Labshake search
Citations for New Objective :
1 - 37 of 37 citations for 7 Chloro 3 4 dihydro 1 2H isoquinolinone since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2022Quote: Peptides were resuspended in 4% formic acid and 3% acetonitrile and directly injected on a 75 μm ID column (New Objective) packed with 25 cm of Reprosil C18 1.9 μm ...
-
bioRxiv - Biochemistry 2020Quote: ... for 3 min and separated on a C18 analytical column (picofrit 75 μm ID x 150 mm, 3 μm, New Objective) using a linear gradient of 2 % to 45 % solvent B (80% acetonitrile ...
-
bioRxiv - Cancer Biology 2021Quote: ... 3 μm and a trap (IntegraFrit™ Capillary, 100 μm ID × 2 cm, New Objective) packed with Magic C18 AQ ...
-
bioRxiv - Biochemistry 2019Quote: ... The chromatographic separation was performed in a trap-and-elute manner using analytical PicoTip (30 cm, 75 μm I.D.) and trapping IntegraFrit (3 cm, 100 μm I.D.) columns (New Objective) packed in-house with polymer reverse-phase resin (Agilent ...
-
bioRxiv - Immunology 2022Quote: Peptides were resuspended in 0.1% formic acid and 3% directly injected on a 75 μm ID column (New Objective) packed with 25 cm of Reprosil C18 3 μm ...
-
bioRxiv - Cell Biology 2021Quote: ... the peptide mixtures were separated on 3 μm ReproSil-Pur C18AQ 15 cm × 75 μm ID emitter-column (New Objective) using Agilent 1200 series nano-LC ...
-
bioRxiv - Bioengineering 2020Quote: ... The cross-linked peptides were loaded onto a Picochip column (C18, 3 μm particle size, 300 Å pore size, 50 μm × 10.5 cm; New Objective) and eluted using a 60 min LC gradient ...
-
bioRxiv - Bioengineering 2020Quote: ... The cross-linked peptides were loaded onto a picochip column (C18, 3□μm particle size, 300□Å pore size, 50□μm□×□10.5□cm; New Objective) and eluted using a 60□min LC gradient ...
-
bioRxiv - Biochemistry 2020Quote: ... Dionex) and an in-house packed (3 μm C18 particles, Dr Maisch) analytical 50 cm × 75 μm emitter-column (New Objective). Peptides were eluted at 250 nL/min with an 8-40% (2 h ...
-
bioRxiv - Molecular Biology 2022Quote: ... and an in-house packed (3 µm C18 particles, Dr Maisch) analytical 50 cm x 75 µm ID emitter-column (New Objective). Peptides were eluted at 250 nl/min with a 5-35% B 120 min gradient (buffer B ...
-
bioRxiv - Molecular Biology 2022Quote: ... Dionex) and an in-house packed (3 µm C18 particles, Dr Maisch) analytical 50 cm × 75 µm emitter-column (New Objective). Peptides were eluted at 250 nL/min with an 5-40% (4 h ...
-
bioRxiv - Synthetic Biology 2023Quote: ... and an in-house packed (3 μm C18 particles, Dr Maisch) analytical 50 cm x 75 μm emitter-column (New Objective). Columns were operated at 45°C ...
-
bioRxiv - Biochemistry 2022Quote: ... The analytical column was a 75 μm x 10.5 cm PicoChip column packed with 3 μm ReproSil-Pur beads (New Objective, Inc. Woburn, MA) at 300 nL/min ...
-
bioRxiv - Microbiology 2022Quote: ... were injected via autosampler onto a 25 cm × 75 μM ID reversed phase column packed with 3 μM Reprosil (New Objective, Boston, MA). Peptides were separated and eluted with a gradient from 2 to 32% acetonitrile in 0.1% formic acid over 70 min at 300 nL/min into an LTQ Orbitrap XL hybrid mass spectrometer (Thermo Fisher Scientific ...
-
bioRxiv - Microbiology 2022Quote: ... Afterwards the peptides were eluted at 100 nL/min in a 90 minutes extended gradient from 10-40% acetic acid solvent (in 95% acetonitrile) to a 20-cm IntegraFrit column (50 μm inner diameter, Reprosil-Pur C18-AQ 3 μm, New Objective, Woburn, USA). The acquired spectra were analyzed using Thermo Proteome Discoverer in combination with Mascot (ThermoFisher Scientific ...
-
bioRxiv - Neuroscience 2022Quote: ... Trapping was done at 10uL/min for 4 min in loading solvent on a 25 mm C18 trapping column (New Objective). Peptides were then eluted using a nonlinear increase from 2 to 56% solvent B (0.1% Formic Acid in water/acetonitrile (2:8 ...
-
bioRxiv - Genetics 2019Quote: ... The analytical column was a 75 um × 10.5 cm PicoChip column packed with 3 um ReproSil-Pur® beads (New Objective, Inc. Woburn, MA). The flow rate was kept at 300nL/min ...
-
bioRxiv - Cell Biology 2022Quote: ... The analytical column was a 75 um x 10.5 cm PicoChip column packed with 3 um ReproSil-Pur® beads (New Objective, Inc. Woburn, MA). The flow rate was kept at 300nL/min ...
