Labshake search
Citations for Quantifoil Micro Tools :
101 - 150 of 619 citations for 7 Amino 4 methyl 1 8 naphthyridin 2 ol since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Microbiology 2024Quote: ... Continuous carbon grids (Quantifoil R 2/2 on Cu 300 mesh grids + 2 nm Carbon, Quantifoil Micro Tools C2-C16nCu30-01) were glow-discharged for 5 sec in an easiGlow Glow Discharge Cleaning System (Ted Pella Inc.) ...
-
bioRxiv - Molecular Biology 2022Quote: ... Glow-discharged carbon coated gold mesh grids (QF 2/2 AU 200, Quantifoil) were placed on the edge of the glass microscopy slides ...
-
bioRxiv - Bioengineering 2022Quote: ... holey carbon grids (Ultrafoil 25 nM Au R 2/2 200 mesh; Quantifoil) were glow-discharged for 10 s using the Solarus plasma cleaner (Gatan) ...
-
bioRxiv - Biochemistry 2023Quote: ... Cryo-EM grids (carbon-coated Quantifoil R 2/2 cupper grids, 300 mesh) were plunge-frozen using a Vitrobot IV (Thermo Fisher Scientific ...
-
bioRxiv - Biochemistry 2023Quote: ... the same proteins were applied to holey grids with a 2 nm carbon film (Quantifoil Cu 2/2 200 mesh from EMS). Samples were frozen after a total of 145 min on the grids without carbon film and 150 min on the grids with carbon film ...
-
bioRxiv - Biophysics 2020Quote: Three microliters of purified HCoV-NL63 virions (4.5 mg/mL) were first applied to 300-mesh R2/1 + 2 nm C-film grids (Quantifoil) that had been glow-discharged for 15s PELCO easiGlow (TED PELLA ...
-
bioRxiv - Microbiology 2021Quote: ... and 5 µl of the mixture was placed onto freshly glow discharged holey carbon grids (R 2/1, Quantifoil) for 1 min ...
-
bioRxiv - Molecular Biology 2019Quote: ... 0.05% Tween-20 was pre-applied on a glow-discharged holey carbon grid (Quantifoil, QF 2/1, 300 mesh) covered with a 2 nm carbon layer ...
-
bioRxiv - Biophysics 2023Quote: Gold 200 mesh carbon or SiO2 R 2/1 grids or R 1.2/20 grids (Quantifoil Micro Tools GmbH) were coated with ∼8 nm of carbon using a Leica ACE600 (Leica Microsystems GmbH) ...
-
bioRxiv - Biophysics 2024Quote: ... Aliquots of 1.25 – 1.5 ul RyR1-nanodisc were applied onto each side of glow-discharged C-Flat - 2/1 - 3Au holey-carbon (Protochips, NC) or UltraAufoil -1.2/1.3 holey-gold (Quantifoil, Germany) with 300 TEM mesh ...
-
bioRxiv - Cell Biology 2024Quote: ... the sample was gently resuspended and 4 µl was transferred to a glow-discharged holey carbon R2/1 copper grid (Quantifoil Micro Tools) suspended in the chamber of a Vitrobot (Thermo Fisher Scientific) ...
-
bioRxiv - Biochemistry 2021Quote: ... the samples (3.5 μl) were applied onto UltraAuFoil R 2/2 gold grids (Quantifoil Micro Tools GMBH ...
-
bioRxiv - Cell Biology 2021Quote: Gold grids (Quantifoil, R2/2) were glow-discharged and incubated on top of 40 μL droplets of fibronectin (50 μg/mL ...
-
bioRxiv - Cell Biology 2020Quote: ... or holey SiO2 R1/4 TEM grids (Quantifoil) to allow for more robust correlation and cells were plunge frozen on a Vitrobot Mark IV (FEI ...
-
bioRxiv - Cell Biology 2022Quote: ... Grids (200 Mesh Cu SiO2 R1/4, Quantifoil) were plasma cleaned for 30 s before plunging ...
-
bioRxiv - Biochemistry 2020Quote: ... 3 μL of the concentrated RdRp-RNA complex were mixed with 0.5 μl of octyl ß-D-glucopyranoside (0.003% final concentration) and applied to freshly glow discharged R 2/1 holey carbon grids (Quantifoil). The grids were blotted for 5 seconds using a Vitrobot MarkIV (Thermo Fischer Scientific ...
