bioRxiv - Immunology 2024Quote: ... packed in-house with ReproSil-Pur 120 C18-AQ 1.9 µm resin (Dr. Maisch HPLC GmbH), and eluted over a 150-min linear gradient of 5 to 30% buffer B (80% acetonitrile ...
-
bioRxiv - Cell Biology 2024Quote: ... Peptides were first loaded on a trapping column and subsequently separated inline on a 15 cm C18 column (75 μm x 15 cm, ReproSil-Pur R13aq 3 μm 120 Å C18-AQ, Dr. Maisch HPLC GmbH, Ammerbuch-Entringen, Germany). The mobile phase consisted of water with 0.1% formic acid (solvent A ...
-
bioRxiv - Systems Biology 2024Quote: ... Peptides were loaded onto a tip column (75 μm diameter, 150 mm length) packed with reverse phase beads (3 μm/120 Å ReproSil-Pur C18 resin, Dr. Maisch HPLC GmbH). A 60 min gradient of 5 to 35% (v/v ...
-
bioRxiv - Biochemistry 2024Quote: ... and separated on a 75 μm 250 mm C18 column (Reprosil-Pur 120 C18-AQ, 1.9 μm, Dr. Maisch HPLC GmbH). The nano-LC method consisted of a 60 min multi-linear gradient at a flow rate of 300 nl/min ...
-
bioRxiv - Cell Biology 2024Quote: ... Peptides were first loaded on a trapping column and subsequently separated inline on a 15 cm C18 column (75 µm x 15 cm, ReproSilPur 3 µm 120 Å C18-AQ, Dr. Maisch HPLC GmbH, Ammerbuch-Entringen, Germany). The mobile phase consisted of water with 0.1% formic acid (solvent A ...
-
bioRxiv - Immunology 2024Quote: ... Peptides were first loaded on a trapping column and subsequently separated inline on a 15 cm C18 column (75 μm x 15 cm, ReproSil-Pur 3 μm 120 Å C18-AQ, Dr. Maisch HPLC GmbH, Ammerbuch-Entringen, Germany). The mobile phase consisted of water with 0.1% formic acid (solvent A ...
-
bioRxiv - Neuroscience 2024Quote: ... packed manually (23 cm) with ReproSil-Pur 120 ODS-3 (C18; particle size 3 µm; Dr. Maisch HPLC, Germany) from which eluting peptides were directly electrosprayed (2.3 kV ...
-
bioRxiv - Cancer Biology 2024Quote: ... The packing material for the both columns was ReproSil-Pur 5 μm 200 Å C18-AQ (Dr. Maisch HPLC GmbH, Ammerbuch, Germany).
-
bioRxiv - Biochemistry 2024Quote: ... the precolumn was switched online with a laboratory-made 50 cm × 75 μm internal diameter separation column packed with ReproSil-Pur C18-AQ 3-μm resin (Dr. Maisch HPLC) and the peptides were eluted with a linear gradient of 5–40% solvent B (A ...
-
bioRxiv - Biochemistry 2024Quote: ... the pre-column was switched online with a self-made 50 cm × 75 μm internal diameter separation column packed with ReproSil-Pur C18-AQ 3-μm resin (Dr. Maisch HPLC), and the peptides were eluted with a linear gradient from 5–40% solvent B (A ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... the trap column was switched in-line with a 75 µm inner diameter (ID) x 400 mm analytical column (packed in-house with ReproSil-Pur 120 C18-AQ, 3 µm particle size, Dr. Maisch HPLC GmbH). Mobile phase A consisted of 0.4% formic acid in water ...
-
Cancer-associated fibroblasts produce matrix-bound vesicles that influence endothelial cell functionbioRxiv - Cancer Biology 2023Quote: ... 1.9μm resin (Dr. Maisch HPLC GmbH). The emitter was kept at 50°C (trans-SILAC ...
