Labshake search
Citations for Quantifoil Micro Tools :
251 - 300 of 346 citations for 3 Chloro 5 fluoro 4' morpholinomethyl benzophenone since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Plant Biology 2023Quote: Three µl of purified PSI at a concentration of 3 mg/ml was applied to the glow-discharged holey carbon grids (Cu QUANTIFOIL® R1.2/1.3), then vitrified using a Leica GP2 plunge freezer (2.5 s blot ...
-
bioRxiv - Immunology 2024Quote: ... a 3-μl aliquot was applied onto a glow-discharged QUANTIFOIL® R 1.2/1.3 on Cu 300 mesh grid + 2 nm C Holey Carbon Films with ∼ 2 nm continuous carbon on top (QUANTIFOIL, #C2-C14nCu30-50). The grids were blotted for 2.0 s in 100% humidity at 6°C and plunged into liquid ethane using a VitrobotMkIV (Thermo Fisher Scientific) ...
-
bioRxiv - Biophysics 2024Quote: ... Cryo-EM grids were obtained by flash-freezing 3 µL of purified IPNV particles on glow-discharged holey carbon grids (Quantifoil R2/2, Cu 300 mesh; Quantifoil Micro Tools GmbH). The grids were plunge-frozen in liquid ethane after blotting for 3 s under 4°C ...
-
bioRxiv - Microbiology 2021Quote: ... Aliquots (4 μL) of the protein complex were placed on glow-discharged holey carbon grids (Quantifoil Au R1.2/1.3, 300 mesh). The grids were blotted and flash-frozen in liquid ethane cooled by liquid nitrogen with a Vitrobot apparatus (Mark IV ...
-
bioRxiv - Microbiology 2020Quote: Three μl of purified HKU1 HE (4 mg/ml) was dispensed on Quantifoil R1.2/1.3 200-mesh grids (Quantifoil Micro Tools GmbH) that had been freshly glow discharged for 30 seconds at 20 mA using GloQube Glow Discharge system (Quorum Technologies) ...
-
bioRxiv - Molecular Biology 2021Quote: ... cells in suspension (4 μl of ~1,000 cells per μl) were blotted onto R2/1 carbon-coated 200-mesh copper grids (Quantifoil Micro Tools) and plunge frozen in a liquid ethane/propane mixture ...
-
bioRxiv - Molecular Biology 2022Quote: ... 4 μL of protein samples were immediately applied to discharged 300-mesh Au R1.2/1.3 grids (Quantifoil, Micro Tools GmbH, Germany). Grids were blotted for 4 s and plunged into liquid ethane using an FEI Mark IV Vitrobot operated at 8°C and 100% humidity ...
-
bioRxiv - Cell Biology 2023Quote: ... 4 μl of the sample was applied to glow discharged holey carbon-coated 200 mesh copper EM grids (Quantifoil Micro Tools), vitrified as above at 4°C and 100 % humidity.
-
bioRxiv - Immunology 2024Quote: Neutrophils were stimulated with 100 nM LTB4 in mHBSS for 15 mins at 37 °C in 35 mm glass bottom dishes containing glow-discharged Au SiO2 R1/4 200 mesh grids (Quantifoil GmbH) precoated with 25 μg/ml fibrinogen in DPBS ...
-
bioRxiv - Immunology 2024Quote: ... a 4 μL aliquot of protein complex was applied to glow-discharged holy-carbon gold grids (Quantifoil, R1.2/1.3, 300-mesh) or graphene oxide (GO)-coated holey-carbon gold grids (EMR ...
-
bioRxiv - Microbiology 2021Quote: ... and 5 µl of the mixture was placed onto freshly glow discharged holey carbon grids (R 2/1, Quantifoil) for 1 min ...
-
bioRxiv - Physiology 2021Quote: ... Aliquots of 1.25 – 1.5 μl RyR1-Nanodisc were applied onto each side of glow-discharged UltraAufoil −1.2/1.3 holey-gold (Quantifoil, Germany) with 300 TEM mesh ...
