Labshake search
Citations for Quantifoil Micro Tools :
451 - 500 of 550 citations for 7 Chloro 3 nitro 3 4 dihydro 1H quinolin 2 one since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biochemistry 2019Quote: ... 2 μl 60 μM H6-TtBac in Buffer C were added onto freshly glow-discharged Quantifoil Cu/Rh R2/2 holey carbon 200 mesh grids (Quantifoil). The grids were blotted for 2.5 s with a blotting force of −15 ...
-
bioRxiv - Microbiology 2019Quote: ... 3.5 μL of unstained nanoparticles were applied to glow discharged 200 mesh R2/2 Quantifoil Cu grids (Quantifoil, Großlöbichau, Germany) and plunge frozen using a Vitrobot Mark IV plunger (FEI ...
-
bioRxiv - Biochemistry 2021Quote: ... 3 µL of the concentrated RdRp-RNA complex were mixed with 0.5 µl of octyl ß-D-glucopyranoside (0.003% final concentration) and applied to freshly glow discharged R 2/1 holey carbon grids (Quantifoil). The grids were blotted for 7 seconds with blot force 5 using a Vitrobot MarkIV (Thermo Fischer Scientific ...
-
bioRxiv - Biochemistry 2022Quote: ... 3.0 μL of sample was applied to glow-discharged 200-mesh copper 2 nm C R1.2/1.3 cryo-EM grids (Quantifoil Micro Tools), blotted 1 s at 100 % humidity ...
-
bioRxiv - Biochemistry 2022Quote: ... 2.5 μL of sample was applied to glow-discharged 200-mesh copper 2 nm C R1.2/1.3 cryo-EM grids (Quantifoil Micro Tools), blotted 3 s at 75 % humidity ...
-
bioRxiv - Biophysics 2020Quote: ... 3 μL of the concentrated RdRp-RNA complex were mixed with 0.5 μl of octyl ß-D-glucopyranoside (0.003% final concentration) and applied to freshly glow discharged R 2/1 holey carbon grids (Quantifoil). Prior to flash freezing in liquid ethane ...
-
bioRxiv - Cell Biology 2022Quote: Cells were applied onto galectin-8 coated EM grids with carbon support film (R2/2, Au mesh; Quantifoil, Jena, Germany). After 15-20 min incubation ...
-
bioRxiv - Biophysics 2019Quote: Three microliters of isolated pilus suspension were pipetted onto a glow-discharged R2/2 Cu 300 mesh holey carbon-coated grids (Quantifoil). Grids were plunge frozen in liquid ethane after blotting using a Vitrobot Mark IV (Thermo Fisher ...
-
bioRxiv - Microbiology 2019Quote: ... Fixed Brucella cells were vitrified on glow-discharged 200 mesh copper EM-grids with extra thick R2/2 holey carbon film (Quantifoil). Per grid ...
-
bioRxiv - Cell Biology 2021Quote: HeLa Doxycycline-inducible stable cell lines were grown for approximately 48 h on holey carbon gold EM grids (200 mesh, R2/2, Quantifoil) prior to plunge freezing ...
-
bioRxiv - Molecular Biology 2020Quote: ... a 2.2-µL aliquot of this sample was applied to a plasma cleaned holey carbon grid (R2/1, 200 mesh; Quantifoil) or Graphene Oxide-Lacey Carbon grid (300 mesh ...
-
bioRxiv - Microbiology 2020Quote: ... 3,5 μl of the culture was mixed with 10 nm gold fiducial markers (Cell Microscopy Core, UMC Utrecht) and applied onto glow-discharged R2/2 200 mesh holey carbon EM grids (Quantifoil). The grid was then rapidly plunged in liquid ethane using the Leica GP automated freeze-plunger ...
-
bioRxiv - Synthetic Biology 2019Quote: ... 4μL of PEG-precipitation purified DNA origami were applied on glow-discharged Quantifoil R2/2 copper grids (Quantifoil Micro Tools) and plunge frozen in liquid ethane cooled liquid nitrogen using a Lecia EM GP device (Leica Microsystem) ...
