Labshake search
Citations for Sartorius :
1 - 24 of 24 citations for CD209 Human HEK293 Fc since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Immunology 2022Quote: KD measurements of Fc-tagged Human FcμR (Cat: 13556-H02H, SinoBiological) immobilised on Anti-Human IgG Fc (AHC) (Cat: 18-5060, Sartorius) biosensors were performed on the Octet Red96® system with the loading threshold set at 1.0 nm and utilizing the recombinant Pertuzumab and Trastuzumab IgM VH whole antibodies variants in five serial diluted concentrations (12.5 to 200nM ...
-
bioRxiv - Immunology 2022Quote: ... Anti-Human Fc sensor tips (ForteBio, now Sartorius) were loaded with 200 nM mAb at a threshold of 0.8nm and then submerged into wells containing 100 nM (protomer/monomer concentration ...
-
bioRxiv - Biochemistry 2023Quote: ... Anti-Human Fc sensor tips (ForteBio, now Sartorius) were loaded with 200 nM mAb or FcACE2 to a threshold of 0.8 nm and then submerged into wells containing 100 nM (protomer/monomer concentration ...
-
bioRxiv - Molecular Biology 2024Quote: ... Anti-human IgG Fc capture (AHC) biosensor tips (Sartorius) were equilibrated for ten minutes in a 1:4 mixture of conditioned Freestyle 293 medium and 1X HBS EP+ to match the diluted media ...
-
bioRxiv - Immunology 2023Quote: ... Antibodies were captured on anti-human Fc AHC2 tips (Sartorius). Data capture was performed using Octet Data Acquisition software version 9.0 (ForteBio) ...
-
bioRxiv - Evolutionary Biology 2022Quote: ... IgG was loaded onto Anti-Human Fc Capture (AHC) biosensors (Sartorius, #18-5060). To reduce the avidity effect ...
-
bioRxiv - Immunology 2023Quote: ... BLI binding experiments were performed with Anti Human IgG Fc (AHC) biosensors (Sartorius 18-5060). Using Octet buffer (PBS with 0.1% Tween20) ...
-
bioRxiv - Immunology 2024Quote: ... Monoclonal Moo1 and Moo2 antibodies were immobilized on anti-human IgG Fc Capture (AHC) biosensors (Sartorius) to capture monoclonal antibodies at a concentration of 50 µg/mL for 5 min and washed with octet buffer ...
-
bioRxiv - Bioengineering 2023Quote: ... Antibody CSL362 hIgG1 (captured ligand) was captured by Anti-Human Fc capture biosensor (AHC) (Sartorius, PN: 18-5060) for 300s at 0.5µg/mL ...
-
bioRxiv - Immunology 2023Quote: ... Human antibodies (5 μg/mL or 7.5 µg/mL) were captured on pre-conditioned anti-human IgG Fc-capture biosensors (AHC, Sartorius) for 600 s ...
-
bioRxiv - Microbiology 2022Quote: ... and 0.5% nonfat dry milk) to 100 nM and immobilized for 60 s to anti-human IgG Fc capture biosensors (Sartorius). Sensors were transferred to assay buffer for 30 s to set the baseline ...
-
bioRxiv - Immunology 2022Quote: ... Anti-hIgG Fc capture (AHC) or anti-mIgG Fc capture sensors (Sartorius) were functionalized with monoclonal antibodies ...
-
bioRxiv - Immunology 2023Quote: All BLI for data shown in Figure 1 and Figure S1 was carried out on an OctetRED384 (ForteBio) using anti-human Fc-capture sensors (Sartorius, 18-5060) to immobilize anti-PfRH5 mAbs ...
-
bioRxiv - Bioengineering 2023Quote: ... Mouse Fc-capture biosensor tips were purchased from Sartorius. Chicken plasma (cat # ...
-
bioRxiv - Immunology 2021Quote: ... IgGs were immobilized on Anti-hIgG Fc Capture (AHC) biosensors (Sartorius Corporation) and a concentration series of 200 ...
-
bioRxiv - Synthetic Biology 2023Quote: ... and captured on Anti-hIgG Fc Capture (AHC) Biosensors (Sartorius 18-5060). Capture was recorded for 40 seconds ...
-
bioRxiv - Immunology 2023Quote: ... Mouse antibodies (7.5 μg/mL anti-OVA and 5 μg/mL anti-RBD) were captured on pre-conditioned anti-mouse IgG Fc-capture biosensors (AMC, Sartorius) for 600 s ...
-
bioRxiv - Molecular Biology 2023Quote: Human NIL iPSCs were cultured in Nutristem (Sartorius, #05-100-1A) supplemented with Pen/Strep 0.1% on geltrex-coated plates (Thermo Fisher Scientific ...
-
bioRxiv - Biochemistry 2022Quote: ... In our BLI experiments, ACE2 Fc-fusions are tethered to either Streptavidin biosensors (WT-ACE2, CVD293) (Sartorius®, Item no.: 18-5019) or ProtA biosensors (Sartorius® ...
-
bioRxiv - Biochemistry 2024Quote: Binding kinetics of ZHER2-CK2α were measured by biolayer interferometry (BLI) on an OctetRed384 using in-house made HER2-Fc-AviTag immobilized on streptavidin biosensors (Sartorius, 18-5021). Kinetic measurements were performed in PBS with 0.1% bovine serum albumin and 0.05% Tween 20.
-
bioRxiv - Cancer Biology 2021Quote: ... Beads detecting cytokines from human were analyzed on an IQue Screener Plus (Sartorius). All assays were analyzed using quintuplicate determinations.
-
bioRxiv - Molecular Biology 2022Quote: Human primary keratinocytes were plated in Essen ImageLock 96-well plates (Sartorius, Göttingen, Germany) at 15,000 cells per well for migration assay and in 12-well plates at 20,000 cells per well for cell growth assay ...
-
bioRxiv - Cancer Biology 2023Quote: The human plasma samples were filtered (Minisart NML syringe filters, pore size: 0.8 µm; Sartorius) and diluted with 1x Phosphate-Buffered Saline without calcium and magnesium buffer (Gibco ...
-
bioRxiv - Microbiology 2023Quote: We performed human plasma and avidity variant Abs’ binding using an Octet Red384 biolayer interferometer (Sartorius). We completed all the steps in 0.05% BSA and 0.002% Tween20 ...