bioRxiv - Biophysics 2024Quote: 3 μL of concentrated protein sample was applied to a glow-discharged (30 s at 15 mA) grid (Quantifoil Au or Cu R1.2/1.3 300 mesh) and after a wait time of 5 s ...
-
bioRxiv - Biochemistry 2024Quote: 3µl of the AtGDH-AKG bound binary complex (3 mg/ml) was applied to freshly glow-discharged holey carbon grids (Quantifoil Au R 0.6/1.0 300 mesh). For the apo form AnGDH dataset ...
-
bioRxiv - Molecular Biology 2020Quote: ... plain grids (Quantifoil 2/2) were transferred to the microscope ...
-
bioRxiv - Biophysics 2020Quote: ... 2.5 μl samples of GDN-purified proteins at a concentration of 1.5-3 mg ml−1 were applied to glow-discharged holey carbon grids (Quantifoil R1.2/1.3 or R0.6/1 Au 200 mesh). Excess liquid was removed in a controlled environment (4°C and 100% relative humidity ...
-
Genome modularization reveals overlapped gene topology is necessary for efficient viral reproductionbioRxiv - Synthetic Biology 2020Quote: A 4 μL solution of co-isolated small particles were applied to glow-discharged copper grids (Quantifoil R2/2, Quantifoil Micro Tools), blotting for 3-seconds at 4 °C with 90% humidity and plunging into liquid ethane using a Lecia EM GP device (Leica Microsystems ...
-
Genome modularization reveals overlapped gene topology is necessary for efficient viral reproductionbioRxiv - Synthetic Biology 2020Quote: A 4 μL solution of co-isolated small particles were applied to glow-discharged copper grids (Quantifoil R2/2, Quantifoil Micro Tools), blotting for 3-seconds at 4 °C with 90% humidity and plunging into liquid ethane using a Lecia EM GP device (Leica Microsystems ...
-
Mycobacteria form viable cell wall-deficient cells that are undetectable by conventional diagnosticsbioRxiv - Microbiology 2022Quote: ... of which 3-4 µL was applied on glow-discharged 200 mesh copper grids with an extra thick R2/2 carbon film (Quantifoil Micro Tools). Vitrification was performed using an automated Leica EM GP plunge-freezer ...
-
bioRxiv - Biochemistry 2024Quote: Grids for cryo-EM were prepared by applying 4 µL of sample on a glow-discharged Quantifoil 300 mesh Cu 2/1 grid (Quantifoil Micro Tools), blotting for 7.5 seconds ...
-
bioRxiv - Biochemistry 2024Quote: ... carbon-coated (Quantifoil R 2/2) 200-mesh copper grids (Electron Microscopy Sciences ...
-
bioRxiv - Synthetic Biology 2021Quote: ... 25 mM Tris at pH 8.0 to a concentration of 2 mg/mL to a glow-discharged (1 min at 5 mA) holey carbon grid (Quantifoil Q225-CR1.3). This was followed by plunge-freezing in liquid ethane using an FEI Vitribot Mark IV (100% humidity ...
-
bioRxiv - Cell Biology 2020Quote: ... Cells were incubated at 37°C and 5% CO2 for 16h prior to trypsinization and seeding onto 200 mesh gold holey carbon grids (R2/2-2C; Quantifoil Micro Tools), which were placed in 3D printed grid holders [39] ...
-
bioRxiv - Cell Biology 2024Quote: ... An aliquot of a 5 μl sample was applied to a glow-discharged holey carbon grid (Quantifoil R2/2, Au, 400 mesh). After waiting for 60 s ...
-
bioRxiv - Biochemistry 2022Quote: ... holey copper grids (QUANTIFOIL R 2/2). 3.5-μl samples were adsorbed for 1 min at +20 °C ...
-
bioRxiv - Microbiology 2020Quote: Holey carbon-coated (R 2/2; Quantifoil) Au-G200F1 grids were analyzed in cryo-conditions by MISTRAL microscope at ALBA synchrotron ...
-
bioRxiv - Molecular Biology 2021Quote: ... 4 μl of protein sample (about 0.73 mg/ml) was applied onto a glow-discharged holey carbon grid (Quantifoil Au, R2/2, 300 mesh). After blotting for 3 s ...
