Labshake search
Citations for Quantifoil Micro Tools :
301 - 350 of 470 citations for 4 2 Trimethylsilyl Ethyl Aniline since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Molecular Biology 2021Quote: ... 3 μl of the resultant mixture was applied to glow-discharged (EasiGlow Pelco) R2/2 Quantifoil grids (Quantifoil). Excess sample was blotted away with a FEI Vitrobot (IV ...
-
bioRxiv - Evolutionary Biology 2021Quote: Molybdenum R1.2/1.3 and R2/2 200-mesh grids with a holey carbon support film (Quantifoil, Jena, DE) were glow discharged for 40 s under high vacuum shortly before sample application ...
-
bioRxiv - Biochemistry 2021Quote: ... 2 uL of crystal slurry was applied to each side of a glow-discharged holey carbon grid (Quantifoil, R 2/1 200 mesh Cu ...
-
bioRxiv - Biochemistry 2021Quote: ... 2 uL of crystal slurry was applied to each side of a glow-discharged holey carbon grid (Quantifoil, R 1/4 300 mesh Cu ...
-
bioRxiv - Immunology 2021Quote: ... Then 3 μl of the protein mixture was applied to a Quantifoil-Cu-2/1-3C grid (Quantifoil) pretreated by glow-discharging at 15 mA for 1 min ...
-
bioRxiv - Biophysics 2020Quote: 3 µl of the toroid suspension were deposited onto a glow-discharged holey carbon grid (Quantifoil R2/2), blotted with a filter paper for 4 seconds ...
-
bioRxiv - Cell Biology 2020Quote: ... K735 apo and K772-ANP datasets were collected on untreated carbon/copper grids (Quantifoil R2/2 300 mesh). The grids used for the other 15 datasets were gold grids (UltrAuFoil R2/2 200 mesh) ...
-
bioRxiv - Plant Biology 2023Quote: ... H4 NCPs were applied to Quantifoil R2/1 200-mesh grids coated with 2 nm of carbon (Quantifoil). H4.VS were applied to unsupported Quantifoil R2/1 200-mesh grids (Quantifoil) ...
-
bioRxiv - Molecular Biology 2023Quote: ... 4 μl of KMN complex at 0.3 mg/ml supplemented with 0.003% Triton were applied to glow-discharged UltrAuFoil R2/2 grids (Quantifoil). Excess liquid was removed by blotting (3.5 s at blot force −3) ...
-
bioRxiv - Cell Biology 2022Quote: ... Cells were then seeded onto gold grids (either ‘UltrAuFoil’ 200 Au mesh, R2/2 gold film, or Quantifoil 300 Au mesh ...
-
bioRxiv - Biochemistry 2022Quote: ... were prepared by applying 3 μL of freshly prepared STC (1:2 dilution) to UltrAuFoil 300 mesh R1.2/1.3 holey grids (Quantifoil), glow-discharged for 60 s at 10 mA (Leica EM ACE200) ...
-
bioRxiv - Microbiology 2022Quote: Phage particles were negatively stained for 20 s with 2 % uranyl acetate on carbon-coated copper grids (Quantifoil) and observed at 100 kV on a Hitachi HT 7700 equipped with an AMT XR81B Peltier cooled CCD camera (8M pixel ...
-
bioRxiv - Microbiology 2023Quote: ... Phage particles were negatively stained for 20 seconds with 2% uranyl acetate on carbon-coated copper grids (Quantifoil) and observed at 100 kV on a Hitachi HT 7700 equipped with an AMT XR81B Peltier cooled CCD camera (8M pixel ...
-
bioRxiv - Microbiology 2022Quote: ... the amoebae (5×105 per well) were seeded onto EM gold finder grids (Au NH2 R2/2, Quantifoil) and incubated for 1 h ...
-
bioRxiv - Biochemistry 2023Quote: ... Differentiated U937 cells became adhesive and were seeded onto gold London Finder grids (Au H2 R2/2, Quantifoil) coated with vitronectin (25 µg/mL in 1xPBS ...
-
bioRxiv - Biochemistry 2024Quote: About 3 µl of the purified complex sample was applied to a freshly-glow discharged Au 300 mesh R1.2/1.3 grids coated with 2 nm carbon film (Quantifoil). The grids were blotted with force level of 1 and blot time of 4s ...
-
bioRxiv - Microbiology 2024Quote: Cryo-ET samples were prepared using copper grids with holey carbon support film (300 mesh, R2/2, Quantifoil) as previously described116 ...
-
bioRxiv - Biophysics 2024Quote: ... Regions of the LCP drops were scooped and gently smeared across pre-clipped Cu200 R2:2 grids (Quantifoil) under a humidifier ...
