Labshake search
Citations for Quantifoil Micro Tools :
51 - 100 of 717 citations for 6 METHYL 7 1 METHYL 2 OXO PROPOXY 2 3 DIHYDRO 1H CYCLOPENTA C CHROMEN 4 ONE since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biophysics 2021Quote: 4 µL of purified HsPepT1 at 2 mg/mL was applied to a glow discharged gold holey carbon 2/1 300-mesh grid (Quantifoil). The grid was blotted for 4 s at 0 force before being plunge vitrified in liquid propane using a Mark IV Vitrobot (ThermoFisher) ...
-
bioRxiv - Biophysics 2023Quote: ... split onto Poly-D-Lysine coated R 2/2 grids (QUANTIFOIL 100 Holey Carbon Films ...
-
bioRxiv - Biophysics 2023Quote: ... glow discharged QUANTIFOIL® copper R 2/2 grid with a 2 nm thin extra carbon layer (QUANTIFOIL, GMBH) was used ...
-
bioRxiv - Biophysics 2022Quote: ... an aliquot of 3 μL of sample was applied onto a glow-discharged holey carbon-coated copper grid (300 mesh, QUANTIFOIL® R 2/1) or holey gold grid (300 mesh ...
-
bioRxiv - Biophysics 2019Quote: ... of suspended crystals was loaded on one side of glow-discharged Quantifoil EM grids (R2/2, Cu 300 mesh; QUANTIFOIL Company). The grid was then blotted from the other side and washed twice manually with 4 μL 5% v/v PEG 200 buffer ...
-
bioRxiv - Biochemistry 2021Quote: ... Quantifoil Cu 300 mesh (R 2/2 geometry; Quantifoil Micro Tools GMBH) covered with a thin layer of 3 nm carbon were used for the for the GTPBP5KO sample ...
-
bioRxiv - Cell Biology 2021Quote: R 2/1 Holey Carbon Au 200 mesh EM grids (Quantifoil) were coated with approximately 20 nm of carbon in a MED 020 carbon coater (BAL-TEC ...
-
bioRxiv - Biochemistry 2022Quote: R2/2 grids (Quantifoil) were covered with a thin layer of continuous carbon (estimated to be 50 Å thick ...
-
bioRxiv - Cell Biology 2019Quote: ... R 2/1 or R 3.5/1 on 300 mesh Cu/Rh grids (QUANTIFOIL) were glow discharged for 45 s at 25 mA ...
-
bioRxiv - Biochemistry 2022Quote: ... Continuous carbon grids (Quantifoil R 2/2 on Cu 300 mesh grids + 2 nm Carbon, Quantifoil Micro Tools C2-C16nCu30-01) were glow-discharged for 5 sec in an easiGlow Glow Discharge Cleaning System (Ted Pella Inc.) ...
-
bioRxiv - Microbiology 2024Quote: ... Continuous carbon grids (Quantifoil R 2/2 on Cu 300 mesh grids + 2 nm Carbon, Quantifoil Micro Tools C2-C16nCu30-01) were glow-discharged for 5 sec in an easiGlow Glow Discharge Cleaning System (Ted Pella Inc.) ...
-
bioRxiv - Molecular Biology 2019Quote: ... 2.4 μl of 0.12 mg/ml of the protein preparation were applied to glow-discharged holey carbon grids (Quantifoil, QF 2/1, 300 mesh) covered with a 2 nm carbon layer ...
-
bioRxiv - Cell Biology 2024Quote: EM support grids (Au grids 200 mesh, carbon or SiO2 foil, R2/2 or R1/4, Quantifoil) were glow discharged with a Pelco easiGlow for 90 sec at 15 mA ...
-
bioRxiv - Biophysics 2020Quote: ... 3.5 µl of purified channel proteins at ∼6 mg/ml were pipetted onto glow-discharged copper Quantifoil R2/2 holey carbon grids (Quantifoil). Grids were blotted for 2 s at ∼100% humidity and flash frozen in liquid ethane ...
-
bioRxiv - Molecular Biology 2021Quote: ... 3 μl of the resultant mixture was applied to glow-discharged (EasiGlow Pelco) R2/2 Quantifoil grids (Quantifoil). Excess sample was blotted away with a FEI Vitrobot (IV ...
-
bioRxiv - Biophysics 2020Quote: 3 µl of the toroid suspension were deposited onto a glow-discharged holey carbon grid (Quantifoil R2/2), blotted with a filter paper for 4 seconds ...
