Labshake search
Citations for Quantifoil Micro Tools :
51 - 100 of 528 citations for 2 Trimethylsilyl Furo 3 2 B Pyridine 6 Carbaldehyde since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Cell Biology 2021Quote: Gold grids (Quantifoil, R2/2) were glow-discharged and incubated on top of 40 μL droplets of fibronectin (50 μg/mL ...
-
bioRxiv - Biochemistry 2024Quote: ... R2/2 UltrAuFoil grids (Quantifoil) were glow-discharged for 100 s ...
-
bioRxiv - Biochemistry 2024Quote: ... R2/2 UltrAuFoil grids (Quantifoil) were glow-discharged for 100 s ...
-
bioRxiv - Microbiology 2024Quote: ... 3 μL of purified viral particles at ∼1 mg/mL were applied during 2 min to glow-discharged Quantifoil R 2/2 grids covered with a thin carbon film (Quantifoil Micro tools GmbH, Germany), blotted for 3 s and then flash frozen in liquid ethane using the semi-automated plunge freezing device Vitrobot IV at 100% relative humidity ...
-
bioRxiv - Biophysics 2024Quote: ... 2 μL of 2 μM taxol-microtubules were incubated on a glow-discharged holey carbon cryo-EM grid (QuantiFoil, Cu 300 R 2/1) for 30 seconds ...
-
bioRxiv - Neuroscience 2023Quote: ... applied to glow-discharged 2/2 μm holey carbon-coated 200-mesh gold grids (Quantifoil) and plunge-frozen in liquid ethane using a Vitrobot Mark IV (Thermo Fisher) ...
-
bioRxiv - Biophysics 2020Quote: ... and urine were applied in 3 µl-volumes onto glow-discharged Quantifoil Au R2/2 holey carbon 300 mesh grids (Quantifoil). Grids were blotted for 2.0 s and plunged into liquid ethane cooled by liquid nitrogen ...
-
bioRxiv - Molecular Biology 2020Quote: 3.5 µl of the concentrated sample were applied to glow discharged copper grids with holey carbon support and a 2 nm continuous carbon layer (R3/3, Quantifoil). Grids were blotted in a Vitrobot Mark IV (FEI Company ...
-
bioRxiv - Microbiology 2021Quote: ... An aliquot (3 μl) of this mixture was applied to a glow-discharged holey carbon grid (QF R2/2 Cu, QUANTIFOIL), blotted with Whatman® No ...
-
bioRxiv - Cell Biology 2023Quote: ... An aliquot of 3 ul cell suspension was applied to the glow-discharged holey carbon-coated copper (R 2/1, 200 mesh) (Quantifoil) and blotted for 9 seconds by Leica GP2 (Leica Microsystems) ...
-
bioRxiv - Cell Biology 2024Quote: ... 3 µl of cell suspension was applied to a freshly grown discharged holey carbon grid (Quantifoil® #200, R2/2). Grids were immediately blotted from the back side using Whatman filter paper #1 (GE Healthcare ...
-
bioRxiv - Biochemistry 2023Quote: ... 3 µL of each sample was applied to glow-discharged (PELCO easiGlow, 15 mA, 2 min) holey carbon grid (Quantifoil R1.2/1.3 on gold or copper 200 mesh support) ...
-
bioRxiv - Neuroscience 2024Quote: Plunge-freezing VLPs: 3 µL of crude enriched VLP resuspension was applied to Holey copper R2/2 grids (Quantifoil GmBH) glow-discharged at 5mA 30s using an EasiGlow system (Pelco) ...
-
bioRxiv - Biochemistry 2020Quote: ... 200 mesh Cu grids with Quantifoil R 2/2 holey carbon films (Quantifoil Micro Tools GmbH) were used ...
-
bioRxiv - Molecular Biology 2020Quote: QUANTIFOIL R 2/1 grids with the 2-nm carbon layer (Cu 200, Quantifoil Micro Tools) were glow discharged with 25 mA with negative polarity for 60 s in a PELCO easiGlow glow discharge unit ...
-
bioRxiv - Cell Biology 2023Quote: ... the cells were seeded on Quantifoil R 2/2 200 gold mesh grids (Quantifoil, Großlöbichau, Germany) coated with 100 mg/mL poly-L-lysine and 50 µg/mL collagen I ...
-
bioRxiv - Biophysics 2022Quote: ... R2/2 Cu 300 grids (Quantifoil) were glow-discharged for 1 min at 0.19 mbar and 20 mA in a PELCO easiGlow device ...
