Labshake search
Citations for Quantifoil Micro Tools :
51 - 100 of 406 citations for Estrone 3 Glucuronide E1G ELISA Kit 1 Plate since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Molecular Biology 2022Quote: ... 2–3 μL of sample solution was applied to a holey carbon grid (Quantifoil R2/1 ...
-
bioRxiv - Molecular Biology 2022Quote: ... Samples (3 μl) were applied to Quantifoil 1.2/1.3 Cu 300 holey-carbon grids (Quantifoil) glow-discharged 60 s using a PELCO glow-discharge system (Ted Pella) ...
-
bioRxiv - Cell Biology 2022Quote: ... 3 μl of the resulting mixture was spotted onto glow-discharged copper EM grids (Quantifoil 300 Au mesh ...
-
bioRxiv - Microbiology 2023Quote: ... sample aliquots of 3 µL were applied onto UltrAuFoil R2/2 grids (300 mesh, Quantifoil). Grids were blotted for 1 s at 10°C with 100% relative humidity and immediately plunge frozen into liquid ethane using a Vitrobot Mark IV system (TFS) ...
-
bioRxiv - Cell Biology 2021Quote: 3 mm gold EM grids with a holey carbon film (R 2/2, 200 mesh; Quantifoil Cat no ...
-
bioRxiv - Biophysics 2019Quote: ... 3 µL of the mixture was applied to glow discharged R1.2/1.3 400 mesh grids (Quantifoil). Grids were blotted with filter paper 494 (VWR ...
-
bioRxiv - Molecular Biology 2019Quote: ... The sample (3 µl) was applied to glow discharged UltrAuFoil 300 mesh R1.2/1.3 grids (Quantifoil). Grids were blotted for 1.5 s at 16° C or 22° C and ∼100 % humidity and plunge-frozen in liquid ethane using a FEI Vitrobot Mark IV ...
-
bioRxiv - Physiology 2021Quote: ... 3 µL of the vortexed dispersion were placed on glow discharged carbon-coated grids (Quantifoil, D) for 1 minute ...
-
bioRxiv - Biochemistry 2022Quote: ... 3 µL of purified PPSA was applied to glow-discharged holy grids (Quantifoil, Cu200, R2/2) for 30s ...
-
bioRxiv - Biophysics 2023Quote: ... 3 μl of the sample was applied to a hydrophilized grids (Quantifoil, R1.2/1.3+2nm carbon) with an additional 2 nm layer of amorphous carbon ...
-
bioRxiv - Plant Biology 2023Quote: ... 3 μl protein was applied to glow-discharged carbon grids (Quantifoil Cu R1.2/1.3 300 mesh). Subsequently ...
-
bioRxiv - Molecular Biology 2020Quote: 3 μL of sample was applied onto a holey carbon grid (Quantifoil, Cu, R1.2/1.3, 300 mesh) rendered hydrophilic by a 30 s glow-discharge in air (11 mA current with PIB-10) ...
-
bioRxiv - Plant Biology 2021Quote: Concentrated PSII solution (3 µl) was applied on glow-discharged holey carbon grids (Cu Quantifoil R1.2/1.3) that were vitrified for cryo-EM structural determination using a Vitrobot FEI (3 s blot at 4°C and 100% humidity) ...
-
bioRxiv - Molecular Biology 2022Quote: ... The sample (3 μL) was applied to freshly glow-discharged Au 300 mesh R1.2/1.3 grids (Quantifoil) in a Vitrobot Mark IV (FEI ...
-
bioRxiv - Biophysics 2021Quote: ... 3 μL was applied to Ultrafoil grids (R1.2/1.3, Au/Au, 300 mesh, Quantifoil Micro Tools GmbH) that had been glow-discharged for 2 min using a Pelco easiGlow (Ted Pella ...
-
bioRxiv - Pharmacology and Toxicology 2022Quote: Samples (3 µL) were applied to glow-discharged Quantifoil R1.2/1.3 Cu/Rh 200 mesh grids (Quantifoil) (M4R-Gi1-Ipx and M4R-Gi1-Ipx-LY298 ...
-
bioRxiv - Biophysics 2023Quote: ... 3 µL sample was applied to a freshly glow-discharged UltrAuFoil R1.2/1.3 300 mesh grids (Quantifoil), blotted with Whatman No ...
-
bioRxiv - Biochemistry 2023Quote: ... 3 μl diluted protein sample was put on freshly glow-discharged Quantifoil R1.2/1.3 Cu grid (Quantifoil Micro Tools GmbH ...
