or Ibidi ...
-
bioRxiv - Cell Biology 2022Quote: ... The cells were seeded on EM grids (Quantifoil SiO2 R2/2, 200 mesh, gold) in a 3D printed specimen holder [43] and grown overnight.
-
bioRxiv - Molecular Biology 2022Quote: ... 2–3 μL of sample solution was applied to a holey carbon grid (Quantifoil R2/1 ...
-
bioRxiv - Biochemistry 2023Quote: ... Quantifoil R2/2 Cu 400 mesh holey carbon grids (Quantifoil Micro Tools, Jena, Germany) coated with a 0.4 mg/ml graphene oxide suspension (Sigma-Aldrich ...
-
bioRxiv - Molecular Biology 2023Quote: ... Quantifoil R1.2/1.3 400-square mesh Cu grids with 2 nm continuous carbon (Quantifoil) were glow-discharged for 8 s at 10 mA using a PELCO easiGlow glow discharging system (Ted Pella ...
-
bioRxiv - Biochemistry 2024Quote: ... Three microliters of sample were applied to glow-discharged R2/2 carbon grids (Quantifoil), which were blored for 5 s and at a blot force of 25 and plunge-frozen in liquid ethane with a Vitrobot Mark IV (ThermoFisher ...
-
bioRxiv - Biochemistry 2020Quote: ... KBP was diluted to 0.3 mg/ml in KBP dilution buffer and 4 μl were applied to glow-discharged 1.2/1.3 AuFoil gold grids (Quantifoil®). For the third approach ...
-
bioRxiv - Molecular Biology 2019Quote: The concentration of the core BBSome as derived from chemical crosslinking was adjusted to 0.05-0.08 mg/ml and 4 μl of sample was immediately applied to a glow-discharged UltrAuFoil® R1.2/1.3 holey gold grid (Quantifoil). After two minutes incubation at 13 °C and 100% relative humidity (RH) ...
-
bioRxiv - Microbiology 2022Quote: ... A 4□μl volume of SsoCsm complex was applied to holey carbon grids (Quantifoil Cu R1.2/1.3, 300 mesh) covered by a graphene oxide layer (27) ...
-
bioRxiv - Molecular Biology 2021Quote: ... and applied onto freshly glow-discharged 200 square mesh Ultrafoil R2/2 gold grids (Quantifoil). The samples were plunge-frozen with a FEI Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Microbiology 2021Quote: ... Freshly glow-discharged finder gold quantifoil grids (200 mesh R2/2 – Quantifoil MicroTools GmbH, Germany) were sterilized in 70% EtOH and placed in a glass-bottomed MatTek dish (MatTek Corporation ...
-
bioRxiv - Microbiology 2021Quote: ... were applied to freshly washed and glow-discharged R2/2 holey carbon copper grids (Quantifoil). The grids were manually back blotted for 2 to 3s with filter paper ...
-
bioRxiv - Biochemistry 2021Quote: ... Cryo-EM grids were prepared using glow discharged R2/2 Cu 200 mesh grids (Quantifoil) pre-floated onto custom-made 2.9 nm continuous carbon film ...
-
bioRxiv - Microbiology 2023Quote: ... sample aliquots of 3 µL were applied onto UltrAuFoil R2/2 grids (300 mesh, Quantifoil). Grids were blotted for 1 s at 10°C with 100% relative humidity and immediately plunge frozen into liquid ethane using a Vitrobot Mark IV system (TFS) ...
-
bioRxiv - Molecular Biology 2023Quote: ... 3.5 μL) were applied to precoated (2 nm) R1.2/1.3 carbon-supported copper grids (Quantifoil), blotted for 4-5 s at 4°C ...
-
bioRxiv - Biophysics 2022Quote: 3.5 μl of protein samples at 4-6 mg/ml were applied to glow-discharged QF R1.2/1.3 300 mesh gold grids (Quantifoil, Großlöbichau, Germany). Grids were blotted for 3 s at 4°C and 100% humidity and plunge-frozen into liquid ethane using FEI Mark IV Vitrobot (FEI ...
-
bioRxiv - Plant Biology 2022Quote: ... then 4 µl of the sample was applied to glow-discharged holey carbon grids (Quantifoil Cu R1.2/1.3, 300 mesh). The grid was blotted for 4s and then plunged into liquid ethane using a Vitrobot Mark IV (FEI ...
-
bioRxiv - Molecular Biology 2023Quote: 1.8 × 105 A549 or A549-IFITM3 cells were seeded on glow-discharged 200 mesh gold grids with a holey SiO2 film with R1/4 spacing (Quantifoil) placed in a 35 mm dish and cultured in 2 ml complete growth medium (DMEM-F12 ...
-
bioRxiv - Biochemistry 2023Quote: ... 4 μL of Fcμ–J–CD5L was applied to glow-discharged holy-carbon gold grids (Quantifoil, R1.2/1.3, 300 mesh), blotted with filter paper in 100% humidity at 4 °C ...
-
bioRxiv - Cell Biology 2024Quote: ... 4 μl of the cell suspension was applied onto a glow-discharged holey SiO2 grid (R1/4, Au, 200 mesh, Quantifoil) mounted on in the plunger chamber ...