-
bioRxiv - Biochemistry 2021Quote: ... 3 µL of the concentrated RdRp-RNA complex were mixed with 0.5 µl of octyl ß-D-glucopyranoside (0.003% final concentration) and applied to freshly glow discharged R 2/1 holey carbon grids (Quantifoil). The grids were blotted for 7 seconds with blot force 5 using a Vitrobot MarkIV (Thermo Fischer Scientific ...
-
bioRxiv - Biophysics 2020Quote: ... 3 μL of the concentrated RdRp-RNA complex were mixed with 0.5 μl of octyl ß-D-glucopyranoside (0.003% final concentration) and applied to freshly glow discharged R 2/1 holey carbon grids (Quantifoil). Prior to flash freezing in liquid ethane ...
-
bioRxiv - Molecular Biology 2020Quote: ... a 2.2-µL aliquot of this sample was applied to a plasma cleaned holey carbon grid (R2/1, 200 mesh; Quantifoil) or Graphene Oxide-Lacey Carbon grid (300 mesh ...
-
bioRxiv - Biophysics 2020Quote: ... Mycoplasma pneumoniae strain M129(ATCC 29342)cells were grown on 200 mesh gold grids coated with a holey carbon support (R 2/1, Quantifoil). Cells were cultivated at 37 °C in modified Hayflick medium ...
-
bioRxiv - Microbiology 2022Quote: ... and 4 µl of the mixture was applied to a glow-discharged holey-carbon copper EM grid (R2/1 or R2/2, Quantifoil). The grid was automatically blotted from the backside for 4-6 s in a Mark IV Vitrobot by using a Teflon sheet on the front pad ...
-
bioRxiv - Microbiology 2022Quote: ... mixed with 10 nm protein A-coated colloidal gold (Aurion) and applied onto a glow-discharged EM grid (200 mesh, R 2/1, Quantifoil) prior to plunge-freezing with a Leica EM GP2 automatic plunge-freezer.
-
bioRxiv - Cell Biology 2023Quote: Cells were blotted on EM grids (R 2/1 holey carbon 200 films on Cu 200 mesh, Quantifoil Micro Tools). The grids were first glow-discharged and 4 µl of trypanosome wild-type culture (2-4 · 107 cells/ml ...
-
bioRxiv - Microbiology 2023Quote: ... and 4 µl of the mixture was applied to a glow-discharged holey-carbon copper EM grid (R2/1 or R2/2, Quantifoil). The grid was automatically backside blotted for 4-6s in a Mark IV Vitrobot (Thermo Fischer Scientific ...
-
bioRxiv - Cell Biology 2023Quote: ... An aliquot of 3 ul cell suspension was applied to the glow-discharged holey carbon-coated copper (R 2/1, 200 mesh) (Quantifoil) and blotted for 9 seconds by Leica GP2 (Leica Microsystems) ...
-
bioRxiv - Biochemistry 2024Quote: ... using 3 µL of the samples applied to previously glow discharged R 2/1 Holey Carbon Cu 200 mesh EM grids (Quantifoil). Samples were 10 µM FtsZ with or without ZapD or mZapD at different concentrations specified in each case (0 – 60 µM) ...
-
bioRxiv - Molecular Biology 2023Quote: ... a 4 µl sample of purified complex was applied to glow-discharged R2/1 300 mesh holey carbon copper grids (Quantifoil Micro Tools GmbH), using a conc ...
-
bioRxiv - Cell Biology 2023Quote: 4 ul of Nannochloropsis suspensions (4 x 107 cells mL−1) were pipetted onto a 300 mesh gold Quantifoil grid with 2um holes (Quantifoil Micro Tools, GmbH) and manually blotted from the opposite side in a Vitrobot Mark IV (ThermoFisher Scientific ...
-
bioRxiv - Neuroscience 2023Quote: ... applied to glow-discharged 2/2 μm holey carbon-coated 200-mesh gold grids (Quantifoil) and plunge-frozen in liquid ethane using a Vitrobot Mark IV (Thermo Fisher) ...
-
bioRxiv - Biochemistry 2022Quote: 4 µl aliquots of purified samples at A280 = 1 were applied onto glow-discharged holey carbon-coated grids (Quantifoil 300 mesh, Au R1.2/1.3), then adsorbed for 10 s ...
-
bioRxiv - Biochemistry 2020Quote: A droplet of 3 μl of purified GluD2 Δ870 at a concentration of ~0.8 mg/ml was applied onto a glow discharged 1.2/1.3 300 mesh ultra foil gold grid (Quantifoil). It was blotted for 3 seconds at a blot force of 0 using the FEI Vitrobot Mark IV at 14°C and 95 % humidity ...
