Citations for Quantifoil Micro Tools :
51 - 100 of 717 citations for 3 3 2 3 Dimethyl indol 1 yl 2 hydroxy propylamino propan 1 ol since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biophysics 2024Quote: ... Cryo-EM grids were obtained by flash-freezing 3 µL of purified IPNV particles on glow-discharged holey carbon grids (Quantifoil R2/2, Cu 300 mesh; Quantifoil Micro Tools GmbH). The grids were plunge-frozen in liquid ethane after blotting for 3 s under 4°C ...
-
bioRxiv - Microbiology 2020Quote: ... 3.5 μl of the freshly prepared mixture of the soluble S trimer and monomeric ACE2 (1:3 molar ratio) at ~1 mg/ml was applied to a 1.2/1.3 Quantifoil grid (Quantifoil Micro Tools GmbH, Germany), which had been glow discharged with a PELCO easiGlow™ Glow Discharge Cleaning system (Ted Pella ...
-
bioRxiv - Biochemistry 2022Quote: ... 3 μl of sample were applied onto a freshly glow-discharged copper R2/1 300 mesh grid (Quantifoil), blotted for 8 s on both sides with blotting force −15 and plunge-frozen in liquid ethane.
-
bioRxiv - Biochemistry 2022Quote: ... 3 μl of sample were applied onto a freshly glow-discharged copper R2/1 300 mesh grid (Quantifoil), blotted for 8 s on both sides with blotting force −15 and plunge-frozen in liquid ethane.
-
bioRxiv - Molecular Biology 2022Quote: ... 3 μl of protein sample was applied to holey carbon grids (Quantifoil, R 0.6/1 Cu 200 mesh) which were H2/O2 glow-discharged for 30 s ...
-
bioRxiv - Biochemistry 2022Quote: ... 3 μl of purified PP2A-PME-1 complex was applied onto a glow-discharged holey carbon grid (Quantifoil 300 mesh R 1.2/1/3 with ultrathin carbon ...
-
Mechanism of actin-dependent activation of nucleotidyl cyclase toxins from bacterial human pathogensbioRxiv - Biochemistry 2021Quote: ... 3 μl of sample were applied onto a freshly glow-discharged copper R2/1 300 mesh grid (Quantifoil), blotted for 8 s on both sides with blotting force −20 and plunge-frozen in liquid ethane.
-
bioRxiv - Molecular Biology 2022Quote: ... aliquots of 3 μl were applied to glow discharged grids (R2/1 or R1.2/1.3, Au 300, Quantifoil), blotted for 2 s and immediately plunge-frozen in liquid ethane using an FEI Vitrobot IV at 4°C and 100 % humidity ...
-
bioRxiv - Physiology 2023Quote: ... Sample solution (~ 3 μl) was applied on freshly glow discharge TEM grids (Quantifoil R2/1, Cu, mesh 200) and plunge-frozen in liquid ethane using Vitrobot Mark IV (Thermo Fisher Scientific) ...
-
bioRxiv - Biochemistry 2024Quote: ... 3 µl of sample was applied onto a freshly glow- discharged copper R2/1 300 mesh grid (Quantifoil), blotted for 8 s on both sides with blotting force -15 and plunge-frozen in liquid ethane using the Vitrobot Mark IV system (Thermo Fisher Scientific ...
-
bioRxiv - Biochemistry 2022Quote: KRASGTPase/BRAFWT/MEK1SASA/14-3-3 complex in SEC buffer was applied to glow-discharged holey carbon grids (Quantifoil R1.2/1.3, 400 mesh) and vitrified using a Leica EM GP ...
-
bioRxiv - Microbiology 2024Quote: ... Sample volumes of 3.5 µl (8 OD260 per ml) were applied to grids (Quantifoil, Cu, 300 mesh, R3/3 with 3 nm carbon) which had been freshly glow-discharged using a GloQube (Quorum Technologies ...
-
bioRxiv - Biochemistry 2024Quote: Sample volumes of 3.5 μl (8 OD260 per ml) were applied to grids (Quantifoil, Cu, 300 mesh, R3/3 with 3 nm carbon) which had been freshly glow-discharged using a GloQube (Quorum Technologies ...
-
bioRxiv - Biochemistry 2022Quote: ... Samples were prepared by depositing 3 μl of the crystalline slurry onto a glow-discharged EM grid (Quantifoil, Cu 200 mesh, R2/2 holey carbon). Excess liquid was blotted away and the sample was vitrified using a Leica GP2 vitrification robot ...
-
bioRxiv - Microbiology 2020Quote: ... 3.5 μl of that mixture was transferred to a 3 mm freshly glow-discharged Quantifoil R2/2 Cu 300 mesh holey carbon grid (Quantifoil Micro Tools GmbH, Jena, Germany). Excess liquid was blotted away using a Leica EM GP plunge-freezer at room temperature and 80% humidity (blot time 2-3 sec ...
