Labshake search
Citations for Quantifoil Micro Tools :
51 - 100 of 512 citations for 4 5 5 5 Tetrafluoro 4 trifluoromethoxy pentan 2 one since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Cell Biology 2024Quote: ... and then 4 μL of the sample was applied to the glow-discharged R1/4 Carbon 200-mesh gold EM grid (Quantifoil Micro Tools). The EM grid was incubated in the chamber of Vitrobot (Vitrobot Mark 4 ...
-
bioRxiv - Biochemistry 2023Quote: 3 μl of 50 μM purified insulin in 20 mM sodium phosphate buffer containing (pH 7.5) containing 100 mM NaCl was applied onto a grow discharged Quantifoil R1.2/1.3 Cu 200 grid (Quantifoil Micro Tool GmbH) and subsequently blotted by filter papers and plunged into liquid ethane for the vitrification using a Vitrobot Mark IV (Thermo Fisher Scientific) ...
-
Genome modularization reveals overlapped gene topology is necessary for efficient viral reproductionbioRxiv - Synthetic Biology 2020Quote: A 4 μL solution of co-isolated small particles were applied to glow-discharged copper grids (Quantifoil R2/2, Quantifoil Micro Tools), blotting for 3-seconds at 4 °C with 90% humidity and plunging into liquid ethane using a Lecia EM GP device (Leica Microsystems ...
-
Genome modularization reveals overlapped gene topology is necessary for efficient viral reproductionbioRxiv - Synthetic Biology 2020Quote: A 4 μL solution of co-isolated small particles were applied to glow-discharged copper grids (Quantifoil R2/2, Quantifoil Micro Tools), blotting for 3-seconds at 4 °C with 90% humidity and plunging into liquid ethane using a Lecia EM GP device (Leica Microsystems ...
-
Mycobacteria form viable cell wall-deficient cells that are undetectable by conventional diagnosticsbioRxiv - Microbiology 2022Quote: ... of which 3-4 µL was applied on glow-discharged 200 mesh copper grids with an extra thick R2/2 carbon film (Quantifoil Micro Tools). Vitrification was performed using an automated Leica EM GP plunge-freezer ...
-
bioRxiv - Biochemistry 2024Quote: Grids for cryo-EM were prepared by applying 4 µL of sample on a glow-discharged Quantifoil 300 mesh Cu 2/1 grid (Quantifoil Micro Tools), blotting for 7.5 seconds ...
-
bioRxiv - Biophysics 2021Quote: ... 3.5 µl sample applied to a glow-discharged Quantifoil R1.2/1.3 400-mesh gold holey carbon grid (Quantifoil, Micro Tools GmbH, Germany), blotted under 100% humidity at 4 °C and plunged into liquid ethane using a Mark IV Vitrobot (FEI) ...
-
bioRxiv - Microbiology 2021Quote: A 2.5-ml suspension of the purified medusavirus particles was applied to a quantifoil grid (R1.2/1.3 Mo) (Quantifoil Micro Tools GmbH, Germany), which was glow-discharged beforehand for 30 s ...
-
PSGL-1 inhibits HIV-1 infection by restricting actin dynamics and sequestering HIV envelope proteinsbioRxiv - Microbiology 2020Quote: ... A 3.5 µL virus sample solution was applied onto a glow discharged copper grid coated with holey carbon (R2/1; Quantifoil, Jena, Germany) prior to plunge-freezing ...
-
bioRxiv - Cell Biology 2022Quote: ... 3.5 µL of sample were applied to glow discharged (45s 30 mA) 1.2/1.3 Ultrafoil holey grids (Quantifoil Micro Tools GmbH, Germany) and they were plunged frozen in liquid ethane with a Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Neuroscience 2020Quote: ... 3.5 uL of sample was applied at a concentration of 3-5 mg/mL to glow-discharged holey carbon grids (Quantifoil R1.2/1.3). The grids were blotted using an FEI Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Biophysics 2021Quote: ... 3.5 μL sample with addition of 0.05% β-OG was directly applied to glow-discharged 200 mesh gold grids (Quantifoil R1.2/1.3) and vitrified using a FEI Vitrobot Mark IV (Thermo Fisher Scientific) ...
-
bioRxiv - Biophysics 2021Quote: Gold EM grids with R1/4 holey SiO2 film (Quantifoil) were glow-discharged in a EasiGlow (Pelco ...
-
bioRxiv - Biophysics 2023Quote: 200 mesh Au grids with R1/4 SiO2 foil (Quantifoil) were glow-discharged for 90 sec at 0.38 mBar and 15 mA using a Pelco easiGlow device ...
-
bioRxiv - Biochemistry 2022Quote: ... or AE1-Niflumic acid at 5 mg/ml were applied to glow-discharged holey carbon EM grids (Quantifoil 300 copper mesh, R1.2/1.3) in an EM-GP2 plunge freezer (Leica) ...
