Labshake search
Citations for Pall :
1 - 31 of 31 citations for Streptavidin HRP Conjugate since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Microbiology 2019Quote: ... Streptavidin biosensors (Pall ForteBio) were hydrated at 26 °C using the Sidekick shaker accessory for 10 min at 1000 rpm ...
-
bioRxiv - Biochemistry 2022Quote: ... Streptavidin biosensor tips (Pall FortéBio) were pre-equilibrated in Octet buffer (1X DPBS [Gibco] with 0.1 % BSA and 0.05 % Tween-20 ...
-
bioRxiv - Biochemistry 2021Quote: ... Streptavidin (SA)-coated biosensors (Pall FortéBio) were hydrated in HKMTx for at least 30 min at 25 °C prior to use ...
-
bioRxiv - Biochemistry 2020Quote: ... Streptavidin (SA)-coated biosensors (Pall FortéBio) were hydrated in HKTTx solution for at least 10 min prior to use ...
-
bioRxiv - Biochemistry 2019Quote: ... Streptavidin (SA)-coated biosensors (Pall FortéBio) were hydrated in HKMTx for at least 30 min prior to use ...
-
bioRxiv - Biochemistry 2021Quote: ... using Streptavidin (SA)-coated biosensors (Pall FortéBio) in an assay buffer of 100 mM NaCl ...
-
bioRxiv - Synthetic Biology 2019Quote: Streptavidin sensors (Pall, Menlo Park, CA, USA) were pre-equilibrated in PBS buffer for 600s and loaded with biotinylated 209bp_CYC1pro or 209bp_benO_CYC1pro (100 nM ...
-
bioRxiv - Immunology 2021Quote: ... Super Streptavidin biosensors (fortéBio, Pall Life Science) were dipped in PBS prior to use and reacted with 5.8 μg/ml biotinylated peptide-loaded HLA molecule ...
-
bioRxiv - Biochemistry 2020Quote: ... using Streptavidin (SA)-coated biosensors (Pall FortéBio) in 20 mM HEPES pH 7.4 ...
-
bioRxiv - Microbiology 2021Quote: ... Super Streptavidin (SSA) biosensors (Pall ForteBio, CA, USA) were pre-equilibrated in buffer for 10 min at room temperature ...
-
bioRxiv - Immunology 2019Quote: ... Streptavidin-coated biosensor tips (Pall ForteBio, Menlo Park, CA) were used to capture biotinylated antigens ...
-
bioRxiv - Microbiology 2020Quote: ... Sialoglycopolyemers were bound onto streptavidin coated biosensors (Pall ForteBio) at ranges of concentrations from 0.01-0.55μg/ml in 10mM HEPES ...
-
bioRxiv - Microbiology 2023Quote: ... Sialylglycopolymers were immobilized on streptavidin-coated biosensors (Pall FortéBio) at concentrations ranging from 0.01 to 0.5 µg/ml in a solution containing 10 mM HEPES (pH 7.4) ...
-
bioRxiv - Immunology 2020Quote: ... was immobilized onto SAX biosensors (high precision streptavidin sensors: Pall fortebio ...
-
bioRxiv - Microbiology 2022Quote: ... equipped with High Precision Streptavidin (SAX) biosensors (PALL Life sciences, USA). Proteins were biotinylated using NHS-PEG4-Biotin (Thermo Scientific ...
-
bioRxiv - Immunology 2022Quote: Biotinylated peptides (100 nM) were loaded on streptavidin biosensors (Pall ForteBio) to a load threshold of 0.1 nm ...
-
bioRxiv - Immunology 2021Quote: ... (1) Biotinylated ACE2 (300 nM) was loaded on Streptavidin biosensors (Pall ForteBio) to a load threshold of 0.4-0.6 nm ...
-
bioRxiv - Microbiology 2020Quote: ... Biotinylated-rsCSP were loaded onto streptavidin biosensors (Pall ForteBio, cat No 18-5019) at 10 μg/mL in kinetics buffer (TBS + 0.002 % Tween20 and 0.01 % BSA) ...
-
bioRxiv - Microbiology 2022Quote: Biotinylated MPER peptide (30 nM) was loaded onto a streptavidin biosensor (Pall Fortebio) to a load threshold of 0.6 nm using an Octet RED96 system (Pall ForteBio) ...
-
bioRxiv - Biophysics 2023Quote: ... BLI sensors coated with streptavidin (SA sensors) were purchased from Forte Bio (PALL). Prior to use ...
-
bioRxiv - Biochemistry 2021Quote: ... For binding analysis biotinylated antigen (1 μg/mL) were immobilized on streptavidin (SA) biosensors (Pall) for 300 sec to ensure saturation ...
-
bioRxiv - Molecular Biology 2020Quote: ... biotinylated SARS-CoV-2 S trimer protein was loaded onto streptavidin (SA) biosensors (Pall FortéBio). S-trimer-bound biosensors were dipped into wells containing varying concentrations of ACE2 protein and the interactions were monitored over a 500-sec association period ...
-
bioRxiv - Microbiology 2023Quote: ... Biotinylated VHH16 (4 μg/mL) were loaded on streptavidin SA (18–0009) biosensors (Pall ForteBio) for 1 min ...
-
bioRxiv - Bioengineering 2020Quote: Biolayer inferometry was performed using the Octet Red96 with streptavidin (SA) biosensors (Pall ForteBio, Fremont, CA), which were hydrated for 15 min in kinetics buffer prior to each run ...
-
bioRxiv - Biophysics 2022Quote: ... Biotinylated PAR was captured on High precision Streptavidin (SAX) Dip and Read™ biosensors (Pall Fortebio) with a threshold of 0.4-0.5 nm ...
-
bioRxiv - Cell Biology 2024Quote: ... using ATF6⍺_LD variants as biotinylated ligands that were immobilised on streptavidin (SA)-coated biosensors (Pall FortéBio) and rat calreticulin (rCRT ...
-
bioRxiv - Biochemistry 2019Quote: ... 10 ng/mL of biotin-labeled target were loaded on Dip and Read™ Streptavidin (SA) Biosensors (Pall Fortebio) until the reading exceeded 1 nm ...
-
bioRxiv - Microbiology 2022Quote: ... Biotinylated SARS-CoV-2 RBD or S1 (4 µg/mL) were loaded on streptavidin SA (18-0009) biosensors (Pall ForteBio) for 1 min ...
-
bioRxiv - Cancer Biology 2020Quote: ... pH 7.4 and loaded onto Octet Streptavidin (SA) Biosensors (ForteBio) by following the manufacturer’s recommendations on an Octet RED384 machine (ForteBio, PALL Octet System). Biotin-249C immobilization was checked via Octet® Software prior to introduction of the entire V-ATpase complex and the individual H subunit protein diluted in blocking buffer (1X PBS + 0.05% Tween 20 + 0.2 % BSA + 10 μM Biotin ...
-
bioRxiv - Bioengineering 2020Quote: ... Affinity measurements were carried out at room temperature using an Octet RED96 system and streptavidin (SA)-coated biosensor tips (Pall ForteBio). Biotinylated ACE2 variants were diluted to 10 nM in PBS with 0.2% BSA and 0.05% Tween-20 (PBS-T) ...
-
bioRxiv - Microbiology 2024Quote: ... The glycans were preloaded onto streptavidin-coated biosensors at up to 0.3 µg/ml for 5 minutes in 1 × kinetic buffer (Pall FortéBio, Menlo Park, CA). Each test virus was diluted to a final concentration of 100 pM with 1 × kinetic buffer containing 10 µM oseltamivir carboxylate (American Radiolabeled Chemicals ...