Labshake search
Citations for Quantifoil Micro Tools :
101 - 150 of 365 citations for L Valine 2 13C 99% since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Microbiology 2021Quote: EM grids (G300F1, R2/2 Quantifoil holey carbon, gold) were glow-discharged and treated with bovine fibronectin (20 μg/ml ...
-
bioRxiv - Microbiology 2020Quote: ... loaded onto glow-discharged carbon grids (R2/2, Quantifoil) and plunge-frozen into liquid ethane-propane mix cooled at liquid nitrogen temperatures with a Mark IV Vitrobot maintained at room temperature and 70% humidity ...
-
bioRxiv - Microbiology 2020Quote: ... loaded onto glow-discharged carbon grids (R2/2, Quantifoil) and plunge-frozen into liquid ethane-propane mix cooled at liquid nitrogen temperatures with a FEI Mark IV Vitrobot maintained at room temperature and 70% humidity ...
-
bioRxiv - Cell Biology 2021Quote: Carbon-coated gold TEM grids (Quantifoil NH2A R2/2) were glow-discharged at 2 mA and 1.5–1.8 × 10-1 m bar for 1 min in an ELMO (Cordouan ...
-
bioRxiv - Biochemistry 2022Quote: UltrAuFoil on gold 200 mesh R2/2 grids (Quantifoil) were subjected to micropatterning using the Primo module from Alveole mounted on a Leica DMi8 microscope following the manufacturer procedure ...
-
bioRxiv - Microbiology 2022Quote: ... loaded onto glow discharged carbon grids (R2/2, Quantifoil) and plunge-frozen using a Vitrobot Mark IV (ThermoFisher Scientific) ...
-
bioRxiv - Cell Biology 2023Quote: Carbon-coated gold TEM grids (Quantifoil NH2A R2/2) were glow-discharged at 2 mA and 1.5– × 10−1 m bar for 1 minute in an ELMO (Cordouan ...
-
bioRxiv - Biophysics 2024Quote: ... Holey carbon grids (Quantifoil Cu 300 mesh, R2/2) were prepared with fiducials by glow-discharging ...
-
bioRxiv - Biochemistry 2024Quote: ... Quantifoil Cu 200 R2/2 holey carbon grids (Quantifoil) were glow discharged negatively for 45 sec before sample application ...
-
bioRxiv - Microbiology 2024Quote: ... copper EM grids (Cu 200 R 2/1, Quantifoil) were used ...
-
bioRxiv - Plant Biology 2021Quote: 4 μl of GmQUAC1malate proteins (purified in 75 mM L-malate) were applied to newly glow-discharged holy carbon film grids (Au R1.2/1.3, 300 meshes, Quantifoil, Germany). The grids were blotted with force 3 and blotting time of 9.0 s at 100% humidity and 4°C and were vitrified by plunge freezing into liquid ethane using Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Molecular Biology 2020Quote: ... 4 μl of purified PA7LF3 at a concentration of ∼0.06 mg/ml was applied onto freshly glow discharged grids (Quantifoil R 1.2/1.3 holey carbon with a 2 nm additional carbon support ...
-
bioRxiv - Biophysics 2020Quote: The cell suspension in sea water was seeded onto R 2/2 (SiO2) on Au G200F1 finder grids (Quantifoil Micro Tools GmbH, Germany) and incubated with filtered fresh sea water at 18 °C overnight ...
-
bioRxiv - Biochemistry 2022Quote: ... Qualified nucleosomes were then loaded in a freshly glow discharged holey carbon golden grid (Quantifoil™ R 2/2 on 300 gold mesh) (1.0-2.5 µg of nucleosomes were diluted in 40 mM NaCl reconstitution buffer in 3 μL) ...
-
bioRxiv - Molecular Biology 2023Quote: ... The complex was incubated at RT for 20 mins and pipetted onto glowed discharged cryo-EM grids (Quantifoil R 2/2 Au 300). Grids were frozen in liquid ethane by using a Vitrobot Mark IV (ThermoFischer ...
-
bioRxiv - Cell Biology 2022Quote: The IL-11Δ10/IL-11RαD1-D3/gp130EC complex (1.5 mg/mL) in the presence of 1-2 mM n-dodecyl β-D-maltoside was blotted onto UltrAuFoil grids (R2/2, Quantifoil Micro Tools GmbH) that had been subjected to glow discharge (15 mA for 30 s) ...