-
bioRxiv - Biophysics 2024Quote: 3.5 µL of sample were applied to 2/1 Quantifoil holey carbon grids (Quantifoil Micro Tools GmbH, Germany) or 1.2/1.3 Ultrafoil holey gold grids (Quantifoil Micro Tools GmbH ...
-
bioRxiv - Biochemistry 2021Quote: 3.5 µl protein solution containing 0.05 µM CUL4-NEDD8/ROC1/DDB1/DCAF1-CtD/Vprmus/SAMHD1 complex and 0.25 µM UBCH5C-ubiquitin conjugate (S4 A, B Fig) were applied to a 300 mesh Quantifoil R2/4 Cu/Rh holey carbon grid (Quantifoil Micro Tools GmbH) coated with an additional thin carbon film as sample support and stained with 2% uranyl acetate for initial characterisation ...
-
bioRxiv - Biochemistry 2022Quote: ... Spike trimer - Fab complexes (4 μl) were applied to the pre-glow-discharged holey carbon grids (Quantifoil grid, Cu 300 mesh, R1.2/1.3). The grids were then blotted for 2 seconds with filter paper in 100% relative humidity and 8 °C and plunged into the liquid ethane to freeze samples using FEI Vitrobot system (FEI).
-
bioRxiv - Molecular Biology 2023Quote: ... a 4 µl sample of purified complex was applied to glow-discharged R2/1 300 mesh holey carbon copper grids (Quantifoil Micro Tools GmbH), using a conc ...
-
bioRxiv - Cell Biology 2023Quote: 4 ul of Nannochloropsis suspensions (4 x 107 cells mL−1) were pipetted onto a 300 mesh gold Quantifoil grid with 2um holes (Quantifoil Micro Tools, GmbH) and manually blotted from the opposite side in a Vitrobot Mark IV (ThermoFisher Scientific ...
-
bioRxiv - Biochemistry 2023Quote: 4 μL of Fcα–J–FcRL4 (0.3 mg/mL) were applied to glow-discharged holy-carbon gold grids (Quantifoil, R1.2/1.3, 300 mesh) or Ni-Ti grids (CryoMatrix ...
-
bioRxiv - Molecular Biology 2022Quote: ... An aliquot of 4 μL protein sample of Spike protein was applied onto a glow-discharged 300 mesh grid (Quantifoil Au R1.2/1.3) and GraFuture™-RGO grid which was supported with a thin layer of RGO (reduced graphene oxide) ...
-
bioRxiv - Cell Biology 2020Quote: ... HeLa cells were grown for 24 h on holey carbon-covered gold EM grids (200 mesh, R2/2, Quantifoil), fed with oleic acid and induced with doxycycline for Fsp27-EGFP expression for an unrelated project ...
-
bioRxiv - Microbiology 2022Quote: ... 3 μl aliquots of the mixture was applied to R2/2 200 mesh copper Quantiofoil grids (Quantifoil Micro Tools) that were freshly glow discharged ...
-
bioRxiv - Biophysics 2020Quote: Three microliters of purified HCoV-NL63 virions (4.5 mg/mL) were first applied to 300-mesh R2/1 + 2 nm C-film grids (Quantifoil) that had been glow-discharged for 15s PELCO easiGlow (TED PELLA ...
-
bioRxiv - Microbiology 2021Quote: ... 3 µl of sample were applied to a freshly glow-discharged Quantifoil Au R2/2 200 mesh grid (Quantifoil), blotted for 5.5-7.5 s (0.5 s drain time ...
-
bioRxiv - Microbiology 2021Quote: ... 3 µl of sample were applied to a freshly glow-discharged Quantifoil Au R2/2 200 mesh grid (Quantifoil), blotted for 3.5-7.5 s (0.5 s drain time ...
-
bioRxiv - Microbiology 2021Quote: ... and 5 µl of the mixture was placed onto freshly glow discharged holey carbon grids (R 2/1, Quantifoil) for 1 min ...
-
bioRxiv - Biophysics 2020Quote: Cryo-EM grids were prepared by applying freshly purified channel protein (~3.5 μl) to glow-discharged copper Quantifoil R2/2 holey carbon grids (Quantifoil), which were then blotted for 2 s with ~100% humidity and flash frozen in liquid ethane using FEI Vitrobot Mark IV (FEI) ...
-
bioRxiv - Cell Biology 2021Quote: ... cells were grown on 200 mesh gold R2/2 London Finder Quantifoil grids (Quantifoil Micro Tools GmbH, Jena, Germany). Prior to seeding cells ...
-
bioRxiv - Biophysics 2023Quote: ... using FluoSpheres (diameter of 1 μm) on gold Quantifoil grids (200 mesh, R 2/1, holey SiO2 film; Quantifoil Micro Tools GmbH ...
