Labshake search
Citations for Quantifoil Micro Tools :
201 - 250 of 730 citations for 5 Pyrimidinecarbonitrile 1 2R 2 3 dihydroxypropyl 1 2 3 4 tetrahydro 3 methyl 2 4 dioxo 9CI since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Molecular Biology 2022Quote: The purified complex samples (3 μL at 5-8 mg/mL) were applied to glow-discharged holey grids (Quantifoil R1.2/1.3, 300 mesh) and subsequently vitrified using a Vitrobot Mark IV (ThermoFisher ...
-
bioRxiv - Neuroscience 2024Quote: ... Supernatant after centrifugation mixed with 10-nm gold beads solution (Aurion, cat # 25486) at 1:1 ratio was added to the mounted grid (Quantifoil R2/2 Cu 200 EM). No other chemicals or stimulation were applied prior to plunge freezing ...
-
bioRxiv - Biophysics 2022Quote: Cryo-EM grids were prepared by applying 3 μL of sample (at the native 1 nM concentration) on glow discharged holey gold grids (Quantifoil Cu 1.2/1.3 400 mesh). Excess sample was removed by blotting with filter paper for 4 sec prior to plunge-freezing in liquid ethane using a FEI Vitrobot Mark IV at 100% humidity and 4 °C ...
-
bioRxiv - Molecular Biology 2020Quote: Cryo-EM grids were prepared by applying 3 µL sample (at a protein concentration of 1 mg/ml) on glow-discharged holey gold grids (Quantifoil Au 1.2/1.3 300 mesh). Excess sample was removed by blotting with filter paper for 2-3 s before plunge-freezing in liquid ethane (cooled to −181 °C ...
-
bioRxiv - Biophysics 2022Quote: ... 10 µl sample was applied onto a glow discharged copper grid coated with holey carbon (R 2/2; Quantifoil, Jena, Germany), and subsequently dipped onto 500 µl deionized H2O for 1 second to clear the sucrose ...
-
bioRxiv - Microbiology 2023Quote: CryoEM samples were prepared by applying 5 μL aliquots of purified PLE PLPs to R2/2 Quantifoil grids and R2/2 Quantifoil grids coated with 2nm ultrathin Carbon (QUANTIFOIL®) that had been glow discharged for 45 seconds in a Pelco Easiglow glow discharging unit ...
-
bioRxiv - Biochemistry 2024Quote: ... of the freshly eluted complex peak solution (4.0 mg/mL) was loaded onto glow-discharged holey carbon grids (Quantifoil 2/2). The procedures for blotting and plunge freezing the grids were the same as above ...
-
bioRxiv - Microbiology 2022Quote: ... the amoebae (5×105 per well) were seeded onto EM gold finder grids (Au NH2 R2/2, Quantifoil) and incubated for 1 h ...
-
bioRxiv - Cell Biology 2020Quote: All samples were imaged on carbon coated 3 mm gold EM finder grids (Quantifoil). Bead test and calibration samples were made by adding 2 µl of 175 nm fluorescent bead solution(Thermo Fisher PS-Speck) ...
-
bioRxiv - Biochemistry 2020Quote: ... 3 μL of the concentrated RdRp-RNA complex were mixed with 0.5 μl of octyl ß-D-glucopyranoside (0.003% final concentration) and applied to freshly glow discharged R 2/1 holey carbon grids (Quantifoil). The grids were blotted for 5 seconds using a Vitrobot MarkIV (Thermo Fischer Scientific ...
-
bioRxiv - Biochemistry 2021Quote: ... 3 µL of the concentrated RdRp-RNA complex were mixed with 0.5 µl of octyl ß-D-glucopyranoside (0.003% final concentration) and applied to freshly glow discharged R 2/1 holey carbon grids (Quantifoil). The grids were blotted for 7 seconds with blot force 5 using a Vitrobot MarkIV (Thermo Fischer Scientific ...
-
bioRxiv - Biophysics 2020Quote: ... 3 μL of the concentrated RdRp-RNA complex were mixed with 0.5 μl of octyl ß-D-glucopyranoside (0.003% final concentration) and applied to freshly glow discharged R 2/1 holey carbon grids (Quantifoil). Prior to flash freezing in liquid ethane ...
-
bioRxiv - Molecular Biology 2020Quote: ... a 2.2-µL aliquot of this sample was applied to a plasma cleaned holey carbon grid (R2/1, 200 mesh; Quantifoil) or Graphene Oxide-Lacey Carbon grid (300 mesh ...
-
bioRxiv - Biophysics 2020Quote: ... Mycoplasma pneumoniae strain M129(ATCC 29342)cells were grown on 200 mesh gold grids coated with a holey carbon support (R 2/1, Quantifoil). Cells were cultivated at 37 °C in modified Hayflick medium ...