-
bioRxiv - Evolutionary Biology 2020Quote: ... was applied onto a glow-discharged (20 mA for 30 seconds) holey-carbon grid (Quantifoil R2/2, copper, mesh 300) coated with continuous carbon (of ~3 nm thickness ...
-
bioRxiv - Biochemistry 2021Quote: ... 3.5 μL sample was applied onto a freshly glow-discharged 200-mesh copper 2 nm C R1.2/1.3 grids (Quantifoil Micro Tools). The grids were blotted for 1 s and plunge-vitrified in liquid ethane ...
-
bioRxiv - Biophysics 2020Quote: ... Mycoplasma pneumoniae strain M129(ATCC 29342)cells were grown on 200 mesh gold grids coated with a holey carbon support (R 2/1, Quantifoil). Cells were cultivated at 37 °C in modified Hayflick medium ...
-
bioRxiv - Biochemistry 2022Quote: ... 2–2.5 µl of protein solution was applied to glow-discharged holey carbon grids (Quantifoil R1.2/1.3 Au 200 mesh). The endogenous samples were applied onto grids containing an additional thin layer of continuous carbon support (Quantifoil R1.2/1.3 Cu 200 mesh + 2 nm C ...
-
bioRxiv - Microbiology 2022Quote: ... and 4 µl of the mixture was applied to a glow-discharged holey-carbon copper EM grid (R2/1 or R2/2, Quantifoil). The grid was automatically blotted from the backside for 4-6 s in a Mark IV Vitrobot by using a Teflon sheet on the front pad ...
-
bioRxiv - Microbiology 2022Quote: ... mixed with 10 nm protein A-coated colloidal gold (Aurion) and applied onto a glow-discharged EM grid (200 mesh, R 2/1, Quantifoil) prior to plunge-freezing with a Leica EM GP2 automatic plunge-freezer.
-
bioRxiv - Cell Biology 2023Quote: Cells were blotted on EM grids (R 2/1 holey carbon 200 films on Cu 200 mesh, Quantifoil Micro Tools). The grids were first glow-discharged and 4 µl of trypanosome wild-type culture (2-4 · 107 cells/ml ...
-
bioRxiv - Microbiology 2023Quote: ... and 4 µl of the mixture was applied to a glow-discharged holey-carbon copper EM grid (R2/1 or R2/2, Quantifoil). The grid was automatically backside blotted for 4-6s in a Mark IV Vitrobot (Thermo Fischer Scientific ...
-
bioRxiv - Molecular Biology 2023Quote: ... Samples for cryo-ET were deposited onto 300-mesh holey carbon grids (Quantifoil Micro Tools, R2/2 X-103-Cu300) and samples for cryo-SPA were deposited onto 200-mesh holey carbon grids (Quantifoil Micro Tools ...
-
bioRxiv - Biophysics 2023Quote: A 3 µL aliquot of purified CDTbD623A/D734Aprotein sample at a concentration of 30 µM was applied to a glow discharged QUANTIFOIL® copper R 1.2/1.3 grid with a 2 nm thin extra carbon layer (QUANTIFOIL, GMBH). For calcium depleted CDTb (28 µM) ...
-
bioRxiv - Biophysics 2023Quote: ... 3 or 3.5 μl of LRRK2RCKW:inhibitor:E11 DARPin complex were applied to a glow-discharged UltraAuFoil Holey Gold 200 mesh R2/2 grid (Quantifoil, Catalog # Q250AR2A) and incubated in a FEI Vitrobot IV chamber at 4°C and 95% humidity for 20 sec ...
-
bioRxiv - Biochemistry 2023Quote: 2.4 µL of sample were applied to a freshly glow discharged 200-mesh Cu + 2 nm C R1.2/1.3 grid (Quantifoil Micro Tools), blotted for 6 s at 100% humidity ...
-
bioRxiv - Cell Biology 2024Quote: ... 4 × 104 MDM cells were seeded on glow discharged and UV-light sterilized holey carbon grids (R2/2, Au, 200 mesh, Quantifoil), which were placed in a glass-bottomed ‘microwell’ of 35-mm MatTek dish (MatTek ...