-
bioRxiv - Molecular Biology 2022Quote: ... The pellet was then resuspended in warm EM buffer and 3 μL of this sample was applied to a carbon on gold grid (Quantifoil R2/2 Au 200 mesh), recently glow-discharged for 1 min at 30 mA ...
-
bioRxiv - Neuroscience 2020Quote: ... covered with either 2 nm amorphous carbon (Quantifoil, R2/1+2 nm C) or graphene were used for sample preparation ...
-
bioRxiv - Molecular Biology 2021Quote: Copper grids with holey carbon support film (R3/3, Quantifoil) and a 2 nm pre-coated continuous carbon layer on top were glow discharged at 2.2 × 10-1 mbar for 20 s ...
-
bioRxiv - Molecular Biology 2020Quote: ... at 13 °C and 100% humidity: 3 μl of sample were applied onto a freshly glow-discharged copper R2/1 300 mesh grid (Quantifoil), blotted for 8 s on both sides with blotting force −20 and plunge-frozen in liquid ethane.
-
bioRxiv - Biochemistry 2020Quote: ... A volume of 3 μL of the sample was applied to a glow-discharged grid (Quantifoil R2/1 300 mesh) at 25 °C and 90 % humidity ...
-
bioRxiv - Cell Biology 2021Quote: ... 3 µl of the samples at 1 µg/µl was applied to UltrAUfoil R1.2/1.3 grids (Quantifoil Micro Tools GmbH). Grids were glow-discharged for 30 sec at 15 mA prior to sample application (PELCO easiGlow™ ...
-
bioRxiv - Biochemistry 2022Quote: 2.8 µl of F-actin sample (3 – 16 µM) was pipetted onto a glow-discharged R2/1 Cu 300 mesh holey-carbon grid (Quantifoil). After incubating for 1 – 2 seconds ...
-
bioRxiv - Molecular Biology 2024Quote: A QuantiFoil 200-mesh R 2/1 grid with 2 nm continuous carbon (QuantiFoil Micro Tools GmbH ...
-
bioRxiv - Biochemistry 2023Quote: ... A 3 µL drop was applied to a glow-discharged (PELCO easiGlow, 15 mA, 2 min) holey carbon grid (Quantifoil R1.2/1.3 on gold 200 mesh support), blotted for 3-4 seconds with Whatman Grade 595 filter paper (GE Healthcare) ...
-
bioRxiv - Biophysics 2024Quote: Approximately 3□μL of the sample solution were put on newly glow-discharged TEM grids (Quantifoil R2/1, Cu, mesh 200) and plunge-frozen in liquid ethane using the Vitrobot Mark IV (Thermo Fisher Scientific) ...
-
bioRxiv - Biochemistry 2021Quote: ... 3 μl was applied to a freshly glow-discharged grid (Quantifoil R0.6/1 Cu 300 mesh grid ...
-
bioRxiv - Biophysics 2020Quote: ... 2.5 μl samples of GDN-purified proteins at a concentration of 1.5-3 mg ml−1 were applied to glow-discharged holey carbon grids (Quantifoil R1.2/1.3 or R0.6/1 Au 200 mesh). Excess liquid was removed in a controlled environment (4°C and 100% relative humidity ...
-
bioRxiv - Biophysics 2023Quote: ... 3 μl of medium containing one isolated muscle fibre was placed on the glow-discharged grid (Quantifoil R2/1 Au 200 mesh). After incubation for 60 seconds at 37 °C ...
-
bioRxiv - Molecular Biology 2020Quote: QUANTIFOIL R 2/1 grids with the 2-nm carbon layer (Cu 200, Quantifoil Micro Tools) were glow discharged with 25 mA with negative polarity for 60 s in a PELCO easiGlow glow discharge unit ...
-
bioRxiv - Microbiology 2024Quote: ... copper EM grids (Cu 200 R 2/1, Quantifoil) were used ...
-
bioRxiv - Microbiology 2020Quote: ... 3 μL of the sample was applied to a glow-discharged R2/1 300 mesh holey carbon copper grid (Quantifoil Micro Tools GmbH) and plunge-frozen in liquid ethane using a Vitrobot Mark IV (FEI ...
-
bioRxiv - Microbiology 2020Quote: ... 3 μL of diluted sample was applied to a glow-discharged (R2/1 300 mesh holey carbon copper grid (Quantifoil Micro Tools GmbH) and plunge-frozen in liquid ethane using a Vitrobot Mark IV (FEI ...
-
bioRxiv - Molecular Biology 2022Quote: ... 3 μL of sample (10 μM EGFP in PBS) was deposited onto glow-discharged grids (Electron Microscopy Science and Quantifoil – see Table 1), prior to blotting the grids from the sample-side for 3 seconds.