-
bioRxiv - Biophysics 2020Quote: ... 2.8 μl of sample was pipetted onto glow-discharged R1.2/1.3 200 mesh Au holey carbon grids (Quantifoil) and then plunge-frozen in a liquid ethane/propane mixture with a Vitrobot Mark IV (Thermo Fisher Scientific) ...
-
bioRxiv - Immunology 2023Quote: ... 3 μL of the purified complex (8 mg/ml) was deposited onto a glow-discharged holey grid (Quantifoil Au 300 mesh R1.2/1.3 ...
-
bioRxiv - Cell Biology 2021Quote: 3 mm gold EM grids with a holey carbon film (R 2/2, 200 mesh; Quantifoil Cat no ...
-
bioRxiv - Biochemistry 2020Quote: ... 200 mesh Cu grids with Quantifoil R 2/2 holey carbon films (Quantifoil Micro Tools GmbH) were used ...
-
bioRxiv - Biochemistry 2019Quote: ... the same sample was applied to a 200 mesh 2/2 UltrAuFoil Holey Gold grid (Quantifoil) that was glow-discharged for 60 seconds at 20 mA ...
-
bioRxiv - Cell Biology 2023Quote: ... the cells were seeded on Quantifoil R 2/2 200 gold mesh grids (Quantifoil, Großlöbichau, Germany) coated with 100 mg/mL poly-L-lysine and 50 µg/mL collagen I ...
-
bioRxiv - Biophysics 2022Quote: ... R2/2 Cu 300 grids (Quantifoil) were glow-discharged for 1 min at 0.19 mbar and 20 mA in a PELCO easiGlow device ...
-
bioRxiv - Microbiology 2020Quote: ... or Quantifoil R2/2 (Quantifoil, Germany). The samples were cryo-fixed by plunge freezing at −180°C in liquid ethane using a Leica EMGP (Leica ...
-
bioRxiv - Microbiology 2022Quote: ... we used R2/2 grids (Quantifoil) coated with a thin layer of 0.2 mg/ml graphene oxide ...
-
bioRxiv - Microbiology 2022Quote: ... Quantifoil (R2/2, Quantifoil Micro Tools) Au-EM finder grids ...
-
bioRxiv - Biochemistry 2023Quote: Quantifoil Cu200 R2/2 grids (Quantifoil) were pre-clipped and marked along the clip edge to determine the orientation in the future ...
-
Cryo-electron tomography of eel sperm flagella reveals a molecular “minimum system” for motile ciliabioRxiv - Cell Biology 2023Quote: ... holey carbon grids (Quantifoil R2/2) were glow discharged for 30 seconds in a Pelco EasyGlow glow discharge unit ...
-
bioRxiv - Biochemistry 2021Quote: ... applied to 300-mesh carbon coated (2nm thickness) holey carbon Quantifoil 2/2 grids (Quantifoil Micro Tools) and flash-frozen as described in (Khatter et al. ...
-
bioRxiv - Biochemistry 2019Quote: ... The sample (3.5 µL) was applied to glow discharged UltrAUfoil 2/2 200 mesh gold grids (Quantifoil) and plunge-frozen using a vitrobot Mark IV (Thermo Fischer) ...
-
bioRxiv - Microbiology 2023Quote: ... the sample was loaded onto Quantifoil carbon coated grids (R 2/2; Quantifoil Micro Tools, Jena, Germany) and cryo-fixed by plunge freezing with a Leica GP (Leica Microsystems ...
-
bioRxiv - Biophysics 2023Quote: EM grids (UltrAuFoil R2/2 Au 200 mesh Q250AR2A and Quantifoil R2/2 Au 200 mesh Q2100AR2) were micropatterned using the Alveole PRIMO micropatterning system20–22 ...
-
bioRxiv - Synthetic Biology 2021Quote: ... 25 mM Tris at pH 8.0 to a concentration of 2 mg/mL to a glow-discharged (1 min at 5 mA) holey carbon grid (Quantifoil Q225-CR1.3). This was followed by plunge-freezing in liquid ethane using an FEI Vitribot Mark IV (100% humidity ...
-
bioRxiv - Cell Biology 2020Quote: ... 3.5 µL of gel filtration column eluate (∼0.5 mg/ml) was applied to a holey carbon support (Quantifoil 2/1-4Cu-50) at ∼90% relative humidity ...
-
bioRxiv - Cell Biology 2021Quote: ... Glow-discharged holey Quantifoil grids with an additional layer of continuous carbon (R2/1 + 2 nm C, Cu 200 mesh grid, Quantifoil Micro Tools) were used ...