-
bioRxiv - Microbiology 2021Quote: ... 3μl was added to a glow-discharged R2/2 200 mesh holey carbon EM grid (Quantifoil) for 30 seconds and the sample was blotted for 1 second ...
-
bioRxiv - Cell Biology 2022Quote: ... A volume of 2.5 μL was applied on glow-discharged UltrAuFoil Au200 R2/2 grids (Quantifoil), and excess liquid was removed by blotting for 3 s (blot force 5 ...
-
bioRxiv - Biochemistry 2022Quote: ... 3 µL of purified PPSA was applied to glow-discharged holy grids (Quantifoil, Cu200, R2/2) for 30s ...
-
bioRxiv - Biochemistry 2023Quote: The final high resolution data set was collected across 2 grids (Quantifoil 1.2/1.3 200 mesh) prepared with 1.8 mg mL-1 trimeric complex and 0.5 and 0.1 X CMC CHAPS ...
-
bioRxiv - Molecular Biology 2023Quote: ... Quantifoil R1.2/1.3 400-square mesh copper grids with a 2 nm continuous carbon layer (Quantifoil) were plasma-treated in a Pelco easiGlow glow discharging system (Ted Pella ...
-
bioRxiv - Microbiology 2021Quote: ... Aliquots (4 μL) of the protein complex were placed on glow-discharged holey carbon grids (Quantifoil Au R1.2/1.3, 300 mesh). The grids were blotted and flash-frozen in liquid ethane cooled by liquid nitrogen with a Vitrobot apparatus (Mark IV ...
-
bioRxiv - Microbiology 2020Quote: Three μl of purified HKU1 HE (4 mg/ml) was dispensed on Quantifoil R1.2/1.3 200-mesh grids (Quantifoil Micro Tools GmbH) that had been freshly glow discharged for 30 seconds at 20 mA using GloQube Glow Discharge system (Quorum Technologies) ...
-
bioRxiv - Molecular Biology 2022Quote: ... 4 μL of protein samples were immediately applied to discharged 300-mesh Au R1.2/1.3 grids (Quantifoil, Micro Tools GmbH, Germany). Grids were blotted for 4 s and plunged into liquid ethane using an FEI Mark IV Vitrobot operated at 8°C and 100% humidity ...
-
bioRxiv - Molecular Biology 2022Quote: ... 4 μL of the cells were applied to a glow-discharged 200 mesh holey carbon grid copper grid (Quantifoil R1.2/3) and vitrified in a liquid ethane on a Vitrobot Mark IV (Thermo Scientific ...
-
bioRxiv - Cell Biology 2023Quote: ... 4 μl of the sample was applied to glow discharged holey carbon-coated 200 mesh copper EM grids (Quantifoil Micro Tools), vitrified as above at 4°C and 100 % humidity.
-
bioRxiv - Biochemistry 2021Quote: Three microliters of the h20S-PA26E102A-Opt5 solution were applied to R2/2 400-mesh grids (Quantifoil) that had been plasma treated for 25 s using a glow discharger (Electron Microscopy Sciences ...
-
bioRxiv - Molecular Biology 2022Quote: ... 3.5 μL was applied to freshly glow-discharged Quantifoil R2/2 300-square-mesh gold grids (Quantifoil) in a Vitrobot IV (ThermoFisher ...
-
bioRxiv - Biophysics 2020Quote: ... 2 μl apoferritin was applied to glow-discharged gold holey carbon 1.2/1.3 300-mesh grids (Quantifoil). Grids were blotted for 4 seconds at -2 force and vitrified in liquid ethane using a MarkIV Vitrobot (ThermoFisher) ...
-
bioRxiv - Molecular Biology 2023Quote: ... 3.5 μL was applied to freshly glow discharged Quantifoil R2/2 300-square-mesh gold grids (Quantifoil) in a Vitrobot IV (ThermoFisher ...
-
bioRxiv - Microbiology 2023Quote: ... The samples were applied to a Quantifoil R2/2 Cu 300 mesh grid (Quantifoil Micro Tools GmbH), which had been freshly glow-discharged for 60 s at 10 mA using PIB-10 (Vacuum Device) ...
-
bioRxiv - Bioengineering 2022Quote: ... holey carbon grids (Quantifoil R2/1 grid: Cu 300mesh, M2951C-1-300) were hydrophilized by a JEC-3000FC Auto Fine Coater (JEOL ...
-
bioRxiv - Molecular Biology 2021Quote: ... bremelanotide– or THIQ–bound MC4R–Gs complexes at ∼ 4 mg/mL were applied onto glow-discharged holey carbon grids (Quantifoil R1.2/1.3). Excess samples were blotted away and the grids were vitrified by plunging into liquid ethane using a Vitrobot Mark IV (ThermoFischer Scientific).
-
bioRxiv - Genomics 2020Quote: ... Vitrified specimens were prepared by adding 4 μl disome samples at the concentration of ~ 150 nM to a glow-discharged holey carbon grid (Quantifoil R1.2/1.3), which was covered with a freshly made thin carbon film ...
-
bioRxiv - Cell Biology 2020Quote: ... The MEFs were applied onto glow-discharged EM grids with a silicon-oxide support film (R1/4, Au mesh; Quantifoil, Jena, Germany). After incubation ...