-
bioRxiv - Biochemistry 2022Quote: Samples (3 μl) were applied onto a glow-discharged UltrAuFoil grid (Quantifoil GmbH) and were flash-frozen in liquid ethane using the Vitrobot mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Biochemistry 2024Quote: Samples (3 μl) were applied onto a glow-discharged UltrAuFoil grid (Quantifoil GmbH) and were flash frozen in liquid ethane using the Vitrobot mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Biochemistry 2024Quote: ... 3 µl) were deposited onto UltraAuFoil R1.2/1.3 300 gold mesh grids (QuantiFoil) that were plasma cleaned before use ...
-
bioRxiv - Biophysics 2021Quote: ... A suspension containing a mixture of 10 nm protein A coated colloidal gold (Aurion) and Ebola VLPs was applied with a volume of 3 µl on a glow discharged EM grid (Quantifoil, 200 Mesh, R2/1). The grid was blotted using No.1 Whatman paper for 3 sec from the back-side in a chamber with controlled humidity set to 70% and the temperature set to 24°C.
-
bioRxiv - Molecular Biology 2023Quote: Freshly purified ZorAB sample was concentrated to 2-3 mg/mL and 2.7 μL protein was applied onto the glow-discharged (30 s, 5 mA) grids (Quantifoil R0.6/1 300 mesh Au) and plunge-frozen into liquid ethane using a Vitrobot Mark IV (FEI ...
-
bioRxiv - Biophysics 2024Quote: ... 2 μL of 2 μM taxol-microtubules were incubated on a glow-discharged holey carbon cryo-EM grid (QuantiFoil, Cu 300 R 2/1) for 30 seconds ...
-
bioRxiv - Biophysics 2022Quote: Cryo-EM grids were prepared by applying 3 μL of sample (at the native 1 nM concentration) on glow discharged holey gold grids (Quantifoil Cu 1.2/1.3 400 mesh). Excess sample was removed by blotting with filter paper for 4 sec prior to plunge-freezing in liquid ethane using a FEI Vitrobot Mark IV at 100% humidity and 4 °C ...
-
bioRxiv - Molecular Biology 2020Quote: Cryo-EM grids were prepared by applying 3 µL sample (at a protein concentration of 1 mg/ml) on glow-discharged holey gold grids (Quantifoil Au 1.2/1.3 300 mesh). Excess sample was removed by blotting with filter paper for 2-3 s before plunge-freezing in liquid ethane (cooled to −181 °C ...
-
bioRxiv - Cell Biology 2024Quote: Vitrified grids were prepared by applying 3 µl of 1 uM complex sample to a freshly glow- discharged holey carbon grids (Quantifoil R1.2/1.3 Au 200 mesh). The sample was blotted for 3-5 s at 4 ℃ with 100% humidity and plunged-frozen in liquid nitrogen cooled ethane (FEI TM ...
-
bioRxiv - Cell Biology 2020Quote: All samples were imaged on carbon coated 3 mm gold EM finder grids (Quantifoil). Bead test and calibration samples were made by adding 2 µl of 175 nm fluorescent bead solution(Thermo Fisher PS-Speck) ...
-
bioRxiv - Cell Biology 2021Quote: R 2/1 Holey Carbon Au 200 mesh EM grids (Quantifoil) were coated with approximately 20 nm of carbon in a MED 020 carbon coater (BAL-TEC ...
-
bioRxiv - Molecular Biology 2022Quote: ... The plus carbon sample (Quantifoil Cu300 R2/1 + 2 nm C) was blotted for 2 s with blot force +3 after a 30 s wait time after sample application and immediately plunge frozen in liquid ethane ...
-
bioRxiv - Immunology 2023Quote: ... respectively) and 3 μl were kept 5 min at RT until their application onto glow-discharged holey carbon grids (Quantifoil, Au 300 mesh, R 0.6/1). The grids were blotted and then plunged into liquid ethane using a FEI Vitrobot Mark IV at 20°C and 95% relative humidity ...
-
bioRxiv - Biophysics 2021Quote: 4 µL of purified HsPepT1 at 2 mg/mL was applied to a glow discharged gold holey carbon 2/1 300-mesh grid (Quantifoil). The grid was blotted for 4 s at 0 force before being plunge vitrified in liquid propane using a Mark IV Vitrobot (ThermoFisher) ...
-
bioRxiv - Molecular Biology 2022Quote: ... Samples (3 μl) were applied to Quantifoil 1.2/1.3 Cu 300 holey-carbon grids (Quantifoil) glow-discharged 60 s using a PELCO glow-discharge system (Ted Pella) ...
-
bioRxiv - Cell Biology 2022Quote: ... 3 μl of the resulting mixture was spotted onto glow-discharged copper EM grids (Quantifoil 300 Au mesh ...
-
bioRxiv - Biochemistry 2024Quote: ... 3 μL samples were applied to the discharged UltrAuFoil R1.2/1.3 gold 300 mesh (Quantifoil). Grids were blotted for 3 sec and plunged into liquid ethane at 100% humidity at 8 °C ...