-
bioRxiv - Biophysics 2021Quote: ... A suspension containing a mixture of 10 nm protein A coated colloidal gold (Aurion) and Ebola VLPs was applied with a volume of 3 µl on a glow discharged EM grid (Quantifoil, 200 Mesh, R2/1). The grid was blotted using No.1 Whatman paper for 3 sec from the back-side in a chamber with controlled humidity set to 70% and the temperature set to 24°C.
-
bioRxiv - Biophysics 2022Quote: ... an aliquot of 3 μL of sample was applied onto a glow-discharged holey carbon-coated copper grid (300 mesh, QUANTIFOIL® R 2/1) or holey gold grid (300 mesh ...
-
bioRxiv - Biochemistry 2020Quote: An aliquot of 3 μL of SAM complex sample was applied to freshly glow-discharged holey carbon grid (Quantifoil R1.2/1.3, copper, 300 mesh). The grids were blotted for 6 s and plunge-frozen in liquid nitrogen-cooled liquid ethane using an FEI Vitrobot Mark IV plunger ...
-
bioRxiv - Neuroscience 2022Quote: Extracted filaments were centrifuged at 3,000 g for 3 min and applied to glow-discharged holey carbon gold grids (Quantifoil Au R1.2/1.3, 300 mesh), which were glow-discharged with an Edwards (S150B ...
-
bioRxiv - Neuroscience 2022Quote: ... Samples were centrifuged at 3,000 g for 3 min and applied to glow-discharged holey carbon gold grids (Quantifoil Au R1.2/1.3, 300 mesh), which were glow-discharged with an Edwards (S150B ...
-
bioRxiv - Pharmacology and Toxicology 2024Quote: Grids were prepared by applying 3 μL of purified CB1-Gi complex at 12 mg/ml to glow-discharged holey carbon gold grids (Quantifoil R1.2/1.3, 200 mesh). The grids were blotted using a Vitrobot Mark IV (FEI ...
-
bioRxiv - Neuroscience 2022Quote: Extracted filaments were centrifuged at 3,000g for 3 min and applied to glow-discharged holey carbon gold grids (Quantifoil Au R1.2/1.3, 300 mesh), which were glow-discharged with an Edwards (S150B ...
-
bioRxiv - Biochemistry 2023Quote: ... The detergent was added shortly before applying 3 μL of UBR5Dimer∼UbD∼UBE2D2 to freshly glow-discharged holey carbon grids (Quantifoil, R1.2/1.3, 200 mesh). The sample was consequently plunge-frozen into liquid ethane at 95 % humidity and 4°C (blot force 3 ...
-
bioRxiv - Molecular Biology 2021Quote: ... bremelanotide– or THIQ–bound MC4R–Gs complexes at ∼ 4 mg/mL were applied onto glow-discharged holey carbon grids (Quantifoil R1.2/1.3). Excess samples were blotted away and the grids were vitrified by plunging into liquid ethane using a Vitrobot Mark IV (ThermoFischer Scientific).
-
bioRxiv - Genomics 2020Quote: ... Vitrified specimens were prepared by adding 4 μl disome samples at the concentration of ~ 150 nM to a glow-discharged holey carbon grid (Quantifoil R1.2/1.3), which was covered with a freshly made thin carbon film ...
-
bioRxiv - Cell Biology 2020Quote: ... The MEFs were applied onto glow-discharged EM grids with a silicon-oxide support film (R1/4, Au mesh; Quantifoil, Jena, Germany). After incubation ...
-
Genome modularization reveals overlapped gene topology is necessary for efficient viral reproductionbioRxiv - Synthetic Biology 2020Quote: A 4 μL solution of co-isolated small particles were applied to glow-discharged copper grids (Quantifoil R2/2, Quantifoil Micro Tools), blotting for 3-seconds at 4 °C with 90% humidity and plunging into liquid ethane using a Lecia EM GP device (Leica Microsystems ...
-
Genome modularization reveals overlapped gene topology is necessary for efficient viral reproductionbioRxiv - Synthetic Biology 2020Quote: A 4 μL solution of co-isolated small particles were applied to glow-discharged copper grids (Quantifoil R2/2, Quantifoil Micro Tools), blotting for 3-seconds at 4 °C with 90% humidity and plunging into liquid ethane using a Lecia EM GP device (Leica Microsystems ...