-
bioRxiv - Molecular Biology 2022Quote: ... Glow-discharged carbon coated gold mesh grids (QF 2/2 AU 200, Quantifoil) were placed on the edge of the glass microscopy slides ...
-
bioRxiv - Bioengineering 2022Quote: ... holey carbon grids (Ultrafoil 25 nM Au R 2/2 200 mesh; Quantifoil) were glow-discharged for 10 s using the Solarus plasma cleaner (Gatan) ...
-
bioRxiv - Biochemistry 2023Quote: ... Cryo-EM grids (carbon-coated Quantifoil R 2/2 cupper grids, 300 mesh) were plunge-frozen using a Vitrobot IV (Thermo Fisher Scientific ...
-
bioRxiv - Biochemistry 2022Quote: ... 2 μl retromer at a concentration between 80-100 μg/ml was applied to freshly glow discharged CF-2/2-2C C-Flat grids (Protochips, Morrisville, NC) or Quantifoil R 1.2/1.3 300 mesh copper grids (Quantifoil Micro Tools GmbH ...
-
bioRxiv - Biochemistry 2023Quote: ... the same proteins were applied to holey grids with a 2 nm carbon film (Quantifoil Cu 2/2 200 mesh from EMS). Samples were frozen after a total of 145 min on the grids without carbon film and 150 min on the grids with carbon film ...
-
bioRxiv - Cell Biology 2020Quote: Gold EM grids with Quantifoil R 2/1 holey carbon film (Quantifoil Micro Tools GmbH ...
-
bioRxiv - Cell Biology 2019Quote: Holey-carbon grids (QUANTIFOIL R 2/1, Cu 200, Quantifoil Micro Tools) were coated with carbon and glow discharged with 20 mA with negative polarity for 60 seconds in a PELCO easiGlow glow discharge unit ...
-
bioRxiv - Cell Biology 2019Quote: Holey-carbon grids (QUANTIFOIL R 2/1, Cu 200, Quantifoil Micro Tools) were coated with carbon and glow discharged with 20 mA with negative polarity for 60 seconds in a PELCO easiGlow glow discharge unit ...
-
bioRxiv - Immunology 2021Quote: ... and Quantifoil R 2/1 (Cu, 400-mesh; Quantifoil Micro Tools GmbH). The grids were treated with Ar/O2 plasma (Solarus plasma cleaner ...
-
bioRxiv - Immunology 2024Quote: ... and Quantifoil R 2/1 (Cu, 400-mesh; Quantifoil Micro Tools GmbH) were used for freezing ...
-
bioRxiv - Biochemistry 2021Quote: ... the samples (3.5 μl) were applied onto UltraAuFoil R 2/2 gold grids (Quantifoil Micro Tools GMBH ...
-
bioRxiv - Microbiology 2022Quote: ... 3 μl aliquots of the mixture was applied to R2/2 200 mesh copper Quantiofoil grids (Quantifoil Micro Tools) that were freshly glow discharged ...
-
bioRxiv - Biochemistry 2019Quote: ... 3 μl were applied onto freshly glow-discharged Quantifoil Cu/Rh R2/2 holey carbon 200 mesh grids (Quantifoil). The grids were blotted for 4 seconds with a blotting force of −15 ...
-
bioRxiv - Microbiology 2021Quote: ... 3 µl of sample were applied to a freshly glow-discharged Quantifoil Au R2/2 200 mesh grid (Quantifoil), blotted for 5.5-7.5 s (0.5 s drain time ...
-
bioRxiv - Microbiology 2021Quote: ... 3 µl of sample were applied to a freshly glow-discharged Quantifoil Au R2/2 200 mesh grid (Quantifoil), blotted for 3.5-7.5 s (0.5 s drain time ...
-
bioRxiv - Cell Biology 2022Quote: The IL-11Δ10/IL-11RαD1-D3/gp130EC complex (1.5 mg/mL) in the presence of 1-2 mM n-dodecyl β-D-maltoside was blotted onto UltrAuFoil grids (R2/2, Quantifoil Micro Tools GmbH) that had been subjected to glow discharge (15 mA for 30 s) ...
-
bioRxiv - Biophysics 2023Quote: ... 0.5 μL L-PEG-L (8 mg/ml) and 0.5 μL Pd(NO3)2 (1 mg/ml) was applied to holey carbon grid (Quantifoil 200 mesh Cu R2/2) which was glow discharged 45 s at 15 mA ...
