Labshake search
Citations for Quantifoil Micro Tools :
101 - 150 of 576 citations for 6H dibenz C E 1 2 oxaphosphorin 6 oxide since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biochemistry 2021Quote: ... 3 µL of the concentrated RdRp-RNA complex were mixed with 0.5 µl of octyl ß-D-glucopyranoside (0.003% final concentration) and applied to freshly glow discharged R 2/1 holey carbon grids (Quantifoil). The grids were blotted for 7 seconds with blot force 5 using a Vitrobot MarkIV (Thermo Fischer Scientific ...
-
bioRxiv - Biophysics 2020Quote: ... 3 μL of the concentrated RdRp-RNA complex were mixed with 0.5 μl of octyl ß-D-glucopyranoside (0.003% final concentration) and applied to freshly glow discharged R 2/1 holey carbon grids (Quantifoil). Prior to flash freezing in liquid ethane ...
-
bioRxiv - Molecular Biology 2020Quote: ... a 2.2-µL aliquot of this sample was applied to a plasma cleaned holey carbon grid (R2/1, 200 mesh; Quantifoil) or Graphene Oxide-Lacey Carbon grid (300 mesh ...
-
bioRxiv - Biophysics 2020Quote: ... Mycoplasma pneumoniae strain M129(ATCC 29342)cells were grown on 200 mesh gold grids coated with a holey carbon support (R 2/1, Quantifoil). Cells were cultivated at 37 °C in modified Hayflick medium ...
-
bioRxiv - Microbiology 2022Quote: ... and 4 µl of the mixture was applied to a glow-discharged holey-carbon copper EM grid (R2/1 or R2/2, Quantifoil). The grid was automatically blotted from the backside for 4-6 s in a Mark IV Vitrobot by using a Teflon sheet on the front pad ...
-
bioRxiv - Microbiology 2022Quote: ... mixed with 10 nm protein A-coated colloidal gold (Aurion) and applied onto a glow-discharged EM grid (200 mesh, R 2/1, Quantifoil) prior to plunge-freezing with a Leica EM GP2 automatic plunge-freezer.
-
bioRxiv - Cell Biology 2023Quote: Cells were blotted on EM grids (R 2/1 holey carbon 200 films on Cu 200 mesh, Quantifoil Micro Tools). The grids were first glow-discharged and 4 µl of trypanosome wild-type culture (2-4 · 107 cells/ml ...
-
bioRxiv - Microbiology 2023Quote: ... and 4 µl of the mixture was applied to a glow-discharged holey-carbon copper EM grid (R2/1 or R2/2, Quantifoil). The grid was automatically backside blotted for 4-6s in a Mark IV Vitrobot (Thermo Fischer Scientific ...
-
bioRxiv - Cell Biology 2023Quote: ... An aliquot of 3 ul cell suspension was applied to the glow-discharged holey carbon-coated copper (R 2/1, 200 mesh) (Quantifoil) and blotted for 9 seconds by Leica GP2 (Leica Microsystems) ...
-
bioRxiv - Biophysics 2023Quote: ... HeLa cells were trypsinized and seeded at a density of 0.5 – 0.7 X 105 cells/mL on carbon-coated gold Quantifoil grid (200 mesh, R 2/1, holey SiO2 film; Quantifoil Micro Tools GmbH ...
-
bioRxiv - Biochemistry 2024Quote: ... using 3 µL of the samples applied to previously glow discharged R 2/1 Holey Carbon Cu 200 mesh EM grids (Quantifoil). Samples were 10 µM FtsZ with or without ZapD or mZapD at different concentrations specified in each case (0 – 60 µM) ...
-
bioRxiv - Neuroscience 2023Quote: ... applied to glow-discharged 2/2 μm holey carbon-coated 200-mesh gold grids (Quantifoil) and plunge-frozen in liquid ethane using a Vitrobot Mark IV (Thermo Fisher) ...
-
bioRxiv - Cell Biology 2021Quote: 3 mm gold EM grids with a holey carbon film (R 2/2, 200 mesh; Quantifoil Cat no ...
-
bioRxiv - Biochemistry 2020Quote: ... 200 mesh Cu grids with Quantifoil R 2/2 holey carbon films (Quantifoil Micro Tools GmbH) were used ...
-
bioRxiv - Biochemistry 2019Quote: ... the same sample was applied to a 200 mesh 2/2 UltrAuFoil Holey Gold grid (Quantifoil) that was glow-discharged for 60 seconds at 20 mA ...