-
bioRxiv - Molecular Biology 2020Quote: The grids were prepared by applying 4 µL of each complex at ∼70 nM to 400 mesh holey carbon Quantifoil 2/2 grids (Quantifoil Micro Tools). The grids were blotted for 1.5 sec at 4°C ...
-
bioRxiv - Cell Biology 2022Quote: The cryo-EM grid was prepared by applying 3 μl of the protein samples (4 – 6 mg/ml) to glow-discharged Quantifoil R1.2/1.3 300-mesh gold holey carbon grids (Quantifoil, Micro Tools GmbH, Germany). Grids were blotted for 4.0 seconds under 100% humidity at 4°C before being plunged into the liquid ethane using a Mark IV Vitrobot (FEI) ...
-
Mycobacteria form viable cell wall-deficient cells that are undetectable by conventional diagnosticsbioRxiv - Microbiology 2022Quote: ... of which 3-4 µL was applied on glow-discharged 200 mesh copper grids with an extra thick R2/2 carbon film (Quantifoil Micro Tools). Vitrification was performed using an automated Leica EM GP plunge-freezer ...
-
bioRxiv - Cell Biology 2024Quote: ... the sample was gently resuspended and 4 µl was transferred to a glow-discharged holey carbon R2/1 copper grid (Quantifoil Micro Tools) suspended in the chamber of a Vitrobot (Thermo Fisher Scientific) ...
-
bioRxiv - Cell Biology 2023Quote: ... Four µL of the cells were subsequently deposited onto Quantifoil R2/4 200 mesh copper grids (Quantifoil Micro Tools GmbH, Jena, Germany), which were then manually blotted from the back with Whatman® Grade 1 filter paper for approximately 3 – 5 seconds ...
-
bioRxiv - Biophysics 2023Quote: ... 4 μl suspended cells were loaded onto the front side of glow-discharged holy-carbon copper grids (Quantifoil R1.2/1.3, 200 mesh), and 2 μl medium was subsequently added to the back side of the grids ...
-
bioRxiv - Biochemistry 2024Quote: Grids for cryo-EM were prepared by applying 4 µL of sample on a glow-discharged Quantifoil 300 mesh Cu 2/1 grid (Quantifoil Micro Tools), blotting for 7.5 seconds ...
-
bioRxiv - Biochemistry 2022Quote: ... Samples were prepared by depositing 3 μl of the crystalline slurry onto a glow-discharged EM grid (Quantifoil, Cu 200 mesh, R2/2 holey carbon). Excess liquid was blotted away and the sample was vitrified using a Leica GP2 vitrification robot ...
-
bioRxiv - Biochemistry 2022Quote: ... Several serial dilutions were prepared and 3 µl of each sample was loaded on Quantifoil R2/2Cu/Rh 300 holey-carbon-supported grids (Quantifoil Micro Tools GmbH, Jena, Germany). Initial cryo-EM sample preparations showed clear protein aggregation ...
-
bioRxiv - Biophysics 2022Quote: Cryo-EM grids were prepared by applying 3 μL of sample (at the native 1 nM concentration) on glow discharged holey gold grids (Quantifoil Cu 1.2/1.3 400 mesh). Excess sample was removed by blotting with filter paper for 4 sec prior to plunge-freezing in liquid ethane using a FEI Vitrobot Mark IV at 100% humidity and 4 °C ...
-
bioRxiv - Molecular Biology 2020Quote: Cryo-EM grids were prepared by applying 3 µL sample (at a protein concentration of 1 mg/ml) on glow-discharged holey gold grids (Quantifoil Au 1.2/1.3 300 mesh). Excess sample was removed by blotting with filter paper for 2-3 s before plunge-freezing in liquid ethane (cooled to −181 °C ...
-
bioRxiv - Microbiology 2020Quote: ... 3.5 μl of that mixture was transferred to a 3 mm freshly glow-discharged Quantifoil R2/2 Cu 300 mesh holey carbon grid (Quantifoil Micro Tools GmbH, Jena, Germany). Excess liquid was blotted away using a Leica EM GP plunge-freezer at room temperature and 80% humidity (blot time 2-3 sec ...
