Labshake search
Citations for Quantifoil Micro Tools :
101 - 150 of 470 citations for 2 4 Dimethyl 4' 4 methylpiperazinomethyl benzophenone since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biochemistry 2022Quote: ... Spike trimer - Fab complexes (4 μl) were applied to the pre-glow-discharged holey carbon grids (Quantifoil grid, Cu 300 mesh, R1.2/1.3). The grids were then blotted for 2 seconds with filter paper in 100% relative humidity and 8 °C and plunged into the liquid ethane to freeze samples using FEI Vitrobot system (FEI).
-
bioRxiv - Molecular Biology 2022Quote: ... An aliquot of 4 μL protein sample of Spike protein was applied onto a glow-discharged 300 mesh grid (Quantifoil Au R1.2/1.3) and GraFuture™-RGO grid which was supported with a thin layer of RGO (reduced graphene oxide) ...
-
bioRxiv - Molecular Biology 2023Quote: ... a 4 µl sample of purified complex was applied to glow-discharged R2/1 300 mesh holey carbon copper grids (Quantifoil Micro Tools GmbH), using a conc ...
-
bioRxiv - Cell Biology 2023Quote: 4 ul of Nannochloropsis suspensions (4 x 107 cells mL−1) were pipetted onto a 300 mesh gold Quantifoil grid with 2um holes (Quantifoil Micro Tools, GmbH) and manually blotted from the opposite side in a Vitrobot Mark IV (ThermoFisher Scientific ...
-
bioRxiv - Biochemistry 2023Quote: 4 μL of Fcα–J–FcRL4 (0.3 mg/mL) were applied to glow-discharged holy-carbon gold grids (Quantifoil, R1.2/1.3, 300 mesh) or Ni-Ti grids (CryoMatrix ...
-
bioRxiv - Molecular Biology 2021Quote: ... 4 μl of protein sample (about 1.5 mg/ml) was applied onto a glow-discharged holey carbon grid (Quantifoil Au, R1.2/1.3, 300 mesh). At a temperature of 4°C and under a humidity of 100% ...
-
bioRxiv - Biochemistry 2022Quote: 4 µl aliquots of purified samples at A280 = 1 were applied onto glow-discharged holey carbon-coated grids (Quantifoil 300 mesh, Au R1.2/1.3), then adsorbed for 10 s ...
-
bioRxiv - Biophysics 2020Quote: ... An aliquot of 4 μl pY39 α-syn fibril solution was applied to a glow-discharged carbon electron microscope grid (Quantifoil R1.2/1.3, 300 mesh). After 10 s of incubation ...
-
bioRxiv - Molecular Biology 2021Quote: The purified GIP1-42–GIPR–Gs–Nb35 complex at a concentration of 6-7 mg/mL was mixed with 100 μM GIP1-42 at 4 C and applied to glow-discharged holey carbon grids (Quantifoil R1.2/1.3, Au 300 mesh) that were subsequently vitrified by plunging into liquid ethane using a Vitrobot Mark IV (ThermoFisher Scientific) ...
-
bioRxiv - Molecular Biology 2021Quote: The purified tirzepatide–GIPR–Gs–Nb35 complex at a concentration of 18-20 mg/mL was mixed with 100 μM tirzepatide at 4°C and applied to glow-discharged holey carbon grids (Quantifoil R1.2/1.3, Au 300 mesh) that were subsequently vitrified by plunging into liquid ethane using a Vitrobot Mark IV (ThermoFisher Scientific) ...
-
bioRxiv - Molecular Biology 2021Quote: The purified non-acylated tirzepatide–GIPR–mini-Gs–Nb35 complex at a concentration of 14-16 mg/mL was mixed with 100 μM non-acylated tirzepatide at 4°C and applied to glow-discharged holey carbon grids (Quantifoil R1.2/1.3, Au 300 mesh) that were subsequently vitrified by plunging into liquid ethane using a Vitrobot Mark IV (ThermoFisher Scientific) ...
-
bioRxiv - Molecular Biology 2021Quote: The purified peptide 20–GIPR–Gs–Nb35 complex at a concentration of 5-6 mg/mL was mixed with 100 μM peptide 20 at 4°C and applied to glow-discharged holey carbon grids (Quantifoil R1.2/1.3, Au 300 mesh) that were subsequently vitrified by plunging into liquid ethane using a Vitrobot Mark IV (ThermoFisher Scientific) ...