-
bioRxiv - Cell Biology 2023Quote: ... the cells were seeded on Quantifoil R 2/2 200 gold mesh grids (Quantifoil, Großlöbichau, Germany) coated with 100 mg/mL poly-L-lysine and 50 µg/mL collagen I ...
-
bioRxiv - Biophysics 2022Quote: ... R2/2 Cu 300 grids (Quantifoil) were glow-discharged for 1 min at 0.19 mbar and 20 mA in a PELCO easiGlow device ...
-
bioRxiv - Microbiology 2020Quote: ... or Quantifoil R2/2 (Quantifoil, Germany). The samples were cryo-fixed by plunge freezing at −180°C in liquid ethane using a Leica EMGP (Leica ...
-
bioRxiv - Microbiology 2022Quote: ... we used R2/2 grids (Quantifoil) coated with a thin layer of 0.2 mg/ml graphene oxide ...
-
bioRxiv - Microbiology 2022Quote: ... Quantifoil (R2/2, Quantifoil Micro Tools) Au-EM finder grids ...
-
bioRxiv - Biochemistry 2023Quote: Quantifoil Cu200 R2/2 grids (Quantifoil) were pre-clipped and marked along the clip edge to determine the orientation in the future ...
-
Cryo-electron tomography of eel sperm flagella reveals a molecular “minimum system” for motile ciliabioRxiv - Cell Biology 2023Quote: ... holey carbon grids (Quantifoil R2/2) were glow discharged for 30 seconds in a Pelco EasyGlow glow discharge unit ...
-
bioRxiv - Biochemistry 2021Quote: ... applied to 300-mesh carbon coated (2nm thickness) holey carbon Quantifoil 2/2 grids (Quantifoil Micro Tools) and flash-frozen as described in (Khatter et al. ...
-
bioRxiv - Biochemistry 2019Quote: ... The sample (3.5 µL) was applied to glow discharged UltrAUfoil 2/2 200 mesh gold grids (Quantifoil) and plunge-frozen using a vitrobot Mark IV (Thermo Fischer) ...
-
bioRxiv - Microbiology 2023Quote: ... the sample was loaded onto Quantifoil carbon coated grids (R 2/2; Quantifoil Micro Tools, Jena, Germany) and cryo-fixed by plunge freezing with a Leica GP (Leica Microsystems ...
-
bioRxiv - Biophysics 2023Quote: EM grids (UltrAuFoil R2/2 Au 200 mesh Q250AR2A and Quantifoil R2/2 Au 200 mesh Q2100AR2) were micropatterned using the Alveole PRIMO micropatterning system20–22 ...
-
bioRxiv - Synthetic Biology 2021Quote: ... 25 mM Tris at pH 8.0 to a concentration of 2 mg/mL to a glow-discharged (1 min at 5 mA) holey carbon grid (Quantifoil Q225-CR1.3). This was followed by plunge-freezing in liquid ethane using an FEI Vitribot Mark IV (100% humidity ...
-
bioRxiv - Cell Biology 2020Quote: ... 3.5 µL of gel filtration column eluate (∼0.5 mg/ml) was applied to a holey carbon support (Quantifoil 2/1-4Cu-50) at ∼90% relative humidity ...
-
bioRxiv - Biophysics 2020Quote: Purified GABAAR was incubated with ~1 μM Megabody-2524 and 3.5 μl sample was applied to glow discharged 300 mesh 1.2/1.3 and 2/2 UltraAuFoil gold grids (Quantifoil) for 30 s then blotted for 5.5 s prior to plunge-freezing with liquid ethane cooled by liquid nitrogen ...
-
bioRxiv - Bioengineering 2022Quote: ... Holey carbon Quantifoil grids (2 µm diameter with an interspace of 2 µm, Quantifoil Micro Tools GmbH, Germany) were prepared by glow discharge (easyGlow® System ...
-
bioRxiv - Microbiology 2022Quote: ... using R2/2 200 mesh grids (Quantifoil) and imaged using a Talos 120 kV cryo-transmission electron microscope.
-
bioRxiv - Biochemistry 2023Quote: UltrAuFoil R2/2 Au200 mesh grids (Quantifoil) were glow discharged for 1 min on both sides at 25 mA using a Pelco easiGlow unit (Ted Pella ...
-
bioRxiv - Biochemistry 2023Quote: UltrAuFoil R2/2 Au300 mesh grids (Quantifoil) were glow discharged for 30 seconds on each side at 25 mA using a Pelco easiGlow unit (Ted Pella ...
-
bioRxiv - Microbiology 2023Quote: R2/2 Cu 200 mesh grids (Quantifoil) were glow-discharged for 40 s at 2.7 mA ...
