Labshake search
Citations for Quantifoil Micro Tools :
251 - 300 of 719 citations for 2 Methyl 3 pyrrol 1 yl benzoic acid since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biophysics 2024Quote: ... 2 μL of 2 μM taxol-microtubules were incubated on a glow-discharged holey carbon cryo-EM grid (QuantiFoil, Au 300 R 1.2/1.3) for 30 seconds ...
-
bioRxiv - Microbiology 2020Quote: ... Quantifoil Cu R2/2 Finder grids (Quantifoil Micro Tools GmbH) were glow-discharged at 15mA for 1min ...
-
bioRxiv - Biophysics 2020Quote: UltrAuFoil R2/2 200 mesh TEM grids (Quantifoil Micro Tools) were prepared by 200 second glow discharge in 0.39 mBar of room air using a Pelco easiGlow (Ted Pella) ...
-
bioRxiv - Molecular Biology 2020Quote: Quantifoil R2/2 holey carbon copper grids (Quantifoil Micro Tool) were prepared by first applying an additional thin layer of continuous carbon and then glow-discharging them for 15 sec at 15 mA using an easiGlow Discharge cleaning system (PELCO) ...
-
bioRxiv - Biochemistry 2021Quote: Quantifoil R2/2 holey carbon copper grids (Quantifoil Micro Tool) were prepared by applying an additional thin layer of continuous carbon ...
-
bioRxiv - Molecular Biology 2022Quote: ... either carbon on Cu/Rh (Quantifoil R2/2 200 mesh) or gold on gold UltrAuFoil R1.2/1.3 300 mesh ...
-
bioRxiv - Biochemistry 2022Quote: Standard holey carbon grids (Quantifoil, Cu 200 mesh, R2/2) were glow discharged for 30 s at 15 mA on the negative setting ...
-
bioRxiv - Immunology 2024Quote: Quantifoil R2/2 holey carbon copper grids (Quantifoil, Grosslöbichau, Germany) were cleaned by overnight incubation in ethyl acetate and coated with 1 nm continuous carbon foil by floatation ...
-
bioRxiv - Physiology 2021Quote: ... 3 µL of the vortexed dispersion were placed on glow discharged carbon-coated grids (Quantifoil, D) for 1 minute ...
-
bioRxiv - Biophysics 2023Quote: ... 3 μl of the sample was applied to a hydrophilized grids (Quantifoil, R1.2/1.3+2nm carbon) with an additional 2 nm layer of amorphous carbon ...
-
bioRxiv - Plant Biology 2023Quote: ... 3 μl protein was applied to glow-discharged carbon grids (Quantifoil Cu R1.2/1.3 300 mesh). Subsequently ...
-
bioRxiv - Biophysics 2024Quote: ... 3 μl sample were applied individually to electron microscopy grids (Quantifoil, 400 mesh Au 1.2/1.3) that were glow discharged for 40 s using Gatan SOLARUS ...
-
bioRxiv - Biochemistry 2024Quote: ... 3 µL of purified protein was applied to an UltrAuFoil® R 1.2/1.3 grid (Quantifoil) that had been glow-discharged for 1 minute and 45 seconds ...
-
bioRxiv - Biophysics 2024Quote: ... 3 µl of the solution was then added to a glow- discharged ultrafoil gold grid (Quantifoil 2/2 ...
-
bioRxiv - Biophysics 2024Quote: ... 3 ul sample was applied onto glow-discharged R1.2/1.3 300 mesh UltrAuFoil gold grids (Quantifoil) (Russo and Passmore ...
-
bioRxiv - Molecular Biology 2021Quote: ... 3.5 μL was applied to a glow-discharged Quantifoil copper grid with 2 nm continuous carbon support over holes (Quantifoil R 2/4 400 mesh), blotted ...
-
bioRxiv - Biochemistry 2022Quote: ... or AE1-Niflumic acid at 5 mg/ml were applied to glow-discharged holey carbon EM grids (Quantifoil 300 copper mesh, R1.2/1.3) in an EM-GP2 plunge freezer (Leica) ...
-
bioRxiv - Biophysics 2020Quote: Quantifoil grids (200 mesh Au R2/2 and Au Finder; Quantifoil Micro Tools GmbH ...