-
bioRxiv - Biophysics 2021Quote: To provide extra support for cell growth 5-6 nm of carbon was evaporated onto Quantifoil Au 200 R2/1 or R2/2 grids (Quantifoil Micro Tools GmbH). Grids were then glow discharged and incubated in supplemented RPMI-1640 overnight in the cell incubator ...
-
bioRxiv - Biophysics 2022Quote: Purified wt or mutant D263A or F55A MVMp capsid samples (5 μl) were applied onto R2/2 300 mesh copper grids (Quantifoil Micro Tools, Germany) and vitrified using a Leica EM CPC cryofixation unit ...
-
bioRxiv - Microbiology 2022Quote: ... 5 µL of the mixture was placed onto freshly glow discharged holey carbon grids (Quantifoil™ R 2/1 on 200 copper mesh) for 1 minute ...
-
bioRxiv - Cell Biology 2024Quote: ... An aliquot of 3.5 μl of the crude membrane sample was deposited onto freshly glow-discharged Quantifoil R2/2 200-mesh grids (Quantifoil Micro Tools GmbH,) using the Leica EM GP (Leica Microsystems ...
-
bioRxiv - Cell Biology 2024Quote: ... An aliquot of 3.5 μl of sample was applied to freshly glow-discharged copper Quantifoil R2/2 200-mesh London Finder grids (Quantifoil Micro Tools GmbH) and then plunge frozen using a Leica EM GP plunger (Leica Microsystems ...
-
bioRxiv - Biochemistry 2020Quote: ... 3 µl of sample were applied to glow-discharged Quantifoil Au 2/2 holey carbon 200 mesh grids or Ultrafoil Au 2/2 holey gold 200 mesh grids (Quantifoil), and flash frozen in liquid ethane using an FEI Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Molecular Biology 2023Quote: A QuantiFoil 300-mesh R 2/2 grid with 2 nm continuous carbon (QuantiFoil Micro Tools GmbH ...
-
bioRxiv - Biochemistry 2020Quote: UltrAUfoil 2/2 300 mesh gold grids (Quantifoil) were used for open hole data collection (Dataset 1) ...
-
bioRxiv - Microbiology 2020Quote: ... A small volume (4 µL) of cells was then transferred onto freshly glow‐discharged copper R2/2 200 Quantifoil holey carbon grids (Quantifoil Micro Tools GmbH, Jena, Germany). Grids were then blotted and plunge‐frozen in a liquid ethane/propane mixture 31 using an FEI Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Biophysics 2020Quote: ... or QUANTIFOIL R 2/2 holey carbon grids (Quantifoil Micro Tools GmbH ...
-
bioRxiv - Biophysics 2022Quote: ... holey carbon grid coated with 2 nm ultrathin carbon film (Quantifoil 300-mesh, R 2/2). After waiting for 60 s ...
-
bioRxiv - Biochemistry 2021Quote: Holey grids (gold, 200 mesh, r 2/2 by Quantifoil) were glow-discharged for 30 seconds using a Pelco glow discharge system ...
-
bioRxiv - Biophysics 2024Quote: Holey carbon grids (Quantifoil Au R 2/2, 200 mesh) were glow-discharged with easiGlow at 20 mA for 45 s ...
-
bioRxiv - Biophysics 2023Quote: ... split onto Poly-D-Lysine coated R 2/2 grids (QUANTIFOIL 100 Holey Carbon Films ...
-
bioRxiv - Immunology 2024Quote: ... The sample was prepared on Quantifoil Cu 300 2/2 (Quantifoil) grids and was frozen in liquid ethane using the Vitroblot Mark IV (Thermo Fisher ...
-
bioRxiv - Plant Biology 2024Quote: 4 μL AtEDS1-AtPAD4-AtADR1 complex purified from Nb leaves was applied to glow-discharged Quantifoil holey carbon grids (Quantifoil Cu R1.2/1.3+2 nm C, 300 mesh). The protein was concentrated to 0.9 mg/mL prior to freezing ...
-
bioRxiv - Biophysics 2023Quote: ... glow discharged QUANTIFOIL® copper R 2/2 grid with a 2 nm thin extra carbon layer (QUANTIFOIL, GMBH) was used ...