-
bioRxiv - Microbiology 2022Quote: ... and 4 µl of the mixture was applied to a glow-discharged holey-carbon copper EM grid (R2/1 or R2/2, Quantifoil). The grid was automatically blotted from the backside for 4-6 s in a Mark IV Vitrobot by using a Teflon sheet on the front pad ...
-
bioRxiv - Microbiology 2022Quote: ... mixed with 10 nm protein A-coated colloidal gold (Aurion) and applied onto a glow-discharged EM grid (200 mesh, R 2/1, Quantifoil) prior to plunge-freezing with a Leica EM GP2 automatic plunge-freezer.
-
bioRxiv - Cell Biology 2023Quote: Cells were blotted on EM grids (R 2/1 holey carbon 200 films on Cu 200 mesh, Quantifoil Micro Tools). The grids were first glow-discharged and 4 µl of trypanosome wild-type culture (2-4 · 107 cells/ml ...
-
bioRxiv - Microbiology 2023Quote: ... and 4 µl of the mixture was applied to a glow-discharged holey-carbon copper EM grid (R2/1 or R2/2, Quantifoil). The grid was automatically backside blotted for 4-6s in a Mark IV Vitrobot (Thermo Fischer Scientific ...
-
bioRxiv - Biophysics 2023Quote: ... HeLa cells were trypsinized and seeded at a density of 0.5 – 0.7 X 105 cells/mL on carbon-coated gold Quantifoil grid (200 mesh, R 2/1, holey SiO2 film; Quantifoil Micro Tools GmbH ...
-
bioRxiv - Biochemistry 2024Quote: ... using 3 µL of the samples applied to previously glow discharged R 2/1 Holey Carbon Cu 200 mesh EM grids (Quantifoil). Samples were 10 µM FtsZ with or without ZapD or mZapD at different concentrations specified in each case (0 – 60 µM) ...
-
bioRxiv - Biophysics 2021Quote: ... before applying 4 µL of the solution to a glow-discharged (30s at 35 mA) copper R 2/2 200-mesh holey carbon grid (Quantifoil Micro Tools). The grids were blotted manually from the back side with Whatman filter paper #1 for 2-4 s ...
-
bioRxiv - Molecular Biology 2019Quote: ... Three microliters of polymerised sample were applied onto R 2/2 holey carbon support film on a 300-mesh copper EM sample grid (Quantifoil Micro Tools), which had been glow discharged immediately prior to use ...
-
bioRxiv - Cell Biology 2022Quote: ... Thin sections of 50μm were obtained using a vibratome and placed onto a glow discharged electron microscopy grid (UltrAuFoil, 200 Au mesh, 2/2 Au film (Quantifoil Micro Tools)) that had been pre-clipped into Autogrids (Thermo Fisher Scientific) ...
-
bioRxiv - Cell Biology 2022Quote: ... A flat-sided planchette was placed flat side upwards and a glow discharged (Glocube, Quorum, Lewes, UK) electron microscopy grids (UltraAuFoil, 200 Au mesh, 2/2 Au film (Quantifoil Micro Tools) placed on top ...
-
bioRxiv - Molecular Biology 2023Quote: ... and samples for cryo-SPA were deposited onto 200-mesh holey carbon grids (Quantifoil Micro Tools, R 2/2 X-103-Cu200) which were first glow-discharged for 2.5 min using an ELMO glow discharge unit (Cordouan Technologies) ...
-
bioRxiv - Microbiology 2020Quote: ... loaded onto glow-discharged carbon grids (R2/2, Quantifoil) and plunge-frozen into liquid ethane-propane mix cooled at liquid nitrogen temperatures with a Mark IV Vitrobot(Thermo Fisher Scientific ...
-
bioRxiv - Microbiology 2021Quote: EM grids (G300F1, R2/2 Quantifoil holey carbon, gold) were glow-discharged and treated with bovine fibronectin (20 μg/ml ...
-
bioRxiv - Microbiology 2020Quote: ... loaded onto glow-discharged carbon grids (R2/2, Quantifoil) and plunge-frozen into liquid ethane-propane mix cooled at liquid nitrogen temperatures with a Mark IV Vitrobot maintained at room temperature and 70% humidity ...
-
bioRxiv - Microbiology 2020Quote: ... loaded onto glow-discharged carbon grids (R2/2, Quantifoil) and plunge-frozen into liquid ethane-propane mix cooled at liquid nitrogen temperatures with a FEI Mark IV Vitrobot maintained at room temperature and 70% humidity ...
-
bioRxiv - Cell Biology 2021Quote: Carbon-coated gold TEM grids (Quantifoil NH2A R2/2) were glow-discharged at 2 mA and 1.5–1.8 × 10-1 m bar for 1 min in an ELMO (Cordouan ...
-
bioRxiv - Biochemistry 2022Quote: UltrAuFoil on gold 200 mesh R2/2 grids (Quantifoil) were subjected to micropatterning using the Primo module from Alveole mounted on a Leica DMi8 microscope following the manufacturer procedure ...