-
bioRxiv - Microbiology 2020Quote: ... or Quantifoil R2/2 (Quantifoil, Germany). The samples were cryo-fixed by plunge freezing at −180°C in liquid ethane using a Leica EMGP (Leica ...
-
bioRxiv - Microbiology 2022Quote: ... we used R2/2 grids (Quantifoil) coated with a thin layer of 0.2 mg/ml graphene oxide ...
-
Cryo-electron tomography of eel sperm flagella reveals a molecular “minimum system” for motile ciliabioRxiv - Cell Biology 2023Quote: ... holey carbon grids (Quantifoil R2/2) were glow discharged for 30 seconds in a Pelco EasyGlow glow discharge unit ...
-
bioRxiv - Biochemistry 2023Quote: Quantifoil Cu200 R2/2 grids (Quantifoil) were pre-clipped and marked along the clip edge to determine the orientation in the future ...
-
bioRxiv - Microbiology 2022Quote: ... Quantifoil (R2/2, Quantifoil Micro Tools) Au-EM finder grids ...
-
bioRxiv - Biophysics 2021Quote: To provide extra support for cell growth 5-6 nm of carbon was evaporated onto Quantifoil Au 200 R2/1 or R2/2 grids (Quantifoil Micro Tools GmbH). Grids were then glow discharged and incubated in supplemented RPMI-1640 overnight in the cell incubator ...
-
bioRxiv - Biophysics 2020Quote: ... samples were stored on ice and applied to the cryo-grids (2 nm precoated Quantifoil R3/3 holey carbon supported grids) at a concentration of 10 μM and vitrified using a Vitrobot Mark IV (FEI) ...
-
bioRxiv - Microbiology 2020Quote: ... 3 μL of the sample mixture was applied to a freshly glow-discharged copper R2/2 200 grid (Quantifoil Micro Tools), pre-blotted for 30 seconds ...
-
bioRxiv - Biochemistry 2021Quote: ... applied to 300-mesh carbon coated (2nm thickness) holey carbon Quantifoil 2/2 grids (Quantifoil Micro Tools) and flash-frozen as described in (Khatter et al. ...
-
bioRxiv - Microbiology 2023Quote: ... the sample was loaded onto Quantifoil carbon coated grids (R 2/2; Quantifoil Micro Tools, Jena, Germany) and cryo-fixed by plunge freezing with a Leica GP (Leica Microsystems ...
-
bioRxiv - Biophysics 2023Quote: EM grids (UltrAuFoil R2/2 Au 200 mesh Q250AR2A and Quantifoil R2/2 Au 200 mesh Q2100AR2) were micropatterned using the Alveole PRIMO micropatterning system20–22 ...
-
bioRxiv - Molecular Biology 2021Quote: ... 3 μL aliquots of the cell suspension were applied to glow-discharged R2/2 200 mesh copper Quantifoil grids (Quantifoil Micro Tools), the sample was pre-blotted for 30 seconds ...
-
bioRxiv - Cell Biology 2022Quote: ... 3 µl of the microtubule sample was deposited at the surface of a glow-discharged holey carbon grid (Quantifoil R2/2, Cu200) in the temperature (35 °C ...
-
bioRxiv - Biophysics 2020Quote: Purified GABAAR was incubated with ~1 μM Megabody-2524 and 3.5 μl sample was applied to glow discharged 300 mesh 1.2/1.3 and 2/2 UltraAuFoil gold grids (Quantifoil) for 30 s then blotted for 5.5 s prior to plunge-freezing with liquid ethane cooled by liquid nitrogen ...
-
bioRxiv - Bioengineering 2022Quote: ... Holey carbon Quantifoil grids (2 µm diameter with an interspace of 2 µm, Quantifoil Micro Tools GmbH, Germany) were prepared by glow discharge (easyGlow® System ...
-
bioRxiv - Microbiology 2022Quote: ... using R2/2 200 mesh grids (Quantifoil) and imaged using a Talos 120 kV cryo-transmission electron microscope.
-
bioRxiv - Microbiology 2023Quote: R2/2 Cu 200 mesh grids (Quantifoil) were glow-discharged for 40 s at 2.7 mA ...
-
bioRxiv - Biochemistry 2023Quote: UltrAuFoil R2/2 Au200 mesh grids (Quantifoil) were glow discharged for 1 min on both sides at 25 mA using a Pelco easiGlow unit (Ted Pella ...
