Labshake search
Citations for Quantifoil Micro Tools :
251 - 300 of 301 citations for Potassium 3 4 difluorophenyl trifluoroborate since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2022Quote: ... Samples were centrifuged at 3,000 g for 3 min and applied to glow-discharged holey carbon gold grids (Quantifoil Au R1.2/1.3, 300 mesh), which were glow-discharged with an Edwards (S150B ...
-
bioRxiv - Pharmacology and Toxicology 2024Quote: Grids were prepared by applying 3 μL of purified CB1-Gi complex at 12 mg/ml to glow-discharged holey carbon gold grids (Quantifoil R1.2/1.3, 200 mesh). The grids were blotted using a Vitrobot Mark IV (FEI ...
-
bioRxiv - Molecular Biology 2023Quote: Freshly purified ZorAB sample was concentrated to 2-3 mg/mL and 2.7 μL protein was applied onto the glow-discharged (30 s, 5 mA) grids (Quantifoil R0.6/1 300 mesh Au) and plunge-frozen into liquid ethane using a Vitrobot Mark IV (FEI ...
-
bioRxiv - Molecular Biology 2021Quote: ... bremelanotide– or THIQ–bound MC4R–Gs complexes at ∼ 4 mg/mL were applied onto glow-discharged holey carbon grids (Quantifoil R1.2/1.3). Excess samples were blotted away and the grids were vitrified by plunging into liquid ethane using a Vitrobot Mark IV (ThermoFischer Scientific).
-
bioRxiv - Genomics 2020Quote: ... Vitrified specimens were prepared by adding 4 μl disome samples at the concentration of ~ 150 nM to a glow-discharged holey carbon grid (Quantifoil R1.2/1.3), which was covered with a freshly made thin carbon film ...
-
bioRxiv - Cell Biology 2020Quote: ... The MEFs were applied onto glow-discharged EM grids with a silicon-oxide support film (R1/4, Au mesh; Quantifoil, Jena, Germany). After incubation ...
-
Genome modularization reveals overlapped gene topology is necessary for efficient viral reproductionbioRxiv - Synthetic Biology 2020Quote: A 4 μL solution of co-isolated small particles were applied to glow-discharged copper grids (Quantifoil R2/2, Quantifoil Micro Tools), blotting for 3-seconds at 4 °C with 90% humidity and plunging into liquid ethane using a Lecia EM GP device (Leica Microsystems ...
-
Genome modularization reveals overlapped gene topology is necessary for efficient viral reproductionbioRxiv - Synthetic Biology 2020Quote: A 4 μL solution of co-isolated small particles were applied to glow-discharged copper grids (Quantifoil R2/2, Quantifoil Micro Tools), blotting for 3-seconds at 4 °C with 90% humidity and plunging into liquid ethane using a Lecia EM GP device (Leica Microsystems ...
-
bioRxiv - Molecular Biology 2020Quote: The grids were prepared by applying 4 µL of each complex at ∼70 nM to 400 mesh holey carbon Quantifoil 2/2 grids (Quantifoil Micro Tools). The grids were blotted for 1.5 sec at 4°C ...
-
bioRxiv - Cell Biology 2023Quote: ... Four µL of the cells were subsequently deposited onto Quantifoil R2/4 200 mesh copper grids (Quantifoil Micro Tools GmbH, Jena, Germany), which were then manually blotted from the back with Whatman® Grade 1 filter paper for approximately 3 – 5 seconds ...
-
bioRxiv - Cell Biology 2024Quote: ... the sample was gently resuspended and 4 µl was transferred to a glow-discharged holey carbon R2/1 copper grid (Quantifoil Micro Tools) suspended in the chamber of a Vitrobot (Thermo Fisher Scientific) ...
-
bioRxiv - Biophysics 2023Quote: ... 4 μl suspended cells were loaded onto the front side of glow-discharged holy-carbon copper grids (Quantifoil R1.2/1.3, 200 mesh), and 2 μl medium was subsequently added to the back side of the grids ...
-
bioRxiv - Cell Biology 2022Quote: The cryo-EM grid was prepared by applying 3 μl of the protein samples (4 – 6 mg/ml) to glow-discharged Quantifoil R1.2/1.3 300-mesh gold holey carbon grids (Quantifoil, Micro Tools GmbH, Germany). Grids were blotted for 4.0 seconds under 100% humidity at 4°C before being plunged into the liquid ethane using a Mark IV Vitrobot (FEI) ...
