Labshake search
Citations for Quantifoil Micro Tools :
351 - 400 of 485 citations for Glyphosate Chemical Purity 96% 2 13C 99%; 15N 98%+ 1000 Ug Ml In Water since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Microbiology 2023Quote: ... 2.2µl of the purified mixture at a concentration of 0.5 mg/mL was applied to glow discharged (30 s at 25mA) grid (300 mesh 1.2/1.3, Quantifoil). The grids were blotted for 3.5 s before plunging into liquid ethane using Vitrobot MK4 (TFS ...
-
bioRxiv - Immunology 2023Quote: ... 3 μL of the purified complex (8 mg/ml) was deposited onto a glow-discharged holey grid (Quantifoil Au 300 mesh R1.2/1.3 ...
-
bioRxiv - Cell Biology 2020Quote: 4 µl of the cultured yeast cells (OD600 of 0.4) were added to a glow-discharged (30 seconds at -30 mA) copper R2/2 holey carbon grid (Quantifoil Micro Tools GmbH, Jena, Germany), then the grid was rapidly plunge frozen in liquid ethane using a homemade plunge freezer and stored in liquid nitrogen until used ...
-
bioRxiv - Biophysics 2022Quote: ... an aliquot of 3 μL of sample was applied onto a glow-discharged holey carbon-coated copper grid (300 mesh, QUANTIFOIL® R 2/1) or holey gold grid (300 mesh ...
-
bioRxiv - Cell Biology 2022Quote: ... 4 µL of the mixture were pipetted onto a copper EM grid with holey carbon film (R2/2, 200 mesh, Quantifoil Micro Tools GmbH, Q43486) that had been freshly glow-discharged for 30 s at -30 mAmp ...
-
bioRxiv - Biophysics 2021Quote: ... A volume of 4 μL cell suspension at a concentration of 3.07-3.5×107 cells/ml was directly applied to glow-discharged holey carbon R2/1 Cu 200 mesh grids (Quantifoil). After 5 s back-side blotting ...
-
bioRxiv - Biophysics 2020Quote: ... This sample was blotted once (3.5 mL per blot) onto glow discharged 200 mesh Quantifoil 1.2/1.3 grids (Quantifoil Micro Tools) at 4°C and 100% humidity and plunge frozen in liquid ethane cooled to the temperature of liquid nitrogen (Thermo Fisher Vitrobot Mark IV) ...
-
bioRxiv - Biochemistry 2019Quote: ... 3 μl of ∼0.06 mg/ml TorsinA polymers were applied to glow-discharged Quantifoil R1.2/1.3 400 mesh Cu holey carbon grids (Quantifoil, Germany), blotted (8 seconds ...
-
bioRxiv - Molecular Biology 2020Quote: ... 4 μl of purified PA7LF3 at a concentration of ∼0.06 mg/ml was applied onto freshly glow discharged grids (Quantifoil R 1.2/1.3 holey carbon with a 2 nm additional carbon support ...
-
bioRxiv - Biophysics 2021Quote: The ScBfr sample at concentration of 1.8 mg/ml was blotted (3.5□μl per blot) onto Au 300 mesh Quantifoil 1.2/1.3 grids (Quantifoil Micro Tools), and immediately plunge frozen using a Vitrobot (FEI) ...
-
bioRxiv - Microbiology 2022Quote: ... Purified BfpD was diluted to 4.5 mg/ml and 3 µl was applied to a glow-discharged 300 mesh UltraAufoil -1.2/1.3 holey-gold (Quantifoil, Germany). Grids were blotted for 2 s with ash-free Whatman® Grade 540 filter paper in a Vitrobot Mark IV (ThermoFisher Scientific ...
-
bioRxiv - Biophysics 2022Quote: Eleven cryoEM grids were prepared by two people by adding 3 μL of mouse apoferritin (mApof, from Dr. Kikkawa’s lab) solution (8 mg/mL) to UltrAuFoil 1.2/1.3 grids (Quantifoil, Jena, Germany) immediately after plasma cleaning (Gatan Solarus II plasma cleaner ...
