Labshake search
Citations for Quantifoil Micro Tools :
301 - 350 of 675 citations for 1 2 4 4 4 Pentachloropentafluorobutane since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biochemistry 2023Quote: ... Holey carbon R2/2 300 mesh grids (Quantifoil Micro Tools GmbH) were glow-discharged for 90 sec at 25 mA using a PELCO easiGlow glow discharge cleaning system ...
-
bioRxiv - Microbiology 2024Quote: Cryo-EM gold grids (Quantifoil R2/2 Au 200 mesh, Quantifoil) were placed in the slots of a custom-made PDMS stencil (Alvéole ...
-
bioRxiv - Microbiology 2024Quote: Cryo-EM gold grids (Quantifoil R2/2 Au 200 mesh, Quantifoil) were placed in the slots of a custom-made PDMS stencil (Alvéole ...
-
bioRxiv - Biochemistry 2024Quote: Quantifiol R 1.2/1.3 Au 400 mesh 2 nm Carbon (Quantifoil) were glow discharged at 0.2 atm for 30 s and were loaded onto a FEI vitrobot (Thermo Fisher) ...
-
bioRxiv - Biochemistry 2024Quote: 4 μl of the inhibition reaction mixture was applied onto plasma cleaned holey carbon grids coated with 2nm thick amorphous carbon (Quantifoil R 2/2, UT, 300 Mesh, Copper). Following 30 sec of incubation inside the chamber of FEI Vitrobot MK IV (FEI ...
-
bioRxiv - Biochemistry 2024Quote: ... Those nucleosomes that passed the quality control were then loaded into a freshly glow discharged holey carbon golden grid (Quantifoil™ R 2/2 on 300 gold mesh) (2.5 µg of nucleosome diluted in 40 mM NaCl reconstitution buffer in 3 μl was loaded in the grid) ...
-
bioRxiv - Cell Biology 2020Quote: Either 200 mesh gold holey carbon grids (R2/2; Quantifoil Micro Tools) or 200 mesh gold grids (Science Services ...
-
bioRxiv - Microbiology 2022Quote: ... cells were seeded on R2/2 gold UltrAufoil grids (200 mesh, Quantifoil Micro Tools GmbH ...
-
bioRxiv - Molecular Biology 2020Quote: ... gold 300 mesh Quantifoil R2/2 holey carbon grids (Quantifoil Micro Tools) were glow discharged using an Edwards Sputter Coater 305B ...
-
bioRxiv - Biophysics 2022Quote: ... Quantifoil grids (200 mesh Au R2/2 carbon or SiO2 film; Quantifoil Micro Tools GmbH ...
-
bioRxiv - Neuroscience 2020Quote: ... electron microscopy (EM) gold finder grids (Quantifoil R2/2 Au NH2 grids) were plasma cleaned with H2 and O2 for 10 s using a plasma cleaning system (Gatan) ...
-
bioRxiv - Biochemistry 2022Quote: Quantifoil R2/2 Cu300 or Quantifoil R1.2/1.3 Cu300 (Quantifoil Micro Tools) grids were glow-discharged using the GloQube plasma cleaner (Quorum ...
-
bioRxiv - Biochemistry 2021Quote: ... grids with an additional thin layer (∼2 nm) of continues carbon (Quantifoil). The GudB6-GltA2B2 complex solution was applied to the grid in a single 2.5 µl drop ...
-
bioRxiv - Molecular Biology 2022Quote: Quantifoil 200 mesh holey carbon R2/2 gold grids (Quantifoil Micro Tools) were glow discharged (PELCO easiGlow ...
-
bioRxiv - Microbiology 2022Quote: R2/2 carbon-coated 200 mesh copper Quantifoil grids (Quantifoil Micro Tools) were first glow-discharged for 60 seconds ...
-
bioRxiv - Microbiology 2022Quote: ... Quantifoil R2/2 200 mesh carbon grids (Quantifoil Micro Tools, Jena, Germany) were plasma cleaned using the Quorum Q150s glow discharger (Quorum technologies ...