-
bioRxiv - Cell Biology 2022Quote: ... Cells were then seeded onto gold grids (either ‘UltrAuFoil’ 200 Au mesh, R2/2 gold film, or Quantifoil 300 Au mesh, R2/2 carbon film (Quantifoil Micro Tools, Großlöbichau, Germany) and grown to 50 % confluency before plunge freezing ...
-
bioRxiv - Biophysics 2023Quote: ... 0.5 μL L-PEG-L (8 mg/ml) and 0.5 μL Pd(NO3)2 (1 mg/ml) was applied to holey carbon grid (Quantifoil 200 mesh Cu R2/2) which was glow discharged 45 s at 15 mA ...
-
bioRxiv - Biochemistry 2023Quote: ... An aliquot (2 μL) of this polarized vesicle solution was applied onto a glow-discharged holey gold grid (Quantifoil Au R2/2, 400 mesh). After incubating the sample on the grid for 3 minutes at 10 °C with a humidity of 100% ...
-
bioRxiv - Microbiology 2020Quote: ... Quantifoil Cu R2/2 Finder grids (Quantifoil Micro Tools GmbH) were glow-discharged at 15mA for 1min ...
-
bioRxiv - Biophysics 2020Quote: UltrAuFoil R2/2 200 mesh TEM grids (Quantifoil Micro Tools) were prepared by 200 second glow discharge in 0.39 mBar of room air using a Pelco easiGlow (Ted Pella) ...
-
bioRxiv - Molecular Biology 2020Quote: Quantifoil R2/2 holey carbon copper grids (Quantifoil Micro Tool) were prepared by first applying an additional thin layer of continuous carbon and then glow-discharging them for 15 sec at 15 mA using an easiGlow Discharge cleaning system (PELCO) ...
-
bioRxiv - Biochemistry 2021Quote: Quantifoil R2/2 holey carbon copper grids (Quantifoil Micro Tool) were prepared by applying an additional thin layer of continuous carbon ...
-
bioRxiv - Molecular Biology 2022Quote: ... either carbon on Cu/Rh (Quantifoil R2/2 200 mesh) or gold on gold UltrAuFoil R1.2/1.3 300 mesh ...
-
bioRxiv - Biochemistry 2022Quote: Standard holey carbon grids (Quantifoil, Cu 200 mesh, R2/2) were glow discharged for 30 s at 15 mA on the negative setting ...
-
bioRxiv - Immunology 2024Quote: Quantifoil R2/2 holey carbon copper grids (Quantifoil, Grosslöbichau, Germany) were cleaned by overnight incubation in ethyl acetate and coated with 1 nm continuous carbon foil by floatation ...
-
bioRxiv - Biochemistry 2021Quote: ... Samples were diluted twofold with Buffer F and 3.5 µl of sample was immediately applied onto a glow-discharged 300-mesh gold Quantifoil R1.2/1.3 grid (Quantifoil Micro Tools). Grids were blotted for 2-4 s and plunge-frozen in liquid ethane cooled by liquid nitrogen with a Vitrobot MarkIV (ThermoFisher ...
-
bioRxiv - Biophysics 2022Quote: ... 3 µl of DeCLIC sample was applied to a glow-discharged quantifoil 1.2/1.3 Cu 300 mesh grid (Quantifoil Micro Tools), which was then blotted for 1.5 s and plunge-frozen into liquid ethane using a FEI Vitrobot Mark IV ...
-
bioRxiv - Microbiology 2022Quote: ... 3.0 μL of above-described samples or non-treated CVA9 virions as a control were applied to glow-discharged grids (Quantifoil R1.2/1.3 holey carbon on 300 copper mesh ...
-
bioRxiv - Biochemistry 2021Quote: ... 2.5 μL of selected elution fractions were applied to a 300-mesh holey carbon grid (Au 1.2/1.3, Quantifoil Micro Tools), blotted 2 s at 75 % humidity ...
-
bioRxiv - Biochemistry 2023Quote: ... 2.8 µl of F-actin sample was applied to a glow-discharged R2/1 Cu 300 mesh holey-carbon grid (Quantifoil). Excess solution was blotted away and the grids were plunge frozen in liquid ethane or a liquid ethane/propane mixture using a Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Cell Biology 2024Quote: ... 4 μl of the cell suspension was applied onto a glow-discharged holey SiO2 grid (R1/4, Au, 200 mesh, Quantifoil) mounted on in the plunger chamber ...