-
bioRxiv - Neuroscience 2023Quote: ... Double application of 3 µL protein (∼0.6 mg/mL) SYM2081 complex was carried out on glow-discharged gold grids (R 0.6/1, 300 mesh, Quantifoil). The grids were blotted for 4.5 s and 3.5 s ...
-
bioRxiv - Biophysics 2023Quote: ... 3 μL HA trimer (0.75 mg/ml) was applied to holey carbon grid (Quantifoil 400 mesh Au R1.2/1.3) which was glow discharged 30 s at 15 mA ...
-
bioRxiv - Biophysics 2023Quote: ... 3 μL apoferritin (0.67 mg/ml) was loaded on the holey carbon grids (Quantifoil 400 mesh Cu R1.2/1.3) which was glow discharged for 30s ...
-
bioRxiv - Biophysics 2023Quote: ... 3 μL HA trimer (0.75 mg/ml) was applied to holey carbon grid (Quantifoil 400 mesh Cu R1.2/1.3) which was glow discharged 30 s at 15 mA ...
-
bioRxiv - Microbiology 2023Quote: ... 3 μL of 3 mg/mL of protein was added to glow discharged UltrAuFoil holey gold grid (Quantifoil GmbH) using a Vitrobot Mark IV (Thermofisher ...
-
Molecular insights into the atypical activation mechanism of GPR156 in maintaining auditory functionbioRxiv - Molecular Biology 2024Quote: ... Gi3-bound: 4.5 mg/ml) was applied onto the glow-discharged holey carbon grids (Quantifoil, R1.2/1.3, 300 mesh). The grids were blotted for 3.0 s with a blot force of 10 at 4 ℃ ...
-
bioRxiv - Microbiology 2020Quote: ... A small volume (4 µL) of cells was then transferred onto freshly glow‐discharged copper R2/2 200 Quantifoil holey carbon grids (Quantifoil Micro Tools GmbH, Jena, Germany). Grids were then blotted and plunge‐frozen in a liquid ethane/propane mixture 31 using an FEI Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Biochemistry 2022Quote: ... Samples were prepared by depositing 3 μl of the crystalline slurry onto a glow-discharged EM grid (Quantifoil, Cu 200 mesh, R2/2 holey carbon). Excess liquid was blotted away and the sample was vitrified using a Leica GP2 vitrification robot ...
-
bioRxiv - Molecular Biology 2022Quote: 3 μL of ~120 nM mitoribosome was applied onto a glow-discharged (20 mA for 30 sec) holey-carbon grid (Quantifoil R2/2, copper, mesh 300) coated with continuous carbon (of ~3 nm thickness ...
-
bioRxiv - Cell Biology 2019Quote: ... 4 µl of the solution was applied to a glow-discharged (30 s at −35 mA) copper R2/2 holey carbon grid (Quantifoil Micro Tools GmbH, Jena, Germany). After removing excess liquid by blotting the grid from the back side with Whatman filter paper No ...
-
bioRxiv - Microbiology 2019Quote: ... Four μl of this mixture was applied onto freshly glow-discharged copper R2/2 of th0 Quantifoil holey carbon grids (Quantifoil Micro Tools GmbH, Jena, Germany). Using an FEI Vitrobot Mark IV ...
-
bioRxiv - Biophysics 2020Quote: ... 2 μL of a 1 in 6 dilution of the batch crystallisation was applied to the carbon side of glow discharged R2/2 Quantifoil™ grids (Quantifoil Micro Tools, Jena, Germany). Excess liquid was removed by blotting for 4-6 s with a Vitrobot (Thermo Fisher ...
-
bioRxiv - Microbiology 2020Quote: ... 3.5 μl of that mixture was transferred to a 3 mm freshly glow-discharged Quantifoil R2/2 Cu 300 mesh holey carbon grid (Quantifoil Micro Tools GmbH, Jena, Germany). Excess liquid was blotted away using a Leica EM GP plunge-freezer at room temperature and 80% humidity (blot time 2-3 sec ...
