bioRxiv - Cell Biology 2022Quote: ... 3 μL of ∼100 nM (A260 4.0 or 6.0) mitoribosome sample was applied onto a glow-discharged (20 mA for 30 sec) holey-carbon grid (Quantifoil R2/1 copper, mesh 300) coated with continuous carbon (of ∼3 nm thickness ...
-
bioRxiv - Molecular Biology 2023Quote: Freshly purified ZorAB sample was concentrated to 2-3 mg/mL and 2.7 μL protein was applied onto the glow-discharged (30 s, 5 mA) grids (Quantifoil R0.6/1 300 mesh Au) and plunge-frozen into liquid ethane using a Vitrobot Mark IV (FEI ...
-
bioRxiv - Bioengineering 2024Quote: ... LCNP or EV suspensions in PBS (∼1 × 1012 particles/mL) were deposited on 300-mesh lacey carbon-coated copper grids (Quantifoil Micro Tools GmbH, Germany). The grids were previously glow-discharged for 45 s using an Emitech K100X glow discharge system (Quorum Technologies Ltd. ...
-
bioRxiv - Biophysics 2020Quote: Three microliters of the apoferritin samples with 1.5 mg/ml or 0.2 mg/ml were applied onto glow-discharged 200-mesh R2/1 Quantifoil grids (used for the K3 dataset) or 200-mesh R2/1 Quantifoil grids coated with continuous carbon film (Quantifoil, used for the Falcon4 dataset), respectively ...
-
bioRxiv - Biophysics 2022Quote: Cryo-EM grids were prepared by applying 3 μL of sample (at the native 1 nM concentration) on glow discharged holey gold grids (Quantifoil Cu 1.2/1.3 400 mesh). Excess sample was removed by blotting with filter paper for 4 sec prior to plunge-freezing in liquid ethane using a FEI Vitrobot Mark IV at 100% humidity and 4 °C ...
-
bioRxiv - Molecular Biology 2020Quote: Cryo-EM grids were prepared by applying 3 µL sample (at a protein concentration of 1 mg/ml) on glow-discharged holey gold grids (Quantifoil Au 1.2/1.3 300 mesh). Excess sample was removed by blotting with filter paper for 2-3 s before plunge-freezing in liquid ethane (cooled to −181 °C ...
-
bioRxiv - Biophysics 2024Quote: ... to produce a fiducial marker along with 0.01% NP-40 and 10 μM tubulin solution with BRB80 buffer and 1 mM GTP before the solution was dropped onto the grids (QUANTIFOIL R 1.2/1.3 Cu 200). The grids were blotted with vitrobot (Thermo Fisher Scientific ...
-
bioRxiv - Cell Biology 2024Quote: Vitrified grids were prepared by applying 3 µl of 1 uM complex sample to a freshly glow- discharged holey carbon grids (Quantifoil R1.2/1.3 Au 200 mesh). The sample was blotted for 3-5 s at 4 ℃ with 100% humidity and plunged-frozen in liquid nitrogen cooled ethane (FEI TM ...
-
bioRxiv - Immunology 2023Quote: ... respectively) and 3 μl were kept 5 min at RT until their application onto glow-discharged holey carbon grids (Quantifoil, Au 300 mesh, R 0.6/1). The grids were blotted and then plunged into liquid ethane using a FEI Vitrobot Mark IV at 20°C and 95% relative humidity ...
-
bioRxiv - Microbiology 2024Quote: ... 3.5 μL of protein sample at 0.15 mg/mL for the Gal/GalNAc lectin and at 0.2 mg/mL for lectin:scFv complexes were applied onto glow-discharged grids (Quantifoil R2/1 carbon film on a 300 gold mesh). After incubation for 10 s ...