-
bioRxiv - Immunology 2021Quote: ... by shaking at 1200 rpm for 5 minutes at 37°C using a plate shaker (Quantifoil Instruments) after stimulating with collagen at a range of concentrations ...
-
bioRxiv - Microbiology 2021Quote: ... 3 μl of each sample was dispensed on Quantifoil R1.2/1.3 200-mesh grids (Quantifoil Micro Tools GmbH) that had been freshly glow discharged for 30 seconds at 20 mA using a PELCO easyGLow™ Glow Discharge Cleaning System (Tedpella) ...
-
bioRxiv - Immunology 2022Quote: ... 3 μl of sample was then dispensed on Quantifoil R1.2/1.3 200-mesh grids (Quantifoil Micro Tools GmbH) that had been freshly glow discharged for 30 s at 20 mA ...
-
bioRxiv - Biochemistry 2022Quote: ... 3 µl of TIR-SAVED complex was applied to Holey Carbon grids (Quantifoil Cu R1.2/1.3, 300 mesh), glow discharged for 45 s at current of 45 mA in a EMITECH K100X glow discharger ...
-
bioRxiv - Molecular Biology 2021Quote: ... 3 μl of the resultant mixture was applied to glow-discharged (EasiGlow Pelco) R2/2 Quantifoil grids (Quantifoil). Excess sample was blotted away with a FEI Vitrobot (IV ...
-
bioRxiv - Molecular Biology 2020Quote: A 3 μL sample solution was applied to a Quantifoil holey carbon grid R1.2/1.3 Mo 200 mesh (Quantifoil Micro Tools GmbH ...
-
bioRxiv - Neuroscience 2021Quote: ... Aliquots of 3 μl were applied to glow-discharged holey carbon grids (Quantifoil Au R1.2/1.3, 300 mesh) and plunge-frozen in liquid ethane using a Thermo Fisher Vitrobot Mark IV ...
-
bioRxiv - Biochemistry 2021Quote: ... A 3-μl aliquot was pipetted on a holey carbon cryo-EM grid (1.3/1.2 Cu 200 mesh, Quantifoil) and vitrified by plunge-freezing in liquid ethane (Vitrobot Mark IV ...
-
bioRxiv - Microbiology 2019Quote: UNSW-2012 and CHDC-1974 VLPs (3 μl) were applied on freshly glow discharged Quantifoil holey carbon support films (R1.2/1.3; Quantifoil) and blotted for 18 seconds at 100% humidity at 10°C before been plunged in liquid ethane using an FEI Mark IV Vitrobot (Thermo Fischer Scientific) ...
-
bioRxiv - Immunology 2021Quote: ... 3 μl of sample was then dispensed on Quantifoil R1.2/1.3 200-mesh grids (Quantifoil Micro Tools GmbH) that had been freshly glow discharged for 30 s at 20 mA ...
-
bioRxiv - Biophysics 2020Quote: 3 µl of the toroid suspension were deposited onto a glow-discharged holey carbon grid (Quantifoil R2/2), blotted with a filter paper for 4 seconds ...
-
bioRxiv - Biophysics 2021Quote: ... 3 μl sample was applied to each side of the UltrAuFoil grid (300 mesh, R 1.2/1.3, Quantifoil), which had been glow discharged on both sides (25 mA ...
-
bioRxiv - Molecular Biology 2022Quote: ... 4 µl of DELE WT CTD sample at 3 mg/ml was applied onto 300 mesh R1.2/1.3 UltraAuFoil holey gold grids (Quantifoil) that were plasma cleaned for 15 s using Pelco glow discharge cleaning system (Ted Pella ...
-
bioRxiv - Biophysics 2022Quote: ... A total of 3 µl of the solution was applied to freshly glow discharged R2.2 Cu300 grids (Quantifoil), blotted from the back side for 1.2s at 20°C and 99% humidity and immediately plunge frozen in liquid ethane using a Leica EM GP ...
-
bioRxiv - Biochemistry 2023Quote: ... Cryo-EM grids were prepared by pipetting 3 µl of sample on a R1.2/1.3 Cu 300 mesh grid (Quantifoil) and plunge-freezing in liquid ethane using a Vitrobot Mark IV (ThermoFisher).