-
Mycobacteria form viable cell wall-deficient cells that are undetectable by conventional diagnosticsbioRxiv - Microbiology 2022Quote: ... of which 3-4 µL was applied on glow-discharged 200 mesh copper grids with an extra thick R2/2 carbon film (Quantifoil Micro Tools). Vitrification was performed using an automated Leica EM GP plunge-freezer ...
-
bioRxiv - Biochemistry 2024Quote: Grids for cryo-EM were prepared by applying 4 µL of sample on a glow-discharged Quantifoil 300 mesh Cu 2/1 grid (Quantifoil Micro Tools), blotting for 7.5 seconds ...
-
bioRxiv - Biochemistry 2022Quote: ... Samples were prepared by depositing 3 μl of the crystalline slurry onto a glow-discharged EM grid (Quantifoil, Cu 200 mesh, R2/2 holey carbon). Excess liquid was blotted away and the sample was vitrified using a Leica GP2 vitrification robot ...
-
bioRxiv - Biochemistry 2022Quote: ... Several serial dilutions were prepared and 3 µl of each sample was loaded on Quantifoil R2/2Cu/Rh 300 holey-carbon-supported grids (Quantifoil Micro Tools GmbH, Jena, Germany). Initial cryo-EM sample preparations showed clear protein aggregation ...
-
bioRxiv - Biophysics 2022Quote: Cryo-EM grids were prepared by applying 3 μL of sample (at the native 1 nM concentration) on glow discharged holey gold grids (Quantifoil Cu 1.2/1.3 400 mesh). Excess sample was removed by blotting with filter paper for 4 sec prior to plunge-freezing in liquid ethane using a FEI Vitrobot Mark IV at 100% humidity and 4 °C ...
-
bioRxiv - Molecular Biology 2020Quote: Cryo-EM grids were prepared by applying 3 µL sample (at a protein concentration of 1 mg/ml) on glow-discharged holey gold grids (Quantifoil Au 1.2/1.3 300 mesh). Excess sample was removed by blotting with filter paper for 2-3 s before plunge-freezing in liquid ethane (cooled to −181 °C ...
-
bioRxiv - Microbiology 2020Quote: ... 3.5 μl of that mixture was transferred to a 3 mm freshly glow-discharged Quantifoil R2/2 Cu 300 mesh holey carbon grid (Quantifoil Micro Tools GmbH, Jena, Germany). Excess liquid was blotted away using a Leica EM GP plunge-freezer at room temperature and 80% humidity (blot time 2-3 sec ...
-
bioRxiv - Immunology 2020Quote: An aliquot of 3 μl purified protein of rNLRP1-rDPP9 or rNLRP1FIIND S969A-rDPP9 complex was applied to holey carbon grids (Quantifoil Au 1.2/1.3, 300 mesh), which were glow-discharged for 30 s at middle level in Harrick Plasma after 2 min evacuation ...
-
bioRxiv - Molecular Biology 2023Quote: 3 µL of the human CDCA7264-371 in complex with the nucleosome harboring a single hemimethylated CpG in the 3’-linker DNA was applied onto the glow-discharged holey carbon grids (Quantifoil Cu R1.2/1.3, 300 mesh). The grids were plunge-frozen in liquid ethane using a Vitrobot Mark IV (Thermo Fisher Scientific) ...
-
bioRxiv - Molecular Biology 2022Quote: ... The pellet was then resuspended in warm EM buffer and 3 μL of this sample was applied to a carbon on gold grid (Quantifoil R2/2 Au 200 mesh), recently glow-discharged for 1 min at 30 mA ...
-
bioRxiv - Biophysics 2023Quote: 2.5μL aliquots of Fks1 at a concentration of about 3 mg/mL were placed on glow-discharged holey carbon grids (Quantifoil Au R1.2/1.3, 300 mesh) and were flash-frozen in liquid ethane using a FEI Vitrobot Mark IV ...
-
bioRxiv - Cell Biology 2024Quote: Vitrified grids were prepared by applying 3 µl of 1 uM complex sample to a freshly glow- discharged holey carbon grids (Quantifoil R1.2/1.3 Au 200 mesh). The sample was blotted for 3-5 s at 4 ℃ with 100% humidity and plunged-frozen in liquid nitrogen cooled ethane (FEI TM ...
