Labshake search
Citations for Quantifoil Micro Tools :
51 - 100 of 247 citations for QT Nickel Plating Process Agent For Removing Copper Impurity since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biochemistry 2022Quote: ... R3/3 copper grids with a 2 nm carbon coating (Quantifoil) using a Vitrobot mark IV (FEI ...
-
bioRxiv - Biochemistry 2023Quote: ... Quantifoil R 1.2/1.3 200 mesh Copper TEM grids (Quantifoil Microtools) and blotted for 3 sec using a Mark IV Vitrobot (FEI ...
-
bioRxiv - Cell Biology 2022Quote: ... Holey Carbon Film R 1.2/1.3 Copper 400 mesh EM grids (Quantifoil Micro Tools GmbH ...
-
bioRxiv - Microbiology 2022Quote: R2/2 carbon-coated 200 mesh copper Quantifoil grids (Quantifoil Micro Tools) were first glow-discharged for 60 seconds ...
-
bioRxiv - Biochemistry 2022Quote: ... holey carbon-coated copper grids (type R2/1 200 mesh from Quantifoil) are glow discharged using a PELCO easiGlow (15 mA ...
-
bioRxiv - Pathology 2023Quote: ... bombycis spores (1×105 spores/mL) were placed on nickel grids (Quantifoil, Beijing, China) for 15 min and germinated in 0.1 M KOH for 30 min at 30°C ...
-
bioRxiv - Plant Biology 2020Quote: ... holey carbon-coated copper grids (R 2/1, 200 mesh, Quantifoil Micro Tools). Grids were plunge-frozen in a liquid ethane/propane mixture using a Vitrobot Mark 4 (FEI ...
-
bioRxiv - Microbiology 2022Quote: Copper grids coated with holey carbon film (Quantifoil Cu 1.2/1.3, 300 mesh) were glow-discharged for 30 s at 0.45 Torr ...
-
bioRxiv - Biochemistry 2022Quote: ... holey support film type R2/1 on 200 mesh copper grid (Quantifoil, Germany) that was previously glow discharged under the following conditions ...
-
bioRxiv - Biochemistry 2023Quote: Quantifoil™ R 2/1 on 200 copper mesh (Quantifoil Micro Tools GmbH) were used immediately after glow discharging in a glow discharge cleaning system (PELCO easiGlow ...
-
bioRxiv - Bioengineering 2024Quote: ... 5 µl of protein complex was deposited on a holey copper grid (QUANTIFOIL R1.2/1.3 ...
-
bioRxiv - Biophysics 2024Quote: ... or R1.2/1.3 300 copper mesh quantifoil grid (Quantifoil Micro Tools, Großlöbichau, Germany). Grids were plunge-frozen in liquid ethane (Vitrobot Mark IV ...
-
bioRxiv - Biophysics 2024Quote: ... Samples were applied on holey carbon grids (Quantifoil R1.2/1.3, 300 mesh copper) that were previously glow-discharged using a PELCO easiGlow glow discharge apparatus for 60 s at 30 mA (Ted Pella) ...
-
bioRxiv - Biochemistry 2020Quote: Quantifoil R2/2 300 mesh holey carbon copper grids (Quantifoil Micro Tools, Großlöbichau, Germany) were glow-discharged (ELMO Glow Discharge System ...
-
bioRxiv - Biochemistry 2022Quote: ... 3 μL of sample was applied to 200-mesh copper R2/1 grids (Quantifoil), which were glow-discharged twice using a Pelco EasyGlow instrument ...
-
bioRxiv - Cell Biology 2020Quote: ... reinhardtii cells were deposited onto 200-mesh copper EM (R2/1, Quantifoil Micro Tools) and vitrified using a Vitrobot Mark 4 (FEI Thermo Fisher Scientific) ...
-
Mechanism of actin-dependent activation of nucleotidyl cyclase toxins from bacterial human pathogensbioRxiv - Biochemistry 2021Quote: ... were applied onto a freshly glow-discharged copper R2/1 300 mesh grid (Quantifoil), blotted for 3 s on both sides with blotting force −3 and plunge-frozen in liquid ethane using the Vitrobot Mark IV system (Thermo Fisher Scientific ...
-
bioRxiv - Biophysics 2024Quote: Plunge freezing of cells was performed on R2/1 SiO2 copper 200 mesh (Quantifoil) grids ...