-
bioRxiv - Biochemistry 2023Quote: ... The most concentrated fraction was spun for 5 min at 13K rpm before applying 3 µL to UltraAuFoil R1.2/1.3 gold support grids (Quantifoil). Prior to sample applications grids were glow-discharged for 3 min in Pelco easiGlow glow-discharger (Pelco ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... 3 μl of the purified complex was applied to glow-discharged holey carbon grids (Quantifoil, Au300 R1.2/1.3). Grids were plunge-frozen in liquid ethane using Vitrobot Mark IV (Thermo Fischer Scientific).
-
bioRxiv - Biophysics 2023Quote: mGluR3 samples ranging from 2.0-4.7 mg/mL were applied at a volume of 3 μL to plasma treated UltrAuFoil 1.2/1.3 300 mesh grids (Quantifoil). Vitrified samples were prepared using a Vitrobot Mk IV (Thermo Fisher) ...
-
bioRxiv - Biophysics 2023Quote: ... 3 μL of sample was applied to a freshly glow-discharged UltrAuFoil R1.2/1.3 300 mesh grids (Quantifoil), blotted for 1.5 – 2.0 s ...
-
bioRxiv - Immunology 2023Quote: ... 3 μL of the purified complex (8 mg/ml) was deposited onto a glow-discharged holey grid (Quantifoil Au 300 mesh R1.2/1.3 ...
-
bioRxiv - Biochemistry 2023Quote: ... A sample volume of 3 μL sample was applied to a freshly glow-discharged UltrAuFoil R1.2/1.3 300 mesh (Quantifoil); the sample was incubated for 1min and blotted with Whatman No ...
-
bioRxiv - Microbiology 2022Quote: ... 3 μl aliquots of the mixture was applied to R2/2 200 mesh copper Quantiofoil grids (Quantifoil Micro Tools) that were freshly glow discharged ...
-
bioRxiv - Biochemistry 2019Quote: ... 3 μl were applied onto freshly glow-discharged Quantifoil Cu/Rh R2/2 holey carbon 200 mesh grids (Quantifoil). The grids were blotted for 4 seconds with a blotting force of −15 ...
-
bioRxiv - Biophysics 2021Quote: ... aliquots (3 μL) of the concentrated protein were placed on glow-discharged holey carbon grids (Quantifoil Au R1.2/1.3) and blotted for 5 s ...
-
bioRxiv - Microbiology 2021Quote: ... 3 µl of sample were applied to a freshly glow-discharged Quantifoil Au R2/2 200 mesh grid (Quantifoil), blotted for 5.5-7.5 s (0.5 s drain time ...
-
bioRxiv - Microbiology 2021Quote: ... 3 µl of sample were applied to a freshly glow-discharged Quantifoil Au R2/2 200 mesh grid (Quantifoil), blotted for 3.5-7.5 s (0.5 s drain time ...
-
bioRxiv - Biophysics 2022Quote: Cryo-EM grids were prepared by applying 3 μL of protein to a glow-discharged QuantiAuFoil R1.2/1.3 300-mesh grid (Quantifoil, Germany) and blotted for 2.5 to 4 s under 100% humidity at 4 °C before plunging into liquid ethane using a Mark IV Vitrobot (FEI).
-
bioRxiv - Biochemistry 2020Quote: ... 3 μL of eluate (72 nM) was applied to a plasma-treated UltraAuFoil 1.2/1.3 grid (Quantifoil, Großlöbichau, Germany). The grids were hand blotted for 3 sec from the backside of the grid before being plunged into liquefied ethane.
-
bioRxiv - Biochemistry 2019Quote: ... 3 ul of sample were applied to glow-discharged holey carbon-coated grids (Quantifoil 300 mesh, Au R1.2/1.3), adsorbed for 5 s ...
-
bioRxiv - Biophysics 2022Quote: ... the pelleted cells resuspended in 100 μl NaH2PO4-NaOH pH 7.5 and a 3 μl drop adsorbed for 20 s to a carbon-coated copper grid (300 mesh, Quantifoil) that had been glow-discharged for 30 s at a current of 25 mA ...
-
bioRxiv - Microbiology 2022Quote: ... Purified BfpD was diluted to 4.5 mg/ml and 3 µl was applied to a glow-discharged 300 mesh UltraAufoil -1.2/1.3 holey-gold (Quantifoil, Germany). Grids were blotted for 2 s with ash-free Whatman® Grade 540 filter paper in a Vitrobot Mark IV (ThermoFisher Scientific ...
-
bioRxiv - Biophysics 2023Quote: ... 3 μL HA trimer (0.75 mg/ml) was applied to holey carbon grid (Quantifoil 400 mesh Au R1.2/1.3) which was glow discharged 30 s at 15 mA ...