-
bioRxiv - Molecular Biology 2021Quote: ... 3.5 μL was applied to a glow-discharged Quantifoil copper grid with 2 nm continuous carbon support over holes (Quantifoil R 2/4 400 mesh), blotted ...
-
bioRxiv - Microbiology 2021Quote: ... 3 μL of sample solution was applied to a Quantifoil holey carbon grid (R1.2/1.3, Mo 200 mesh, Quantifoil Micro Tools GmbH) at 4 °C with 100% humidity ...
-
bioRxiv - Microbiology 2020Quote: Three μl of purified HKU1 HE (4 mg/ml) was dispensed on Quantifoil R1.2/1.3 200-mesh grids (Quantifoil Micro Tools GmbH) that had been freshly glow discharged for 30 seconds at 20 mA using GloQube Glow Discharge system (Quorum Technologies) ...
-
bioRxiv - Microbiology 2023Quote: A 1.4 μl sample solution was applied onto a glow-discharged holey carbon grid (Quantifoil R1.2/1.3 Mo grid, Quantifoil Micro Tools, Germany), and the grid was plunge-frozen into liquid ethane by Vitrobot mark IV (Thermo Fisher Science ...
-
bioRxiv - Biophysics 2021Quote: ... of purified CtenDNAV-II virons (10 mg ml-1) was deposited onto freshly glow-discharged holey carbon-coated copper grids (Quantifoil R 2/2, 300 mesh, copper) followed by 2 s of blotting in 100% relative humidity for plunge-freezing (Vitrobot Mark IV ...
-
bioRxiv - Biophysics 2020Quote: Quantifoil grids (200 mesh Au R2/2 and Au Finder; Quantifoil Micro Tools GmbH ...
-
bioRxiv - Cell Biology 2021Quote: R 2/1 Holey Carbon Au 200 mesh EM grids (Quantifoil) were coated with approximately 20 nm of carbon in a MED 020 carbon coater (BAL-TEC ...
-
bioRxiv - Biochemistry 2022Quote: ... R3/3 copper grids with a 2 nm carbon coating (Quantifoil) using a Vitrobot mark IV (FEI ...
-
bioRxiv - Microbiology 2022Quote: ... EM grids (R2/2, Cu 200 mesh; Quantifoil Micro Tools GmbH) were glow-discharged for 45 sec at 25 mA by PELCO easiGlow discharger ...
-
bioRxiv - Molecular Biology 2021Quote: ... UltrAuFoil (Russo and Passmore, 2014) R2/2 200 mesh grids (Quantifoil) were glow discharged for 15 s at 30 mA in a Quorum SC7620 ...
-
bioRxiv - Molecular Biology 2022Quote: ... The plus carbon sample (Quantifoil Cu300 R2/1 + 2 nm C) was blotted for 2 s with blot force +3 after a 30 s wait time after sample application and immediately plunge frozen in liquid ethane ...
-
bioRxiv - Microbiology 2022Quote: ... Gold quantifoil R2/2 200 mesh grids (Quantifoil Micro Tools GmbH) were sterilised with 70% ethanol and placed in glass bottomed MatTek dishes (MatTek Corporation ...
-
bioRxiv - Biochemistry 2023Quote: ... Holey carbon R2/2 300 mesh grids (Quantifoil Micro Tools GmbH) were glow-discharged for 90 sec at 25 mA using a PELCO easiGlow glow discharge cleaning system ...
-
bioRxiv - Cell Biology 2023Quote: ... 3 μl of this sample were placed on a glow-discharged EM grid (lacey carbon films on Cu 200 mesh, Quantifoil Micro Tools), blotted from the back side for 3 s ...
-
bioRxiv - Cell Biology 2020Quote: Either 200 mesh gold holey carbon grids (R2/2; Quantifoil Micro Tools) or 200 mesh gold grids (Science Services ...
-
bioRxiv - Cell Biology 2020Quote: Gold EM grids with Quantifoil R 2/1 holey carbon film (Quantifoil Micro Tools GmbH ...
-
bioRxiv - Microbiology 2022Quote: ... cells were seeded on R2/2 gold UltrAufoil grids (200 mesh, Quantifoil Micro Tools GmbH ...
-
bioRxiv - Molecular Biology 2020Quote: ... gold 300 mesh Quantifoil R2/2 holey carbon grids (Quantifoil Micro Tools) were glow discharged using an Edwards Sputter Coater 305B ...