-
bioRxiv - Immunology 2020Quote: An aliquot of 3 μl purified protein of rNLRP1-rDPP9 or rNLRP1FIIND S969A-rDPP9 complex was applied to holey carbon grids (Quantifoil Au 1.2/1.3, 300 mesh), which were glow-discharged for 30 s at middle level in Harrick Plasma after 2 min evacuation ...
-
bioRxiv - Molecular Biology 2022Quote: ... The pellet was then resuspended in warm EM buffer and 3 μL of this sample was applied to a carbon on gold grid (Quantifoil R2/2 Au 200 mesh), recently glow-discharged for 1 min at 30 mA ...
-
bioRxiv - Biophysics 2023Quote: 2.5μL aliquots of Fks1 at a concentration of about 3 mg/mL were placed on glow-discharged holey carbon grids (Quantifoil Au R1.2/1.3, 300 mesh) and were flash-frozen in liquid ethane using a FEI Vitrobot Mark IV ...
-
bioRxiv - Molecular Biology 2023Quote: 3 µL of the human CDCA7264-371 in complex with the nucleosome harboring a single hemimethylated CpG in the 3’-linker DNA was applied onto the glow-discharged holey carbon grids (Quantifoil Cu R1.2/1.3, 300 mesh). The grids were plunge-frozen in liquid ethane using a Vitrobot Mark IV (Thermo Fisher Scientific) ...
-
bioRxiv - Cell Biology 2024Quote: Vitrified grids were prepared by applying 3 µl of 1 uM complex sample to a freshly glow- discharged holey carbon grids (Quantifoil R1.2/1.3 Au 200 mesh). The sample was blotted for 3-5 s at 4 ℃ with 100% humidity and plunged-frozen in liquid nitrogen cooled ethane (FEI TM ...
-
bioRxiv - Biochemistry 2022Quote: ... An aliquot of 3.5 μl of sample was placed on the glow-discharged cryo-EM grid (Quantifoil R1.2/1.3 or Quantifoil R2/1), blotted and plunge-frozen in liquid ethane using a Mark VI Vitrobot instrument maintained at 100% humidity with blot force 20 and blot time of 3 seconds ...
-
bioRxiv - Biochemistry 2021Quote: ... 3.5 μl of the freshly purified sample from the peak fraction in DDM at ~2.0 mg/ml for the B.1.1.7 protein or ~1.5 mg/ml for the B.1.351 protein was applied to a 1.2/1.3 Quantifoil grid (Quantifoil Micro Tools GmbH), which had been glow discharged with a PELCO easiGlow™ Glow Discharge Cleaning system (Ted Pella ...
-
bioRxiv - Biochemistry 2022Quote: ... Three μL of sample at 5 μM was adsorbed onto glow-discharged copper Quantifoil R2/1 holey carbon grids (Quantifoil). Grids were glow discharged 45 seconds at 25 mA using an EMITECH K950 apparatus ...
-
bioRxiv - Microbiology 2024Quote: The total 2.5 µL sample was applied to both sides of glow-discharged 400-mesh R1.2/1.3 Cu grids (Quantifoil, Jena, Germany). The grids were blotted for 14 s at a humidity of 100% at 8 °C and rapidly frozen in liquid ethane using a Vitrobot Mark IV (Thermo Fisher Scientific) ...
-
bioRxiv - Cell Biology 2023Quote: ... and 5% (w/v) glycerol was applied to a Quantifoil 300-mesh R1.2/1.3 grid (Quantifoil, Micro Tools GmbH, Germany), which had been pre-treated with glow discharge using Pelco EasiGlow immediately before use ...
-
bioRxiv - Biophysics 2023Quote: 3.5 µL of protein or lipid solution was applied onto a freshly glow-discharged carbon-coated copper mesh grid (Quantifoil). After 1 min ...
-
bioRxiv - Biochemistry 2023Quote: 3.5 µL of sample were applied to a freshly glow discharged 200-mesh Au R1.2/1.3 grid (Quantifoil Micro Tools), incubated for 5 s ...
-
bioRxiv - Biophysics 2024Quote: ... 3 µL of purified AE1 at 5 mg/mL was added to a glow discharged (PELCO easiGlow) 0.6/1 µm holey gold grid (Quantifoil UltrAuFoil) and blotted for 4-6 s at 4°C and 100% humidity using the Vitrobot Mark IV system (Thermofisher Scientific) ...