-
bioRxiv - Biochemistry 2021Quote: 3.5 µl protein solution containing 0.05 µM CUL4-NEDD8/ROC1/DDB1/DCAF1-CtD/Vprmus/SAMHD1 complex and 0.25 µM UBCH5C-ubiquitin conjugate (S4 A, B Fig) were applied to a 300 mesh Quantifoil R2/4 Cu/Rh holey carbon grid (Quantifoil Micro Tools GmbH) coated with an additional thin carbon film as sample support and stained with 2% uranyl acetate for initial characterisation ...
-
bioRxiv - Biochemistry 2022Quote: ... Spike trimer - Fab complexes (4 μl) were applied to the pre-glow-discharged holey carbon grids (Quantifoil grid, Cu 300 mesh, R1.2/1.3). The grids were then blotted for 2 seconds with filter paper in 100% relative humidity and 8 °C and plunged into the liquid ethane to freeze samples using FEI Vitrobot system (FEI).
-
bioRxiv - Molecular Biology 2023Quote: ... a 4 µl sample of purified complex was applied to glow-discharged R2/1 300 mesh holey carbon copper grids (Quantifoil Micro Tools GmbH), using a conc ...
-
bioRxiv - Cell Biology 2023Quote: 4 ul of Nannochloropsis suspensions (4 x 107 cells mL−1) were pipetted onto a 300 mesh gold Quantifoil grid with 2um holes (Quantifoil Micro Tools, GmbH) and manually blotted from the opposite side in a Vitrobot Mark IV (ThermoFisher Scientific ...
-
bioRxiv - Biochemistry 2023Quote: 4 μL of Fcα–J–FcRL4 (0.3 mg/mL) were applied to glow-discharged holy-carbon gold grids (Quantifoil, R1.2/1.3, 300 mesh) or Ni-Ti grids (CryoMatrix ...
-
bioRxiv - Molecular Biology 2022Quote: ... An aliquot of 4 μL protein sample of Spike protein was applied onto a glow-discharged 300 mesh grid (Quantifoil Au R1.2/1.3) and GraFuture™-RGO grid which was supported with a thin layer of RGO (reduced graphene oxide) ...
-
bioRxiv - Immunology 2023Quote: ... respectively) and 3 μl were kept 5 min at RT until their application onto glow-discharged holey carbon grids (Quantifoil, Au 300 mesh, R 0.6/1). The grids were blotted and then plunged into liquid ethane using a FEI Vitrobot Mark IV at 20°C and 95% relative humidity ...
-
bioRxiv - Biophysics 2024Quote: 3 μL of concentrated protein sample was applied to a glow-discharged (30 s at 15 mA) grid (Quantifoil Au or Cu R1.2/1.3 300 mesh) and after a wait time of 5 s ...
-
bioRxiv - Biochemistry 2024Quote: 3µl of the AtGDH-AKG bound binary complex (3 mg/ml) was applied to freshly glow-discharged holey carbon grids (Quantifoil Au R 0.6/1.0 300 mesh). For the apo form AnGDH dataset ...
-
bioRxiv - Biophysics 2020Quote: ... 2.5 μl samples of GDN-purified proteins at a concentration of 1.5-3 mg ml−1 were applied to glow-discharged holey carbon grids (Quantifoil R1.2/1.3 or R0.6/1 Au 200 mesh). Excess liquid was removed in a controlled environment (4°C and 100% relative humidity ...
-
bioRxiv - Biochemistry 2023Quote: ... A 3 µL drop was applied to a glow-discharged (PELCO easiGlow, 15 mA, 2 min) holey carbon grid (Quantifoil R1.2/1.3 on gold 200 mesh support), blotted for 3-4 seconds with Whatman Grade 595 filter paper (GE Healthcare) ...
-
bioRxiv - Molecular Biology 2021Quote: ... 4 μl of protein sample (about 0.73 mg/ml) was applied onto a glow-discharged holey carbon grid (Quantifoil Au, R2/2, 300 mesh). After blotting for 3 s ...
-
bioRxiv - Molecular Biology 2021Quote: ... 4 μl of protein sample (about 1.5 mg/ml) was applied onto a glow-discharged holey carbon grid (Quantifoil Au, R1.2/1.3, 300 mesh). At a temperature of 4°C and under a humidity of 100% ...