-
bioRxiv - Microbiology 2022Quote: ... loaded onto glow discharged carbon grids (R2/2, Quantifoil) and plunge-frozen using a Vitrobot Mark IV (ThermoFisher Scientific) ...
-
bioRxiv - Cell Biology 2023Quote: Carbon-coated gold TEM grids (Quantifoil NH2A R2/2) were glow-discharged at 2 mA and 1.5– × 10−1 m bar for 1 minute in an ELMO (Cordouan ...
-
bioRxiv - Biophysics 2024Quote: ... Holey carbon grids (Quantifoil Cu 300 mesh, R2/2) were prepared with fiducials by glow-discharging ...
-
bioRxiv - Biochemistry 2024Quote: ... Quantifoil Cu 200 R2/2 holey carbon grids (Quantifoil) were glow discharged negatively for 45 sec before sample application ...
-
bioRxiv - Biophysics 2020Quote: The cell suspension in sea water was seeded onto R 2/2 (SiO2) on Au G200F1 finder grids (Quantifoil Micro Tools GmbH, Germany) and incubated with filtered fresh sea water at 18 °C overnight ...
-
bioRxiv - Biochemistry 2022Quote: ... Qualified nucleosomes were then loaded in a freshly glow discharged holey carbon golden grid (Quantifoil™ R 2/2 on 300 gold mesh) (1.0-2.5 µg of nucleosomes were diluted in 40 mM NaCl reconstitution buffer in 3 μL) ...
-
bioRxiv - Molecular Biology 2023Quote: ... The complex was incubated at RT for 20 mins and pipetted onto glowed discharged cryo-EM grids (Quantifoil R 2/2 Au 300). Grids were frozen in liquid ethane by using a Vitrobot Mark IV (ThermoFischer ...
-
bioRxiv - Molecular Biology 2022Quote: ... Samples (3 μl) were applied to Quantifoil 1.2/1.3 Cu 300 holey-carbon grids (Quantifoil) glow-discharged 60 s using a PELCO glow-discharge system (Ted Pella) ...
-
bioRxiv - Cell Biology 2022Quote: ... 3 μl of the resulting mixture was spotted onto glow-discharged copper EM grids (Quantifoil 300 Au mesh ...
-
bioRxiv - Microbiology 2021Quote: ... 4-7 µl of cells were deposited on R2/1 Cu 200 grids (Quantifoil) that had been glow-discharged for 1 min at 0.19 mbar and 20 mA in a PELCO easiGlow device shortly before use ...
-
bioRxiv - Cell Biology 2022Quote: ... Cells were then seeded onto gold grids (either ‘UltrAuFoil’ 200 Au mesh, R2/2 gold film, or Quantifoil 300 Au mesh, R2/2 carbon film (Quantifoil Micro Tools, Großlöbichau, Germany) and grown to 50 % confluency before plunge freezing ...
-
bioRxiv - Biochemistry 2023Quote: ... An aliquot (2 μL) of this polarized vesicle solution was applied onto a glow-discharged holey gold grid (Quantifoil Au R2/2, 400 mesh). After incubating the sample on the grid for 3 minutes at 10 °C with a humidity of 100% ...
-
bioRxiv - Microbiology 2020Quote: ... Quantifoil Cu R2/2 Finder grids (Quantifoil Micro Tools GmbH) were glow-discharged at 15mA for 1min ...
-
bioRxiv - Biophysics 2020Quote: UltrAuFoil R2/2 200 mesh TEM grids (Quantifoil Micro Tools) were prepared by 200 second glow discharge in 0.39 mBar of room air using a Pelco easiGlow (Ted Pella) ...
-
bioRxiv - Molecular Biology 2020Quote: Quantifoil R2/2 holey carbon copper grids (Quantifoil Micro Tool) were prepared by first applying an additional thin layer of continuous carbon and then glow-discharging them for 15 sec at 15 mA using an easiGlow Discharge cleaning system (PELCO) ...
-
bioRxiv - Biochemistry 2021Quote: Quantifoil R2/2 holey carbon copper grids (Quantifoil Micro Tool) were prepared by applying an additional thin layer of continuous carbon ...
-
bioRxiv - Molecular Biology 2022Quote: ... either carbon on Cu/Rh (Quantifoil R2/2 200 mesh) or gold on gold UltrAuFoil R1.2/1.3 300 mesh ...
-
bioRxiv - Biochemistry 2022Quote: Standard holey carbon grids (Quantifoil, Cu 200 mesh, R2/2) were glow discharged for 30 s at 15 mA on the negative setting ...
-
bioRxiv - Immunology 2024Quote: Quantifoil R2/2 holey carbon copper grids (Quantifoil, Grosslöbichau, Germany) were cleaned by overnight incubation in ethyl acetate and coated with 1 nm continuous carbon foil by floatation ...