-
bioRxiv - Molecular Biology 2021Quote: The purified peptide 20–GCGR–Gs–Nb35 complex at a concentration of 12-14 mg/mL was mixed with 100 μM peptide 20 at 4°C and applied to glow-discharged holey carbon grids (Quantifoil R1.2/1.3, Au 300 mesh) that were subsequently vitrified by plunging into liquid ethane using a Vitrobot Mark IV (ThermoFisher Scientific) ...
-
bioRxiv - Biochemistry 2023Quote: ... Four microliters of purified Cx36 proteins (4-6 mg/ml) were applied onto a negatively glow-discharged holey carbon grid (Quantifoil R1.2/1.3 Cu 300 mesh). For samples involving Cx36-WT ...
-
bioRxiv - Biophysics 2020Quote: ... The WT and Y222F MTs were applied to lacey carbon grids (Agar Scientific AGS166-4 400 mesh copper grids) and holey carbon grids (Quantifoil R1.2/1.3 300 mesh copper grids) immediately after application of glow discharge to the grids ...
-
bioRxiv - Biophysics 2023Quote: ... Micropatterns covered an area of 8 × 8 squares around the center of the cryo-TEM grids (Quantifoil R1/4 or R1/20, Au 200 mesh, SiO2 film) as previously described31 ...
-
bioRxiv - Molecular Biology 2020Quote: ... plain grids (Quantifoil 2/2) were transferred to the microscope ...
-
bioRxiv - Biochemistry 2024Quote: ... carbon-coated (Quantifoil R 2/2) 200-mesh copper grids (Electron Microscopy Sciences ...
-
bioRxiv - Biochemistry 2022Quote: ... holey copper grids (QUANTIFOIL R 2/2). 3.5-μl samples were adsorbed for 1 min at +20 °C ...
-
bioRxiv - Microbiology 2020Quote: Holey carbon-coated (R 2/2; Quantifoil) Au-G200F1 grids were analyzed in cryo-conditions by MISTRAL microscope at ALBA synchrotron ...
-
bioRxiv - Biochemistry 2020Quote: ... 3 µl of sample were applied to glow-discharged Quantifoil Au 2/2 holey carbon 200 mesh grids or Ultrafoil Au 2/2 holey gold 200 mesh grids (Quantifoil), and flash frozen in liquid ethane using an FEI Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Molecular Biology 2023Quote: A QuantiFoil 300-mesh R 2/2 grid with 2 nm continuous carbon (QuantiFoil Micro Tools GmbH ...
-
bioRxiv - Biochemistry 2020Quote: UltrAUfoil 2/2 300 mesh gold grids (Quantifoil) were used for open hole data collection (Dataset 1) ...
-
bioRxiv - Biophysics 2020Quote: ... or QUANTIFOIL R 2/2 holey carbon grids (Quantifoil Micro Tools GmbH ...
-
bioRxiv - Biophysics 2022Quote: ... holey carbon grid coated with 2 nm ultrathin carbon film (Quantifoil 300-mesh, R 2/2). After waiting for 60 s ...
-
bioRxiv - Biochemistry 2021Quote: Holey grids (gold, 200 mesh, r 2/2 by Quantifoil) were glow-discharged for 30 seconds using a Pelco glow discharge system ...
-
bioRxiv - Biophysics 2024Quote: Holey carbon grids (Quantifoil Au R 2/2, 200 mesh) were glow-discharged with easiGlow at 20 mA for 45 s ...
-
bioRxiv - Biophysics 2023Quote: ... split onto Poly-D-Lysine coated R 2/2 grids (QUANTIFOIL 100 Holey Carbon Films ...
-
bioRxiv - Immunology 2024Quote: ... The sample was prepared on Quantifoil Cu 300 2/2 (Quantifoil) grids and was frozen in liquid ethane using the Vitroblot Mark IV (Thermo Fisher ...
-
bioRxiv - Biophysics 2023Quote: ... glow discharged QUANTIFOIL® copper R 2/2 grid with a 2 nm thin extra carbon layer (QUANTIFOIL, GMBH) was used ...
-
bioRxiv - Biochemistry 2021Quote: ... Quantifoil Cu 300 mesh (R 2/2 geometry; Quantifoil Micro Tools GMBH) covered with a thin layer of 3 nm carbon were used for the for the GTPBP5KO sample ...
-
bioRxiv - Biochemistry 2022Quote: R2/2 grids (Quantifoil) were covered with a thin layer of continuous carbon (estimated to be 50 Å thick ...