-
bioRxiv - Biochemistry 2021Quote: ... 3 μL of protein solution at 5 mg/mL (with 0.025% DDM) was applied onto a glow-discharged holey carbon grid (Quantifoil, 300 mesh, R1.2/1.3). Excess samples were blotted for 5.0 s with a blotting force of 3 ...
-
bioRxiv - Biophysics 2021Quote: ... 2.5 μL of each purified CCKAR–G protein complex was applied individually onto the glow-discharged holey carbon grids (Quantifoil, Au300 R1.2/1.3) in a Vitrobot chamber (FEI Vitrobot Mark IV) ...
-
bioRxiv - Biochemistry 2024Quote: ... 3.5 μL of this protein-DNA mix were applied to 300-mesh copper R2/1 Quantifoil Holey Carbon Grids (Quantifoil Micro Tools GmbH) that had been freshly glow discharged for 30 seconds at 25 mA in a GloQube Glow Discharge System (Quorum Technologies ...
-
bioRxiv - Molecular Biology 2022Quote: The purified complex samples (3 μL at 5-8 mg/mL) were applied to glow-discharged holey grids (Quantifoil R1.2/1.3, 300 mesh) and subsequently vitrified using a Vitrobot Mark IV (ThermoFisher ...
-
bioRxiv - Molecular Biology 2021Quote: ... 4 μl of protein sample (about 0.73 mg/ml) was applied onto a glow-discharged holey carbon grid (Quantifoil Au, R2/2, 300 mesh). After blotting for 3 s ...
-
bioRxiv - Neuroscience 2022Quote: ... Gold Quantifoil grids (R1/4, Au 200 mesh, Quantifoil Micro Tools) were additionally coated with a 20-25 nm carbon layer (MED 020 ...
-
bioRxiv - Cell Biology 2024Quote: ... with holey R 1/4 carbon film (Quantifoil Micro Tools GmbH) were glow-discharged for 30 seconds at 5 mA using an EasiGlow system (Pelco ...
-
bioRxiv - Microbiology 2021Quote: ... 5 µl of the cell suspension was placed on freshly glow-discharged (for ∼25 s) holey carbon grids (Quantifoil Cu R2/1, 200 mesh). The grids were front blotted with Whatman filter paper and rapidly frozen in liquid ethane ...
-
bioRxiv - Biophysics 2021Quote: ... 3 μL of the purified lasmiditan–5-HT1F–Gi complex at concentration ∼15 mg/ml were applied onto a glow-discharged holey carbon grid (Quantifoil R1.2/1.3 Au 300). Grids were plunge-frozen in liquid ethane using Vitrobot Mark IV (Thermo Fisher Scientific) ...
-
bioRxiv - Biophysics 2023Quote: ... 3 μL of purified mGlu5 (with the different ligands) at 5 mg/ml was applied on glow-discharged holey carbon gold grids (Quantifoil R1.2/1.3, 200 mesh). The grids were blotted using a Vitrobot Mark IV (FEI ...
-
bioRxiv - Molecular Biology 2023Quote: Freshly purified ZorAB sample was concentrated to 2-3 mg/mL and 2.7 μL protein was applied onto the glow-discharged (30 s, 5 mA) grids (Quantifoil R0.6/1 300 mesh Au) and plunge-frozen into liquid ethane using a Vitrobot Mark IV (FEI ...
-
bioRxiv - Microbiology 2020Quote: ... A small volume (4 µL) of cells was then transferred onto freshly glow‐discharged copper R2/2 200 Quantifoil holey carbon grids (Quantifoil Micro Tools GmbH, Jena, Germany). Grids were then blotted and plunge‐frozen in a liquid ethane/propane mixture 31 using an FEI Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Microbiology 2023Quote: ... Gold grids with SiO2 film (Quantifoil, Au 200 mesh, R 1/4) were glow- discharged and coated with 20 µg/ml fibronectin solution for 30 min ...
-
bioRxiv - Immunology 2023Quote: ... respectively) and 3 μl were kept 5 min at RT until their application onto glow-discharged holey carbon grids (Quantifoil, Au 300 mesh, R 0.6/1). The grids were blotted and then plunged into liquid ethane using a FEI Vitrobot Mark IV at 20°C and 95% relative humidity ...
-
bioRxiv - Biophysics 2021Quote: ... with 12-nm-thick holey R1/4 and R1.2/20 SiO2 film (Quantifoil) were used for the experiments ...
-
bioRxiv - Cell Biology 2021Quote: ... Gold Quantifoil grids (R1/4, Au 200 mesh grid, SiO2, Quantifoil Micro Tools) were glow-discharged and UV irradiated for 30 min for sterilization before being immersed in cell culture medium in 35-mm IBIDI μ-Dish ...
-
bioRxiv - Synthetic Biology 2023Quote: 4 µl of sample was adsorbed onto holey carbon-coated grid (Quantifoil, Germany) that was glow-discharged ...