-
bioRxiv - Molecular Biology 2024Quote: ... Quantifoil R2/2 gold 200 mesh grid (Quantifoil Micro Tools GmbH, Germany) glow-discharged for 30 sec in a PIB-10 Ion Bombarder (Vacuum Device Inc ...
-
bioRxiv - Biophysics 2024Quote: ... R1.2/1.3 or R2/2 UltrAuFoil® grids (Quantifoil Micro Tools GmbH) were glow-discharged with 40 mA for 5 min inside a Quorum GloQube® Plus unit ...
-
bioRxiv - Biochemistry 2024Quote: Standard holey carbon electron microscopy grids (Quantifoil, Cu 200 mesh, R2/2) were glow discharged for 30 s at 15 mA on the negative setting ...
-
bioRxiv - Microbiology 2021Quote: ... loaded onto a R2/2 200 mesh Cu grid (Quantifoil Micro Tools, GmbH), and plunge frozen in liquid ethane using the automated Leica EM GP plunge freezer (Leica Microsystems GmbH) ...
-
bioRxiv - Cell Biology 2020Quote: 200 mesh holey silicon dioxide (SiO2) titanium grids (R2/2; Quantifoil Micro Tools) were glow discharged in an ELMO glow discharge unit (Cordouan Technologies ...
-
bioRxiv - Microbiology 2024Quote: Glow-discharged gold EM grids (200 mesh, Au, holey SiO, R1/2, Quantifoil) were placed into polydimethylsiloxane Sylgard 184 (Farnell GmbH ...
-
bioRxiv - Microbiology 2024Quote: Ultrafoil Au R2/2 200 mesh grids (200 mesh, Quantifoil Micro Tools GmbH) were glow discharged ...
-
bioRxiv - Biochemistry 2020Quote: Quantifoil R2/2 300 mesh holey carbon copper grids (Quantifoil Micro Tools, Großlöbichau, Germany) were glow-discharged (ELMO Glow Discharge System ...
-
bioRxiv - Biophysics 2020Quote: ... and applied 3 μL to glow discharged EM grids (Quantifoil R2/2 400 mesh). The GFP portion of this substrate consisted of residues 1-229 ...
-
bioRxiv - Molecular Biology 2022Quote: ... 2–3 μL of sample solution was applied to a holey carbon grid (Quantifoil R2/1 ...
-
bioRxiv - Biochemistry 2024Quote: ... Three microliters of sample were applied to glow-discharged R2/2 carbon grids (Quantifoil), which were blored for 5 s and at a blot force of 25 and plunge-frozen in liquid ethane with a Vitrobot Mark IV (ThermoFisher ...
-
bioRxiv - Molecular Biology 2023Quote: ... Quantifoil R1.2/1.3 400-square mesh Cu grids with 2 nm continuous carbon (Quantifoil) were glow-discharged for 8 s at 10 mA using a PELCO easiGlow glow discharging system (Ted Pella ...
-
bioRxiv - Cell Biology 2022Quote: MEF were seeded on R2/2 holey carbon on gold grids (Quantifoil or Protochips) coated with fibronectin in a glass bottom dish (Mattek or Ibidi ...
-
bioRxiv - Cell Biology 2022Quote: ... The cells were seeded on EM grids (Quantifoil SiO2 R2/2, 200 mesh, gold) in a 3D printed specimen holder [43] and grown overnight.
-
bioRxiv - Biochemistry 2023Quote: ... Quantifoil R2/2 Cu 400 mesh holey carbon grids (Quantifoil Micro Tools, Jena, Germany) coated with a 0.4 mg/ml graphene oxide suspension (Sigma-Aldrich ...
-
bioRxiv - Biophysics 2024Quote: ... gold grids coated with holey carbon film (300 mesh, R2/2, Quantifoil, Jena, Germany) were glow-discharged and UV-treated for 1 h ...
-
bioRxiv - Cell Biology 2024Quote: ... cells were seeded onto holey carbon gold EM grids (200 mesh, R2/2, Quantifoil) coated with 10 mg/ml fibronectin ...