-
bioRxiv - Microbiology 2024Quote: ... Continuous carbon grids (Quantifoil R 2/2 on Cu 300 mesh grids + 2 nm Carbon, Quantifoil Micro Tools C2-C16nCu30-01) were glow-discharged for 5 sec in an easiGlow Glow Discharge Cleaning System (Ted Pella Inc.) ...
-
bioRxiv - Biochemistry 2022Quote: ... Continuous carbon grids (Quantifoil R 2/2 on Cu 300 mesh grids + 2 nm Carbon, Quantifoil Micro Tools C2-C16nCu30-01) were glow-discharged for 5 sec in an easiGlow Glow Discharge Cleaning System (Ted Pella Inc.) ...
-
bioRxiv - Molecular Biology 2022Quote: ... Glow-discharged carbon coated gold mesh grids (QF 2/2 AU 200, Quantifoil) were placed on the edge of the glass microscopy slides ...
-
bioRxiv - Neuroscience 2020Quote: ... covered with either 2 nm amorphous carbon (Quantifoil, R2/1+2 nm C) or graphene were used for sample preparation ...
-
bioRxiv - Bioengineering 2022Quote: ... holey carbon grids (Ultrafoil 25 nM Au R 2/2 200 mesh; Quantifoil) were glow-discharged for 10 s using the Solarus plasma cleaner (Gatan) ...
-
bioRxiv - Biochemistry 2023Quote: ... Cryo-EM grids (carbon-coated Quantifoil R 2/2 cupper grids, 300 mesh) were plunge-frozen using a Vitrobot IV (Thermo Fisher Scientific ...
-
bioRxiv - Biochemistry 2023Quote: ... the same proteins were applied to holey grids with a 2 nm carbon film (Quantifoil Cu 2/2 200 mesh from EMS). Samples were frozen after a total of 145 min on the grids without carbon film and 150 min on the grids with carbon film ...
-
bioRxiv - Biochemistry 2021Quote: ... the samples (3.5 μl) were applied onto UltraAuFoil R 2/2 gold grids (Quantifoil Micro Tools GMBH ...
-
bioRxiv - Molecular Biology 2024Quote: A QuantiFoil 200-mesh R 2/1 grid with 2 nm continuous carbon (QuantiFoil Micro Tools GmbH ...
-
bioRxiv - Cell Biology 2021Quote: Gold grids (Quantifoil, R2/2) were glow-discharged and incubated on top of 40 μL droplets of fibronectin (50 μg/mL ...
-
bioRxiv - Biochemistry 2024Quote: ... R2/2 UltrAuFoil grids (Quantifoil) were glow-discharged for 100 s ...
-
bioRxiv - Biochemistry 2024Quote: ... R2/2 UltrAuFoil grids (Quantifoil) were glow-discharged for 100 s ...
-
bioRxiv - Biophysics 2024Quote: ... 2 μL of 2 μM taxol-microtubules were incubated on a glow-discharged holey carbon cryo-EM grid (QuantiFoil, Cu 300 R 2/1) for 30 seconds ...
-
bioRxiv - Microbiology 2024Quote: ... 3 μL of purified viral particles at ∼1 mg/mL were applied during 2 min to glow-discharged Quantifoil R 2/2 grids covered with a thin carbon film (Quantifoil Micro tools GmbH, Germany), blotted for 3 s and then flash frozen in liquid ethane using the semi-automated plunge freezing device Vitrobot IV at 100% relative humidity ...
-
bioRxiv - Neuroscience 2023Quote: ... applied to glow-discharged 2/2 μm holey carbon-coated 200-mesh gold grids (Quantifoil) and plunge-frozen in liquid ethane using a Vitrobot Mark IV (Thermo Fisher) ...
-
bioRxiv - Cell Biology 2021Quote: 3 mm gold EM grids with a holey carbon film (R 2/2, 200 mesh; Quantifoil Cat no ...
-
bioRxiv - Biochemistry 2020Quote: ... 200 mesh Cu grids with Quantifoil R 2/2 holey carbon films (Quantifoil Micro Tools GmbH) were used ...
-
bioRxiv - Molecular Biology 2020Quote: QUANTIFOIL R 2/1 grids with the 2-nm carbon layer (Cu 200, Quantifoil Micro Tools) were glow discharged with 25 mA with negative polarity for 60 s in a PELCO easiGlow glow discharge unit ...