-
bioRxiv - Cell Biology 2021Quote: Gold grids (Quantifoil, R2/2) were glow-discharged and incubated on top of 40 μL droplets of fibronectin (50 μg/mL ...
-
bioRxiv - Neuroscience 2023Quote: ... applied to glow-discharged 2/2 μm holey carbon-coated 200-mesh gold grids (Quantifoil) and plunge-frozen in liquid ethane using a Vitrobot Mark IV (Thermo Fisher) ...
-
bioRxiv - Biophysics 2023Quote: ... 3 μl of medium containing one isolated muscle fibre was placed on the glow-discharged grid (Quantifoil R2/1 Au 200 mesh). After incubation for 60 seconds at 37 °C ...
-
bioRxiv - Plant Biology 2020Quote: ... holey carbon-coated copper grids (R 2/1, 200 mesh, Quantifoil Micro Tools). Grids were plunge-frozen in a liquid ethane/propane mixture using a Vitrobot Mark 4 (FEI ...
-
bioRxiv - Neuroscience 2022Quote: Holey gold EM grids (Quantifoil R 2/1, 200 mesh; Quantifoil, Jena, Germany) were plasma cleaned in a Turbo Sputter Coater Med 010 (Balzers ...
-
bioRxiv - Biochemistry 2023Quote: Quantifoil™ R 2/1 on 200 copper mesh (Quantifoil Micro Tools GmbH) were used immediately after glow discharging in a glow discharge cleaning system (PELCO easiGlow ...
-
bioRxiv - Biochemistry 2023Quote: Purified ternary complex was vitrified on holey-carbon grids (Quantifoil R 2/1) using FEI Vitrobot Mark IV ...
-
bioRxiv - Biophysics 2021Quote: ... 4 µl of this mixture was applied on a glow-discharged Quantifoil R2/2 grid (Quantifoil Micro Tools GmbH) and flash-frozen in liquid ethane using a Vitrobot Mark II device (FEI) ...
-
bioRxiv - Microbiology 2024Quote: ... 4 μL of the cell mixture was applied three times onto glow-discharged copper EM grids (R2/2, Quantifoil), followed by plunge freezing into liquid ethane/propane ...
-
bioRxiv - Biophysics 2020Quote: ... and urine were applied in 3 µl-volumes onto glow-discharged Quantifoil Au R2/2 holey carbon 300 mesh grids (Quantifoil). Grids were blotted for 2.0 s and plunged into liquid ethane cooled by liquid nitrogen ...
-
bioRxiv - Molecular Biology 2020Quote: 3.5 µl of the concentrated sample were applied to glow discharged copper grids with holey carbon support and a 2 nm continuous carbon layer (R3/3, Quantifoil). Grids were blotted in a Vitrobot Mark IV (FEI Company ...
-
bioRxiv - Microbiology 2021Quote: ... An aliquot (3 μl) of this mixture was applied to a glow-discharged holey carbon grid (QF R2/2 Cu, QUANTIFOIL), blotted with Whatman® No ...
-
bioRxiv - Biochemistry 2023Quote: ... 3 µL of each sample was applied to glow-discharged (PELCO easiGlow, 15 mA, 2 min) holey carbon grid (Quantifoil R1.2/1.3 on gold or copper 200 mesh support) ...
-
bioRxiv - Cell Biology 2024Quote: ... 3 µl of cell suspension was applied to a freshly grown discharged holey carbon grid (Quantifoil® #200, R2/2). Grids were immediately blotted from the back side using Whatman filter paper #1 (GE Healthcare ...
-
bioRxiv - Biochemistry 2019Quote: ... 2 μl 60 μM H6-TtBac in Buffer C were added onto freshly glow-discharged Quantifoil Cu/Rh R2/2 holey carbon 200 mesh grids (Quantifoil). The grids were blotted for 2.5 s with a blotting force of −15 ...
-
bioRxiv - Biochemistry 2022Quote: ... 3.0 μL of sample was applied to glow-discharged 200-mesh copper 2 nm C R1.2/1.3 cryo-EM grids (Quantifoil Micro Tools), blotted 1 s at 100 % humidity ...
-
bioRxiv - Biochemistry 2022Quote: ... 2.5 μL of sample was applied to glow-discharged 200-mesh copper 2 nm C R1.2/1.3 cryo-EM grids (Quantifoil Micro Tools), blotted 3 s at 75 % humidity ...