-
bioRxiv - Biochemistry 2022Quote: 4 µl aliquots of purified samples at A280 = 1 were applied onto glow-discharged holey carbon-coated grids (Quantifoil 300 mesh, Au R1.2/1.3), then adsorbed for 10 s ...
-
bioRxiv - Molecular Biology 2021Quote: ... 3.5 μL was applied to a glow-discharged Quantifoil copper grid with 2 nm continuous carbon support over holes (Quantifoil R 2/4 400 mesh), blotted ...
-
bioRxiv - Microbiology 2020Quote: ... A small volume (4 µL) of cells was then transferred onto freshly glow‐discharged copper R2/2 200 Quantifoil holey carbon grids (Quantifoil Micro Tools GmbH, Jena, Germany). Grids were then blotted and plunge‐frozen in a liquid ethane/propane mixture 31 using an FEI Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Biophysics 2020Quote: ... An aliquot of 4 μl pY39 α-syn fibril solution was applied to a glow-discharged carbon electron microscope grid (Quantifoil R1.2/1.3, 300 mesh). After 10 s of incubation ...
-
bioRxiv - Molecular Biology 2021Quote: The purified GIP1-42–GIPR–Gs–Nb35 complex at a concentration of 6-7 mg/mL was mixed with 100 μM GIP1-42 at 4 C and applied to glow-discharged holey carbon grids (Quantifoil R1.2/1.3, Au 300 mesh) that were subsequently vitrified by plunging into liquid ethane using a Vitrobot Mark IV (ThermoFisher Scientific) ...
-
bioRxiv - Molecular Biology 2021Quote: The purified tirzepatide–GIPR–Gs–Nb35 complex at a concentration of 18-20 mg/mL was mixed with 100 μM tirzepatide at 4°C and applied to glow-discharged holey carbon grids (Quantifoil R1.2/1.3, Au 300 mesh) that were subsequently vitrified by plunging into liquid ethane using a Vitrobot Mark IV (ThermoFisher Scientific) ...
-
bioRxiv - Molecular Biology 2021Quote: The purified non-acylated tirzepatide–GIPR–mini-Gs–Nb35 complex at a concentration of 14-16 mg/mL was mixed with 100 μM non-acylated tirzepatide at 4°C and applied to glow-discharged holey carbon grids (Quantifoil R1.2/1.3, Au 300 mesh) that were subsequently vitrified by plunging into liquid ethane using a Vitrobot Mark IV (ThermoFisher Scientific) ...
-
bioRxiv - Molecular Biology 2021Quote: The purified peptide 20–GIPR–Gs–Nb35 complex at a concentration of 5-6 mg/mL was mixed with 100 μM peptide 20 at 4°C and applied to glow-discharged holey carbon grids (Quantifoil R1.2/1.3, Au 300 mesh) that were subsequently vitrified by plunging into liquid ethane using a Vitrobot Mark IV (ThermoFisher Scientific) ...
-
bioRxiv - Molecular Biology 2021Quote: The purified peptide 20–GCGR–Gs–Nb35 complex at a concentration of 12-14 mg/mL was mixed with 100 μM peptide 20 at 4°C and applied to glow-discharged holey carbon grids (Quantifoil R1.2/1.3, Au 300 mesh) that were subsequently vitrified by plunging into liquid ethane using a Vitrobot Mark IV (ThermoFisher Scientific) ...
-
bioRxiv - Biochemistry 2023Quote: ... Four microliters of purified Cx36 proteins (4-6 mg/ml) were applied onto a negatively glow-discharged holey carbon grid (Quantifoil R1.2/1.3 Cu 300 mesh). For samples involving Cx36-WT ...
-
bioRxiv - Biophysics 2020Quote: ... The WT and Y222F MTs were applied to lacey carbon grids (Agar Scientific AGS166-4 400 mesh copper grids) and holey carbon grids (Quantifoil R1.2/1.3 300 mesh copper grids) immediately after application of glow discharge to the grids ...
-
bioRxiv - Biophysics 2023Quote: ... Micropatterns covered an area of 8 × 8 squares around the center of the cryo-TEM grids (Quantifoil R1/4 or R1/20, Au 200 mesh, SiO2 film) as previously described31 ...