-
bioRxiv - Microbiology 2024Quote: ... was pipetted onto a holey carbon-coated copper grid (R2/1, mesh 200; Quantifoil), blotted and vitrified by plunging into liquid ethane using a Vitrobot Mark IV (FEI) ...
-
bioRxiv - Biochemistry 2024Quote: ... The 300-mesh Quanti-foil R 1.2/1.3 copper EM grids (Quantifoil Micro Tools) were discharged at 15 mA for 60 seconds using a glow-discharger (PELCO) ...
-
bioRxiv - Pathology 2023Quote: ... and they were prepared as previously described [60] and placed on nickel grids (Quantifoil, Beijing, China). All samples were washed three times by ddH2O at room temperature ...
-
bioRxiv - Cell Biology 2021Quote: For each glow-discharged copper grid (Quantifoil Cu 200 mesh, holy carbon film R2/1) 4 μl of the supernatant were applied ...
-
bioRxiv - Microbiology 2021Quote: ... were applied to freshly washed and glow-discharged R2/2 holey carbon copper grids (Quantifoil). The grids were manually back blotted for 2 to 3s with filter paper ...
-
bioRxiv - Biophysics 2022Quote: ... except for using copper grid coated with holey carbon (R 1.2/1.3; Quantifoil, Jena, Germany), applying 4 µl virus sample and not adding fiducial beads ...
-
bioRxiv - Molecular Biology 2022Quote: ... was applied onto glow-discharged R1.2/1.3 400 mesh copper grids (Quantifoil Micro Tools, Germany). The grids were blotted for 4 s and plunge-frozen in liquid ethane with a Vitrobot Mark IV (ThermoFisher ...
-
bioRxiv - Biochemistry 2022Quote: ... The samples were applied to Quantifoil R1.2/1.3 Copper 300 mesh grids (Quantifoil Micro Tools), and were plunge-frozen with a EM GP2 (Leica ...
-
bioRxiv - Neuroscience 2022Quote: Holey copper or molybdenum EM grids (Quantifoil R 2/1 200 mesh; Quantifoil, Jena, Germany) were glow discharged (Harrick Plasma cleaner PDC-3XG ...
-
bioRxiv - Cell Biology 2022Quote: ... 3 μl of the resulting mixture was spotted onto glow-discharged copper EM grids (Quantifoil 300 Au mesh ...
-
bioRxiv - Molecular Biology 2023Quote: ... and vitrification of samples on holey carbon R 1.2/1.3 copper 300 mesh grids (Quantifoil) using a Vitrobot MarkIV device (Thermofisher ...
-
bioRxiv - Molecular Biology 2023Quote: ... 3.5 μL) were applied to precoated (2 nm) R1.2/1.3 carbon-supported copper grids (Quantifoil), blotted for 4-5 s at 4°C ...
-
bioRxiv - Biochemistry 2024Quote: ... Graphene oxide-coated Quantifoil R1.2/1.3 300 mesh copper holey carbon grids (Quantifoil Micro Tools) were glow discharged using a PELCO easiGlow Glow Discharge Cleaning system (Ted Pella ...
-
bioRxiv - Biophysics 2024Quote: ... and 3 µL were applied to glow-discharged R2/2 holey carbon copper grids (Quantifoil). These grids were manually back blotted for 2 to 3s with filter paper ...
-
bioRxiv - Cell Biology 2020Quote: ... 3.5 μL of the peak fraction from a BBSome purification (0.4 - 0.6 mg/mL) was applied to glow-discharged R1.2/1.3 holey carbon copper grids (Quantifoil) covered with a thin homemade carbon film ...
-
Mechanism of actin-dependent activation of nucleotidyl cyclase toxins from bacterial human pathogensbioRxiv - Biochemistry 2021Quote: ... the mixture was applied onto a freshly glow-discharged copper R2/1 300 mesh grid (Quantifoil), blotted for 3 s on both sides with blotting force −5 and plunge-frozen in liquid ethane using the Vitrobot Mark IV system (Thermo Fisher Scientific ...
-
bioRxiv - Bioengineering 2022Quote: ... Harrick Plasma PDC-002-EC instrument) holey carbon-coated grid (copper 200 mesh R1.2/1.3, Quantifoil). After a 1 min incubation ...
