Citations for Active Motif :
1 - 27 of 27 citations for Sonicator since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Cell Biology 2020Quote: ... After sonication with an EpiShear probe sonicator (Active Motif) to obtain chromatin fragments less than 800 bp ...
-
bioRxiv - Molecular Biology 2020Quote: ... The nuclei were sonicated using EpiShear Probe Sonicator (Active Motif) for 15 seconds at 30% amplitude ...
-
bioRxiv - Cancer Biology 2020Quote: ... Chromatin was sonicated using an Epishear Probe Sonicator (Active Motif) for 4 min at 40% power ...
-
bioRxiv - Cancer Biology 2022Quote: ... Chromatin was sonicated using an Epishear Probe Sonicator (Active Motif) for 4 minutes (cycles of 30 seconds with 30 seconds of rest in between ...
-
bioRxiv - Cell Biology 2022Quote: ... the following settings on the EpiShear probe sonicator (Active Motif) were used ...
-
bioRxiv - Cancer Biology 2021Quote: ... Sonication was performed on an Epishear probe-in sonicator (Active Motif) at 50% amplitude for 15 cycles of 10 seconds ...
-
bioRxiv - Molecular Biology 2022Quote: ... Chromatin fragmentation was done with the Epishear probe sonicator (Active Motif) at 4 °C with 30 s long on and off cycles and 50 % amplitude ...
-
bioRxiv - Cancer Biology 2023Quote: ... which was then sonicated using an EpiShearTM Probe Sonicator (Active Motif), with 18 bursts at 30% amplitude for 30 sec per burst ...
-
bioRxiv - Genomics 2021Quote: ... the chromatin was sonicated with the Epishear™ Probe Sonicator (Active Motif) with 20 s ON and 30 s OFF for 8 cycles ...
-
bioRxiv - Genomics 2021Quote: ... Chromatin was sonicated for 3 minutes with a probe sonicator (Active Motif). Finally ...
-
bioRxiv - Developmental Biology 2023Quote: ... Crosslinked chromatin was sonicated using an EpiShear probe-in sonicator (Active Motif) with three cycles of 30 sec at an amplitude of 40% with 30 seconds rest between cycles ...
-
bioRxiv - Genomics 2024Quote: ... Crosslinked chromatin was sonicated using an EpiShear probe-in sonicator (Active Motif) with three cycles of 30 seconds at an amplitude of 40% with 30 seconds rest between cycles ...
-
bioRxiv - Molecular Biology 2023Quote: ... 0.2 mM dithiothreitol (DTT)) and sonicated for cell lysis (Q120 Sonicator, Active Motif). After centrifugation for 1 h at 4 °C and 45,850 g ...
-
bioRxiv - Genetics 2023Quote: ... The resuspended pellet was then sonicated using an EpiShear probe sonicator (Active Motif) for 2×13 minutes at 80% power (30 sec on ...
-
bioRxiv - Molecular Biology 2023Quote: ... and chromatin was sonicated using on EpiShear Porbe Sonicator (Active Motif, Carlsbad, CA, USA). Sheared chromatin was incubated overnight with 100µL Protein G Dynabeads (Thermo Fisher Scientific ...
-
bioRxiv - Cell Biology 2024Quote: ... 0.1 M TEAB and lysed by sonication using a PIXUL Multi-Sample Sonicator (Active Motif) with Pulse set to 50 ...
-
bioRxiv - Systems Biology 2023Quote: ... Nuclei were isolated and sheared using an ultrasonicator (Epishear probe sonicator, Active Motif, Carlsbad, CA, USA). The sheared chromatin was incubated with RELA antibody (Abcam ...
-
bioRxiv - Immunology 2023Quote: ... The chromatin in sonication buffer was sheared to 200-400bp by sonication using an EpiShear Probe Sonicator (Active Motif) at 30% amplitude ...
-
bioRxiv - Bioengineering 2024Quote: ... Genomic DNA was fragmented to a mean length of 300–1500 bp using the Epishear probe sonicator (Active Motif) and was controlled on 1.5% agarose gel ...
-
bioRxiv - Genetics 2020Quote: ... Chromatin was then sonicated for 15 cycles (20s on 30s off, 25% amplitude) using an EpiShear probe sonicator (Active Motif). After sonication ...
-
bioRxiv - Plant Biology 2021Quote: ... 30 ml cell suspension were sonicated for 5 min (5s on/10s off, 60% amplitude) with a sonicator (EpiShear, Active Motif) equipped with a ¼” microtip probe ...
-
bioRxiv - Genetics 2021Quote: ... quenched by 0.125M glycine for 5 min at RT and chromatin was then sheared by 5 min sonication (25% amplitude, 30sec off and 30 sec on) using a probe sonicator (Epishear, Active Motif). Immunoprecipitation was performed with Protein G Dynabeads (Life Technologies) ...
-
bioRxiv - Molecular Biology 2021Quote: ... the pellet resuspended in 147 μL of 2x SDS loading dye and DNA was sheared by sonication using the EpiShear Probe Sonicator (Active Motif). 3 μL β-mercaptoethanol was added and samples were heated to 95°C for 10 min before the same volume of each sample was loaded on NuPAGE Novex 4-12% Bis-Tris protein gels and run at 150 V ...
-
bioRxiv - Genetics 2023Quote: ... chromatin was sonicated for 30 cycles (30 s on, 30 s off, 25% amplitude) using an EpiShear probe sonicator (Active Motif) and DNA samples were purified using AMPure XP SPRI beads (Beckman Coulter ...
-
bioRxiv - Genetics 2023Quote: ... chromatin was sonicated for 8 minutes in Buffer 3 (20 s on, 30 s off, 25% amplitude) using an EpiShear probe sonicator (Active Motif).
-
bioRxiv - Cell Biology 2024Quote: ... The chromatin was subjected to 3 x 10 minute cycles of ultrasonic shearing using a PIXUL multi-sample sonicator (Matchstick Technologies Inc., Kirkland, WA, and Active Motif, Carlsbad, CA).(Bomsztyk et al. ...
-
bioRxiv - Developmental Biology 2022Quote: ... Lysates were sonicated and the DNA sheared to an average length of 300-500bp using the EpiShear™ Probe Sonicator (Active Motif, cat # 53051) with an EpiS-hear™ Cooled Sonication Platform (Active Motif ...