-
bioRxiv - Immunology 2023Quote: ... Peptides were first loaded on a trapping column and subsequently separated inline on a 15 cm C18 column (75 μm x 15 cm, ReproSil-Pur 3 μm 120 Å C18-AQ, Dr. Maisch HPLC GmbH, Ammerbuch-Entringen, Germany). The mobile phases consisted of water with 0.1% HCOOH (solvent A ...
-
bioRxiv - Neuroscience 2023Quote: ... Peptides were first loaded on a trapping column and subsequently separated inline on a 15 cm C18 column (75 μm x 15 cm, ReproSilPur 3 μm 120 Å C18-AQ, Dr. Maisch HPLC GmbH, Ammerbuch-Entringen, Germany). The mobile phase consisted of water with 0.1% formic acid (solvent A ...
-
bioRxiv - Molecular Biology 2023Quote: ... The peptides were first loaded on a trapping column and subsequently separated inline on a 15-cm C18 column (75 µm x 15 cm, ReproSil-Pur 5 µm 200 Å C18-AQ, Dr. Maisch HPLC GmbH). The mobile phase consisted of 0.1% formic acid (solvent A ...
-
bioRxiv - Microbiology 2023Quote: ... Peptides were reconstituted in 3% ACN/5% FA prior to loading onto an analytical column (35 cm, 1.9 µm C18 (Dr. Maisch HPLC GmbH), packed in-house PicoFrit 75 µm inner diameter ...
-
bioRxiv - Plant Biology 2023Quote: ... Peptides were first loaded onto a trapping column and subsequently separated on a 15 cm C18 column (75 μm × 15 cm, ReproSil-Pur 5 μm 200 Å C18-AQ, Dr. Maisch HPLC GmbH, Ammerbuch-Entringen, Germany). The mobile phase consisted of water with 0.1% formic acid (solvent A ...
-
bioRxiv - Systems Biology 2023Quote: ... packed with 1.9 µM C18 ReproSil Pur AQ particles (Dr. Maisch HPLC GmbH, Ammerbuch, DEU) with a Dionex U3000 HPLC (Thermo Fisher Scientific) ...
-
bioRxiv - Cell Biology 2023Quote: ... Peptides were first loaded on a trapping column and subsequently separated inline on a 15 cm C18 column (75 µm × 15 cm, ReproSil-Pur 5 µm 200 Å C18-AQ, Dr. Maisch HPLC GmbH, Ammerbuch-Entringen, Germany). The mobile phase consisted of water with 0.1% formic acid (solvent A ...
-
bioRxiv - Cell Biology 2023Quote: ... capillary columns were pulled with a laser puller and packed in-house with 10–12 cm C18 (Reprosil-Pur 120 C18-AQ, 3 μm, Dr. Maisch HPLC GmbH) in methanol ...
-
Linear ubiquitination at damaged lysosomes induces local NF-κB activation and controls cell survivalbioRxiv - Cell Biology 2023Quote: Samples were loaded onto 75 µm x 15 cm fused silica capillaries (custom-made) packed with C18AQ resin (Reprosil-Pur 120, 1.9 µm, Dr. Maisch HPLC) using an Easy-nLC1200 liquid chromatography ...
-
Cancer-associated fibroblasts produce matrix-bound vesicles that influence endothelial cell functionbioRxiv - Cancer Biology 2023Quote: ... peptides were loaded on pipette-tip columns of ReproSil-Pur 120 C18-AQ 5 μm (Dr. Maisch HPLC GmbH, Ammerbuch, Germany), eluted in 7 fractions using an increasing amount of acetonitrile and analyzed by MS.
-
bioRxiv - Bioengineering 2022Quote: ... For the chromatographic separation 30 cm long capillary (75 μm inner diameter) was packed with 1.9 μm C18 beads (Reprosil-AQ, Dr. Maisch HPLC). On one end of the capillary nanospray tip was generated using a laser puller ...