-
bioRxiv - Neuroscience 2023Quote: ... The analytical column was a 75 µm x 10.5 cm PicoChip column packed with 3 µm ReproSil-Pur® beads (New Objective, Inc. Woburn, MA). The flow rate was kept at 300 nL/min ...
-
bioRxiv - Neuroscience 2023Quote: ... The analytical column was a 75 µm x 10.5 cm PicoChip column packed with 3 µm ReproSil-Pur® beads (New Objective, Inc. Woburn, MA). The flow rate was kept at 300 nL/min ...
-
bioRxiv - Neuroscience 2020Quote: ... 1 μL of peptides was injected onto a C18 column (PicoChip™ 25 cm column packed with Reprosil C18 3 μm 120Å chromatography media with a 75 μm ID column and 15 μm tip; New Objective, Inc., Woburn, MA, USA) and then eluted off into the mass spectrometer with a 66 min linear gradient of 2-35% ACN/0.1% FA at a 300 nL/min ...
-
bioRxiv - Biochemistry 2021Quote: ... SEC or RP columns were interfaced to an LTQ Orbitrap XL/ETD with a custom ESI source and a 50 μm (± 3 μm) ESI tip (New Objective TT360-50-50-N-5). The mass spectrometer was tuned to the [M + 10H]10+ of ubiquitin by direct infusion ...
-
bioRxiv - Cancer Biology 2021Quote: ... 4 μg of each sample was separated using a self-packed analytical PicoFrit column (75 μm × 50 cm length) (New Objective, Woburn, MA, USA) packed with ReproSil- Saphir C18 1.5 μm (Dr ...
-
Domain-specific quantification of prion protein in cerebrospinal fluid by targeted mass spectrometrybioRxiv - Neuroscience 2019Quote: ... Samples were injected (1 to 2 µg) onto a 75 um ID PicoFrit column (New Objective) packed to 20 cm with Reprosil-Pur C18 AQ 1.9 um media (Dr ...
-
bioRxiv - Molecular Biology 2020Quote: ... Eluting peptides were sprayed into the mass spectrometer through 1 µm emitter tip (New Objective, Woburn, MA) at 2.4 kV ...
-
bioRxiv - Zoology 2022Quote: ... The eluted samples were sprayed through a charged emitter tip (PicoTip Emitter, New Objective, 10 ± 1 µm) into Orbitrap Fusion MS system (Thermo Fisher Scientific) ...
-
bioRxiv - Molecular Biology 2023Quote: ... Eluting peptides were sprayed into an Orbitrap-Lumos_ETD mass spectrometer through a 1 μm emitter tip (New Objective) at 2.4 kV ...
-
bioRxiv - Microbiology 2024Quote: ... Eluting peptides were sprayed into an Orbitrap-Lumos_ETD mass spectrometer through a 1-um emitter tip (New Objective) at 2.4 kV ...
-
bioRxiv - Cell Biology 2019Quote: ... Eluting peptides were sprayed into an LTQ Orbitrap Velos mass spectrometer through 1 μm emitter tip (New Objective, www.newobjective.com) at 2.4 kV ...
-
bioRxiv - Developmental Biology 2023Quote: ... peptides (1:10 dilution) were separated on 16 cm frit-less silica emitters (New Objective, 75 μm inner diameter), packed in-house with reversed-phase ReproSil-Pur C18 AQ 1.9 μm resin (Dr ...
-
bioRxiv - Neuroscience 2022Quote: ... Eluting peptides were electrosprayed at 2.4 kV into an Orbitrap-Lumos-Fusion mass spectrometer through a 1 μm emitter tip (New Objective). Survey scans (MS1 ...
-
bioRxiv - Biochemistry 2023Quote: ... 1 μg of peptide was loaded onto a 75 μm inner diameter x 360 μm outer diameter column (New Objective) packed in-house 1 to 30 cm with 1.7 micron BEH C18 particles (Waters Corp) ...
-
bioRxiv - Microbiology 2022Quote: ... and subsequently separated on an in-house packed PicoFrit column (75 µm x 200 mm, 15 µm, +/-1 µm tip, New Objective) with C18 phase (ReproSil-Pur C18-AQ ...
-
bioRxiv - Pharmacology and Toxicology 2021Quote: ... Desalting was performed with 8 μL of 0.1% formic acid plus 2% acetonitrile and the trap was subsequently brought online with a Self-Packed PicoFrit Column (New Objective part number PF360-75-10-N-5 ...
-
bioRxiv - Pharmacology and Toxicology 2020Quote: ... http://www.bischoff-chrom.com/hplc-prontosil-c18-h-c18-phasen.html Eluting peptides were sprayed into an QExactive HF mass spectrometer through an 1 µm emitter tip (New Objective, www.newobjective.com) at 2.0 kV ...
-
bioRxiv - Systems Biology 2020Quote: ... and buffer B (2% water and 0.1% formic acid in acetonitrile) through an analytical column (75 μm × 20 cm) and a fused silica PicoTip emitter (New Objective, Woburn, MA, USA) with 3-μm 200 Å Magic C18 AQ resin (Michrom BioResources ...
-
bioRxiv - Microbiology 2023Quote: For mass spectrometry analysis ∼0.1 µg protein was injected into an online nanoflow (200 nL min-1) 500 mm capillary column (Picofrit with 10 μm tip opening and 75 μm diameter; New Objective, PF360–75-10-N-5) packed in-house with 150 mm of C18 silica material (3 µm ...