-
bioRxiv - Microbiology 2024Quote: ... 3.5 μL of the culture were applied onto glow-discharged copper EM grids (R2/1, Quantifoil), automatically blotted and plunged into liquid ethane/propane (Tivol et al ...
-
bioRxiv - Biophysics 2023Quote: ... 4 μL of Kapβ2•HNRNPH2 was applied to a 300 mesh copper grid (Quantifoil R1.2/1.3) that was glow-discharged using a PELCO easiGlow glow discharge apparatus at 30 mA/30 s on top of a metal grid holder (Ted Pella) ...
-
bioRxiv - Molecular Biology 2023Quote: ... Quantifoil R1.2/1.3 400-square mesh copper grids with a 2 nm continuous carbon layer (Quantifoil) were plasma-treated in a Pelco easiGlow glow discharging system (Ted Pella ...
-
bioRxiv - Biochemistry 2024Quote: ... 15 mA for 30 s using a PELCO easiGlow) copper R1.2/1.3 300-mesh grid (Quantifoil). The grid was blotted with a filter paper (Whatman No.1 ...
-
bioRxiv - Cell Biology 2024Quote: ... Each glow-discharged Quantifoil R2/4 200 mesh copper grid (Quantifoil Micro Tools GmbH, Jena, Germany) was then deposited with 4 µL sample and plunge-frozen in liquid ethane using a Vitrobot Mark IV (TFS ...
-
bioRxiv - Microbiology 2021Quote: ... 3μL of protein was deposited on a holey copper grids (QUANTIFOIL R 1.2/1.3, 200 mesh, EMS) which had been glow-discharged for 30s at 15 mA (Tedpella Inc) ...
-
bioRxiv - Biochemistry 2022Quote: ... Solutions were adjusted to OD600≈10 and applied to carbon-coated holey copper grids (Quantifoil R2/1). Grids were glow-discharged for 30 s in oxygen/argon atmosphere of a plasma cleaner (Gatan Solarus 950 ...
-
bioRxiv - Microbiology 2021Quote: ... 200-mesh copper grid with holey carbon film (R2/1 Cu 200, Quantifoil Micro Tools GmbH, Germany). The sample was blotted with filter paper and immediately plunge frozen in liquid ethane ...
-
bioRxiv - Microbiology 2020Quote: ... CryoET samples were prepared using copper grids with holey carbon support film (200 mesh, R2/1, Quantifoil). The grids were glow-discharged for 30 seconds before we deposited 5 μL cell solution on them ...
-
bioRxiv - Biochemistry 2023Quote: ... before it was applied onto a 300-mesh holey carbon-coated copper grid (Quantifoil, Cu R1.2/R1.3) pre-treated by glow-discharging at 15 mA for 30 s ...
-
bioRxiv - Biochemistry 2023Quote: ... 300-mesh R0.6/1.0 holey carbon copper grid (preprocessed with 0.1% poly L-lysine hydrobromide after glow-discharging) (Quantifoil), or an R1.2/1.3 amorphous nickel titanium alloy (ANTA ...
-
bioRxiv - Microbiology 2024Quote: A purified filament fraction (2 µL) was applied to a copper grid (R1.2/1.3 300 mesh; Quantifoil) and glow-discharged for 10 s using a JEC-3000FC Auto Fine Coater (JEOL) ...
-
bioRxiv - Biochemistry 2024Quote: ... Samples were absorbed on glow-discharged carbon-coated 400-meshh copper grid purchased from Quantifoil (Großlöbichau, Germany) and stained with 2 % uranyl acetate ...
-
bioRxiv - Biochemistry 2024Quote: Samples were concentrated to 0.2 mg/ml or 1 mg/ml and prepared either on copper grids with holey carbon support and an additional layer of 2 nm continuous carbon (R1.2,1.3, Quantifoil) or on UltAufoil grids (R0.6/1.0 ...
-
bioRxiv - Biochemistry 2021Quote: ... 3 microlitres of undiluted eluate and of eluate which was diluted 1:2 or 1:4 in buffer A200 were blotted onto holey carbon R 1.2/1.3 copper 300 mesh grids (Quantifoil) and vitrified in liquid ethane using a Vitrobot MarkIV device (Thermofisher) ...