-
bioRxiv - Neuroscience 2022Quote: ... Peptides were first loaded on a trapping column and subsequently separated in-line on a 15 cm C18 column (75 μm ID x 15 cm, ReproSil-Pur 5 μm 200 Å C18-AQ, Dr. Maisch HPLC GmbH, Ammerbuch-Entringen, Germany). PRM scans were acquired at 17500 at 400 m/z resolution with a mass lock option m/z 445.120025 ...
-
bioRxiv - Cancer Biology 2022Quote: ... Peptides were reconstituted in 3% ACN/5% FA prior to loading onto an analytical column (35 cm, 1.9µm C18 (Dr. Maisch HPLC GmbH), packed in-house PicoFrit 75 µm inner diameter ...
-
bioRxiv - Cancer Biology 2022Quote: ... Peptides were first loaded on a trapping column and subsequently separated inline on a 15 cm C18 column (75 μm x 15 cm, ReproSil-Pur 5 μm 200 Å C18-AQ, Dr. Maisch HPLC GmbH, Ammerbuch-Entringen, Germany). The mobile phase consisted of water with 0.1% formic acid (solvent A ...
-
bioRxiv - Cancer Biology 2022Quote: ... Peptides were then transferred to an in-house packed C18 analytical column (ReproSil®-Pur from Dr. Maisch HPLC GmbH ...
-
bioRxiv - Molecular Biology 2022Quote: ... Peptides were first loaded on a trapping column and subsequently separated inline on a 15 cm C18 column (75 μm x 15 cm, ReproSil-Pur 3 μm 120 Å C18-AQ, Dr. Maisch HPLC GmbH, Ammerbuch-Entringen, Germany). The mobile phase consisted of water with 0.1% formic acid (solvent A ...
-
bioRxiv - Cancer Biology 2022Quote: ... 75-μm inner diameter column in house packed with ReproSil-Pur C18-AQ 1.9□μm resin (Dr. Maisch HPLC GmbH) and separated over a 270-min gradient of 2–60% buffer B (80% acetonitrile ...
-
bioRxiv - Cell Biology 2022Quote: ... A home-made C18 column was used for peptide separation and consisted of a 30 cm nano-HPLC capillary column (75 μm inner diameter) filled with 1.9 μm Reprosil-Pur Basic C18-HD resin (Dr. Maisch HPLC GmbH) that terminated with a silica PicoTip® emitter tip (New Objective) ...
-
bioRxiv - Cancer Biology 2022Quote: ... in-house packed with ReproSil-Pur C18-AQ 1.9 µm resin (Dr. Maisch HPLC GmbH), and eluted during a 95 min linear gradient of 5-30% buffer B (80% ACN ...
-
bioRxiv - Microbiology 2022Quote: ... and separated in an in-house-packed analytical column (75 μm x 30 cm, particle size 3 μm, Reprosil-Pur C18, Dr. Maisch HPLC, Ammerbuch, Germany), using a linear gradient of solvent B (80% acetonitrile ...
-
bioRxiv - Biochemistry 2021Quote: ... Peptides were loaded onto an analytical column (25-30cm, 1.9um C18 (Dr. Maisch HPLC GmbH), packed in-house PicoFrit 75 μm inner diameter ...
-
bioRxiv - Neuroscience 2021Quote: ... and separated on a 75µm 250mm C18 column (Reprosil-Pur 120 C18-AQ, 1.9 µm, Dr. Maisch HPLC GmbH). The nano-LC method consisted of a 240min multi-linear gradient at a flow rate of 300nl/min ...
-
bioRxiv - Biochemistry 2021Quote: ... manually packed 11 cm (AP-MS) or 23 cm (csBN-MS) with ReproSil-Pur 120 ODS-3 (C18; particle size 3 µm; Dr. Maisch HPLC, Germany) and electrosprayed (2.3 kV ...