-
bioRxiv - Microbiology 2022Quote: ... EM grids (R2/2, Cu 200 mesh; Quantifoil Micro Tools GmbH) were glow-discharged for 45 sec at 25 mA by PELCO easiGlow discharger ...
-
bioRxiv - Molecular Biology 2021Quote: ... UltrAuFoil (Russo and Passmore, 2014) R2/2 200 mesh grids (Quantifoil) were glow discharged for 15 s at 30 mA in a Quorum SC7620 ...
-
bioRxiv - Biochemistry 2023Quote: ... Holey carbon R2/2 300 mesh grids (Quantifoil Micro Tools GmbH) were glow-discharged for 90 sec at 25 mA using a PELCO easiGlow glow discharge cleaning system ...
-
bioRxiv - Microbiology 2022Quote: ... Gold quantifoil R2/2 200 mesh grids (Quantifoil Micro Tools GmbH) were sterilised with 70% ethanol and placed in glass bottomed MatTek dishes (MatTek Corporation ...
-
bioRxiv - Microbiology 2024Quote: Cryo-EM gold grids (Quantifoil R2/2 Au 200 mesh, Quantifoil) were placed in the slots of a custom-made PDMS stencil (Alvéole ...
-
bioRxiv - Microbiology 2024Quote: Cryo-EM gold grids (Quantifoil R2/2 Au 200 mesh, Quantifoil) were placed in the slots of a custom-made PDMS stencil (Alvéole ...
-
bioRxiv - Biophysics 2024Quote: ... 2-4 chameleon self-wicking grids (Quantifoil Active 300 mesh; Quantifoil) were loaded into the instrument and glow discharged for 40-45 seconds at 12 mA ...
-
bioRxiv - Biophysics 2024Quote: ... 2-4 chameleon self-wicking grids (Quantifoil Active 300 mesh; Quantifoil) were loaded into the instrument and glow discharged for 40-45 seconds at 12 mA ...
-
bioRxiv - Biochemistry 2024Quote: Quantifiol R 1.2/1.3 Au 400 mesh 2 nm Carbon (Quantifoil) were glow discharged at 0.2 atm for 30 s and were loaded onto a FEI vitrobot (Thermo Fisher) ...
-
bioRxiv - Molecular Biology 2020Quote: 3 μL of sample was applied onto a holey carbon grid (Quantifoil, Cu, R1.2/1.3, 300 mesh) rendered hydrophilic by a 30 s glow-discharge in air (11 mA current with PIB-10) ...
-
bioRxiv - Plant Biology 2021Quote: Concentrated PSII solution (3 µl) was applied on glow-discharged holey carbon grids (Cu Quantifoil R1.2/1.3) that were vitrified for cryo-EM structural determination using a Vitrobot FEI (3 s blot at 4°C and 100% humidity) ...
-
bioRxiv - Molecular Biology 2022Quote: ... The sample (3 μL) was applied to freshly glow-discharged Au 300 mesh R1.2/1.3 grids (Quantifoil) in a Vitrobot Mark IV (FEI ...
-
bioRxiv - Biophysics 2021Quote: ... 3 μL was applied to Ultrafoil grids (R1.2/1.3, Au/Au, 300 mesh, Quantifoil Micro Tools GmbH) that had been glow-discharged for 2 min using a Pelco easiGlow (Ted Pella ...
-
bioRxiv - Pharmacology and Toxicology 2022Quote: Samples (3 µL) were applied to glow-discharged Quantifoil R1.2/1.3 Cu/Rh 200 mesh grids (Quantifoil) (M4R-Gi1-Ipx and M4R-Gi1-Ipx-LY298 ...
-
bioRxiv - Biochemistry 2023Quote: ... 3 μl diluted protein sample was put on freshly glow-discharged Quantifoil R1.2/1.3 Cu grid (Quantifoil Micro Tools GmbH ...
-
bioRxiv - Biophysics 2023Quote: ... 3 µL sample was applied to a freshly glow-discharged UltrAuFoil R1.2/1.3 300 mesh grids (Quantifoil), blotted with Whatman No ...
-
bioRxiv - Biochemistry 2024Quote: Ternary complex sEGFR-Ex3HL/LH-CD3γε (3 µL) was applied to Quantifoil R1.2/1.3 Cu girds (Quantifoil) that had been glow discharged at 10 mA for 40 seconds with a sputter coater (JEOL JEC-3000FC) ...