-
bioRxiv - Molecular Biology 2022Quote: ... The pellet was then resuspended in warm EM buffer and 3 μL of this sample was applied to a carbon on gold grid (Quantifoil R2/2 Au 200 mesh), recently glow-discharged for 1 min at 30 mA ...
-
bioRxiv - Biochemistry 2022Quote: ... The endogenous samples were applied onto grids containing an additional thin layer of continuous carbon support (Quantifoil R1.2/1.3 Cu 200 mesh + 2 nm C) and incubated for 30 sec before blotting and freezing ...
-
bioRxiv - Biochemistry 2023Quote: 3 μL of ∼120 nM mitoribosome was applied onto a glow-discharged (20 mA for 30 sec) holey- carbon grid (Quantifoil R2/2, copper, mesh 300) coated with continuous carbon (of ∼3 nm thickness ...
-
bioRxiv - Biophysics 2023Quote: ... 4 μl of the extracellular parasites were pipetted onto a glow-discharged (30 seconds at −30 mA) copper R2/2 holey carbon grid (Quantifoil Micro Tools GmbH, Jena, Germany). Samples were back-blotted with a Whatman filter paper (grade 1 ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... a volume of 6-8 μL of each sample was applied onto a gold grid covered by a holey gold film (UltrAuFoil 2/1, Quantifoil Micro Tools GmbH, Jena, Germany). Excess of liquid was blotted automatically between two strips of filter paper or only from the backside of the Grid ...
-
bioRxiv - Biochemistry 2023Quote: ... 3 μL of ∼120 nM mitoribosome was applied onto a glow-discharged (20 mA for 30 sec) holey-carbon grid (Quantifoil R2/2, copper, mesh 300) coated with continuous carbon (of ∼3 nm thickness ...
-
bioRxiv - Neuroscience 2024Quote: ... Supernatant after centrifugation mixed with 10-nm gold beads solution (Aurion, cat # 25486) at 1:1 ratio was added to the mounted grid (Quantifoil R2/2 Cu 200 EM). No other chemicals or stimulation were applied prior to plunge freezing ...
-
bioRxiv - Molecular Biology 2020Quote: ... or the purified apo complex sample at about 0.75mg/ml (combined with 0.5 µL of 0.025% DDM) was applied onto a glow-discharged holey carbon grid (Quantifoil R1.2/1.3), blotted ...
-
bioRxiv - Biochemistry 2020Quote: ... at ∼0.3 mg/ml was applied to a 1.2/1.3 Quantifoil grid with continuous carbon support (Quantifoil Micro Tools GmbH), which had been glow discharged for 60 s at 15 mA ...
-
bioRxiv - Biochemistry 2020Quote: ... 3.5 μl of the peak fraction from gel filtration chromatography at ~1.0 mg/ml was also applied to the glow discharged 1.2/1.3 Quantifoil grids (Quantifoil Micro Tools Gmb). Grids were immediately plunge-frozen in liquid ethane using a Vitrobot Mark IV (ThermoFisher Scientific) ...
-
bioRxiv - Biochemistry 2020Quote: ... 3.5 μl of the freshly purified G614 sample in NP-40 at ~0.3 mg/ml was applied to a 1.2/1.3 Quantifoil grid with continuous carbon support (Quantifoil Micro Tools GmbH), which had been glow discharged with a PELCO easiGlow™ Glow Discharge Cleaning system (Ted Pella ...
-
bioRxiv - Biochemistry 2021Quote: ... 3.5 μl of the freshly purified sample from the peak fraction in DDM at ~2.0 mg/ml for the B.1.1.7 protein or ~1.5 mg/ml for the B.1.351 protein was applied to a 1.2/1.3 Quantifoil grid (Quantifoil Micro Tools GmbH), which had been glow discharged with a PELCO easiGlow™ Glow Discharge Cleaning system (Ted Pella ...
-
bioRxiv - Biophysics 2020Quote: ... 3.5 μL at 2.5 mg/ml sample was directly applied to glow-discharged 200 mesh carbon grids (Quantifoil R1.2/1.3). Grids were immediately plunge-frozen in liquid ethane using a FEI Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Plant Biology 2022Quote: 3 μL of purified PSI complex at 1 mg Chl mL−1 were applied to glow-discharged (GloQube Quorum, 40 sec, 20mA) holey carbon grids (Quantifoil 300 Au R1.2/R1.3 ...