-
bioRxiv - Molecular Biology 2021Quote: ... and applied onto freshly glow-discharged 200 square mesh Ultrafoil R2/2 gold grids (Quantifoil). The samples were plunge-frozen with a FEI Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Microbiology 2021Quote: ... Freshly glow-discharged finder gold quantifoil grids (200 mesh R2/2 – Quantifoil MicroTools GmbH, Germany) were sterilized in 70% EtOH and placed in a glass-bottomed MatTek dish (MatTek Corporation ...
-
bioRxiv - Microbiology 2021Quote: ... were applied to freshly washed and glow-discharged R2/2 holey carbon copper grids (Quantifoil). The grids were manually back blotted for 2 to 3s with filter paper ...
-
bioRxiv - Biochemistry 2021Quote: ... Cryo-EM grids were prepared using glow discharged R2/2 Cu 200 mesh grids (Quantifoil) pre-floated onto custom-made 2.9 nm continuous carbon film ...
-
bioRxiv - Microbiology 2023Quote: ... sample aliquots of 3 µL were applied onto UltrAuFoil R2/2 grids (300 mesh, Quantifoil). Grids were blotted for 1 s at 10°C with 100% relative humidity and immediately plunge frozen into liquid ethane using a Vitrobot Mark IV system (TFS) ...
-
bioRxiv - Molecular Biology 2023Quote: ... 3.5 μL) were applied to precoated (2 nm) R1.2/1.3 carbon-supported copper grids (Quantifoil), blotted for 4-5 s at 4°C ...
-
bioRxiv - Biophysics 2024Quote: ... and 3 µL were applied to glow-discharged R2/2 holey carbon copper grids (Quantifoil). These grids were manually back blotted for 2 to 3s with filter paper ...
-
bioRxiv - Microbiology 2021Quote: ... 3μl was added to a glow-discharged R2/2 200 mesh holey carbon EM grid (Quantifoil) for 30 seconds and the sample was blotted for 1 second ...
-
bioRxiv - Biochemistry 2022Quote: ... 3 µL of purified PPSA was applied to glow-discharged holy grids (Quantifoil, Cu200, R2/2) for 30s ...
-
bioRxiv - Cell Biology 2022Quote: ... A volume of 2.5 μL was applied on glow-discharged UltrAuFoil Au200 R2/2 grids (Quantifoil), and excess liquid was removed by blotting for 3 s (blot force 5 ...
-
bioRxiv - Biochemistry 2023Quote: The final high resolution data set was collected across 2 grids (Quantifoil 1.2/1.3 200 mesh) prepared with 1.8 mg mL-1 trimeric complex and 0.5 and 0.1 X CMC CHAPS ...
-
bioRxiv - Molecular Biology 2023Quote: ... Quantifoil R1.2/1.3 400-square mesh copper grids with a 2 nm continuous carbon layer (Quantifoil) were plasma-treated in a Pelco easiGlow glow discharging system (Ted Pella ...
-
bioRxiv - Biophysics 2024Quote: ... Vero cells were seeded either on gold finder grids (200 mesh, R2/2, Quantifoil, Jena, Germany) or gold grids coated with lacey carbon film (XXBR Technology ...
-
bioRxiv - Evolutionary Biology 2024Quote: ... Three-hundred mesh R1.2/1.3 UltrAuFoil grids with a layer of 2 nm amorphous carbon (Quantifoil) were glow discharged in a Pelco easiGlow for 12 seconds under a 0.37 mBar vacuum with 25 mA current ...
-
bioRxiv - Biochemistry 2021Quote: Three microliters of the h20S-PA26E102A-Opt5 solution were applied to R2/2 400-mesh grids (Quantifoil) that had been plasma treated for 25 s using a glow discharger (Electron Microscopy Sciences ...
-
bioRxiv - Molecular Biology 2022Quote: ... 3.5 μL was applied to freshly glow-discharged Quantifoil R2/2 300-square-mesh gold grids (Quantifoil) in a Vitrobot IV (ThermoFisher ...
-
bioRxiv - Biophysics 2020Quote: ... 2 μl apoferritin was applied to glow-discharged gold holey carbon 1.2/1.3 300-mesh grids (Quantifoil). Grids were blotted for 4 seconds at -2 force and vitrified in liquid ethane using a MarkIV Vitrobot (ThermoFisher) ...