-
bioRxiv - Biophysics 2023Quote: Gold 200 mesh carbon or SiO2 R 2/1 grids or R 1.2/20 grids (Quantifoil Micro Tools GmbH) were coated with ∼8 nm of carbon using a Leica ACE600 (Leica Microsystems GmbH) ...
-
bioRxiv - Biophysics 2023Quote: ... 4 μl of 4.3 mg/ml Slo1-γ1 complex were applied to glow-discharged UltrAuFoil R2/2 200 grid (Quantifoil). Any excess liquid was removed by blotting for 3.5 s at a blot force of −3 ...
-
bioRxiv - Biophysics 2024Quote: ... Aliquots of 1.25 – 1.5 ul RyR1-nanodisc were applied onto each side of glow-discharged C-Flat - 2/1 - 3Au holey-carbon (Protochips, NC) or UltraAufoil -1.2/1.3 holey-gold (Quantifoil, Germany) with 300 TEM mesh ...
-
bioRxiv - Biophysics 2024Quote: ... This bleb/beads suspension was then applied onto glow discharged plasma-cleaned carbon-coated copper grids (GR1/2, Quantifoil) and manually blotted for ∼3 seconds with 55 mm Whatman filter paper (ThermoFisher ...
-
bioRxiv - Microbiology 2023Quote: ... This mixture was applied to the front (3.7 µL) and to the back (1.3 µL) of carbon-coated copper grids (R2/2, Cu 200 mesh; Quantifoil) previously glow-discharged (2 mA ...
-
bioRxiv - Microbiology 2024Quote: ... 3.5 µL of sample was applied to a glow discharged UltrAufoil holey gold grids (R2/2, 200 mesh, Quantifoil). Grid were blotted for 5 s at 4°C and 95% relative humidity before freezing in liquid ethane using a Vitrobot Mark IV (FEI) ...
-
bioRxiv - Molecular Biology 2021Quote: ... 4 μl of protein sample (about 1.5 mg/ml) was applied onto a glow-discharged holey carbon grid (Quantifoil Au, R1.2/1.3, 300 mesh). At a temperature of 4°C and under a humidity of 100% ...
-
bioRxiv - Biochemistry 2022Quote: 4 µl aliquots of purified samples at A280 = 1 were applied onto glow-discharged holey carbon-coated grids (Quantifoil 300 mesh, Au R1.2/1.3), then adsorbed for 10 s ...
-
bioRxiv - Biophysics 2020Quote: ... 3.5 µl of purified channel proteins at ∼6 mg/ml were pipetted onto glow-discharged copper Quantifoil R2/2 holey carbon grids (Quantifoil). Grids were blotted for 2 s at ∼100% humidity and flash frozen in liquid ethane ...
-
bioRxiv - Biochemistry 2020Quote: ... 3 μL of the concentrated RdRp-RNA complex were mixed with 0.5 μl of octyl ß-D-glucopyranoside (0.003% final concentration) and applied to freshly glow discharged R 2/1 holey carbon grids (Quantifoil). The grids were blotted for 5 seconds using a Vitrobot MarkIV (Thermo Fischer Scientific ...
-
bioRxiv - Biochemistry 2021Quote: ... 3 µL of the concentrated RdRp-RNA complex were mixed with 0.5 µl of octyl ß-D-glucopyranoside (0.003% final concentration) and applied to freshly glow discharged R 2/1 holey carbon grids (Quantifoil). The grids were blotted for 7 seconds with blot force 5 using a Vitrobot MarkIV (Thermo Fischer Scientific ...
-
bioRxiv - Biophysics 2020Quote: ... and urine were applied in 3 µl-volumes onto glow-discharged Quantifoil Au R2/2 holey carbon 300 mesh grids (Quantifoil). Grids were blotted for 2.0 s and plunged into liquid ethane cooled by liquid nitrogen ...
-
bioRxiv - Biochemistry 2022Quote: ... 3.0 μL of sample was applied to glow-discharged 200-mesh copper 2 nm C R1.2/1.3 cryo-EM grids (Quantifoil Micro Tools), blotted 1 s at 100 % humidity ...
-
bioRxiv - Biochemistry 2022Quote: ... 2.5 μL of sample was applied to glow-discharged 200-mesh copper 2 nm C R1.2/1.3 cryo-EM grids (Quantifoil Micro Tools), blotted 3 s at 75 % humidity ...
-
bioRxiv - Biophysics 2020Quote: ... 3 μL of the concentrated RdRp-RNA complex were mixed with 0.5 μl of octyl ß-D-glucopyranoside (0.003% final concentration) and applied to freshly glow discharged R 2/1 holey carbon grids (Quantifoil). Prior to flash freezing in liquid ethane ...
-
bioRxiv - Cell Biology 2022Quote: Cells were applied onto galectin-8 coated EM grids with carbon support film (R2/2, Au mesh; Quantifoil, Jena, Germany). After 15-20 min incubation ...