-
bioRxiv - Plant Biology 2021Quote: ... Peptides were first loaded onto a trapping column and subsequently separated on a 15 cm C18 column (75 μm × 15 cm, ReproSil-Pur 5 μm 200 Å C18-AQ, Dr. Maisch HPLC GmbH, Ammerbuch-Entringen, Germany). The mobile phase consisted of water with 0.1% formic acid (solvent A ...
-
bioRxiv - Plant Biology 2021Quote: ... Peptides were first loaded on a trapping column and subsequently separated inline on a 15-cm C18 column (75 μm × 15 cm, ReproSil-Pur 5 μm 200 Å C18-AQ, Dr. Maisch HPLC). The mobile phase consisted of water with 0.1% (v/v ...
-
bioRxiv - Cell Biology 2020Quote: ... packed with C18AQ resin (Reprosil-Pur 120, 1.9 µm, Dr. Maisch HPLC). Peptide mixtures were separated using a gradient of 5%–33% acetonitrile in 0.1% acetic acid over 75 min and detected on an Q Exactive HF mass spectrometer (Thermo Scientific) ...
-
bioRxiv - Neuroscience 2020Quote: ... which were packed with ReproSil-Pur 5 μm 200 Å C18-AQ (Dr. Maisch HPLC GmbH, Ammerbuch-Entringen, Germany). Mobile phase A consisted of 0.1% FA ...
-
bioRxiv - Developmental Biology 2020Quote: ... the analytical column (20 cm long) was packed in house with C18 beads (Dr. Maisch HPLC, Germany, 0.3 μm) with a flow rate of 0.3 μL/min ...
-
bioRxiv - Biochemistry 2020Quote: ... packed with 1.9 μm ReproSil-Pur 120 C18-AQ media (Dr. Maisch HPLC GmbH) using an EASY-nLC 1200 (Thermo Fisher Scientific) ...
-
bioRxiv - Systems Biology 2020Quote: ... The column was packed with ∼15 cm of C18 resin (Reprosil-Pur, 3 μm, Dr. Maisch HPLC GmbH, Germany). Lyophilized samples were resuspended in 5% formic acid and 1/4th of sample was used per injection for DDA and 1/4th for DIA ...
-
bioRxiv - Systems Biology 2020Quote: ... the pre-column was switch online with a self-made 50 cm x 75 um internal diameter separation column packed with ReproSil-Pur C18-AQ 3-μm resin (Dr. Maisch HPLC) and the peptides were eluted with a linear gradient from 5-40% solvent B (A ...
-
bioRxiv - Cell Biology 2020Quote: ... 1 μL of sample was separated over a 25 cm column packed with 1.9 μm Reprosil C18 particles (Dr. Maisch HPLC GmbH) by a nanoElute HPLC (Bruker) ...
-
bioRxiv - Cell Biology 2020Quote: ... both packed with 5 μm ReproSil-Pur 200 Å C18 silica particles (Dr. Maisch HPLC GmbH). The peptides were separated using a 60 min gradient (5-42 % B in 50min ...
-
bioRxiv - Molecular Biology 2020Quote: ... at 10 μl/min flow rate and separated on a 50 cm × 100 μm analytical column home-packed (53) with Reprosil Pur C18 AQ 1.9 μm sorbent (Dr. Maisch HPLC GmbH, Germany) in 360 μm OD 100 μm ID polyimide coated fused-silica capillary with a laser-pulled emitter prepared on P2000 laser puller (Sutter ...
-
bioRxiv - Molecular Biology 2020Quote: ... the pre-column was switched online with a self-made 50 cm x 75μm internal diameter separation column packed with ReproSil-Pur C18-AQ 3 μm resin (Dr. Maisch HPLC GmbH, Ammerbuch-Entringen, Germany) and the peptides were eluted with a linear gradient from 5-40% solvent B (A ...
-
bioRxiv - Immunology 2020Quote: ... Peptides were reconstituted in 3% ACN/5%FA prior to loading onto an analytical column (25-30cm, 1.9um C18 (Dr. Maisch HPLC GmbH), packed in-house PicoFrit 75 μm inner diameter ...