-
bioRxiv - Biochemistry 2022Quote: 3 µl of prepared complexes at a concentration of approximately 1 mg/ml was applied to a glow-discharged Quantifoil 300 mesh copper R1.2/1.3 grids (Quantifoil Micro Tools). The grids were then flash frozen in liquid ethane using a Thermo Fisher Scientific Vitrobot IV (0-0.5 s waiting time ...
-
bioRxiv - Biochemistry 2019Quote: ... 2.5μl (~0.1 mg/ml) was applied onto amino-functionalized graphene oxide holy carbon grids (Quantifoil 300 mesh Au R1.2/1.3). The grids were blotted by Whatman No ...
-
bioRxiv - Biochemistry 2020Quote: ... at 4.0 mg/ml and INT-777–GPBAR–Gs complex (3.0 μL) at 4.5 mg/ml were applied onto a glow-discharged holey carbon grid (Quantifoil R1.2/1.3), and subsequently vitrified using a Vitrobot Mark IV (Thermo Fischer Scientific) ...
-
bioRxiv - Biophysics 2022Quote: 3.5 μl of protein samples at 4-6 mg/ml were applied to glow-discharged QF R1.2/1.3 300 mesh gold grids (Quantifoil, Großlöbichau, Germany). Grids were blotted for 3 s at 4°C and 100% humidity and plunge-frozen into liquid ethane using FEI Mark IV Vitrobot (FEI ...
-
bioRxiv - Microbiology 2022Quote: ... the purified full-length BA.2 spike protein at 4.6 mg/ml in DDM was applied to a 1.2/1.3 Quantifoil gold grid (Quantifoil Micro Tools GmbH), which had been glow discharged with a PELCO easiGlow™ Glow Discharge Cleaning system (Ted Pella ...
-
bioRxiv - Cell Biology 2023Quote: 3 µl of prepared complexes at a concentration of approximately 1 mg/mL was applied to UltrAuFoil 300 mesh gold R1.2/1.3 grids (Quantifoil Micro Tools), freshly glow discharged with an Edwards S150B glow discharger for 1 min 15 sec ...
-
bioRxiv - Microbiology 2023Quote: Cryo-EM grids were prepared by applying 3.5 μL of concentrated sample at 1.2 mg/mL to glow discharged 400 mesh R1.2/1.3 UltrAuFoil grids (Quantifoil Micro Tools GmbH). The sample was adsorbed for 30 s on the grids followed by plunge freezing in liquid ethane using a Vitrobot Mark IV plunge freezer (Thermo Fischer Scientific) ...
-
bioRxiv - Biochemistry 2023Quote: ... 3 μl of protein at a concentration of approximately 10 mg ml−1 were loaded onto glow-discharged holey carbon grids (Quantifoil Au 300 mesh R1.2/1.3 or Quantifoil Cu/Rh 300 mesh R1.2/1.3) ...
-
bioRxiv - Biochemistry 2022Quote: ... the postfusion S-nanodisc sample at 1.5 mg/ml was applied to a 1.2/1.3 Quantifoil gold grid (Quantifoil Micro Tools GmbH), which had been glow discharged with a PELCO easiGlow™ Glow Discharge Cleaning system (Ted Pella ...
-
bioRxiv - Biophysics 2023Quote: ... 3.5 μL of labeled GltPh protein (4.5 mg/mL) was applied to a glow-discharged QuantiFoil R1.2/1.3 300-mesh gold grid (Quantifoil Micro Tools GmbH) and incubated for 2 min under 100 % humidity at the desired temperatures ...
-
bioRxiv - Molecular Biology 2023Quote: Four μL of 0.5 mg/ml CRY:TIM solution was applied to glow-discharged grids (300 mesh Quantifoil Au, R1.2/1.3) that were purchased from Electron Microscopy Sciences ...