-
bioRxiv - Biochemistry 2024Quote: ... using 3 µL of the samples applied to previously glow discharged R 2/1 Holey Carbon Cu 200 mesh EM grids (Quantifoil). Samples were 10 µM FtsZ with or without ZapD or mZapD at different concentrations specified in each case (0 – 60 µM) ...
-
bioRxiv - Biophysics 2019Quote: An aliquot of 4 μl of 6 μM Ac-E46K α-syn fibril solution was applied to a glow-discharged holey carbon grid (Quantifoil R1.2/1.3, 300 mesh), blotted for 6.5 s ...
-
bioRxiv - Biophysics 2020Quote: ... An aliquot of 4 μl pY39 α-syn fibril solution was applied to a glow-discharged carbon electron microscope grid (Quantifoil R1.2/1.3, 300 mesh). After 10 s of incubation ...
-
bioRxiv - Molecular Biology 2021Quote: The purified GIP1-42–GIPR–Gs–Nb35 complex at a concentration of 6-7 mg/mL was mixed with 100 μM GIP1-42 at 4 C and applied to glow-discharged holey carbon grids (Quantifoil R1.2/1.3, Au 300 mesh) that were subsequently vitrified by plunging into liquid ethane using a Vitrobot Mark IV (ThermoFisher Scientific) ...
-
bioRxiv - Molecular Biology 2021Quote: The purified tirzepatide–GIPR–Gs–Nb35 complex at a concentration of 18-20 mg/mL was mixed with 100 μM tirzepatide at 4°C and applied to glow-discharged holey carbon grids (Quantifoil R1.2/1.3, Au 300 mesh) that were subsequently vitrified by plunging into liquid ethane using a Vitrobot Mark IV (ThermoFisher Scientific) ...
-
bioRxiv - Molecular Biology 2021Quote: The purified non-acylated tirzepatide–GIPR–mini-Gs–Nb35 complex at a concentration of 14-16 mg/mL was mixed with 100 μM non-acylated tirzepatide at 4°C and applied to glow-discharged holey carbon grids (Quantifoil R1.2/1.3, Au 300 mesh) that were subsequently vitrified by plunging into liquid ethane using a Vitrobot Mark IV (ThermoFisher Scientific) ...
-
bioRxiv - Molecular Biology 2021Quote: The purified peptide 20–GIPR–Gs–Nb35 complex at a concentration of 5-6 mg/mL was mixed with 100 μM peptide 20 at 4°C and applied to glow-discharged holey carbon grids (Quantifoil R1.2/1.3, Au 300 mesh) that were subsequently vitrified by plunging into liquid ethane using a Vitrobot Mark IV (ThermoFisher Scientific) ...
-
bioRxiv - Molecular Biology 2021Quote: The purified peptide 20–GCGR–Gs–Nb35 complex at a concentration of 12-14 mg/mL was mixed with 100 μM peptide 20 at 4°C and applied to glow-discharged holey carbon grids (Quantifoil R1.2/1.3, Au 300 mesh) that were subsequently vitrified by plunging into liquid ethane using a Vitrobot Mark IV (ThermoFisher Scientific) ...
-
bioRxiv - Biochemistry 2023Quote: ... Four microliters of purified Cx36 proteins (4-6 mg/ml) were applied onto a negatively glow-discharged holey carbon grid (Quantifoil R1.2/1.3 Cu 300 mesh). For samples involving Cx36-WT ...
-
bioRxiv - Microbiology 2019Quote: ... The EM-grids were glow-discharged 200 mesh copper grids with an extra thick R2/2 carbon film (Quantifoil Micro Tools). 3,5 µl of the sample was applied to the EM grid and blotted at a temperature of 16°C and a humidity between 95-99% ...
-
bioRxiv - Biophysics 2019Quote: ... The Netherlands) as fiducial markers and glow-discharged R2/2 Cu 300 mesh holey carbon-coated support grids (Quantifoil, Jena, Germany) were dipped into the solution ...