-
bioRxiv - Biochemistry 2024Quote: UltrAuFoil R2/2 Au300 mesh grids (Quantifoil) were glow discharged for 30 seconds on each side at 25 mA using a Pelco easiGlow unit (Ted Pella ...
-
bioRxiv - Cell Biology 2024Quote: ... or G200F1 R2/2 SiO2 grids (Quantifoil). The grids were glow discharged and coated with human fibronectin (FAL356008 ...
-
bioRxiv - Biochemistry 2024Quote: ... 3.5 μl diluted T33-549 (final concentration ∼0.9 mg/ml) was applied to the glow-discharged surface of grids (QUANTIFOIL® R 2/2 on Cu 300 mesh + 2 nm C), then immediately plunged into liquid ethane after blotting for 4s with a blot force of 0 ...
-
bioRxiv - Biophysics 2020Quote: ... 2 μL of a 1 in 6 dilution of the batch crystallisation was applied to the carbon side of glow discharged R2/2 Quantifoil™ grids (Quantifoil Micro Tools, Jena, Germany). Excess liquid was removed by blotting for 4-6 s with a Vitrobot (Thermo Fisher ...
-
bioRxiv - Biochemistry 2024Quote: ... or calpain-3-titin/I81-I83 (2mg/mL) from Superose 6 increase 10/300GL column chromatography was loaded onto glow-discharged holey carbon grids (Quantifoil 1.2/1.3 + 2 nm Carbon). The grids were blotted with filter paper for 2.5 secs at 22 °C and then immediately plunged into liquid ethane cooled by liquid nitrogen using a Vitrobot Mark IV (Thermo Fisher Scientific) ...
-
bioRxiv - Cell Biology 2023Quote: ... Two μl of the diluted complex were applied to freshly glow-discharged R 2/2 holey carbon grids (Quantifoil), which were blotted with a force of 6 for 5 seconds and immediately vitrified by plunge-freezing in liquid ethane using a Vitrobot Mark IV (ThermoFisher ...
-
bioRxiv - Cell Biology 2022Quote: Cells were trypsinized and seeded onto 200 mesh gold holey carbon grids (R2/2-2 C, Quantifoil Micro Tools) placed in 3D printed grid holders (51 ...
-
bioRxiv - Bioengineering 2023Quote: ... a 200-mesh copper grid covered with a Quantifoil R 2/2 holey carbon film (Quantifoil Micro Tools GmbH) was surface plasma treated for 40 seconds using a Cressington 208 carbon coater ...
-
bioRxiv - Cell Biology 2023Quote: ... three microliters of EV sample were directly placed onto a glow–discharged 2/2 copper grid (Quantifoil, Jena, Germany). The excess sample was removed with 595 filter paper (Schleicher & Schuell ...
-
bioRxiv - Biochemistry 2024Quote: ... a freshly glow-discharged Cu300 R2/2 holey carbon grid with a 2-nm layer of amorphous carbon (Quantifoil) was mounted in the chamber of a Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Immunology 2022Quote: ... detergent at a final concentration of 0.005 mM was added to each sample and 3 µl of that solution was immediately loaded onto plasma-cleaned QuantiFoil R 2/1 (400-mesh; Quantifoil Micro Tools GmbH) and UltrAuFoil R 1.2/1.3 grids (300-mesh ...
-
bioRxiv - Biochemistry 2020Quote: ... 3 μl aliquots of purified mitoribsomes was incubated for 30 s on glow-discharged holey carbon grids (Quantifoil R2/2, 300 mesh, copper) pre-coated with a home-made continuous carbon film with thickness of ~ 27 Å ...
-
bioRxiv - Immunology 2020Quote: ... and 3 µl was immediately loaded onto plasma cleaned Quantifoil R 2/1 holey carbon copper gri (Cu, 400-mesh, Quantifoil Micro Tools GmbH). Blotted grids were plunge-frozen into nitrogen-cooled liquid ethane.
-
bioRxiv - Molecular Biology 2022Quote: ... 2–3 μL of sample solution was applied to a holey carbon grid (Quantifoil R2/1, Mo 300 mesh; Quantifoil Micro Tools GmbH) covered with a thin amorphous carbon film at 4 °C with 100% humidity ...
-
bioRxiv - Biophysics 2024Quote: ... Cryo-EM grids were obtained by flash-freezing 3 µL of purified IPNV particles on glow-discharged holey carbon grids (Quantifoil R2/2, Cu 300 mesh; Quantifoil Micro Tools GmbH). The grids were plunge-frozen in liquid ethane after blotting for 3 s under 4°C ...