-
bioRxiv - Biophysics 2024Quote: ... 3 μL were adsorbed to glow-discharged holey carbon-coated grids (Quantifoil 300 mesh, Cu R1.2/1.3). were then blotted for 3 to 6 s at 100% humidity (4 °C ...
-
bioRxiv - Biochemistry 2024Quote: ... 3 μL of alpha synuclein fibrils were applied to the glow-discharged holey carbon Cu grids (Quantifoil) and blotted with filter paper using Vitrobot Mark IV (FEI Company) ...
-
bioRxiv - Biochemistry 2024Quote: 4 μl of the inhibition reaction mixture was applied onto plasma cleaned holey carbon grids coated with 2nm thick amorphous carbon (Quantifoil R 2/2, UT, 300 Mesh, Copper). Following 30 sec of incubation inside the chamber of FEI Vitrobot MK IV (FEI ...
-
bioRxiv - Biochemistry 2024Quote: ... Those nucleosomes that passed the quality control were then loaded into a freshly glow discharged holey carbon golden grid (Quantifoil™ R 2/2 on 300 gold mesh) (2.5 µg of nucleosome diluted in 40 mM NaCl reconstitution buffer in 3 μl was loaded in the grid) ...
-
bioRxiv - Microbiology 2021Quote: ... 3 μl of each sample was dispensed on Quantifoil R1.2/1.3 200-mesh grids (Quantifoil Micro Tools GmbH) that had been freshly glow discharged for 30 seconds at 20 mA using a PELCO easyGLow™ Glow Discharge Cleaning System (Tedpella) ...
-
bioRxiv - Immunology 2022Quote: ... 3 μl of sample was then dispensed on Quantifoil R1.2/1.3 200-mesh grids (Quantifoil Micro Tools GmbH) that had been freshly glow discharged for 30 s at 20 mA ...
-
bioRxiv - Biochemistry 2022Quote: ... 3 µl of TIR-SAVED complex was applied to Holey Carbon grids (Quantifoil Cu R1.2/1.3, 300 mesh), glow discharged for 45 s at current of 45 mA in a EMITECH K100X glow discharger ...
-
bioRxiv - Molecular Biology 2020Quote: A 3 μL sample solution was applied to a Quantifoil holey carbon grid R1.2/1.3 Mo 200 mesh (Quantifoil Micro Tools GmbH ...
-
bioRxiv - Neuroscience 2021Quote: ... Aliquots of 3 μl were applied to glow-discharged holey carbon grids (Quantifoil Au R1.2/1.3, 300 mesh) and plunge-frozen in liquid ethane using a Thermo Fisher Vitrobot Mark IV ...
-
bioRxiv - Biochemistry 2021Quote: ... A 3-μl aliquot was pipetted on a holey carbon cryo-EM grid (1.3/1.2 Cu 200 mesh, Quantifoil) and vitrified by plunge-freezing in liquid ethane (Vitrobot Mark IV ...
-
bioRxiv - Immunology 2021Quote: ... 3 μl of sample was then dispensed on Quantifoil R1.2/1.3 200-mesh grids (Quantifoil Micro Tools GmbH) that had been freshly glow discharged for 30 s at 20 mA ...
-
bioRxiv - Biophysics 2021Quote: ... 3 μl sample was applied to each side of the UltrAuFoil grid (300 mesh, R 1.2/1.3, Quantifoil), which had been glow discharged on both sides (25 mA ...
-
bioRxiv - Molecular Biology 2022Quote: ... 4 µl of DELE WT CTD sample at 3 mg/ml was applied onto 300 mesh R1.2/1.3 UltraAuFoil holey gold grids (Quantifoil) that were plasma cleaned for 15 s using Pelco glow discharge cleaning system (Ted Pella ...
-
bioRxiv - Biophysics 2022Quote: ... A total of 3 µl of the solution was applied to freshly glow discharged R2.2 Cu300 grids (Quantifoil), blotted from the back side for 1.2s at 20°C and 99% humidity and immediately plunge frozen in liquid ethane using a Leica EM GP ...
-
bioRxiv - Immunology 2023Quote: ... 3 μL of the purified complex (8 mg/ml) was deposited onto a glow-discharged holey grid (Quantifoil Au 300 mesh R1.2/1.3 ...