-
bioRxiv - Plant Biology 2021Quote: ... 3 µl of suspended cells in culture medium were applied to the front side of glow-discharged R2/2 carbon-coated copper grids (Quantifoil MicroTools), with additional 1 µL cells added to the back side ...
-
bioRxiv - Biochemistry 2021Quote: ... Three microliters of the protein solution were applied on a glow-discharged holey carbon grids (200 mesh Quantifoil R2/2 molybdenum), which had been treated with H2 and O2 mixtures in a Solarus plasma cleaner (Gatan ...
-
bioRxiv - Cell Biology 2022Quote: ... The IL-11Δ10/IL-11RαD1-D3/gp130D1-D3 complex (0.5 mg/mL) was blotted onto UltrAuFoil grids (R2/2, Quantifoil Micro Tools GmbH) that had been subjected to glow discharge (15 mA for 30 s) ...
-
bioRxiv - Microbiology 2023Quote: ... sample were placed onto glow-discharged Quantifoil R2/1 Cu300 holey carbon grids (1 µm spacing, 2 µm holes, copper mesh) (Quantifoil, Germany), blotted for 3.5 s before flash-freezing in liquid ethane using a Vitrobot mark IV (FEI ...
-
bioRxiv - Biophysics 2023Quote: ... 3 to 3.5 μl of complex was applied to a glow-discharged UltrAuFoil Holey Gold 200 mesh R2/2 grid (Quantifoil, Catalog # Q250AR2A) and incubated in a FEI Vitrobot IV chamber at 4°C and 95% humidity for 20 sec ...
-
bioRxiv - Biophysics 2020Quote: ... The WT and Y222F MTs were applied to lacey carbon grids (Agar Scientific AGS166-4 400 mesh copper grids) and holey carbon grids (Quantifoil R1.2/1.3 300 mesh copper grids) immediately after application of glow discharge to the grids ...
-
bioRxiv - Synthetic Biology 2021Quote: ... 25 mM Tris at pH 8.0 to a concentration of 2 mg/mL to a glow-discharged (1 min at 5 mA) holey carbon grid (Quantifoil Q225-CR1.3). This was followed by plunge-freezing in liquid ethane using an FEI Vitribot Mark IV (100% humidity ...
-
bioRxiv - Biophysics 2021Quote: 3 μl of the human sperm sample were applied to glow discharged copper R2/2 200-mesh holey carbon grid (Quantifoil Micro Tools) and plunge frozen in liquid ethane using an automatic plunge freezer (Vitrobot ...
-
bioRxiv - Cell Biology 2020Quote: ... Cells were incubated at 37°C and 5% CO2 for 16h prior to trypsinization and seeding onto 200 mesh gold holey carbon grids (R2/2-2C; Quantifoil Micro Tools), which were placed in 3D printed grid holders [39] ...
-
bioRxiv - Molecular Biology 2021Quote: ... After another 3 min at 37 °C the termination complexes were placed on ice for 15 min and subsequently applied to Quantifoil R2/2 holey carbon grids (Quantifoil Micro Tools) either coated with a thin continuous carbon film or with graphene oxide flakes (Sigma-Aldrich) ...
-
bioRxiv - Biophysics 2019Quote: 3.5 μl of sample of fragmented doublets (~4 mg/ml) or the Sarkosyl A-tubule (~500 μg/ml) was applied to a glow-discharged holey carbon grid (Quantifoil R2/2), blotted and plunged into liquid ethane using Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Cell Biology 2021Quote: ... 4 µl of the solution was applied to a glow-discharged (30s at 35 mA) copper R2/2 holey carbon grid (Quantifoil Micro Tools). After removing excess liquid by blotting the grid from the back side with Whatman filter paper for 2 s ...
-
bioRxiv - Cell Biology 2020Quote: ... Samples were applied to freshly glow-discharged (Edwards S150B, 45 sec, 30-50 mA, 1,2kV, 10-2 mbar) copper holey carbon grids (Quantifoil, Cu-R1.2/1.3) under 100% humidity ...