-
bioRxiv - Microbiology 2020Quote: ... 3.5 μl of cell suspension from 80-100 μl of final volume were applied on glow discharged 200-mesh EM copper grids coated with R 2/1 holey SiO2 films (Quantifoil Micro Tool GmbH) and plunge frozen in liquid ethane at ~−184°C using a Leica EM GP grid plunger ...
-
bioRxiv - Biophysics 2020Quote: ... 3.5ul of cell suspension were applied on 200-mesh copper grids coated with R 2/1 holey carbon or SiO2 films (Quantifoil Micro Tools GmbH) and plunge frozen in liquid ethane at ~-186°C using a Leica EM GP grid plunger ...
-
bioRxiv - Immunology 2022Quote: ... detergent at a final concentration of 0.005 mM was added to each sample and 3 µl of that solution was immediately loaded onto plasma-cleaned QuantiFoil R 2/1 (400-mesh; Quantifoil Micro Tools GmbH) and UltrAuFoil R 1.2/1.3 grids (300-mesh ...
-
bioRxiv - Immunology 2020Quote: ... and 3 µl was immediately loaded onto plasma cleaned Quantifoil R 2/1 holey carbon copper gri (Cu, 400-mesh, Quantifoil Micro Tools GmbH). Blotted grids were plunge-frozen into nitrogen-cooled liquid ethane.
-
bioRxiv - Microbiology 2022Quote: ... 5 µL of the mixture was placed onto freshly glow discharged holey carbon grids (Quantifoil™ R 2/1 on 200 copper mesh) for 1 minute ...
-
bioRxiv - Molecular Biology 2022Quote: ... 2–3 μL of sample solution was applied to a holey carbon grid (Quantifoil R2/1, Mo 300 mesh; Quantifoil Micro Tools GmbH) covered with a thin amorphous carbon film at 4 °C with 100% humidity ...
-
bioRxiv - Microbiology 2023Quote: ... Both TBEV strain Neudoerfl and Hypr samples were vitrified in liquid ethane on holey carbon coated copper grids (Quantifoil 2/1, mesh 300, Quantifoil Micro Tools GmbH) using Vitrobot Mark IV (Thermo Fisher) ...
-
bioRxiv - Biochemistry 2023Quote: ... 3µL of sample were frozen in liquid ethane on 2/1 Quantifoil Multi A holey carbon supported grids (Quantifoil, Multi A, 400 mesh) using Vitrobot Mark IV (FEI Company) ...
-
bioRxiv - Biophysics 2023Quote: Three microliters of the purified GLV-HP or GLV-CAT sample was placed on a glow-discharged holey carbon grid (Quantifoil R2/2 or R2/1, Cu 300 mesh; Quantifoil Micro Tools GmbH) for 3 s blotting time at 4°C ...
-
bioRxiv - Bioengineering 2023Quote: ... a 200-mesh copper grid covered with a Quantifoil R 2/2 holey carbon film (Quantifoil Micro Tools GmbH) was surface plasma treated for 40 seconds using a Cressington 208 carbon coater ...
-
bioRxiv - Cell Biology 2023Quote: ... three microliters of EV sample were directly placed onto a glow–discharged 2/2 copper grid (Quantifoil, Jena, Germany). The excess sample was removed with 595 filter paper (Schleicher & Schuell ...
-
bioRxiv - Cell Biology 2023Quote: ... Two μl of the diluted complex were applied to freshly glow-discharged R 2/2 holey carbon grids (Quantifoil), which were blotted with a force of 6 for 5 seconds and immediately vitrified by plunge-freezing in liquid ethane using a Vitrobot Mark IV (ThermoFisher ...
-
bioRxiv - Biophysics 2022Quote: ... an aliquot of 3 μL of sample was applied onto a glow-discharged holey carbon-coated copper grid (300 mesh, QUANTIFOIL® R 2/1) or holey gold grid (300 mesh ...
-
bioRxiv - Molecular Biology 2019Quote: ... 2.4 μl of 0.12 mg/ml of the protein preparation were applied to glow-discharged holey carbon grids (Quantifoil, QF 2/1, 300 mesh) covered with a 2 nm carbon layer ...
-
bioRxiv - Molecular Biology 2019Quote: ... 2.8 µl of 0.10 mg/ml of the protein preparation were applied to glow-discharged holey carbon grids (Quantifoil, QF 2/1, 300 mesh) covered with a 2 nm carbon layer ...
-
bioRxiv - Biophysics 2020Quote: ... This sample was used for EM dataset 6: the purified sample was applied to Cu 300 R1.2/1.3 holey carbon grids (Quantifoil) coated with a ∼7 nm homemade carbon film ...