-
bioRxiv - Biochemistry 2021Quote: ... Quantifoil Cu 300 mesh (R 2/2 geometry; Quantifoil Micro Tools GMBH) covered with a thin layer of 3 nm carbon were used for the for the GTPBP5KO sample ...
-
bioRxiv - Biochemistry 2022Quote: R2/2 grids (Quantifoil) were covered with a thin layer of continuous carbon (estimated to be 50 Å thick ...
-
bioRxiv - Microbiology 2024Quote: ... Continuous carbon grids (Quantifoil R 2/2 on Cu 300 mesh grids + 2 nm Carbon, Quantifoil Micro Tools C2-C16nCu30-01) were glow-discharged for 5 sec in an easiGlow Glow Discharge Cleaning System (Ted Pella Inc.) ...
-
bioRxiv - Biochemistry 2022Quote: ... Continuous carbon grids (Quantifoil R 2/2 on Cu 300 mesh grids + 2 nm Carbon, Quantifoil Micro Tools C2-C16nCu30-01) were glow-discharged for 5 sec in an easiGlow Glow Discharge Cleaning System (Ted Pella Inc.) ...
-
bioRxiv - Molecular Biology 2022Quote: ... Glow-discharged carbon coated gold mesh grids (QF 2/2 AU 200, Quantifoil) were placed on the edge of the glass microscopy slides ...
-
bioRxiv - Neuroscience 2020Quote: ... covered with either 2 nm amorphous carbon (Quantifoil, R2/1+2 nm C) or graphene were used for sample preparation ...
-
bioRxiv - Bioengineering 2022Quote: ... holey carbon grids (Ultrafoil 25 nM Au R 2/2 200 mesh; Quantifoil) were glow-discharged for 10 s using the Solarus plasma cleaner (Gatan) ...
-
bioRxiv - Biochemistry 2023Quote: ... Cryo-EM grids (carbon-coated Quantifoil R 2/2 cupper grids, 300 mesh) were plunge-frozen using a Vitrobot IV (Thermo Fisher Scientific ...
-
bioRxiv - Biochemistry 2023Quote: ... the same proteins were applied to holey grids with a 2 nm carbon film (Quantifoil Cu 2/2 200 mesh from EMS). Samples were frozen after a total of 145 min on the grids without carbon film and 150 min on the grids with carbon film ...
-
bioRxiv - Biochemistry 2021Quote: ... the samples (3.5 μl) were applied onto UltraAuFoil R 2/2 gold grids (Quantifoil Micro Tools GMBH ...
-
bioRxiv - Molecular Biology 2024Quote: A QuantiFoil 200-mesh R 2/1 grid with 2 nm continuous carbon (QuantiFoil Micro Tools GmbH ...
-
bioRxiv - Cell Biology 2021Quote: Gold grids (Quantifoil, R2/2) were glow-discharged and incubated on top of 40 μL droplets of fibronectin (50 μg/mL ...
-
bioRxiv - Biochemistry 2024Quote: ... R2/2 UltrAuFoil grids (Quantifoil) were glow-discharged for 100 s ...
-
bioRxiv - Biochemistry 2024Quote: ... R2/2 UltrAuFoil grids (Quantifoil) were glow-discharged for 100 s ...
-
bioRxiv - Cell Biology 2020Quote: ... or holey SiO2 R1/4 TEM grids (Quantifoil) to allow for more robust correlation and cells were plunge frozen on a Vitrobot Mark IV (FEI ...
-
bioRxiv - Cell Biology 2022Quote: ... Grids (200 Mesh Cu SiO2 R1/4, Quantifoil) were plasma cleaned for 30 s before plunging ...
-
bioRxiv - Biophysics 2024Quote: ... 2 μL of 2 μM taxol-microtubules were incubated on a glow-discharged holey carbon cryo-EM grid (QuantiFoil, Cu 300 R 2/1) for 30 seconds ...
-
bioRxiv - Microbiology 2024Quote: ... 3 μL of purified viral particles at ∼1 mg/mL were applied during 2 min to glow-discharged Quantifoil R 2/2 grids covered with a thin carbon film (Quantifoil Micro tools GmbH, Germany), blotted for 3 s and then flash frozen in liquid ethane using the semi-automated plunge freezing device Vitrobot IV at 100% relative humidity ...