-
bioRxiv - Neuroscience 2024Quote: ... gold mesh grids with holey R1/4 SiO2 film (Quantifoil Micro Tools GmbH) were glow discharged for 60s at 15 mA using an EasiGlow system ...
-
bioRxiv - Cell Biology 2024Quote: EM grids (Quantifoil R 1/4 Au 200 mesh, Quantifoil Micro Tools GmbH) were glow discharged with an Edwards S150B glow discharger at 30mA for 45sec on both sides of the grid ...
-
bioRxiv - Cell Biology 2024Quote: 4 µl of yeast cells were pipetted on Cu R2/1 grids (Quantifoil), blotted manually from the backside of the grid for ∼4 s and plunge frozen in liquid ethane using a manual plunger ...
-
bioRxiv - Plant Biology 2024Quote: 4 μL AtEDS1-AtPAD4-AtADR1 complex purified from Nb leaves was applied to glow-discharged Quantifoil holey carbon grids (Quantifoil Cu R1.2/1.3+2 nm C, 300 mesh). The protein was concentrated to 0.9 mg/mL prior to freezing ...
-
bioRxiv - Biophysics 2020Quote: ... 4 µl sample was applied to each freshly glow-discharged grid (Quantifoil, R1.2/1.3). The grids were then plunge-frozen in liquid ethane ...
-
bioRxiv - Microbiology 2021Quote: ... 4-7 µl of cells were deposited on R2/1 Cu 200 grids (Quantifoil) that had been glow-discharged for 1 min at 0.19 mbar and 20 mA in a PELCO easiGlow device shortly before use ...
-
bioRxiv - Biophysics 2021Quote: ... 4 μl of cell suspension was applied to holey carbon R2/1 Cu grids (Quantifoil) and plunge-frozen on a Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Biochemistry 2023Quote: ... 4 μl of sample was applied to glow discharged Quantifoil 300 mesh 1.2/1.3 (Quantifoil) grids at 4 °C and 90-100% humidity ...
-
bioRxiv - Cell Biology 2024Quote: Quantifoil R2/1 or SiO2 R1/4 gold grids (both Quantifoil Mirco Tools GmbH, Germany) were briefly washed in chloroform and placed on drops of poly-D-lysine (100 µg/ml) ...
-
bioRxiv - Biophysics 2024Quote: ... 4 µl of this sample was then applied to plasma-cleaned holey carbon grids (Quantifoil) and plunge frozen with an FEI vitrobot mark IV at 4°C and 100% humidity.
-
bioRxiv - Biophysics 2024Quote: 4 μL of sample were applied onto an UltrAuFoil grid (Quantifoil R1.2/1.3, 300 mesh), which was rendered hydrophilic by a 90 s treatment in an ELMO glow discharge system operating at 3 mA and in a partial vacuum of 3.6 × 10-1 mbar ...
-
bioRxiv - Biochemistry 2020Quote: ... 4 µL of sample was applied to Quantifoil Cu R 1.2/1.3 grids (Quantifoil Microtools GmbH) which has undergone a plasma discharge and were vitrified in liquid ethane using a Vitrobot MkIV plunge freezer (Thermo Fisher Scientific) ...
-
bioRxiv - Biophysics 2021Quote: ... Aliquots of 4 µl were applied to glow-discharged 300 mesh R1.2/1.3 Au grids (Quantifoil) using a Vitrobot Mark VI (Thermo Fisher Scientific ...
-
bioRxiv - Biophysics 2023Quote: ... 4 μL of Kapβ2•HNRNPH2 was applied to a 300 mesh copper grid (Quantifoil R1.2/1.3) that was glow-discharged using a PELCO easiGlow glow discharge apparatus at 30 mA/30 s on top of a metal grid holder (Ted Pella) ...
-
bioRxiv - Cell Biology 2024Quote: ... Each glow-discharged Quantifoil R2/4 200 mesh copper grid (Quantifoil Micro Tools GmbH, Jena, Germany) was then deposited with 4 µL sample and plunge-frozen in liquid ethane using a Vitrobot Mark IV (TFS ...
-
bioRxiv - Molecular Biology 2024Quote: ... 4 µl of sample was applied onto 300 mesh R1.2/1.3 UltraAuFoil Holey Gold grids (Quantifoil), which were plasma cleaned for 15 seconds using a Pelco glow discharge cleaning system (TED PELLA ...
-
bioRxiv - Molecular Biology 2024Quote: ... 4 µl of the sample was applied onto freshly glow-discharged R2/1 carbon grids (Quantifoil), followed by grid blotting for 4 s and plunging into liquid ethane using a Vitrobot Mark IV (FEI ...
-
bioRxiv - Biophysics 2022Quote: A volume of 4-7 µl of cells were deposited on R2/1 Cu 200 grids (Quantifoil) that had been glow-discharged for 1 min at 0.19 mbar and 20 mA in a PELCO easiGlow device shortly before use ...